higher order modes measurements with beam at the ttf linac · 2018. 10. 1. · a recent...

37
O. Napoly LC02, SLAC, Feb. 5, 2002 Higher Order Modes Measurements with Beam at the TTF Linac

Upload: others

Post on 23-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

O. NapolyLC02, SLAC, Feb. 5, 2002

Higher Order Modes Measurements with Beam at the TTF Linac

Page 2: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

TTF MeasurementsA collective effort including most of Saclay, Orsay and DESY

TTF physicists :S. Fartoukh, G. Devanz, C. Magne, M. Jablonka, H.W. Glock, N. Baboi, M. Huening, G. Kreps, M. Liepe,S. Schreiber, H. Weise, M. Wendt ..............

1) TTF Modules : HOMs below cut-off2) Resonant Excitation : Experimental Methods3) Results and Analysis for Dipole Passbands4) Interpretation for the 3rd Dipole Passband

Page 3: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

TTF : Superconducting ModulesFive 8-cavity modules assembled , three modules tested in TTF linac

Page 4: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

TTF : The 3 Measured Modules

DESY

*

*

* *

* Cavities with high-Q, 2.585 MHz mode

Page 5: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

Monopole HOMs

• Monopole HOMs (m=0 , TM0xx ) have a major impact on power dissipation in the HOM coupler (~ 30 W/ module)

• They have a negligible influence on longitudinal dynamics :→ HOM induced multi-bunch energy spread ≈ 2×10-6,

smaller than the spread induced by RF-stabilisation

• Transverse effect through tilted cavities not yet taken into account.

Page 6: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

The Dipole Passbands

propagatingevanescent

• FM

*

*

*

*

ωl / 2π [GHz] (measurement)

(R/Q)l [Ω/cm2] (simulation)

Ql (measurement)

1st dipole passband 1.6506 0.76 7.0⋅104 1.6991 11.21 5.0⋅104 1.7252 15.51 2.0⋅104 1.7545 2.16 2.0⋅104 1.7831 1.75 7.5⋅103

2nd dipole passband 1.7949 0.77 1.0⋅104 1.8342 0.46 5.0⋅104 1.8509 0.39 2.5⋅104 1.8643 6.54 5.0⋅104 1.8731 8.69 7.0⋅104 1.8795 1.72 1.0⋅105

3rd dipole passband (measured since 1998 HOM experiments) 2.5630 1.05 1.0⋅105 2.5704 0.50 1.0⋅105 2.5751 23.80 5.0⋅104

1.8509

The TDR Model

Page 7: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

Emittance Growths : the TDR SituationWith the list of HOMsfrom the TDR, both the single bunchand the multi bunch

emittance growths are small:

δεy/εy < 4%

Assumptions :- 1 MHz frequency spread- 0.5 mm RMS cavity

misalignments- 1st bunch steered through

all quadrupole centres

50 seeds

Emittance growth [%]

Page 8: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

Emittance Growths : 2.590 MHz mode

50 seeds

Design emittance ε0

Multi bunch emittance [µm]

3rd passband 2.590 GHz HOM( R/Q = 23.5 Ω /cm2 , Q = 106 ,

One mode / 8 cavities )

⇒ Multi-bunch emittanceεMB = 0.018 mm·mrd

(on 50 seed average)

⇒ Single-bunch emittanceδεSB/ε0 = 7 %

(only one seed)

Page 9: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

TM011 : HOM Frequency Spread

# Mode

σf [Hz]

R/Q = 150 Ω

Page 10: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

TE111 : HOM Frequency Spread

# Mode

σf [Hz]

R/Q = 15.6 Ω/cm2

Page 11: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

TM110 : HOM Frequency Spread

# Mode

R/Q = 9 Ω/cm2

σf [Hz]

Page 12: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

Resonant Excitation : Experimental Methods

m⋅fb (m+1)⋅fb

fmod fmod bunch harmonics

sidebands

0 20 40 60 80 1000

0.2

0.4

0.6

Bunch number

Cha

rge

[nC

]

