HYPERTEC UNINTERRUPTIBLE
POWER SUPPLY
USER’S MANUAL SBUPS600VA
SBUPS1000VA SBUPS1500VA
Contents General Safety Instructions 2 Conditions of Use 2 Electrical Safety 3Safe Operating Practices 4Battery Information 6 Introduction 7
Performance 7 Installation Instructions 9 Physical Appearance 10 Front Panel Operational Indicators 11Operation 12 Specification 13 Maintenance 14 Software Installation 15 Load configure reference 19Troubleshooting 20
1
General safety instructions This manual contains important safety instructions that should be followed
during the installation and maintenance of the UPS.
Please read this manual thoroughly before attempting to install or operate
this UPS.
DO NOT under any circumstances attempt to remove the UPS cover.
It may contain hazardous voltages internally that may cause electric
shock. There are no user-serviceable parts inside. For service,
please contact your nominated service agent.
Conditions of Use This equipment is designed for domestic use only. The manufacturer
neither recommends nor knowingly sells this product for use in critical life
support applications.
1. Intended for installation in a controlled environment.
a. The controlled environment should be in accordance
with the requirement of the specification
b. Do not install or operate your UPS in or near water.
c. Do not place UPS on an unstable cart, stand or table.
d. Do not place UPS under direct sunlight or close to
heat emitting sources.
e. Do not place UPS power cord in any area where it may
2
get damaged by heavy objects.
2. Placing magnetic storage media on top of the UPS may result in data
corruption.
3. Your UPS provides conditioned power to connected equipment.
Maximum load must not exceed that shown on the UPS rating label.
If uncertain, contact Legend
Electrical Safety DO NOT under any circumstances attempt to remove the UPS cover.
It may contain hazardous voltages internally that may cause electric
shock. There are no user-serviceable parts inside. For service,
please contact your nominated service agent.
1. The Hypertec UPS will provide a 220~240VAC 1φ(single-phase)rate
power source. Please verify that this model matches your AC mains /
load voltage requirements.
2. The Hypertec UPS must be earthed at all times during operation.
This can be achieved by only connecting the input power chord to a
mains supply socket outlet with an integral earth terminal. A means of
disconnecting the mains supply should be within 2 meters of the
UPS.
3. Output sockets on the UPS are electrically live if the UPS is switched
3
ON, even if the UPS is not plugged in to mains supply. The On/Off
button on the UPS does not electrically isolate the internal parts. To
isolate the UPS, switch the UPS OFF first, then unplug it from the
mains.
4. To reduce the risk of fire, use fuses with the correct rating when
replacing fuses.
5. The UPS relies on your building wiring over-current protection, which
must be rated between 10-16 amperes.
6. When using the communication features on the UPS, ensure the
cabling connected to the USB communication port are kept
separated by at least 25 mm from the power cords to and from the
UPS input and output.
Safe Operating Practices This pluggable type A equipment has factory installed batteries, and hence
may be operated by anyone that has read and understood this manual.
During the installation of this equipment, it should be assured that the sum
of the leakage currents of the UPS and the connected loads does not
exceed 3.5mA.
1. The mains socket outlet that supplies the UPS shall be installed near
the UPS and shall be easily accessible.
2. When replacing batteries, replace with the same type and number of
batteries.
3. Turn off and unplug your UPS before cleaning. Do not use liquid or
4
aerosol cleaners. A dry cloth is recommended to remove dust from
the surface of your UPS.
4. Do not handle any metallic connector before the power has been
disconnected.
5. Turn off and unplug your UPS from the outlet and contact your
nominated service agent if:
o The power cord or plug damaged.
o Liquid has been spilled on the UPS.
o The fuse blows frequently.
o The UPS does not operate even when user follows
the operating instructions.
5
Battery Information 1. CAUTION: Do not dispose of batteries in a fire, the battery may
explode.
2. CAUTION: Do not open or damage the battery or batteries, as
released electrolyte is harmful to the skin and eyes.
3. A battery can present a risk of electric shock and high short circuit
current. The following precaution should be observed when working
on batteries: Remove watches, rings or other metal objects. Use
tools with insulated handles.
4. NOTE. The batteries used in your Hypertec UPS are maintenance
free. This means that you DO NOT need to check the battery fluid
levels. Trying to do so may cause injury to yourself, or may cause a
fault with the battery / UPS.
