gsav.com.my - altra air fans with whalepower technology
DESCRIPTION
Altra-Air FansWith WhalePower Technology. Get to know more about our altra air fansTRANSCRIPT
Overview• HVLS Fans?• Applications• Benefits• Energy Savings Heating & Cooling• New Build Savings• Specifications• Operation• Question
Altra-Air FansIntroduction
HVLS FansWhat does HVLS represent? HVLS=High Volume,Low Speed A lot of air movement at slow rpm Nearly 400,000 CFM at 57 RPM and only 1,5kw motor.
How is it different from other fans? Size (range from 2.4-7.3m in diameter) 0.75-1,5kw motors Unique Design & Engineering (air foil blades) Quiet (64dBa maximum) Controlled by a Vaiable Frequency Drive
Air Foil DesignWhalePower’s Tubercle™ Technology Derived from the Humpback whale Tubercles (or bumps) on the leading edge More efficient air handling
How does it work? Channels air between Tubercles This creates less drag Less drag=increased pitch Increased pitch=more air
Altra-Air FansApplications
ApplicationsLarge Open SpacesMore than 4m HeightLimited Wind InfluenceSolid StructureElectricity Available
ApplicationsWarehouseDistribution CentresGymnasiumAuditoriumsWorkshopsContinued…
ApplicationsBig Box StoresIndoor PoolsHangarsFactoriesDairiesMore…
Altra-Air FansHVLS Benefits
BenefitsReduced Energy ConsumptionImproved Air QualityDecreased Humidity LevelsEvenly Mixed Air EnvelopeIncreased Occupant Comfort & ProductivityMinimal Maintenance & Inexpensive
Operation
Altra-Air FansEnergy Savings
Cooling• Two types of Energy Savings1.Thermostat Change Basic Effective Temperature
2.Supplemental Cooling Free Cooling
Cooling• Basic Effective Temperature (BET)1.Thermostat ChangeIncreased temperature set pointDue to “wind-chill effect” from fansReduced structual heat gainReduced enthalpy drop of cooled air
Energy SavingsFree Cooling2. Supplemental CoolingCooling period before Air ConditioningA/C Units run less frequently
Reducing DuctworkHybrid HVLS/ Ductwork Specification
Reducing TonnageHVLS Fans Provide…Ventilation EffectivenessEvaporative CoolingCompresosor OptimizationLeading to… Reduced Capital Investment
Ventilation EffectivenessConsider Thermal Mass…Ground temperature naturally cools concreteAirflow across concrete increases
transmissionNatural cooling to the inside space now
occursThis leads to better ventilation effectiveness
Evaporative CoolingHVLS fans with AC Systems…Increase airflow on occupants of the
structureLeads to an increase in temperature set pointDecreasing energy requirementsCreating continual savings
Compressor OptimizationWith constant speed compressors…If a building has four AC units running at 50%Compressor efficiency is lowIf the same building utilizes HVLS FansOnly 2 units are required running at 100%Compressor efficiency is now maximized
Reduced Capital InvestmentsWe now require…Less AC unitsLess Duct WorkWhich…Offsets HVLS CostImproves efficiency
Altra-Air FansTotal Savings
Total Project SavingsInitial Savings Less Ductwork and AC Units Required More than Pays for Cost of HVLS FansContinued Savings Less Tonnage Required Decreased Usage Hours
Altra-Air FansSpecifications
SpecificationFan Size(m)
Power(w)
Speed(RPM)
Air Flow(CFM)
Coverage(m-diameter)
Sound(dBa)
7.3 1403 57 397,701 70.1 64
6.1 1403 63 330,050 61.0 63
4.9 805 73 182,173 42.7 62
3.7 644 123 134,152 24.3 62
2.4 644 154 42,136 10.7 60
Thank YouAny QuestionsWarehouse: Keruilai Far East (M) Sdn Bhd No.1,Persiaran Industri Lahat 6,Kawasan perindustrian Rima Lahat,1500 Lahat, Perak, MalaysiaTel: 605-321 8803 Fax: 605-322 0803
KL Office: Guan Seng Air Ventilation (M) Sdn Bhd (1053845-X)No.14, Jalan 6/37B, Taman Bukit Maluri,52100, Kepong, Kuala LumpurTel: 6012-921 8538
For More Information:www.gsav.com.myE-mail: [email protected]