Seismic Performanceof Sheet Metal Deck
Hilti CorporationDr.-Ing. Thomas Engleder
![Page 3: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/3.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 3www.hilti.com
• Introduction• Hilti – Company Overview
• Direct Fastening Technology
• Motivation
• Sheet Metal Decking in North America
• Shear Diaphragm Design
• Shear Diaphragm Testing Facility
• Seismic Behavior of Fastening Points and of Shear Diaphragms
• Summary and Outlook
Agenda
![Page 4: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/4.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 4www.hilti.com
HiltiCompany Overview
![Page 5: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/5.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 5www.hilti.com
● Founded in 1941 in Schaan, Principality of Liechtenstein
● One of the global leading companies in providing products, systems and services to construction professionals
● Located in more than 120 countries on five continents
● More than 21,000 employees● More than 50 nationalities at Group
Headquarters in Schaan● Direct sales model● 2003 winner of the Carl Bertelsmann
Prize for outstanding corporate culture
Hilti – a worldwide presence
![Page 6: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/6.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 6www.hilti.com
Core Trades – Overview
Building construction Civil engineering Mechanical installation
Steel and metal Interior finishing Electrical installation
![Page 7: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/7.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 7www.hilti.com
Fabrication and installation of handrails, stairs, fences, balconies, etc.
Manufacturing & installation of steel structuresFastening steel columns to base
Installation of roofsInstallation of decksInstallation of metal façadesFlat roof insulation
Installation of glass façadesInstallation of frames (windows, doors,…)
Structural Steel Fabrication &
Erection
Roofing / Siding, Sheet Metal, Flat Roof Insulation
Metal Frames,Glas Facades
Metal Work and Other Steel
Steel/Metal Key Applications
![Page 8: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/8.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 8www.hilti.com
Direct Fastening Technology
![Page 9: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/9.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 9www.hilti.com
Direct Fastening (DX) Technology
• Powder or gas actuated nailing• Fastening in concrete and steel• No drilling required
![Page 10: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/10.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 10www.hilti.com
Hilti Piston Principle (no shooting)
• 5 tons of weight• ~60 m/s• one millisecond• 1.5 MW (2,000 hp)• 100…400 J
![Page 11: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/11.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 11www.hilti.com
Anchoring in steel
• Nail displaces steel volume –deformation, friction
• Strong heating of contact zone surface reactions, local welding and brazing
• Local positive locking (knurled surface of nail)
![Page 12: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/12.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 12www.hilti.com
Motivation
![Page 13: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/13.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 13www.hilti.com
Motivation
• Hazard analysis (e.g. earthquakes) gets increased importance.
• Building codes allow reduced seismic loads, provided that the structure is adequately designed as a ductile (energy dissipating) seismic load resisting system (SLRS).
• Many single story buildings are built using a steel roof shear diaphragm, which could then also be used as a SLRS.Currently thick deck is required to fulfill the requirements.
• Mechanical fasteners are key elements in these constructions.
• In the US welding of sheet metal deck is still common practice (~90%).In Canada a significant shift to mechanical fastener is observed.Hilti drives and supports this development also in the US.
• A detailed understanding and analysis of shear diaphragms in general together with optimized fastening technologies allow for a more cost efficient design of structures.
