TRANSCRIPT

Page 1: i0522-249 Condair EL Brochure AW 11-18.qxp Layout 1xposed The robust zinc coated steel elements provide a long operational life. 1 2 3 Replaceable steam cylinders ensure fast and simple

CONDAIR ELElectrode boiler steam humidifierEasy maintenance with replaceable cylinders

Humidification and Evaporative Cooling

Page 2: i0522-249 Condair EL Brochure AW 11-18.qxp Layout 1xposed The robust zinc coated steel elements provide a long operational life. 1 2 3 Replaceable steam cylinders ensure fast and simple

CONDAIR ELElectrode boiler steam humidifier

Intelligent design for quick maintenanceCylinders can be replaced in minutesensuring reliable humidity control andminimal downtime.

Electrode plugsRobust and touch protective electrodeplugs for easy and safe cylinder change.

Long lasting steam cylinderDisposable steam cylinders last up tothree times longer than other modelsdue to advanced water conductivitymanagement and staged electrode use.

Pumped drainRapidly removes water with highmineral content and returns thehumidifier to full output quickly, thusmaintaining humidity control.

Replaceable boiling cylinders make servicing simple

Cleanable cylinders that can be reused multiple times

Replaceable cylinders for quick and easy maintenance

Page 3: i0522-249 Condair EL Brochure AW 11-18.qxp Layout 1xposed The robust zinc coated steel elements provide a long operational life. 1 2 3 Replaceable steam cylinders ensure fast and simple

Steam distribution options

Large output from a single unitThe Condair EL is available with a singlecylinder for outputs up to 45kg/hr anda double cylinder model for outputs ofup to 90kg/hr. Up to four single unitscan be controlled on a master/slaveconfiguration for outputs up to180kg/hr.

Touch screen control panelAdvanced user interface offers detailedoperational control and diagnosticreporting. A USB connection allowsperformance data to be downloadedinto Excel, as well as software updatesto be loaded.

Easy integration into Building Management SystemsStandard connection using ModbusRTU. Option required for LonWorks -Lon standards certified, BACnet MS/TP - master/slave or BACnet IP - BTL certified.

Outdoor enclosure optionVery compact cabinet rated to IP55

The Condair EL electrode boiler steamhumidifier provides hygienic steam for either in-duct or direct airhumidification.

Servicing is simple and quick throughreplacement of the steam cylinderwhen it becomes full of scale. The humidifier is rapidly returned tomaintaining humidity control.

The steam cylinders of the Condair ELlast up to three times longer thansimilar models due to advanced waterquality management and stagedelectrode use. The unit is easy to installand its touch screen controller makes itsimple to use.

Condair EL with fan unitfor direct room humidifi-cation.

Condair EL with steamhose for use in duct.

O U T S TAN

DIN

G QUALITY • V

DE-

CE

RT I

F I E D •

geprüfteSicherheit

DVE

Page 4: i0522-249 Condair EL Brochure AW 11-18.qxp Layout 1xposed The robust zinc coated steel elements provide a long operational life. 1 2 3 Replaceable steam cylinders ensure fast and simple

Advanced water quality management extends cylinder life, whilst saving water and energy

The Condair EL’s steam cylinders last upto three times longer than other similarelectrode boilers’, reducing maintenanceand the cost of consumables.

Water conductivity managementConductivity levels in the steamcylinder are monitored to ensure themineral concentration of the waterremains at an optimal level.

When the conductivity of the waterbecomes too great, the precise volumeof water needed to reduce the minerallevel sufficiently is drained andreplaced with fresh water. This differsfrom other electrode boiler humidifiersthat use a timer controlled drain.

By intelligently monitoringconductivity, precisely controllingmineral levels and minimising waterdrainage, scale build-up is inhibited,extending the cylinder life, and waterconsumption is minimised, which inturn also reduces the energy needed toheat the fresh water.

Staged electrode useOnly the lower sections of theelectrodes are initially submerged inwater. As they become encrusted inscale, the water level rises to submergeclean electrodes. This staged approachto water level control ensures optimaltransfer of current to the waterthroughout the cylinder’s longoperational lifetime, without any dropin performance or efficiency.

Long lasting, high performing steam cylinders

Water levelClean electrodes

Scale encrusted electrodes

Water levelScale forms on the clean electrodes

Water level risesClean electrodes are again exposed

The robust zinc coated steel elements provide a longoperational life.

1

2

3

Page 5: i0522-249 Condair EL Brochure AW 11-18.qxp Layout 1xposed The robust zinc coated steel elements provide a long operational life. 1 2 3 Replaceable steam cylinders ensure fast and simple

Replaceable steam cylinders ensure fast and simple maintenance and minimal downtime

Electrode boilers are an economic,simple and reliable humidificationsystem for in-duct or direct roomhumidification.

Easy to serviceThe Condair EL informs the user when a cylinder is full of scale and needsreplacing. This is a simple and quickprocess of draining the unit, removingthe old cylinder and replacing it with anew one. This straightforwardmaintenance keeps downtime to aminimum and maintains humiditycontrol.

