icg myride vx group & icg connect technical installation...

7
ICG MyRide VX Group & ICG Connect Technical Installation FAQs ICG MyRide VX Group & ICG Connect Technical Installation FAQs v02 (2017-06-19)

Upload: others

Post on 29-Jan-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

  • ICG MyRide VX Group & ICG Connect Technical Installation FAQs

    ICG MyRide VX Group & ICG Connect Technical Installation FAQs v02 (2017-06-19)

  • ICG My Ride VX Group room setup ICG My Ride VX Group + ICG Connect room setup

    MyrideTablet (incl. wall mount)

    MyrideTablet (incl. wall mount*)

    * Not included in ICG Connect Stand-Alone package. Only included in ICG MyRide VX Group or Group + Connect packages

    Internet

    (Optional)

    Internet

    (Optional)

    HDMI or DVI Cable (Max 10m (33ft))

    Audio Cable(for DVI or external Audio

    system)

    Bikes with ANT+ Consoles

    ICG Customer Training App**

    ICG Customer Training App**

    ** Works with IC5, IC6 and IC7

    HDMI or DVI Cable (Max 10m (33ft))

    (Max 50m (164ft))

    (Max 50m (164ft))

    (Max 50m (164ft))

    (Max 50m (164ft))

    Audio Cable(for DVI or external Audio

    system)

    ICG MyRide VX Group & ICG Connect Technical Installation FAQs v02 (2017-06-19)

  • Ite

    ms

    ICG

    MyR

    ide

    VX

    G

    rou

    pIC

    GM

    yRid

    eV

    X

    Gro

    up

    & IC

    G

    Co

    nn

    ect

    ICG

    Co

    nn

    ect

    ICG

    Co

    nn

    ect

    U

    pgr

    ade

    ^

    AN

    T D

    ata

    Re

    ceiv

    er

    De

    live

    ry

    Re

    spo

    nsi

    bili

    ty*

    Inst

    alla

    tio

    n

    Re

    spo

    nsi

    bili

    ty*

    Po

    siti

    on

    ing

    Re

    spo

    nsi

    bili

    ty*

    Ele

    ctri

    calp

    ow

    er

    Ou

    tle

    t av

    aila

    bili

    ty

    Re

    spo

    nsi

    bili

    ty*

    Co

    nn

    ect

    ivit

    y*

    Co

    mm

    en

    t

    ICG Bikes - - - - - Life Fitness

    Life Fitness

    Customer - Bluetooth, ANT+ IC5, IC6, IC7 bikes

    Media Server

    1 1 1 - - Life Fitness

    Life Fitness

    Customer Customer Audio/Video: HDMI,DVI, headphone jackNetwork: LAN & WIFI

    Power supply included. Electrical Power Outlet needed within 1 meter of product. Creates independent pre-configured WIFI network with Tablets. An additional wall mount and table stand is included. Needs to be temporarily connected to internet when additional content needs to be unlocked (Eg. When upgrading to ICG Connect Upgrade package)^

    Instructor Tablet

    1 1 1 - - Life Fitness

    Life Fitness

    Life Fitness

    Customer WIFI Power supply included. Electrical Power Outlet needed within 1 meter of product. This tablet will be attached to the instructor bike. Auto connects to WIFI network from Media Server.

    2nd Tablet 1 1 - - - Life Fitness

    Life Fitness**

    Customer Customer WIFI Power supply included. Electrical Power Outlet needed within 1 meter of product. This tablet can be attached to the wall or put on a desk etc. with the Tablet Wall Mount. Auto connects to WIFI network from Media Server. **Only when wall mount is installed, otherwise customer responsibility.

    Tablet Wall Mount

    2 2 - - - LifeFitness

    Customer Customer - - For Desk or Wall mount

    Router - 1 1 1 - Life Fitness

    Life Fitness

    Customer Customer LAN (WIFI section not used)

    Power supply included. Electrical Power Outlet needed within 1 meter of product.

    PoE Injector - 2 2 2 1 Life Fitness

    Life Fitness

    Customer Customer LAN Power supply included. Electrical Power Outlet needed within 1 meter of product

    ANT Data Receiver

    - 2 2 2 1 Life Fitness

    Life Fitness**

    Customer - LAN, ANT 2 ANT Receivers for maximum 40 bikes. For every 20 more bikes, 1 additional ANT Data Receiver needs to be installed. ** Only when wall mount is installed, otherwise customer responsibility.

    ANT Data Receiver Wall Mount

    2 2 2 1 Life Fitness

    Customer Customer - - See “ANT Data Receiver Mounting information” page for more details.