HOM

Modulated charge

Resonance HOM / Beam by :1. Cavity detuning : fHOM shifted to mfBeam harmonics⇒ fBeam < tuning range ≈ 1 MHz2. Beam charge modulation fmod → tuneable side-bands

fHOM = m fBeam ± fmod⇒ Brilloin zone [0 , fBeam] as large as possible

Page 13: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

Dipole HOM excitation:Wake Potentials : W ∝ R/Q × r0

mr1m × cos m(θ0 – θHOM ) → HOM Pick

UpW⊥ ∝ R/Q × r0

mr1m–1 ×m cos m(θ0 – θHOM ) → BPM

TTF dogleg magnet operates only in x-plane : δx = ± 2cmmonopole m = 0 : PHOM ∝ δx0 , δxBPM = 0dipole m = 1 : PHOM ∝ δx2 , δxBPM ∝ δxquadrupole m = 2 : PHOM ∝ δx4 , δxBPM ∝ δx3

Page 14: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

High-Q HOM in the 3rd Passband

off resonance on resonance

HOM : f = 2.585 GHz , Q = 106

measured with 216 MHz Injector #1 in Module 1, in 1998.BPM Signal

400 µs

216 MHz beamwith 15 MHz modulation 125 µs beating due to 8 kHz off resonance

Page 15: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

High-Q HOM in the 3rd PassbandFrequency fHOM,, damping Q and "m=1" are easily measured.Coupling R/Q is not: requires beam parameters and polarisation

HOM Pickup SignalHOM at2.585 GHz

35 µsbeam

Beam at 2.6 GHz Decay time ⇒ Q = 106

frequency domain time domain

Page 16: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

High-Q HOM in the 3rd PassbandHOM : f = 2.585 GHz , Q = 4 ×105

measured with 1 MHz Injector #2 in Module 2, in 1999.

HOM Pick Up Signal

= 2576 ×(1.3 GHz/1296)beam harmonics

fHOM = 2584.5 MHz∆f ∼ 50 000 tuner steps

20 bunches

Page 17: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

Results and Analysisfor the Dipole Passbands

The 3rd Dipole Passband :The 2585 MHz identified as the highest frequency HOMwithin the 3rd dipole passband : NOT A SURPRISE !

2π mode at ~ 2×1.3 GHz, synchronous with e– beam⇒ R/Q = 24 Ω/cm2, the highest dipole coupling.

QUESTIONS : why the bad damping , Q > 105 ?why only in 2 out of 8 cavities ?

E field

Page 18: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

Hig

her

Ord

er D

ipol

e Pa

ssba

nd:

Q =

1.7

107

Page 19: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

Goal : Prove or dis-prove the existence of long-lived HOMs,particularly in the 5th dipole passband.

Three Methods : ( f and Q measured with beam)1. Measure R/Q from beam excitation in the BPM : no way,

most BPM signals are triggered by quadrupole modes !2. Identify the position of measured modes in the passband :

very difficult, because the measured passband is a forest !3. Measure R/Q from beam excitation in the HOM couplers :

main unknowns are the polarisations Ki / HOM / x-plane

Page 20: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

Qua

drup

ole

Q1

Pow

erfu

l Qua

drup

ole

HO

Ms a

re c

o-ex

cite

d

Dip

ole

D5

Q=

3.4

107

Page 21: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

The

5thdi

pole

pas

sban

d: m

odul

em

easu

re-

men

tsar

edi

ffic

ultt

oin

terp

ret.

Cav

ity#1

Cav

ity#7

Page 22: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

Benchmarking with TM110-8 @ 1887 MHz

R/Q = 0.16 Ω/cm2, from URMELMode measured in all 8 cavities with N.A.

Q = 3.8 105

Page 23: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

Ass

umin

g:c

os(φ

)=1

and

Pex

t= P

K1

22 d

Bat

tenu

atio

n@

SA

from

(cab

les+

10d

Bat

tenu

ator

)

f C2

–f C

8=

22 K

Hz

Page 24: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

The

mod

es T

M11

0-8

in (C

1-C

6,C

8) a

resp

read

by a

bout

300

kH

z ,

with

mod

e in

C7

abou

t 3M

Hz

belo

w!

