Page 1: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

Goodman and AmanaFurnace Orientation

Page 2: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

Complete Line of Furnaces

92 - 95% AFUE

80% AFUE

Page 3: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

Nomenclature / Summary

G M S 8045

3 A N A

1st 2nd 3rd 4th 5th 6th 7th 8th 9th GKS9GMS/GDS8

GMH8/95GDH8/GCH9

GME8 GMV95GCV9

AMH8/95AMV8ADV8/ACV9

Page 4: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

Goodman Single Stage (S)

• Patented Aluminized Tubular Heat Exchanger

• Stainless Steel Secondary Heat Exchanger – 92% Models

• Norton Mini-Igniter• Self Diagnostics LED• Four Speed PSC Motor• Upflow / Horizontal• Downflow – 80% only

Page 5: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

Goodman Two Stage (H)

• Aluminized Heat Exchanger

• Stainless Steel Secondary HE – 93% to 95% Models

• Single or Two Pipe Flue – 90%

• Silicon Nitride Igniter• Stored Self Diagnostics• Two Stage Gas Valve• Upflow / Horizontal /

Downflow

Page 6: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

Don’t Take Our Word For It

Page 7: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

Goodman Two Stage (V)

• Aluminized Heat Exchanger

• 90% Models Only• Variable Speed Motor –

ECM• Premium SEER Model• Color Coded Connections• Silicon Nitride Igniter• Self Diagnostics LED• Upflow, Downflow &

Horizontal Models Available

Page 8: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

• Low Power Consumption• Virtually Unlimited

Speed Options• Dip Switch Speed

Orientation Set-Up• Designed To Overcome

System Static• Future Models Allow

Communication Features

ECM Motor (V Models)

Page 9: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

ECM vs. PSC

Page 10: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

Coming Attractions – 80%

39” 33-1/3”

• Impacts The Entire 80% Line

• Same Features, Just Shorter

• 1st & 2nd Quarters - 2009

Page 11: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

Amana Two Stage (H)

• Stainless Steel Tubular Primary Heat Exchanger

• SS Secondary HE – 90%• Single or Two Pipe Flue• Silicon Nitride Igniter• Stored Self Diagnostics• Two Stage Gas Valve• Upflow / Horizontal

Page 12: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

Amana Two Stage (V)

• Stainless Steel Tubular Primary Heat Exchanger

• 80% & 90% Models• Variable Speed Motor –

ECM• Color Coded Connections• Silicon Nitride Igniter• Self Diagnostics LED• Upflow, Downflow &

Horizontal Models Available

Page 13: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

Unit Replacement Warranties

Page 14: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

The Competition

Page 15: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

Wrinkle-Bend Technology

• Manufacturing Stress Including Wall-thinning Is Minimized

• Wrinkles Promote Turbulence To Aid Heat Transfer Efficiency

Page 16: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

Dual-Diameter Muffler-Joint

• The Large Tube Fits Inside The Small Tube

• Tubes Are Solidly Joined With A Crimping Process

• Thermal Growth Ensures A Tight Seal

• Combustion Air Velocity Is Optimized

• Efficiency Is Maximized

Page 17: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

Clamshell Design

• Some Competitors Still Use Clamshell• But Why?

Trane ClamshellLennox ClamshellCarrier Clamshell

Page 18: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

ANSI.Z21.47 Test Began in 1995

Repeated Thermal Cycles From 200F To 1,100F

As of August 2008 the Million-Air Heat Exchanger Achieved 1,929,000 Cycles

That’s More Than 38 Times Better Than Trane

And It’s Still Going!

The Best Heat Exchanger

Guess when the Amana heat exchanger hits 2

million cycles for a chance to win big prizes at

www.amana-hac.com!!!

Goodman HE – 25,510

Page 19: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

120-Volt SiNi Ignition System

• All Models Except Value Models (GMS And GKS)

• Most Durable And Reliable Igniter In The Industry

• Seven Times Stronger Than Silicon Carbide

• More Reliable Than 90-volt Sini

• Less Sensitive To Grounding

Page 20: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

Selectable Single or Two-Stage

Furnace Ships as a Single-Stage Unit

Flip This Switch To Activate 2-Stage

Operation

This Switch Adjusts Low-Stage Timing Between 5 Minutes

Fixed or Self-Adjusting Mode

Page 21: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

Self-Adjusting Low-Stage

Call For Heat Call Satisfied

High

Low 5 min

Off

Call For Heat Call Satisfied

High

Low 1 to 12 min

Off

Fixed 5 min Low-Stage

Self-Adjusting Low-Stage

This Switch Adjusts Low-Stage Timing 5 Minutes Fixed

Or Self-Adjusting

Cold = 1 minMild = 12 min

Page 22: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

Push and Hold Button For 2

Seconds

Stored Diagnostics (Last Five Faults)

LED Flashes Out Last 5 Diagnostic Codes

Most Recent Fault is Displayed First and

Least Recent Fault is Displayed Last

Page 23: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

• All AMH & GMH Furnaces Have Three Operational Speeds:– Cooling – High Stage

Cool– High Heat – High Stage

Heating– Low Heat - Comes On

When The Furnace Operates On Low-Stage Or Constant Fan Speeds

Low Constant Fan Mode

Low Heat

Cooling

High Heat

Page 24: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

• Featured On All Goodman and Amana Models Except Value Models (GMS8-B & GKS9)

• Reduces The Chances of Wiring Error

Color-Coded, Low-Voltage Label

Page 25: Goodman and Amana Furnace Orientation. Complete Line of Furnaces 92 - 95% AFUE 80% AFUE

Goodman Quality

Compare Us To The Competition And You’ll Be Convinced…

Why Pay More For Less?