 www.ingenstech.com  | w w w  . i   g  e  s  t  e  c h  .  c  o   | w w w  . i  n  g  e n  s  t  e  c h  .  c  o   | w w w  . i  n  g  e n  s  t  e  c h  .  c  o m   | w w w  . i   g  e  s  t  e  c h  .  c  o m   | w w w  . i  n  g  e n  s  t  e  c h  .  c  o   |  Industrial Monitoring And Control System  Abstract Very often in an industrial scenario there is a need to monitor the power consumption patterns of individual units or machines. Some rather minor factors can cause huge amounts of unnecessary power consumption, which often go unnoticed and incur huge expenses for industries. This project aims at providing a system with which the power consumption of individual machines can be monitored and recorded, from a central location. In this project an embedded power monitoring device is attached with the machine where the power consumption is to be recorded. The embedded power monitoring device records the power consumption in the unit and periodically transmits the readings using a RF transmitter. The readings from all the monitoring devices can be received with a single receiver and the readings are then transferred to a microcontroller which again displays the information on a computer. Hence the power consumption from all the units can be monitored on a single terminal. The readings can also be displayed on a portable display like a LCD. Apart from the primary purpose of power monitoring this project has extended capability in terms of upper threshold for power consumption. With this feature when a particular unit is consuming very high power or is showing abnormal power consumption, the microcontroller unit automatically disconnects the device, and gives an indication on the computer screen for the users. The embedded system consists of an advanced microcontroller that can communicate with the wireless modem. This immediate transfer of information will result in faster response time by the authorities and the poser shut of time will also be reduced drastically Existing System 1. Unnecessary power consumption due to defect in the machine cannot be monitored accurately. Proposed System 1. An embedded power monitoring device is attached with the machine to record the power consumption in the unit and periodically transmits the readings using a RF transmitter. 2. The power consumption from all the units can be monitored on a single terminal and can be displayed. 3. Whenever an individual unit or a machine consumes abnormal power automatically the power will be disconnected to the device. © Ingens Tech Private Limited | For Students Use Only | All Rights Reserved www.ingenstech.com | IEEE Projects 2014 - 2015 abstracts | Final Year Projects 

Upload: final-year-projects-2014

Post on 02-Jun-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: IEEE Projects 2014 - 2015 Abstracts -Electrical 03

 

  www.ingenstech.com 

 | www .i  n g en s t  e ch  . c om  | www .i  n g en s t  e ch  . c om  | www .i  n g en s t  e ch  . c om  | www .i  n g en s t  e ch  . c om  | www .i  n g en s t  e ch  . c om  | 

 

Industrial Monitoring And Control System

 Abstract

Very often in an industrial scenario there is a need to monitor the power consumption patterns of

individual units or machines. Some rather minor factors can cause huge amounts of unnecessary

power consumption, which often go unnoticed and incur huge expenses for industries. This project

aims at providing a system with which the power consumption of individual machines can be

monitored and recorded, from a central location.

In this project an embedded power monitoring device is attached with the machine where the

power consumption is to be recorded. The embedded power monitoring device records the power

consumption in the unit and periodically transmits the readings using a RF transmitter.

The readings from all the monitoring devices can be received with a single receiver and the readings

are then transferred to a microcontroller which again displays the information on a computer. Hence

the power consumption from all the units can be monitored on a single terminal. The readings can

also be displayed on a portable display like a LCD.

Apart from the primary purpose of power monitoring this project has extended capability in terms of

upper threshold for power consumption. With this feature when a particular unit is consuming very

high power or is showing abnormal power consumption, the microcontroller unit automatically

disconnects the device, and gives an indication on the computer screen for the users. The embedded

system consists of an advanced microcontroller that can communicate with the wireless modem.

This immediate transfer of information will result in faster response time by the authorities and the

poser shut of time will also be reduced drastically

Existing System

1. 

Unnecessary power consumption due to defect in the machine cannot be monitored

accurately.

Proposed System

1.  An embedded power monitoring device is attached with the machine to record the power

consumption in the unit and periodically transmits the readings using a RF transmitter.

2. 

The power consumption from all the units can be monitored on a single terminal and can be

displayed.

3.  Whenever an individual unit or a machine consumes abnormal power automatically the

power will be disconnected to the device.

 

© Ingens Tech Private Limited | For Students Use Only | All Rights Reserved

www.ingenstech.com | IEEE Projects 2014 - 2015 abstracts | Final Year Projects 

Page 2: IEEE Projects 2014 - 2015 Abstracts -Electrical 03

 

  www.ingenstech.com 

 | www .i  n g en s t  e ch  . c om  | www .i  n g en s t  e ch  . c om  | www .i  n g en s t  e ch  . c om  | www .i  n g en s t  e ch  . c om  | www .i  n g en s t  e ch  . c om  | 

 

Block Diagram

ARM / PIC

 A D 

 C 

 U A  R  T 

 

D  A  C 

 P  W M

Power

& Reset

GPIO

ROM

RAM

CLOCK

RF

 U A  R  T 

MODULATION

DEMODULATION

POWER SUPPLY

Power

Adapter

Reverse

Protection

Voltage

Regulators

Power LED

Voltage Sensing

PT Diode

Rectifier

LP

FilterV

Current Sensing

Sensor Diode

Rectifier

LP

FilterA

Relay

Drive

Relay

Load

Device

LCD Module

   S   P   ILCD

Controller

LCD

Display

RF

 U A  R  T 

MODULATION

DEMODULATION

USB to UART Interface

USB Port Converter

IC

UART

Interface

PC

MACHINE MODULE-CONTROL UNIT

PC MODULE-MONITORING UNIT

© Ingens Tech Private Limited | For Students Use Only | All Rights Reserved

www.ingenstech.com | IEEE Projects 2014 - 2015 abstracts | Final Year Projects 

Page 3: IEEE Projects 2014 - 2015 Abstracts -Electrical 03

 

  www.ingenstech.com 

 | www .i  n g en s t  e ch  . c om  | www .i  n g en s t  e ch  . c om  | www .i  n g en s t  e ch  . c om  | www .i  n g en s t  e ch  . c om  | www .i  n g en s t  e ch  . c om  | 

 

Software Tools

•  LPCXpresso IDE / MPLAB IDE

•  EAGLE

•  Orcad

•  Labview

•  Embedded C

Hardware Required

•  ARM LPC11U67 / PIC18F45K22

•  RF Transceivers

•  Current Transformer

•  Potential Transformer

•  LCD Display

•  PC Interfacing

© Ingens Tech Private Limited | For Students Use Only | All Rights Reserved