![Page 14: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/14.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 14www.hilti.com
Sheet Metal Decking inNorth America
http://www.us.hilti.com/decking
![Page 15: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/15.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 15www.hilti.com
Application – Roof Deck Diaphragm on Bar Joists
![Page 16: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/16.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 16www.hilti.com
Application – Roof Deck Diaphragm on Bar Joists
![Page 17: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/17.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 17www.hilti.com
Application – Consumables and Tools
bar joist / support
X-ENP19 X-EDNK22 X-EDN19
DX 860 HSN/ENP ST 1800 + SDT 30
S-SLC 01/02 HWH
![Page 18: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/18.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 18www.hilti.com
Current Fastening Technology: Welding
welds
![Page 19: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/19.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 19www.hilti.com
High performing Sheet Metal Fastening Systems
![Page 20: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/20.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 20www.hilti.com
Shear Diaphragm Design
![Page 21: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/21.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 21www.hilti.com
Design Codes
• IBC (International Building Code)
• ICC-ES AC43 (International Code Council Evaluation Service)
• SDI DDM 03 (Steel Deck Institute Diaphragm Design Manual)
• TM 5-809 Seismic Design of Buildings (Tri-Services Manual)
• ASCE 7 (American Society of Civil Engineers)
• AISC (American Institute of Steel Construction)
• AISI Specification (American Iron and Steel Institute)
• CSA S16 (Canadian Standards Association)
• Eurocode 8
• ….
![Page 22: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/22.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 22www.hilti.com
Application – Structural Design for Shear
~90%
![Page 23: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/23.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 23www.hilti.com
Roof Deck Diaphragm Model (SDI)
(SDI = Steel Deck Institute)
![Page 24: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/24.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 24www.hilti.com
Structural Design for Shear – SDI Approach
e.g. pin performance Qf
e.g. screw performance Qs
Lap shear test data System shear resistancecalculated by adding up
the pin & screwperformance Qf and Qs
Generic formula(allows any combination
of fasteners)(SDI = Steel Deck Institute)
![Page 25: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/25.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 25www.hilti.com
Structural Design for Shear – SDI Approach
In general, the design is commonly done using design tables for maximum nominal loads supplied by SDI and deck manufacturers.The performance is based on analytical calculations or on test results.
<= earthquake
![Page 26: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/26.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 26www.hilti.com
AISC Seismic Design - LoadsV = basic seismic base shear load
R = Response Modification Coefficient (reduction factor for applied lateral force)
![Page 27: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/27.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 27www.hilti.com
AISC Seismic Design
[ Source: AISC Seismic Design Manual, 2006 ]
Response ModificationCoefficient
(reduction factor for applied lateral force, greater deformation capacity)
![Page 28: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/28.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 28www.hilti.com
Shear Diaphragm Testing FacilityTesting according to ICC-ES AC43 and AISI S907
![Page 29: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/29.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 29www.hilti.com
Fastening Systems Research LaboratoryCorporate Research & Technology
US-nat.
accred.
council for
LabAccred.
worldwide internat. lab. accred. cooperation
DAP-PL-4106.00
Hilti Test Lab Accreditation
![Page 30: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/30.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 30www.hilti.com
Test Rig Building (Schaan Hilti HQ)
![Page 31: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/31.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 31www.hilti.com
Test Frame
![Page 32: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/32.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 32www.hilti.com
Test Frame – Technical Data
size: 8 x 10 m (24’ x 30’)
variable spans: 1.6, 2.5, 3.3 m (5’ , 7’-6” , 10’)
variable support thickness
static maximum load 700 kN (157’000 lbs)maximum deflection 200 mm (8 inch)
dynamic maximum load 370 kN (90’000 lbs) maximum deflection +/-200mm (8 inch)
![Page 33: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/33.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 33www.hilti.com
Operating Principle (shear load)
![Page 34: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/34.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 34www.hilti.com
Quasi Static and Seismic Test Setup
![Page 35: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/35.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 35www.hilti.com
Seismic/Cyclic Behaviourof Fastening Points under Shear
![Page 36: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/36.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 36www.hilti.com
Source: Hilti, BGVB internal report, 1992
Steel Deck Frame Fastener under Cyclic Loading
![Page 37: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/37.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 37www.hilti.com
