TESTING AND SUBSEA e Halliburton Testing and Subsea Choke Manifold enables an operator to manually control the well stream at the surface by means of an adjustable or fixed choke. e choke provides the operator with either progressive manual, powered, or fixed control of the well by opening or closing the choke orifice. Design of the choke manifold allows operators to limit erosion that occurs from the very high velocities at and immediately downstream of the orifice - to the replaceable parts within the choke. e Halliburton Choke Manifold is available with 10,000 psi (68.9 MPa) or 15,000 psi (103.4 MPa) working pressures and 5-gate valve or 8-valve “block and bleed” versions. On one side, an adjustable choke allows more flexible control for wellbore cleanup rates. On the other side is a positive choke to give more accurate flow control for predetermined fluids for various test procedures. By using the valves and adjustable choke, the operator can change the positive choke without stopping operations or affecting test objectives. Features Adjustable and positive chokes to help maintain a constant flow rate, which improves test data quality. Designed for easy maintenance during operations and lower overall redress cost due to its component design. 8-valve choke manifold, utilized as part of solids management packages, allows safer control through the use of “double block and bleed” valves. Meets applicable industry standards (API 6A) and can be certified through third parties, as required. Choke Manifold Benefits 5-valve versions of the 10,000 psi (68.9 MPa) and 15,000 psi (103.4 MPa) choke manifolds are equipped with a center bypass valve, allowing more options during cleanup operations. 8-valve versions of the 10,000 psi (68.9 MPa) and 15,000 psi (103.4 MPa) choke manifolds are equipped with two hydraulic- actuated primary valves on the upstream side of the manifold. Data headers can be integrated into the choke manifold design and skid. Blanking caps on all versions are drilled and tapped to 9/16-in. autoclave. HAL36575

Upload: monokoe

Post on 03-Jan-2016

47 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: h 07121 Choke Manifold

TESTING AND SUBSEA

The Halliburton Testing and Subsea Choke Manifold enables anoperator to manually control the well stream at the surface bymeans of an adjustable or fixed choke. The choke provides theoperator with either progressive manual, powered, or fixed controlof the well by opening or closing the choke orifice. Design of thechoke manifold allows operators to limit erosion that occurs fromthe very high velocities at and immediately downstream of theorifice - to the replaceable parts within the choke.

The Halliburton Choke Manifold is available with 10,000 psi (68.9 MPa) or 15,000 psi (103.4 MPa) working pressures and 5-gate valve or 8-valve “block and bleed” versions. On one side, an adjustable choke allows more flexible control for wellbore cleanuprates. On the other side is a positive choke to give more accurate flowcontrol for predetermined fluids for various test procedures. By usingthe valves and adjustable choke, the operator can change the positivechoke without stopping operations or affecting test objectives.

Features • Adjustable and positive chokes to help maintain a constant

flow rate, which improves test data quality.

• Designed for easy maintenance during operations and loweroverall redress cost due to its component design.

• 8-valve choke manifold, utilized as part of solids managementpackages, allows safer control through the use of “double blockand bleed” valves.

• Meets applicable industry standards (API 6A) and can becertified through third parties, as required.

Choke Manifold

Benefits• 5-valve versions of the 10,000 psi (68.9 MPa) and 15,000 psi

(103.4 MPa) choke manifolds are equipped with a centerbypass valve, allowing more options during cleanup operations.

• 8-valve versions of the 10,000 psi (68.9 MPa) and 15,000 psi(103.4 MPa) choke manifolds are equipped with two hydraulic-actuated primary valves on the upstream side of the manifold.

• Data headers can be integrated into the choke manifold designand skid.

• Blanking caps on all versions are drilled and tapped to 9/16-in. autoclave.

HA

L365

75

Page 2: h 07121 Choke Manifold

TESTING AND SUBSEA

www.halliburton.com

© 2011 Halliburton. All rights reserved. Sales of Halliburton products and services will be in accord solely with the terms and conditions contained in thecontract between Halliburton and the customer that is applicable to the sale. H07121 12/11

Technical Specifications

Part NumberDescription

Working Pressure psi (MPa)Working Temperature˚F (˚C)ServiceStandardCodeFlangesValve Type

Valve Configuration

Adjustable Type

Inlet

Outlet

Dimensions in. (mm) (LxWxH)

101786220

3 1/16-in. 8-valve choke manifold

10,000 (68,9)

-20 to 350 (-29 to 177)

H2S

NACE MR-01-75

API 6A PSL-3

3-1/16 in. BX-154

WOM Magnum Model 200 (M) gate valve

6 manifold valves and 2 hydraulic-actuated primary upstream valves

3-1/16 in. 10K F.E. 2-in. maximum orifice

3-in. fig. 1502 Female hammer union

3-in. fig. 1502 Male hammer union

100 × 151 × 53(254 × 384 × 135)

101767056

3 1/16-in. 5-valve choke manifold

15,000 (103.4)

-20 to 350 (-29 to 177)

H2S

NACE MR-01-75

API 6A PSL-3

3-1/16 in. BX-154

WOM Magnum Model 200 (M) gate valve

4 manifold valves and 1 by-pass valve

3-1/16 in. 10K F.E. 2-in.maximum orifice

3-1/16 in. BX-154 flange

3-1/16 in. BX-154 flange

103 × 97 × 44(262 × 246 × 112)

101767055

3 1/16-in. 5-valve choke manifold

10,000 (68.9)

-20 to 350 (-29 to 177)

H2S

NACE MR-01-75

API 6A PSL-3

3-1/16 in. BX-154

WOM Magnum Model 200 (M) gate valve

4 manifold valves and 1 by-pass valve

3-1/16 in. 10K F.E. 2-in.maximum orifice

3-in. fig. 1502 Femalehammer union

3-in. fig. 1502 Malehammer union

100 × 96 × 39.5(254 × 244 × 100)

101788329

3 1/16-in. 8-valve choke manifold

15,000 (103.4)

-20 to 350 (-29 to 177)

H2S

NACE MR-01-75

API 6A PSL-3

3-1/16 in. BX-154

WOM Magnum Model 200 (M) gate valve

6 manifold valves and 2 hydraulic-actuated primary upstream valves

3-1/16 in. 10K F.E. 2-in.maximum orifice

3-1/16 in. BX-154 flange

3-1/16 in. BX-154 flange

103 × 151 × 53(262 × 384 × 135)