hh6/8/10 instructions -ledarchitectural high lumen led downlight flangeless trim installation...
TRANSCRIPT
HH6/8/10-LED INSTRUCTIONS
SAFETY INSTRUCTIONS1. Do not use outdoors. 2. Equipment should be mounted securely in locations and at heights where it will not be readily subjectedto tampering by unauthorized personnel. 3. Do not mount near gas or electric heaters. 4. Cap unused wires with enclosed wire nutsor other approved method. 5. Do not use this equipment for anything other than its intended use. 6. The use of accessory
equipment not recommended by the manufacturer will void product listing and warranty and may cause an unsafe condition. 7. Use caution when servicing batteries. 8. Any service on this equipment should be performed by qualified personnel only. 9. Make sure wire terminations are secure and leads are properly tucked in appropriate wire channels. CONSULT A QUALIFIED ELECTRICIAN BEFORE INSTALLING
PAGE 1 OF 4
Catalog# HH6-LED-900L/1200L/1500L/2000L/3000L/4000LO.R.-Revision A: 4/27/20
323-888-1973 [email protected] www.iuseelite.com
Caution: Disconnect AC power before servicing and installation.All electrical connections must be in accordance withNEC/CEC or your local code.
Emergency Driver Mounting
Standard Emergency Mounting Stud Mounting T-Bar Box Hanger
HH6IC-LED
*Insulation Contact is good up to 2000L
Architectural High Lumen LED Downlight
EMG LED Driver
Test Switch J-Box
(J-Box not provided)
Regular
LED Driver
LED Driver Mounting
Insulation
HH6/8/10-LED INSTRUCTIONSPAGE 2 OF 4
Catalog# HH6/8/10-LED-900L/1200L/1500L/2000L/3000L/4000LO.R.-Revision B: 4/27/20
323-888-1973 [email protected] www.iuseelite.com
Emergency LED Driver Bracket Mounting
House Framing Mounting
Joist Mounting
Luminaire 1
T-Bar Mounting
Luminaire 1
Position housing and then secure frame to structure.Adjust it if needed using the self-adjustable locks.
Position housing and then secure frame to structure.Adjust it if needed using the self-adjustable locks.
Self Self Adjustable Locks
1
Integral Test Switch Remote Mount Test Switch
Architectural High Lumen LED Downlight
Emergency Test Switch
1 1
2
SupportBracket
Screw in the Support BracketsMount the Driver Mounting Bracket/J-Box
into the Support Brackets
Driver Mounting Bracket/J-Box
Self-Adjustable Locks
HH6/8/10-LED INSTRUCTIONSPAGE 3 OF 4
Catalog# HH6/8/10-LED-900L/1200L/1500L/2000L/3000L/4000LO.R.-Revision B: 4/27/20
323-888-1973 [email protected] www.iuseelite.com
Flange Trim Installation
Luminaire 2
6 7
Insert the flange trim by squeezing v-spring into the bracket slot
END OF FLANGE TRIM
Install the drywall ceiling and using a router make the hole using the
inside of the rough-in frame as guide
Push up the reflector then rotate it counter clockwise to secure the twist screws into reflector slots. Tighten
both twist screws.
Architectural High Lumen LED Downlight
0-10V Dimming Wiring
Connect all electrical connections.
3 4 5
Place the heatsink momentary on the frame while drywall is install.
2
Wiring Diagram
Luminaire 1
To Additional Luminaires
HH6/8/10-LED INSTRUCTIONSPAGE 4 of 4
Catalog# HH6/8/10-LED-900L/1200L/1500L/2000L/3000L/4000LO.R.-Revision B: 4/27/20
323-888-1973 [email protected] www.iuseelite.com
7
9 10
Insert the flangeless trim by squeezing v-spring into the bracket slot
END OF FLANGELESS TRIM
Apply plaster or spackle over mesh ring. Oncedry sand surface for a finished look.
5
6
Install the drywall ceiling and usinga router make the hole using the
inside of the rough-in frame as guideInsert the mesh ring. Friction blades
will hold it in place.
Apply plaster or spackle over mesh ring. Once dry sand surface for a
finished look.