5. The battery backup runtime is affected by the state of charge of the
batteries, the age of the batteries and general condition of the
batteries.
6
Introduction The Hypertec UPS can instantly switch your computer to emergency
battery backup power and allows you to work through mains power
outages without data loss or downtime. It continuously conditions the
power coming into your computer and provides a power source with
virtually zero interruption.
This UPS is specially designed for PC users and also suitable for
computer peripherals or POS. A microcontroller is used as the main
controller that renders the product an intelligent UPS, capable of
self-protection and fault diagnosis. A built-in AVR function automatically
adjusts itself to maintain a power supply of stable voltage when the utility
power is of high or low voltage. High-performance surge suppression
protects your computer from electrical noise and damaging power surges.
Performance Your Hypertec UPS provides the following high performance features:
• Uninterruptible Power
Protects your data by supplying battery backup when power fails.
• Microcontroller Control
By means of innovative software control programs, the complicated
hardware circuitry is inlaid in the powerful microcontroller. Apart from
reduced size, it also lowers the rate of UPS failure.
• LED Indicators
7
Operational status is indicated by a series of 3 easy to read LED’s.
• Audible Alarms
Actively lets you know if the unit is in battery mode, if the battery is low, or
if there is an over load condition.
• High quality battery
The selection of high quality sealed lead-acid maintenance free batteries
maximises the life span of the battery for prolonged performance and
enhanced economic benefits.
• Automatic Detection
When the UPS is turned ON, it immediately performs an inspection of the
battery capacity.
• Automatic Voltage Regulation
Corrects over and under-voltages, without draining the battery. This
preserves battery resources and ensures your UPS will provide the
optimum runtime and optimum voltage source during a power blackout.
• Surge Protection
Protects hardware from damage due to unexpected power surges.
• Automatic Charge
The UPS charges its battery whenever it is connected to utility power. The
UPS can be in either the ON or OFF mode.
• Auto Restart (Cold Start)
If the UPS has shutdown during a battery backup session due to
discharged batteries, the UPS will automatically restart once mains power
has been restored to supply mains power and recharge the batteries.
8
Installation Instructions 1. Inspection
Inspect the UPS upon receipt. The packaging is recyclable. Save it for
reuse or dispose of it properly. Ensure the UPS is physically undamaged
due to transit.
2. Placement
Install the UPS in a protected area with adequate airflow, and away from
direct sunlight and excessive dust. Do not operate the UPS where the
temperature and humidity is outside the specified limits in the
Specifications Table.
3. Connect to Mains Power
Connect the AC input power cord to a socket outlet to power up the UPS.
The battery in the UPS will lose some charge during shipping and storage.
It will recharge completely after approximately 8 hours of normal operation.
Do not expect full battery run time during this initial recharge period.
4. Connect the loads
Plug the loads into the output sockets on the rear of the UPS. Ensure the
UPS is sized correctly so that the UPS is not run at full load constantly.
Caution: NDO NOT connect a laser printer or plotter to the UPS with other
computer equipment. A laser printer or plotter periodically draws
significantly more power than when idle, and may overload the UPS.
9
Physical Appearance Front Panel
Rear Panel
Item Description
1 On/Off Power Switch
2 LED 1 - GREEN - AC Normal Status LED
3 LED 2 - YELLOW - Battery Charging LED
4 LED 3 - RED – Battery State of charge LED
5 AC Power socket outlets
6 Phone/Fax line Surge Suppressor
7 USB Communications Port
8 Input AC Fuse
9 Input Power Socket with Spare Fuse
1
2
3
4
5
6
7
8
9
10
Front Panel Operational Indicators Front Panel Indicator
LED 1
Green
LED2
Yellow
LED 3
Red
Buzzer Status Operational
Description
OFF ON OFF OFF
UPS OFF.
Mains Normal.
Batteries Charging.
ON ON OFF 2 second Interval
Beeping
UPS ON.
Mains Mode
OFF OFF BLINK Beeping every 5
seconds
Mains not present.
Battery Backup mode
2 beeps per
second i. Low battery Voltage
4 beeps every 2
seconds ii. Overload
OFF OFF ON
Continuous iii. Short-circuit
OFF OFF OFF OFF Batteries Discharged.
Sleep Mode.
11
Operation • Switch On - With the UPS plugged in, press the power switch in to
switch the UPS on. The UPS will perform a self-test each time it
is switched on and the buzzer will beep 2 times.