Steel Deck Frame Fasteners after Cyclic Loading
Source: INELASTIC SEISMIC RESPONSE OF METAL ROOFDECK DIAPHRAGMS FOR STEEL BUILDING STRUCTURES. Hesham S. Essa, Robert Tremblay and Colin A. Rogers, 12th European Conference on Earthquake Engineering, Paper Reference 482
Weld Screw Powder-Actuated
![Page 38: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/38.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 38www.hilti.com
Seismic Performanceof Shear Diaphragms
![Page 39: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/39.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 39www.hilti.com
Seismic Test Setup
![Page 40: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/40.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 40www.hilti.com
Quasi Static and Seismic Test Setup
4572
4572
Load introduction
2286
2286
9144
C
DB
7315,2
A
Bea
m 1
1
Bea
m 1
0
Beam 9
Beam 5
Beam 1
Beam 7
Beam 3
2286
2286
![Page 41: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/41.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 41www.hilti.com
Seismic Test – Load Protocol
[curve definition by R. Tremblay]
![Page 42: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/42.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 42www.hilti.com
1. StepQuasi Static Pre-TestingTest Results & Failure Modes
![Page 43: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/43.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 43www.hilti.com
Example (Quasi Static Pre-Test)
![Page 44: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/44.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 44www.hilti.com
Controlling Modes
Decking• Global buckling• Local buckling
![Page 45: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/45.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 45www.hilti.com
Controlling modes
Frame Fasteners in shear● Slotting of sheeting due to shear ● Pullout ● Fracture
![Page 46: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/46.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 46www.hilti.com
Controlling Modes Frame Fasteners in tension
• Pullout (predominantly at the end-overlap)
![Page 47: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/47.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 47www.hilti.com
Controlling Modes Sidelap screws
• Tilting, slotting, piling up• Fracture
![Page 48: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/48.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 48www.hilti.com
2. StepSeismic Testing
![Page 49: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/49.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 49www.hilti.com
Seismic Test – Load Protocol
[curve definition by R. Tremblay]
![Page 50: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/50.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 50www.hilti.com
Seismic Test Video
University of Montreal, R. Tremblay
Hilti AG Schaan, FSRL, DFC project
[1:45 / 2:55]
Co-operation partner
![Page 51: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/51.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 51www.hilti.com
Seismic/Cyclic Test Result
cyclic load
X-ENP19@36s7_#12@12_20ga_1/4_5
SDI allowable service load
![Page 52: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/52.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 52www.hilti.com
Observed Failure
![Page 53: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/53.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 53www.hilti.com
Observed Failure
![Page 54: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/54.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 54www.hilti.com
Seismic/Cyclic Test Result
cyclic loadquasi static capacityremaining capacity
X-ENP19@36s7_#12@12_20ga_1/4_5
SDI allowable service load
![Page 55: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/55.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 55www.hilti.com
Seismic/Cyclic Test Energy Dissipation
![Page 56: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/56.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 56www.hilti.com
Test ReproducibilityIdentical tests lead
to same results!
![Page 57: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/57.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 57www.hilti.com
Cyclic protocolCyclic protocol: Ram displacement
Test S 07 and S 08 based on pretest # 63
-140-120-100-80-60-40-20
020406080
100120140
0 30 60 90 120 150 180 210 240 270 300 330
Time (s)
Ram
dis
plac
emen
t [m
m]
![Page 58: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/58.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 58www.hilti.com
Seismic Test Scope
![Page 59: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/59.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 59www.hilti.com
Seismic Load-Deflection Behaviour
![Page 60: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/60.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 60www.hilti.com
Seismic Test Results
![Page 61: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/61.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 61www.hilti.com
Summary & Outlook
![Page 62: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/62.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 62www.hilti.com
Summary and Outlook
• Sheet steel shear diaphragms fastened with mechanical fasteners (nail, screws, etc.) show a ductile behavior under cyclic/seismic loading.
• All tests done show that the remaining diaphragm performance after cyclic/seismic loading exceeds the allowable service load.
• Further testing and analysis in currently ongoing.
• Expectation: Research activities will lead to design provisions, providing the necessary structural safety with the possibility of thinner sheet metal deck, allowing for a lighter, more economical design.
