9
1 HTS-220R connecting with SurvCE 2.62 1.1 Total Station option: 1. Open the total station and find “CNFG”, click F4. 2. Go to “4. Com.para”, then click “ENT” , as showing.

Upload: others

Post on 15-Nov-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Hi-Target...Manual Total Station South Spectra Precision Stonex Direct Stonex Robotic To con Direct Topcon Robotic Trimble Zeiss HI TARGET SurvCE Point ID OPTI OPT2 PT3 1.00 2.00 3.00

1

HTS-220R connecting with SurvCE 2.62

1.1 Total Station option:1. Open the total station and find “CNFG”, click F4.

2. Go to “4. Com.para”, then click “ENT” , as showing.

Page 2: Hi-Target...Manual Total Station South Spectra Precision Stonex Direct Stonex Robotic To con Direct Topcon Robotic Trimble Zeiss HI TARGET SurvCE Point ID OPTI OPT2 PT3 1.00 2.00 3.00

2

3.Open the bluetooth and define the baud rate as “115200”, press F4 for OK.

1.2 SuevCE Options:

1. Open the device->Settings

3.Find Bluetooth->Add new device

Page 3: Hi-Target...Manual Total Station South Spectra Precision Stonex Direct Stonex Robotic To con Direct Topcon Robotic Trimble Zeiss HI TARGET SurvCE Point ID OPTI OPT2 PT3 1.00 2.00 3.00

3

4.Then you will see the Total station in the bluetooth Device.

Choose and click “Next”-> Input the number “1234” in the Passcode.

5.In the Manualacture choose” Topcon Direct”->Model choose “GTS Series”-> Click“√”

Page 4: Hi-Target...Manual Total Station South Spectra Precision Stonex Direct Stonex Robotic To con Direct Topcon Robotic Trimble Zeiss HI TARGET SurvCE Point ID OPTI OPT2 PT3 1.00 2.00 3.00

4

6. Because there is no points, use SurvCE add points by input. As shows.

Choose “Point”->Add.

7. Input the coodinates->“√”, You need to add 3 points at least.

Page 5: Hi-Target...Manual Total Station South Spectra Precision Stonex Direct Stonex Robotic To con Direct Topcon Robotic Trimble Zeiss HI TARGET SurvCE Point ID OPTI OPT2 PT3 1.00 2.00 3.00

5

8. Go to “Survey” and find “Store Points” and you will see the 3 points that you justcreate.

Page 6: Hi-Target...Manual Total Station South Spectra Precision Stonex Direct Stonex Robotic To con Direct Topcon Robotic Trimble Zeiss HI TARGET SurvCE Point ID OPTI OPT2 PT3 1.00 2.00 3.00

6

9.Backsight PT2->Click Backsight

Note: Before go to Backsight, the Total station must turn to measure interface!

10. Set to Zero->click “Set Angle”

Page 7: Hi-Target...Manual Total Station South Spectra Precision Stonex Direct Stonex Robotic To con Direct Topcon Robotic Trimble Zeiss HI TARGET SurvCE Point ID OPTI OPT2 PT3 1.00 2.00 3.00

7

11.Click “Check” ,then click “Check”,then it stars taking reading.

Page 8: Hi-Target...Manual Total Station South Spectra Precision Stonex Direct Stonex Robotic To con Direct Topcon Robotic Trimble Zeiss HI TARGET SurvCE Point ID OPTI OPT2 PT3 1.00 2.00 3.00

8

12. Click “√”then the points collected.

Page 9: Hi-Target...Manual Total Station South Spectra Precision Stonex Direct Stonex Robotic To con Direct Topcon Robotic Trimble Zeiss HI TARGET SurvCE Point ID OPTI OPT2 PT3 1.00 2.00 3.00

9