hawk diaphragm seals

5
Double Flange Diaphragm HAWK Diaphragm Seals P-9A Temperature limit -90 to 450° depending on various sealing sealing liquid. standard-Silicon...-50 to 300°C Upper Housing and Cooling Suitable Pressure Range Max 1500 PSI The size of the diaphragm will effect the auucuary and temperature drift, please contact with the factory for detailed information in order to satisfy your request accuracy and temperature effect. Specications Diaphragm seals are used to isolate pressure measuring element of pressure gauges, pressure switches, pressure transmitters, and other pressure instruments from pressure media which may be corrosive, viscous, hot or sedimentary. The ange connection is directly attached to the process by means of a ANSI, DIN, or JIS ange. The metal diaphragm is welded to the front of ange. This front diaphragm design improve the insufciency which the standard ange diaphragm seal may be insensitive due to the media clogging within Typical Application Freezing or soildifying uids Corrosive media Suspended solids Viscous uides High temperature environment Chemical and petrochemical industries Water treatment Filtration systems Incinerators 1 Metal Diaphragm Welded to Flange Non-Metal Diaphragm Clamped or ANSI, DIN, JIS Flange Process Connection Flushing Plug Available Cleaned by Removing Seal DS 504 Series an internal cavity. They are particularly suitable for corrosive, heavily loaded or viscous media which may damage or clog the process connection of the measuring instrument. In order to reduce the temperature effect for the instrument, the cooling tower is recommended for the directly mounted instrument when temperature of the media > -120°C and capillary remote mounted instrument when temperature of the Media > 180°C Tower Material 316L Stainless Steel, 304SAS, Monel, Hastelloy B, Hastelloy C, Inconel, Nickel, 316SS, Titanium, Tantalum, Platinum, Zirconium Diaphragm Material 316L Stainless Steel, 304SAS, Monel, Hastelloy B, Hastelloy C, Inconel, Nickel, 316SS, Titanium, Tantalum, Platinum, Zirconium Mounting Directly or Remote capillary mounting Lower Housing and Flange 316L Stainless Steel, 304SAS, Monel, Hastelloy B, Hastelloy C, Inconel, Nickel, 316SS, Titanium, Tantalum, Platinum, Zirconium Material Process Connection ANSI Flange ½”................5” JIS Flange 15A..............200A DIN Flange DN15........DN200 Rating ANSI Flange 150LB...2500LB JIS 10K................63K DIN PN2.5..........PN400Bar Filling Liquid Silicon oil, Silicon oil high temp, Glycerin, Mineral oil, Vegetable Oil, FDA approved White oil, Halocarbon, Glycerin/Water, Fluorinated oil, Neobee 20, Synthetic Oil Kn77 FDA Bonded to Housing Pressure Temperature Level Flow www.hawkgauge.com.tw

Upload: others

Post on 31-Jan-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HAWK Diaphragm Seals

Double Flange DiaphragmHAWK Diaphragm Seals

P-9A

Temperature limit

-90 to 450° depending on various sealing sealing liquid. standard-Silicon...-50 to 300°C

Upper Housing and Cooling

Suitable Pressure Range

Max 1500 PSI

The size of the diaphragm will effect the

auucuary and temperature drift, please

contact with the factory for detailed information in order to satisfy your request accuracy and temperature effect.

Specications

Diaphragm seals are used to isolate pressure measuring element of pressure gauges, pressure switches, pressure transmitters, andother pressure instruments from pressure media which may be corrosive, viscous, hot orsedimentary. The ange connection is directlyattached to the process by means of a ANSI, DIN, or JIS ange. The metal diaphragm is welded to the front of ange. This frontdiaphragm design improve the insufciency which the standard ange diaphragm seal maybe insensitive due to the media clogging within

Typical Application

▉ Freezing or soildifying uids

▉ Corrosive media

▉ Suspended solids

▉ Viscous uides

▉ High temperature environment

▉ Chemical and petrochemical industries

▉ Water treatment

▉ Filtration systems

▉ Incinerators

1

▉ Metal Diaphragm Welded to Flange

▉ Non-Metal Diaphragm Clamped or

▉ ANSI, DIN, JIS Flange Process

Connection

▉ Flushing Plug Available

▉ Cleaned by Removing Seal

DS 504Series

an internal cavity. They are particularly suitablefor corrosive, heavily loaded or viscous mediawhich may damage or clog the process connection of the measuring instrument.