    CAT6 Ethernet cables

    - - - - - Customer Customer Customer - - Minimum CAT6 quality. Maximum 50 meter (164ft) cable between each hardware componentAll cables have to have 20cm (7.9 inch) spare length at all hardware positions

    HDMI or DVI cable

    - - - - - Customer Customer Customer - - Maximum cable length = 10 meter (33ft)For longer distances an HDMI extender can be used (customer responsibility*)

    Screen or Projector

    - - - - - Customer Customer Customer Customer HDMI or DVI Additional audio input needed with DVI,As DVI doesn’t include Audio

    Internet - - - - - Customer Customer Customer LAN Strongly suggested (for scheduling & software updates) but optional for the customer. Mandatory during installation when additional content needs to be unlocked (Eg. ICG Connect Upgrade package)^. Minimum Internet bandwidth 1Mbit/s. 6MBit/s recommended

    Smartphone - - - - - End User End User End User - Bluetooth End User can connect his/her smartphone through ICG Training App over Bluetooth to the Bike Console. Bike consoles have no option to charge smartphones.

    Requirements & Responsibilities

    *Any other hardware which is added and used within this setup is the

    complete responsibility of the customer

    ^ To unlock the additional content for this upgrade, the Media Server

    needs to be temporarily connected to internet

    ICG MyRide VX Group & ICG Connect Technical Installation FAQs v02 (2017-06-19)

  • Hardware list

    PoE InjectorPurpose: adds power over Ethernet for ANT Data ReceiverDimensions: 8x5,4x2,4 cm (3.2x2.1x0.9 inch)Power: 100-240V AC 15.4W

    ANT Data Receiver Wall MountPurpose: Secures the ANT Data Receiver to the wall or ceilingDimensions: 12,1*11,9*7 cm (4.8x4.7x2.8 inch)

    ANT Data Receiver (Wasp)Purpose: Connects the Bike Consoles to the ICG Connect systemDimensions: 12,1*11,9*3 cm (4.8x4.7x1.2 inch)Power: Power over Ethernet

    Media ServerPurpose: Content & Audio/Video server, WifiAccess PointPower: 100-240V AC

    RouterPurpose: Network Hub for ICG Connect setupsDimensions: 17,4x3,2x20,0 cm (6.85x1.26x7.87 inch)Power: 100-240V AC

    Instructor TabletPurpose: Remote Control & Screen duplicator for the instructorPower: 100-240V AC

    2nd TabletPurpose: Secondary Tablet for Virtual timetables & Classes controlPower: 100-240V AC

    Tablet Wall MountPurpose: Secures the 2nd

    Tablet to the wall or functions as a Tablet Desk Stand

    ICG BikesRemarks: The Coach by Color & ICG Connect functionalities require either the IC5, IC6 and/or IC7 bikes

    ICG MyRide VX Group & ICG Connect Technical Installation FAQs v02 (2017-06-19)

  • ANT Data Receiver Mounting information • Can be secured on walls (A) or ceiling (B)• The customer is responsible for drilling the holes for the ANT Data Receivers wall

    mounts (use pre-drill template on next page)• 2 ANT Receivers for maximum 40 bikes. For every 20 more bikes, 1 additional ANT

    Data Receiver needs to be installed

    Wall Mount

    Ceiling Mount

    ICG MyRide VX Group & ICG Connect Technical Installation FAQs v02 (2017-06-19)

  • ANT Data Receiver Wall Mount

    • Can be used for wall and ceiling mounting

    • The Wall Mount template can be used for pre-drilling holes prior to when the actual installation will take place

    • The customer is responsible for drilling the holes for the ANT Data Receivers Wall Mounts

    • Real size when printed on A4

    ICG MyRide VX Group & ICG Connect Technical Installation FAQs v02 (2017-06-19)

  • Customer Planning Responsibilities

    Pre Install

    • Plan the position of all hardware

    • Install Network cables

    • Install all Electrical power sockets

    • Facilitate Internet (optional)

    • Pre-drill ANT Data Receiver wall mounts

    @ Install

    • Customer indicates positioning of all hardware to installation team

    • For installs with internet connectivity a customer IT specialist needs to be present to support connectivity setup

    • Unlock additional content (ICG Connect Upgrade package only)

    Post Install

    • If any of the customer responsibilities could not be met at installation, the customer is responsible to initiate the finalization of the installation after the original installation timing (through an additional Installation or Service Request. Additional charges apply)

    © 2017 Life Fitness, a division of Brunswick Corporation. All rights reserved. (ISBU Installation Support-FK) ICG MyRide VX Group & ICG Connect Technical Installation FAQs v02 (2017-06-19)