9 Application Separable straight plug designed to connect polymeric insulated cable to cable. Mates with the elbow, straight and branch joint connectors. Up to 24 kV - 200 A 151SP INTERFACE A STRAIGHT PLUG 6/10 (12) kV 6.35/11 (12) kV 8.7/15 (17.5) kV 12/20 (24) kV 12.7/22 (24) kV Technical characteristics • The thick conductive EPDM jacket provides a total safe to touch screen which ensures safety for personnel. • Each straight plug is tested for AC withstand and partial discharge prior to leaving the factory. Design Separable connector comprising: 1. Conductive EPDM insert. 2. Conductive EPDM jacket. 3. Insulating EPDM layer moulded between the insert and the jacket. 4. Type A - 250 A interface as described by CENELEC EN 50180 and 50181. 5. Conductor connector. Separable plug type Voltage Um (kV) Current Ir (A) Conductor sizes (mm 2 ) (for information only) min. max. 151SP K151SP 12 24 200 200 16 16 95 95 5 2 223 mm Dia. 54 mm 4 1 3

Upload: others

Post on 06-Aug-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HV Cable Jointing Nexans Euromold Elastimold HV Screened ... · •Each straight plug is tested for AC withstand and partial discharge prior to leaving the factory. Design Separable

9

ApplicationSeparable straight plugdesigned to connect polymericinsulated cable to cable.Mates with the elbow, straightand branch joint connectors.

Up to 24 kV - 200 A

151SPINTERFACE A

STRAIGHT PLUG

6/10 (12) kV6.35/11 (12) kV8.7/15 (17.5) kV

12/20 (24) kV12.7/22 (24) kV

Technical characteristics• The thick conductive EPDM

jacket provides a total safe totouch screen which ensuressafety for personnel.

• Each straight plug is testedfor AC withstand and partialdischarge prior to leaving thefactory.

DesignSeparable connectorcomprising:1. Conductive EPDM insert.2. Conductive EPDM jacket.3. Insulating EPDM layer

moulded between the insertand the jacket.

4. Type A - 250 A interfaceas described by CENELECEN 50180 and 50181.

5. Conductor connector.

Separableplugtype

VoltageUm(kV)

CurrentIr

(A)

Conductor sizes (mm2)(for information only)

min. max.151SPK151SP

1224

200200

1616

9595

5

2223 mm

Dia.54 mm

4

1

3

michael ryan
New Logo
Page 2: HV Cable Jointing Nexans Euromold Elastimold HV Screened ... · •Each straight plug is tested for AC withstand and partial discharge prior to leaving the factory. Design Separable

10

Kit contentsThe complete (K)151SP straightplug kit comprises the followingcomponents:

The kit also comprises lubricant, wipers,installation instructions and crimp chart.

Straight plug housing(K)151SPH-W

Conductorcontact

151SPC-X

Cableadaptor

11TL

+ + (K)151SP-W-X+11TLstraight plug kit

=

Ordering instructionsSelect the part numberwhich gives the best centringto the cable core insulationdiameter and substitute Xusing table X, according to theconductor size and type.Add a 'K' for use up to 24 kV.

Orderingpart number

Dia. over core insulation (mm)

min. max.

151SP-EB-X+11TL151SP-EF-X+11TL151SP-FA-X+11TL151SP-FAB-X+11TL151SP-FB-X+11TL151SP-FG-X+11TL151SP-GA-X+11TL

151SP-GAB-X+11TL151SP-GB-X+11TL

12.613.314.615.917.218.419.721.022.2

14.916.117.418.719.921.222.523.825.0

Example:The copper wire screened cableis 12 kV, 50 mm2 strandedaluminium with a diameter overcore insulation of 16.9 mm.Order a 151SP-FA-50(K)M-12-2+11TL straight connector kit.

Table X

Table W

For adaptedbail restraints:

see 'Bail restraints andtypical applications'.

For outdoorapplications.

Order: +MWS.

Components can beordered individually.

For use withcopper tape

screened cables.Order: Kit MT.

For use with Alupe orC 33-226 cables.

Please contact ourrepresentative.

For use withother cable types.

Please contact ourrepresentative.

Conductorsizes

(mm²)

Aluminium Copper

DIN hexagonal Deep indent DIN hexagonal

162535507095

-25(K)M-12-235(K)M-12-250(K)M-12-270(K)M-12-295(K)M-12-2

-25KM-12-135KM-12-1

50(K)M-12-170(K)M-12-195(K)M-12-1

16(K)M-11-225(K)M-11-235(K)M-11-250(K)M-11-270(K)M-11-295(K)M-11-2