In order to reduce the temperature effect for the instrument, the cooling tower is recommended for the directly mounted instrument when temperature of the media > -120°C and capillary remote mounted instrument when temperature of the Media > 180°C

Tower Material

316L Stainless Steel, 304SAS, Monel, Hastelloy B, Hastelloy C, Inconel, Nickel, 316SS, Titanium, Tantalum, Platinum, Zirconium

Diaphragm Material

316L Stainless Steel, 304SAS, Monel, Hastelloy B, Hastelloy C, Inconel, Nickel, 316SS, Titanium, Tantalum, Platinum, Zirconium

Mounting

Directly or Remote capillary mounting

Lower Housing and Flange

316L Stainless Steel, 304SAS, Monel, Hastelloy B, Hastelloy C, Inconel, Nickel, 316SS, Titanium, Tantalum, Platinum, Zirconium

Material

Process Connection

ANSI Flange ½”................5” JIS Flange 15A..............200A DIN Flange DN15........DN200

Rating

ANSI Flange 150LB...2500LB JIS 10K................63K DIN PN2.5..........PN400Bar

Filling Liquid

Silicon oil, Silicon oil high temp, Glycerin, Mineral oil, Vegetable Oil, FDA approved White oil, Halocarbon, Glycerin/Water, Fluorinated oil, Neobee 20, Synthetic Oil Kn77 FDA

Bonded to Housing

Pressure Temperature Level Flowwww.hawkgauge.com.tw

Page 2: HAWK Diaphragm Seals

2

HAWK Diaphragm Seals

P-9ADrawing

Dimensions: G, 1/2" or 1/4" Female or CapillaryInstrument Connection

FlangeProcess Connection Cooling Tower for Temperature>150

Type No: A B DM C G K

1/2"NPT,

1/4 NPT,

G 1/2"

G1/4"

R 1/2"

R 1/4"

M20*1.5

M14*1.0

Female

DS504 1.89"(48mm) 0.98"(25mm)

ANSI-1/2"............5"

Rating-150, 300, 400, 600,

900, 1500, 2500LB

DIN-DN15..........200

Rating-PN2.5-6, 10-40,

64-160, 250-320, 400

JIS-15A............200A

Rating-JIS5K, JIS10K,

20K, 40K, 63K

2.36"(60mm) 1.89"(48mm)

Note: 1. The diaphragm seal with cooling tower is recommended to use for the temperature above 150

applications.

2. The option ushing plug diaphragm seal must be longer around 10mm than standard type.

Double Flange Diaphragm

Pressure Temperature Level Flowwww.hawkgauge.com.tw

Page 3: HAWK Diaphragm Seals

HAWK Diaphragm Seals

P-9A

3

Applicatons

Double Flange Diaphragm

Applications:

Pressure Gauge with Diaphragm Seal

Pressure Switch with Diaphragm Seal

Pressure Transmitter with Diaphragm Seal

Pressure Temperature Level Flowwww.hawkgauge.com.tw

Page 4: HAWK Diaphragm Seals

HAWK Diaphragm Seals

P-9A

4

S 0 F4 2 R504 S

DiaphragmMateria:

E...Hastelloy B H...Hastelloy CO...Inconel M...Monel S...SS 316A...SS 304N...Nickel T...TitaniumU...TantalumQ...PlatinumR...ZirconiumW...SS 316L

Lower Housing Material:

E...Hastelloy B H...Hastelloy CO...Inconel M...Monel S...SS 316A...SS 304N...Nickel T...TitaniumU...TantalumQ...PlatinumR...ZirconiumW...SS 316L

Instrument Conn:

F2-1/2”NPTFemale ThreadF4-1/4"NPTFemale ThreadFD-G 1/2"Female ThreadFE-G 1/4"Female ThreadFJ-M20*1.5Female ThreadFK-M14*1.0Female ThreadG@-Capillaty Connection@=Lengthsuch asG1M= 1m capillary with SS ArmourG3M= 3m capillary withSS ArmourG10M= 10m capillary withSS Armour.......G4F= 4 feet capillary withSS ArmourG10F= 10 feet capillary withSS ArmourG30F= 30 feet capillary withArmour.......

