LINT INTERCEPTOR

Insert 2x4's Inside Unit For Structural Bracing. Secure Lids On Unit Prior To Concrete PourRemove 2x4's Once The Concrete Has Cured

Lid(s) Must Be Screwed To The Unit At All Times Except When Cleaning The Filter

Rebar is Necessary To Prevent The Unit From Floating Out Of The Ground

Plan View

Sectional Front View

2x4's

Rebar

Ground Level

Holes For Rebar

EarthConcrete

Pea Gravel Or EquivalentLevel Surface

Use Hole Saw To Cut Hole For Fitting Kits ProvidedPlace Gasket On Inside And Outside Of UnitScrew Fitting Kit Together Compressing Gaskets To The Unit. No Adhesive RequiredGlue PVC Pipes Into Fitting Kits

In Ground InstallationSince 1957

H-M Company Installation/Operation InstructionsTelephone: (800) 365-1900

2305 Gilbert AvenueCincinnati, Ohio 45206Telephone: (513) 281-3832

Fax: (513) 281-0572www.draintroughs.com

Lint Filter Must Be Cleaned On A Weekly Basis

Sectional Side View

Inlet

Outlet

Filter(Typical)

(Typical)

Rebar is Required for units that are larger than 2'l x 2'w x 2'h.

Screw Fitting Kit Together Compressing Gaskets To The Unit. No Adhesive Required

H-M CompanyLINT INTERCEPTOR

Glue PVC Pipes Into Fitting Kits

Place Gasket On Inside And Outside Of UnitUse Hole Saw To Cut Hole For Fitting Kits Provided

Outlet Location Must Be Located Within 6" Of The Bottom Of The Unit. (See Drawing Above)

Lid(s) Must Be Screwed To The Unit At All Times Except When Cleaning The Filter

Supported On all Four Sides And In The Middle. Base Construction (If Required), And It'sIf Unit Is Installed On A Base The Top Of The Base Must Be A Solid Level Surface That Is

Since 1957 On Or Above Ground Installation

Installation/Operation InstructionsTelephone: (800) 365-1900

2305 Gilbert AvenueCincinnati, Ohio 45206Telephone: (513) 281-3832

Fax: (513) 281-0572www.draintroughs.com

Side View

Inlet Location

Outlet Location

(Typical)

(Typical)

Outlet LocationIncorrect

(See Notes)

Structural Integrity Is The Responsibility Of Others.

Lint Filter Must Be Cleaned On A Weekly Basis

Lint Filter

Drain To Sewer

IncorrectDrain To Sewer