• Switch Off - By depressing the power switch. UPS will keep charging
batteries.
• Backup (Beeping 1 time every 5 seconds) - When in Backup mode,
the battery illuminates and the UPS emits a beeping sound
every four seconds. Press the power switch to stop the beeping.
The alarm stops when the UPS returns to normal utility mode of
operation
• Low Battery (Beeping 2 times every 1 second) - In Backup mode,
when the battery energy runs low, the UPS beeps rapidly until
the UPS shuts down due to complete battery discharge.
• Overload (Beeping 4 times every 2 seconds) - When the UPS is
overloaded all three LED’s turn on and the buzzer beeps every
1 second. Promptly disconnect non-essential load equipment
from the UPS to eliminate the overload, otherwise, the UPS will
shut off output power. The time for shut-down is determined by
the size of the overload
• NOTE: If the UPS is working in battery mode, DO NOT turn on
any additional loads such as a computer or monitor or
return any loads from sleep mode, otherwise, the UPS may
operate its overload or short circuit protection.
12
Specification Model SBUPS600VA SBUPS1000VA SBUPS1500VA
Rated Output
power 600VA / 360W 1000VA / 600W 1500VA / 750W
Input Characteristics
Rated Input Voltage 230/240V
Input Voltage Range 175 – 285 V
Rated Input Frequency 50 Hz ± 10%
Output Characteristics
Rated Output Voltage 230V ± 10%
Output Frequency 50 Hz ± 10%
Output Waveform Modified Square Wave
Power Factor 0.6
Change Over Time Typ. 0.4ms
Max. 10ms
Battery Information (at 25°C)
Rating 1 x 12Vdc, 7Ah 2 x 12Vdc, 7Ah 2 x 12Vdc, 9Ah
Type Sealed Lead Acid, Maintenance Free
Service Life 2-3 years depending upon use
Battery Recharge time
for 90% capacity 8 hours
Runtime in minutes at
full load ≥ 3 mins
13
General
Audible Noise < 45dBA
Net Mass 6 kg 10.9 kg 12.5 kg
Dimensions(mm) 162×94×320 124×382×225
Operating Temperature -10°C to +40°C
Maximum Operating
Relative Humidity 95% Relative
Maintenance 1. With normal use, a UPS battery will last 2 to 3 years depending on the
number of discharges and operating/ambient temperatures.
2. Charge the UPS's battery every 3 months during extended storage.
3. Disconnect the power during extended storage to avoid overcharge of
the battery.
4. Avoid overload or short circuit even though the UPS has build-in
overload and short circuit protect function.
14
Software Installation In order to utilise the UPS to its full potential, the monitoring software must
first be installed. Please install the software according to the following
steps. For information on how to operate the software, refer to the On-CD
manual
When the software
CD is inserted, The
Autorun screen will
come up.
Click Install.
Click NEXT
15
3. Enter details as
requested on this
screen. Your
product serial
number will be on
the CD envelope.
Click NEXT
4. Choose the
installation
directory.
Click Next.
16
5. Select language.
English is Default.
Click NEXT.
6. Software will
Now Install.
17
7. Installation is
now complete.
Click FINISH
8. The program is
now running.
For information on
how to operate the
software, refer to
the On-CD manual.
18
Load configuration reference
UPS (VA) = PC power ATX (Watt) /0.6 + Monitor (VA)
Monitor power ( reference )
15”CRT 15”LCD 17”CRT 17”LCD 19”CRT 19”LCD
80VA 40VA 130VA 60VA 180VA 80VA
19
Troubleshooting Problem Possible Cause Action To Take
i. Battery Discharged.
Sleep Mode. Press the POWER button ONUPS not on &
No LED’s on ii. PCB failure Contact Service Agent
Power cord lose Re-plug the power cord
Line voltage too high, too
low or black out Normal condition
UPS always at battery
mode
PCB failure Contact Service Agent
i. Short Circuit. Remove the non-critical loadsBuzzer continuously
sounding ii. UPS Faulty Contact Service Agent
UPS does not provide
expected run time. Low
battery warning is
sounded prematurely.
Battery is weak due to
wear or successive mains
outages.
Allow UPS to recharge battery
for a minimum of 8 hours. If
UPS sounds low battery
warning prematurely, when
retested, battery should be
replaced.
20