InsertCover
3 4
8
Place the heatsink momentary on the frame while drywall is install.
Push up the reflector then rotate it counter clockwise to secure the twist screws into reflector slots. Tighten
both twist screws.
Architectural High Lumen LED Downlight
Flangeless Trim Installation (Continuation)
Insert
Cover
HH6/8/10-LED INSTRUCTIONS
SAFETY INSTRUCTIONS1. Do not use outdoors. 2. Equipment should be mounted securely in locations and at heights where it will not be readily subjectedto tampering by unauthorized personnel. 3. Do not mount near gas or electric heaters. 4. Cap unused wires with enclosed wire nutsor other approved method. 5. Do not use this equipment for anything other than its intended use. 6. The use of accessory
equipment not recommended by the manufacturer will void product listing and warranty and may cause an unsafe condition. 7. Use caution when servicing batteries. 8. Any service on this equipment should be performed by qualified personnel only. 9. Make sure wire terminations are secure and leads are properly tucked in appropriate wire channels. CONSULT A QUALIFIED ELECTRICIAN BEFORE INSTALLING
PAGE 1 OF 4
323-888-1973 [email protected] www.iuseelite.com
Caution: Disconnect AC power before servicing and installation.All electrical connections must be in accordance withNEC/CEC or your local code.
Emergency Driver Mounting
Standard Emergency Mounting Stud Mounting T-Bar Box Hanger
HH6-LED-6000L HH6-LED-8000L
LED Driver
LED Driver
6000L/8000L High Lumen LED Downlight
EMG LED Driver
Test Switch J-Box
(J-Box not provided)
Regular
LED Driver
LED Driver Mounting
Catalog# HH6/8/10-LED-6000L/8000LO.R.-Revision A: 4/22/20
HH6/8/10-LED INSTRUCTIONSPAGE 2 OF 4
323-888-1973 [email protected] www.iuseelite.com
Emergency Or Regular LED Driver Bracket Mounting
House Framing Mounting
Joist Mounting
Luminaire 1
T-Bar Mounting
Luminaire 1
Position housing and then secure frame to structure.Adjust it if needed using the self-adjustable locks.
Position housing and then secure frame to structure.Adjust it if needed using the self-adjustable locks.
1
Integral Test Switch Remote Mount Test Switch
6000L/8000L High Lumen LED Downlight
Emergency Test Switch
1 1
2
SupportBracket
Screw in the Support BracketsMount the Driver Mounting Bracket/J-Box
into the Support Brackets
Driver Mounting Bracket/J-Box
Self-AdjustableLocks
Catalog# HH6/8/10-LED-6000L/8000LO.R.-Revision A: 4/22/20
HH6/8/10-LED INSTRUCTIONSPAGE 3 OF 4
323-888-1973 [email protected] www.iuseelite.com
Flange Trim Installation
Flangeless Trim Installation
Luminaire 2
6000L/8000L High Lumen LED Downlight
0-10V Dimming Wiring
Connect all electrical connections.
3 4 5
3 4 5
Install the drywall ceiling and using a router make the hole using the
inside of the rough-in frame as guide
Insert the flange trim by squeezing v-spring into the bracket slot
END OF FLANGE TRIM
Install the drywall ceiling and using a router make the hole using the
inside of the rough-in frame as guide
Insert the mesh ring. Friction blades will hold it in place.
Apply plaster or spackle over mesh ring. Once dry sand surface for a
finished look.
2
Wiring Diagram
InsertCover
Luminaire 1
To Additional Luminaires
Catalog# HH6/8/10-LED-6000L/8000LO.R.-Revision A: 4/22/20
HH6/8/10-LED INSTRUCTIONSPAGE 4 OF 4
Catalog# HH6/8/10-LED-6000L/8000LO.R.-Revision A: 4/22/20
323-888-1973 [email protected] www.iuseelite.com
6 7 8
Insert the flangeless trim by squeezing v-spring into the bracket slot
END OF FLANGELESS TRIMApply plaster or spackle over mesh ring. Once
dry sand surface for a finished look.
6000L/8000L High Lumen LED Downlight
Flangeless Trim Installation (Continuation)
Insert