Process FlangeFace:

R-RF(Raise Face)M-LMF(Large Male Face)N-LFF(Large Female Face)O-SMF(Small Male Face)P-SFF(Small Female Face)L-LTF(Large Tongue Face)G-LGF(Large Groove Face)A-STF(Small Tongue Face)B-SGF(Small Groove Face)F-FF(Flat Face)J-RJ(Ring JointFace)K-RFSF(Raise/SmoothFace)

Flushing Conn:

0...Non 4...1/4"NPT Female 8...1/8"NPT Female

P-9A- S

Upper Housing Material:

E...Hastelloy B H...Hastelloy CO...Inconel M...Monel S...SS 316A...SS 304N...Nickel T...TitaniumU...TantalumQ...PlatinumR...ZirconiumW...SS 316L

S

Option:

C-Cooling TowerD-DampenerN-NACE MR0175 TreatmentV-ValveX-Use No OilY-SS Tag Plate

Sealing Liquid:

S-Silicon oil T-Silicon oil High TempG-GlycerineW-Water andGlycerineM-Mineral OilV-Vegetable OilH-Halocarbon F-Fluorinated OilI-FDA approved White oilN-Neobee 20Y-Synthetic Oil KN77 FDA

CH-

ProcessFlangeSize:

1-1/2”(DN15)2-3/4”(DN20)3-1”(DN25)4-1 1/4”(DN32)5-1 1/2”(DN40)6-2”(DN50)

A-DN15B-DN20C-DN25D-DN32E-DN40F-DN50

K-DN15L-DN20M-DN25N-DN32O-DN40P-DN50

ANSI, DIN,HG20615,JIS

HG20592PN0.25, 0.6, 1.0, 2.5, 6.3,10, 16

PN0.4, 1.6,4.0

ProcessFlangeRate:

A-150LBB-300LB C-400LBD-600LBE-900LBF-1500LBG-2500LB

H-PN2.5I-PN4.0J-PN6.0K-PN10L-PN16M-PN25N-PN40O-PN64P-PN100Q-PN160R-PN250S-PN320T-PN400

U-PN 5KV-PN 10KW-PN 20KX-PN 40KY-PN 63K

1-150LB(PN2.0)2-300LB(PN5.0) 3-600LB(PN11)4-900LB(PN15)5-1500LB(PN26)6-2500LB(Pn42)

1-PN0.25, PN0.42-PN0.6 3-PN1.0, 1.64-PN2.5, 4.05-PN6.36-PN107-PN16

ANSI

DIN

JIS

HG20615-97

HG20592-97

A

Order Information

Double Flange Diaphragm

Pressure Temperature Level Flowwww.hawkgauge.com.tw

Page 5: HAWK Diaphragm Seals

5

Limited Warranty and Liability

A. The product has not been subjected to misuse, neglect, abuse , accident, incorrect mounting, improper use or misapplication

such as negligence, accident, vandalism, shock or vibration.

B. The performance of any system of which HAWK's products are a component part.

C. The product has not been exposed to any other service, range or environment of greater severity than that for which the

products were designed.

D. The product has not been altered or repaired by anyone except HAWK GAUGE or its authorized service agencies.

E. The serial number or date code has not been removed, defaced or changed.

Unless otherwise specied in a manual or warranty card, or agree to in a writing signed by HAWK GAUGE ofce, HAWK Process

gauge products shall be warranted for two years from the date of sale.

This warranty is in lieu of all other warranties expressed or implied, and of all obligations or liabilities on its part for damages

including but not limited to consequential damages, following the use of misuse of instruments sold by it. No agent is authorized to

assume for it any liability except as set forth above.

HAWK GAUGE CO.,LTD warrants all its mechanical instruments to be free from defects in materials and workmanship.HAWK agrees

to repair or replace any pressure gauges if returned to our factory, transportation charges prepaid, and after which examination

reveals is to be defective due to faculty workmanship or material.This warrant should not apply to subject to the following terms and

conditions:

F. The actual pressure&temperature occurring exceed the values specied for HAWK Process gauge.

HAWK GAUGE CO.,LTD reserves the right to make product improvements and change its specications at any time stated

throughout this brochure without notication. Please contact the factory on all critical dimensions and specications for verication.

HAWK GAUGE is not expert in the customer's technical eld and therefore doesn't warrant suitability of it's product for the

application selected by customer.

Note

HAWK Diaphragm Seals

P-9A

Double Flange Diaphragm

Pressure Temperature Level Flowwww.hawkgauge.com.tw

GK AUW GA EH

47Anniversary