guided wave testing on insulated overhead pipeline for cui

16
Guided Wave Testing on Insulated Overhead Pipeline Corrosion Lee Ping Hung Taiwan Metal Quality Control Co. Ltd Tel. 07-8019312, 8019340 Fax. 07-8063017 WEB: www.tmqc.com.tw 1 2016/10 TMQC in CNDT2016

Upload: ping-hung-lee

Post on 11-Apr-2017

64 views

Category:

Engineering


2 download

TRANSCRIPT

Page 1: Guided wave testing on insulated overhead pipeline for CUI

Guided Wave Testing on Insulated Overhead Pipeline Corrosion

Lee Ping Hung

Taiwan Metal Quality Control Co. LtdTel. 07-8019312, 8019340 Fax. 07-8063017

WEB: www.tmqc.com.tw

1 2016/10TMQC in CNDT2016

Page 2: Guided wave testing on insulated overhead pipeline for CUI

Guided Wave Testing, GWT

GWT Ring

Pipe corrosion

Guided wave

2016/10TMQC in CNDT20162

Local Corrosion

General Corrosion

Page 3: Guided wave testing on insulated overhead pipeline for CUI

Guided Wave Propagation Beyond Elbow

2016/10TMQC in CNDT20163

T(0,1)Incident

T(0,1)Focusing

T(0,1)Reflection

T(0,1)Transmission

T(0,1)Reflection

T(0,1)Mode Conversion

Page 4: Guided wave testing on insulated overhead pipeline for CUI

Guided Wave Testing on Insulated Overhead Pipeline Corrosion

2016/10TMQC in CNDT20164

Testing on both vertical section

Testing on Horizontal section

Page 5: Guided wave testing on insulated overhead pipeline for CUI

GWT signals of pipe support beyond the elbow on overhead pipeline

2016/10TMQC in CNDT20165

Page 6: Guided wave testing on insulated overhead pipeline for CUI

Wave Propagation at Pipe Support and Elbow

2016/10TMQC in CNDT20166

Reflection

Transmission

Wave Leakage

Pipe Support Pipe Elbow

Wave Natural Focusing

Page 7: Guided wave testing on insulated overhead pipeline for CUI

Research in 2012 CNDT conference

2016/10TMQC in CNDT20167

Frequency: 20~30kHz-Guided Wave Focusing-Sensitivity higher than 2~3 times

Easy to misscorrosion detection Natural focusing is depended on

the wave mode, frequency and location

According to the difference of the sensitivity, it needs modify the severity of the GWT signal.

Next Step: How to get a reliable analysis beyond elbow

Page 8: Guided wave testing on insulated overhead pipeline for CUI

2014Guided wave natural focus map at elbow

2016/10TMQC in CNDT20168

Intrado

Extrado

Page 9: Guided wave testing on insulated overhead pipeline for CUI

2014Guided wave natural focus map beyond elbow

2016/10TMQC in CNDT20169

Extrado

Intrado3 o’clock

9 o’clock

Page 10: Guided wave testing on insulated overhead pipeline for CUI

2014Guided wave natural focus map beyond elbow

2016/10TMQC in CNDT201610

3 o’clock

9 o’clock

Page 11: Guided wave testing on insulated overhead pipeline for CUI

GWT signal of Overhead Pipeline without Corrosion

2016/10TMQC in CNDT201611

-25.0 -20.0 -15.0 -10.0 -5.0 0.00.0

0.5

1.0

1.5

2.0

2.5

G3-1

12#5

974

(Lin

ear)

-25.0 -20.0 -15.0 -10.0 -5.0 0.00.0

0.5

1.0

1.5

2.0

2.5

Distance (m)

G3-1

12#5

981

(Lin

ear)

B3W2S1W1B2B1

B4B3W2S1W1B2

Page 12: Guided wave testing on insulated overhead pipeline for CUI

GWT signal of Overhead Pipeline with Corrosion

2016/10TMQC in CNDT201612

-20.0 -15.0 -10.0 -5.0 0.00.0

1.0

2.0

3.0

G3-1

12#6

209

(Lin

ear)

-20.0 -15.0 -10.0 -5.0 0.00.0

1.0

2.0

3.0

Distance (m)

G3-1

12#5

990

(Lin

ear)

-F1B5 B6X1 W3

B8-F1B7X2X3W3B6

Page 13: Guided wave testing on insulated overhead pipeline for CUI

Multi-frequency Analysis: GWT signal of Overhead Pipeline with Severe Corrosion

2016/10TMQC in CNDT201613

-12d

B

-14.0 -12.0 -10.0 -8.012

9

6

3

12

Cloc

k

-14.0 -12.0 -10.0 -8.00.0

0.2

0.4

0.6

0.8

1.0

1.2

Distance (m)

Amp (L

inea

r)

B6 X1 W3

-12d

B

-14.0 -12.0 -10.0 -8.012

9

6

3

12

Cloc

k

-14.0 -12.0 -10.0 -8.00.0

1.0

2.0

3.0

Distance (m)

Amp (L

inea

r)

B6 X1 W3

45kHz 30kHz

Page 14: Guided wave testing on insulated overhead pipeline for CUI

GWT signal collected from the ring location on horizontal section

2016/10TMQC in CNDT201614

-18d

B

-4.0 -2.0 0.0 2.0 4.0 6.012

9

6

3

12

Cloc

k

-4.0 -2.0 0.0 2.0 4.0 6.00.0

2.0

4.0

6.0

8.0

10.0

12.0

Distance (m)

Amp

(Lin

ear)

B7X2X3W3X1B6

Bottom Corrosion

Page 15: Guided wave testing on insulated overhead pipeline for CUI

Corrosion X1,X2 surface VT after polishing

2016/10TMQC in CNDT201615

X1Multiple holes

X2Multiple severe corrosion

Page 16: Guided wave testing on insulated overhead pipeline for CUI

Conclusion

Pipeline Type

Simple support √ x

Welded support √ √

Clamp support √ √

Simple support √ x

Welded support √ √

Clamp support √ ∆

2016/10TMQC in CNDT201616

√: Need GWT, x: No need GWT,∆ : Depend on contact conditionPS. If testing results on vertical section show obvious corrosion signal, another testing location should be done in the overhead pipeline inspection results

Bare OverheadPipeline

Insulated OverheadPipeline

Pipe Support Type Testing on both vertical section

Testing on Horizontal section