Q =

3.8

5 10

5

∆f =

5 k

Hz

Off

reso

nanc

e ca

vity

resp

onse

Page 25: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

The

load

ed c

avity

sign

al @

54

MH

zP n

= U

n2 /(R/

Q×Q

)

The

expo

nent

ial d

ecay

ofth

e em

pty

cavi

tyP

= P N

exp(

-2t/τ

)de

pend

son

num

bero

fbun

ches

N⇒

The

star

toft

he d

ecay

can

be

a bi

thig

her

orm

uch

low

er th

an th

e vi

deo

sign

al

Page 26: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

TM110-5 vs. TM110-8

TM110-5 @ 1874 MHzR/Q = 8.7 Ω/cm2 ,

Q = 1.14×105

⇒ ∆xBPM = 1.75 mm

TM110-8 @ 1887 MHzR/Q = 0.16 Ω/cm2 , Q = 3.85×105

⇒ ∆xBPM = 0.085 mm

Page 27: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

TM110-5 @ 1887 MHz

f-spread = 560 kHz for polar #1 850 kHz for polar #2

Prediction

Page 28: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

5th Dipole Passband Trapped ModePrediction for : f =3068 MHz , R/Q = 1.1 Ω/cm2 , Q = 3.4 107

in cavity C7, as a function of the modulation frequency

Page 29: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

Conclusions for Higher Passbands

No signal (~ 0 dBm = 1 mW) of strong HOMwith low damping (R/Q ≥ 1 Ω/cm2 , Q ≥ 106)

But, no decisive proof that such modes do not exist. Possible explanations for low power signal :

( ~ 40 dBm instead of ~ 0 dBm):

• R/Q 1 Ω/cm2 ⇒ HOM is harmless• Vertical polarisation• Signal is off resonance : |fQ1– fD5| > 100 kHz• Last bunch generates low field across gap

Page 30: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

Necessary ImprovementsImprove BPM resolution (complement with strip-line)

Offset beam horizontally and verticallyCheck linearity for dipole modesMeasure direct pick-up signal of HOM couplers

• dependence on offset• dependence on coupler• dependence on modulation frequency

Measure HOM power for well understood monopolemodes, and compare to predictionVary number of bunches by one unit.

⇒ A complete frequency scan will be very long

Page 31: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

Interpretation of the3rd Dipole Passband Puzzle

A recent (preliminary) calculation by M. Dohlus (DESY)might elucidate the problem of the 3rd dipole passband.

It combines S-parameter andMAFIA type of calculations, a method also developedat the Uty of Rostock.

It is based on the realgeometry of Input andHOM couplers.

Page 32: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

It predicts the correct passband pattern and HOM damping

C46 measurements12 vs. f

Q vs. Φ

Example of cavity with Saclay HOM couplers

Page 33: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

It predicts: • the correct pairing of polarisations,

with high and low HOM damping• the correct shape of s12 through HOM couplers K1-K2

s12 vs. f–– DESY--- Saclay

Page 34: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

It predicts "module modes" extending over the entiremodule, in the case of homogeneous HOM coupler type.

Page 35: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

It predicts a practical solution for reducing Q < 105

Q vs. ΦQ vs. Φ

DESY typeHOM coupler

One coupler is"mirrored"

Page 36: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

Polarisation pattern may not be completely understood

-3 -2,5 -2 -1,5 -1 -0,5 0 0,5 1

Steerer 7INJ1 [A]

Am

pl. [

a.u.

]Mode: 2.5906 GHz /cavity 7

Hal

Val

Example of S28 cavity (module 3) with DESY HOM couplersshowing a vertically polarized HOM at 2590.6 MHz with Q = 6.5 105 :

• vertical polarisation → DESY coupler• f (low Q) < f (high Q) → Saclay coupler

Page 37: Higher Order Modes Measurements with Beam at the TTF Linac · 2018. 10. 1. · A recent (preliminary) calculation by M. Dohlus (DESY) might elucidate the problem of the 3rd dipole

ConclusionsLESSONS

HOM above cut-off may not be contained in a single cavity : → single cavity R/Q is not relevant, because field pattern is changed→ module R/Q not useful for (m=1) modes because orbit not constant.

Although used for f and Q, beam measurements MUST be usedfor measuring beam coupling R/Q and polarisation Φ.

→ requires qualitative improvement in experimental set-up.

CONCLUSIONS

The puzzle of 3rd dipole passband might be explained and cured.

No evidence for dangerous HOM in the other passbands althoughhigh-Q modes exists, especially in the 5th passband