![Page 63: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/63.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 63www.hilti.com
Thankyou!
![Page 64: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/64.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 64www.hilti.com
![Page 65: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/65.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 65www.hilti.com
![Page 66: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/66.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 66www.hilti.com
Key figures for 2007
Sales
Operating result
Net income
Expenditures for researchand development
Employees worldwide (average)
CHF
CHF
CHF
CHF
4,667 million
533 million
422 million
177 million
18,930
![Page 67: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/67.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 67www.hilti.com
We create enthusiasm through innovation
● We want our customers to work efficiently and safely.● We anticipate their future needs by looking over their shoulder.● This is how we discover possibilities for innovation and develop new
and high-quality products.
![Page 68: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/68.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 68www.hilti.com
0306090
120150180210240
2005 2006 2007
Research and development expenses
151177
164
In CHF million
![Page 69: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/69.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 69www.hilti.com
![Page 70: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/70.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 70www.hilti.com
Hilti Siding & Decking Direct Fastening Selector
![Page 71: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/71.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 71www.hilti.com
Hilti Siding & Decking Direct Fastening Selector
![Page 72: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/72.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 72www.hilti.com
![Page 73: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/73.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 73www.hilti.com
Software Tools – Profis DF / Profis DF Dia
![Page 74: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/74.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 74www.hilti.com
![Page 75: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/75.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 75www.hilti.com
Direct fastening: products for decking
High performance deck fastening systems
DX 860-ENP DX 76 PTR
X-ENP
X-EDNK
SDT 30 & ST 1800
S-MS (Speedy screw)
![Page 76: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/76.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 76www.hilti.com
Innovative system solutions
![Page 77: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/77.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 77www.hilti.com
![Page 78: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/78.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 78www.hilti.com
Terminology
![Page 79: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/79.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 79www.hilti.com
Deck Attachment with Arc Spot Welds
• Traditional / Low Cost Material• Quality control highly variable• Slow production rate• Health risks – toxic fume exposure• Weather dependent (rain/snow)• Back stress / worker comp injuries• Deck coating & paint burn-off• Requires 2nd step corrosion protection• Visible vs. effective diameter• Problems with multi-layer thick deck
![Page 80: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/80.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 80www.hilti.com
![Page 81: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/81.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 81www.hilti.com
Application – Metal deck fastening
![Page 82: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/82.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 82www.hilti.com
Fastening of 4 sheet metals
Cross-section of fastening
• Prediction of sheet deformation• Optimization of nail geometry• Analysis of loads on tool and piston• Evaluation of driving forces
![Page 83: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/83.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 83www.hilti.com
Behavior of Roof Deck Diaphragms under Quasi-static Cyclic LoadingJ. Struct. Engrg. Volume 129, Issue 12, pp. 1658-1666 (December 2003) Issue Date: December 2003 Hesham S. Essa1, Robert Tremblay2 and Colin A. Rogers3
1Post-Doctoral Research Associate, Dept. of Civil, Geological, and Mining Engineering, Ecole Polytechnique, Montreal PQ, Canada H3C 3A7. 2 Professor, Dept. of Civil, Geological, and Mining Engineering, Ecole Polytechnique, Montreal PQ, Canada H3C 3A7. 3 Assistant Professor, Dept. of Civil Engineering and Applied Mechanics, McGill Univ., Montreal PQ, Canada H3A 2K6.
A series of 18 large-scale tests was carried out on corrugated cold-formed steel deck diaphragms for single-story buildings to investigate the diaphragm's ability to function as the main source for absorbing earthquake induced energy through inelastic behavior. Tests were performed using a cantilever type configuration for the test setup, in which the steel deck was laid in a horizontal plane. Diaphragm assemblies made with 0.76 and 0.91 mm thick metal deck sheets and with nine combinations of deck-to-frame and deck-to-deck (side lap) fasteners were tested. For each fastening combination, two tests were conducted: monotonic and quasistatic cyclic. Both the strength and failure modes under quasistatic cyclic loading are different from those under monotonic loading. Test results indicate that diaphragms with welded deck-to-frame fasteners without washers have limited ductility and cannot sustain cyclic loading at relatively large displacement amplitudes. The use of mechanical and welded-with-washer deck-to-frame fasteners enhances the strength, ductility and energy dissipation characteristics of the diaphragm considerably.