Operates on mains waterElectrode boiler humidifiers operate onmains water without any need for ROwater treatment. This simplifiesinstallation and reduces on-goingwater consumption.

EconomicThe Condair EL has an economic capitalcost yet is an extremely dependablesolution for hygienic steamhumidification.

Benefits of electrode boiler technology

Page 6: i0522-249 Condair EL Brochure AW 11-18.qxp Layout 1xposed The robust zinc coated steel elements provide a long operational life. 1 2 3 Replaceable steam cylinders ensure fast and simple

Touch screen controller for intuitive operational control and advanced reporting

The Condair EL incorporates the latesttouch screen control panel, providingintuitive operation and extensivereporting information.

All operating parameters can be seen ata glance with on-screen featuresoffering the user further informationon operation and detailed trouble-shooting suggestions.

A USB connection allows allperformance data to be recorded andexported into Excel for advanceddiagnostics. Upgrades to software canalso easily be made via the USB port.

BMS connectivity is included asstandard with Modbus RTU, BACnet IPand BACnet MSTP master or slavemode. Optionally BACnet IP certified,MSTP certified or LonWorks certifiedcan be installed.

Control at your fingertips

Operational status, fault and maintenance data isrecorded via USB and can be analysed in Excel.

Page 7: i0522-249 Condair EL Brochure AW 11-18.qxp Layout 1xposed The robust zinc coated steel elements provide a long operational life. 1 2 3 Replaceable steam cylinders ensure fast and simple

Comprehensive range of accessories and options

Drain water coolerTo reduce the temperature of the drainwater to below 60°C, waste water ismixed with fresh water.

Mounting rackAdjustable mounting rack for easyinstallation on-site at different heights.

Cleanable cylinder Scale can be emptied and the cylinderreused multiple times.

Humidity sensors and hygrostatsFull range of in-duct and in-roomsystems to connect to the internal PIcontroller.

Pressure compensation setAllows operation with up to 10,000 Pa duct pressures.

Condair EL options

Fan unitFor direct room humidification of up to45kg/h. The fan unit can be locateddirectly on top of the humidifier or remotely.

Outdoor enclosure IP55 rated cabinet with very smallfootprint and handles for lifting into position.

Short evaporation steam manifold The Optisorp steam manifold offersvery short evaporation distances in AHUs.

Page 8: i0522-249 Condair EL Brochure AW 11-18.qxp Layout 1xposed The robust zinc coated steel elements provide a long operational life. 1 2 3 Replaceable steam cylinders ensure fast and simple

Condair plcArtex Avenue, Rustington, Littlehampton, West Sussex, BN16 3LN, UKTel: +44 (0)1903 850200 - [email protected] - www.condair.co.uk

11/2018

Accesssories

1 Steam distribution system for duct installation 2 Steam distribution hose3 Ventilation unit for direct room humidification4 Condensate hose5 Filter valve

6

1

23

4

5

Technical data

Housing sizes Small Medium Large

Product reference EL 5 EL 8 EL 10 EL 15 EL 20 EL 24 EL 30 EL 35 EL 40 EL 45 EL 50 EL 60 EL 70 EL 80 EL 90

Dimensions WxHxD mm 420 x 670 x 370 530 x 780 x 406 1,000 x 780 x 406

Operating weight kg 40.0 66.0 132.0

Heating voltage Maximum steam output

400V 3Ph 50-60Hz kg/h 5.0 8.0 10.0 15.0 20.0 24.0 30.0 35.0 40.0 45.0 50.0 60.0 70.0 80.0 90.0

230V 1Ph 50-60Hz kg/h 5.0 8.0 10.0 - - - - - - - - - - -

Control voltage 230V 1Ph 50-60Hz

Conformity CE, VDE

Housing sizes 2x Medium Master-Slave 3x Medium Master-Slave 4x Medium Master-Slave

Product reference EL 50 EL 60 EL 70 EL 80 EL 90 EL 105 EL 120 EL 135 EL 152 EL 160 EL 180

Dimensions WxHxD mm 2x 530 x 780 x 406 3x 530 x 780 x 406 4x 530 x 780 x 406

Operating weight kg 132.0 198.0 264.0

Heating voltage Maximum steam output

400V 3Ph 50-60Hz kg/h 2x 25.0 2x 30.0 2x 35.0 2x 40.0 2x 45.0 3x 35.0 3x 40.0 3x 45.0 4x 38.0 4x 40.0 4x 45.0

230V 1Ph 50-60Hz kg/h - - - - - - - - - -

Control voltage 230V 1Ph 50-60Hz

Conformity CE, VDE

Typical system overview

Replaceable steam cylinderInternal PI humidity controllerRemote indication boardAnalog output for signalling actual steam capacityTouch screen control panelSelf-diagnostic system Real-time clockBMS connectivity - Modbus RTU

Options

IP55 rated outdoor enclosureCondair OptiSorp steam distribution systemPressure compensation set up to 10,000 PaHumidity sensors and hygrostatsCondair online remote diagnosticsBMS connectivity - LonWorks -Lon standardscertified, BACnet MS/TP (master/slave) or BACnet IP - BTL certified