© 2003 American Society of Civil Engineers
Research Papers on Inelastic, Seismic Performance of Steel Deck Diaphragms with Welds and Mechanical Fasteners
![Page 84: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/84.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 84www.hilti.com
Inelastic Seismic Response of Frame Fasteners for Steel Roof Deck DiaphragmsJ. Struct. Engrg. Volume 129, Issue 12, pp. 1647-1657 (December 2003) Issue Date: December 2003Colin A. Rogers1 and Robert Tremblay2
1Assistant Professor, Dept. of Civil Engineering and Applied Mechanics, McGill Univ., Montreal QC, Canada H3A 2K6. 2Professor, Dept. of Civil, Geological and Mining Engineering, École Polytechnique, Montreal QC, Canada H3T 1J4.
An experimental program was undertaken to investigate the inelastic seismic response of metal deck roofing systems. The load carrying capacity of roof diaphragms for low-rise steel buildings, subjected to lateral loads from wind and/or earthquakes, is directly dependent on the performance of the connections. This paper provides information on the inelastic cyclic response, including load versus displacement hysteresis and energy absorption capacity of 144 deck-to-frame screwed, powder-actuated fastener, and welded connection tests for different steel deck and structure thickness. Powder-actuated fastenerconnections were able to provide the highest energy dissipation results, followed closely by screwed connections. In many cases, the welded connections exhibited significant ultimate capacities, but failed at small displacements, resulting in low energy dissipation values. However, when welds with washers were used, the ductility and energy absorption ability of the connection were substantially improved.
© 2003 American Society of Civil Engineers
Research Papers on Inelastic, Seismic Performance of Steel Deck Diaphragms with Welds and Mechanical Fasteners
![Page 85: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/85.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 85www.hilti.com
Inelastic Seismic Response of Frame Fasteners for Steel Roof Deck DiaphragmsJ. Struct. Engrg. Volume 129, Issue 12, pp. 1647-1657 (December 2003) Issue Date: December 2003Colin A. Rogers1 and Robert Tremblay2
1Assistant Professor, Dept. of Civil Engineering and Applied Mechanics, McGill Univ., Montreal QC, Canada H3A 2K6. 2Professor, Dept. of Civil, Geological and Mining Engineering, École Polytechnique, Montreal QC, Canada H3T 1J4.
…. This paper provides information on the inelastic cyclic response, including load versus displacement hysteresis and energy absorption capacity of 144 deck-to-frame screwed, powder-actuated fastener, and welded connection tests for different steel deck and structure thickness. Powder-actuated fastenerconnections were able to provide the highest energy dissipation results, followed closely by screwed connections. In many cases, the welded connections exhibited significant ultimate capacities, but failed at small displacements, resulting in low energy dissipation values. …
© 2003 American Society of Civil Engineers
Research Papers on Inelastic, Seismic Performance of Steel Deck Diaphragms with Welds and Mechanical Fasteners
![Page 86: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/86.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 86www.hilti.com
Hilti Test Lab Accreditation
![Page 87: Hilti Seismic EPAQ Hels inki 2009 I XST/et · Hilti Seismic EPAQ Hels inki 2009 I XST/et 3 • Introduction • Hilti – Company Overview • Direct Fastening Technology • Motivation](https://reader033.vdocument.in/reader033/viewer/2022041913/5e6879ca6d51ac419c170a3c/html5/thumbnails/87.jpg)
Hilti Seismic EPAQ Helsinki 2009 I XST/et 87www.hilti.com
Seismic Zones