if you lack the skills, tools or equipment to perform ... · rcp-b (det ca) a/c zone #1 gfi-1 can...

8
Danger of electrical shock, burns or death. Always remove all power sources before aempng any repair, service or diagnosc work. Power can be present from shore power, generator, inverter or baery. All power sources must be disabled and secured before performing any service. If you lack the skills, tools or equipment to perform diagnosc or repair work leave such work to an authorized Winnebago Industries dealer or other qualified shop. Copyright © 2014 Winnebago Industries, Inc.

Upload: doanngoc

Post on 13-Jul-2019

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: If you lack the skills, tools or equipment to perform ... · rcp-b (det ca) a/c zone #1 gfi-1 can (blu) bath pur-2 from load center to galley slideout rcp-2 (blu) 110v connections

Danger of electrical shock, burns or death. Always remove all power sources before attempting any repair, service or diagnostic work. Power can be present from shore power, generator, inverter or battery. All power sources must

be disabled and secured before performing any service.

If you lack the skills, tools or equipment to perform diagnostic or repair work leave such work to an authorized

Winnebago Industries dealer or other qualified shop.

Copyright © 2014 Winnebago Industries, Inc.

Page 2: If you lack the skills, tools or equipment to perform ... · rcp-b (det ca) a/c zone #1 gfi-1 can (blu) bath pur-2 from load center to galley slideout rcp-2 (blu) 110v connections

1.5

265

ALL GROUND WIRE TO BE COVERED WITH TUBING 8041-02-000.

SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.

DRAWING NO.

78J

6

1B1

5

EA

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

ELECTRICAL SYSTEM-50 AMP

1.

MOUNT ATS AS HIGH AS POSSIBLE IN COMPARTMENT.ROUTE GROUND CABLE WITH GENERATOR WIRES THROUGHPANEL & CONNECT TO FRAME RAIL GROUND.

NOTES:

FEATURE

ALL 110V WIRE TO BE CLAMPED WITH CLAMP 10497-05-000WITHIN 200MM OF OUTLET BOXES, USE SCREW G67-10-12B.

1 7

CODES/STANDARDS USA

WIRE PASSES THROUGH FLOOR AT THIS POINT.

2.

A

78J

3.

5

6

14 J37F

RELEASE

186520-12

6

186520

1B1(WHT)TO WATER HEATERFROM LOAD CENTER

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

186520-01

78J

CODES/STANDARDS-CSA/CMVSS

1B1

ATS

2

C

CHKR

PART NO

DSNR

REV

3

P.E.

6

REVISION RECORD

57

D

ALL DIMENSIONS ARE IN MILLIMETERS

A

ANGLE

ORIG. DATE

FIRST USED

D

MATERIAL:

COPYRIGHT 2014WINNEBAGO

INDUSTRIES, INC.

B

4

ZONE

WHOLE DIM (X)

C

REV DWGNO

DATE

THIRD ANGLE

4

DFTR-ORIG

ONE-PLACE (X.X)

DO NOT SCALE DRAWING

26

TWO-PLACE (X.XX)

A

R

8

1

DFTR

5

PROJECTION

DATE

TITLE:

8 REF:

UNSPECIFIED TOLERANCES ARE:

3

REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES

M.E.

7

B

1

REV

OFSHEET

78J

0.50

1000 DROPTO LOAD CENTERBLK,BRN,YEL,PUR,GLD-2,GLD,MAINTO LOAD CENTER

265

1

ALL WIRES TO BE SECURED WITH CLAMP 10495-01-000OR CLIP 80734-01-000 EVERY 600MM. USE SCREWG67-10-12B UNLESS OTHERWISE SPECIFIED.

--------

WATER HEATERJUNCTION BOXCONNECTOR58028-01-000 (2)

186520-16

265

4. SEE WIRING DIAGRAM-BODY,110V FOR ADDITIONAL INFORMATION.

186520WIRING INSTL-BODY,110V

3

7

300 DROP10 GA INVERTER INPUT AND10 GA INVERTER OUPUT CIRCUITSORG ROMEX

300 DROPPUR,YEL,BRN,BLK,GLD-2 & GLDTO GALLEY 110VCONNECTIONSUNDER FLOORDETAIL FA

(BLU) 300 LOOPTO EXT RCP

RCP-2 (BLU)EXT RCP

BRACKET155223-12-CHTSCREWG67-10-08U (3)(MOUNT TO RISERAT DIM SHOWN)

7

GROMMET23942-01-000 (3)

GROMMET23942-01-000

(BLU) 110V CONNECTORMOUNTED HEREDETAIL FB

COVER-WIRE170196-02-CHTSCREWG39-08-12U (2)

LARGE LOOP (BLU)FROM LOAD CENTERTHRU BATH GFI& REAR BATHTO RCP-2 EXT RCP& RT FRT SLIDE110V CONNECTIONSWHT DROPTO LOAD CENTER

AA

MAINTO LOAD CENTER

POWER CORD

GENERATORPOWER CABLE

VIEW AA

CLAMP10497-03-000 (2)SCREWG39-08-12U (2)

PANEL-RECEPTACLE151376-01-CHTSCREWG11-08-12U (4)

45

195COVER-WIRE170196-05-CHTSCREWG39-08-12U (6)

CABLE-GENERATOR,POWER(SUPPLIED W/GENERATOR)ROUTE TO ATS AND REDUCELENGTH FOR PROPER FIT

*1

86

52

0 *

03-Jun-2014

Page 3: If you lack the skills, tools or equipment to perform ... · rcp-b (det ca) a/c zone #1 gfi-1 can (blu) bath pur-2 from load center to galley slideout rcp-2 (blu) 110v connections

265

WIRING INSTL-BODY,110V

5

RCP-2 (PUR-2)A/V PREP

SEE WIRING DIAGRAM-BODY,110V FOR ADDITIONAL INFORMATION.

2.

1B1 78J

4.

ALL WIRES TO BE SECURED WITH CLAMP 10495-01-000OR CLIP 80734-01-000 EVERY 600MM. USE SCREWG67-10-12B UNLESS OTHERWISE SPECIFIED.

2

GFI-1 CAN (BRN)GALLEY

1B1

ELECTRICAL SYSTEM-50 AMP

1.

CODES/STANDARDS USA

186520

78J

RCP-1 (BLK)MICROWAVE

GALLEY SLIDEOUT110V CONNECTIONSBRACKET155223-12-CHTSCREWG67-10-08U (3)(MOUNT TO SLIDEOUT FLOORCENTERED IN CABINETTOUCHING CABINET FACE)DETAIL FA

ROUTE 110V WIRESWITH WATER LINES

NOTES:

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

D

C

1

FIRST USED

8 3

B

28 1

DO NOT SCALE DRAWING

4

4DWGNO

3

TITLE:

C

6

B

7 5

PART NO

2

D

REV

5

AA

6

7

SHEET

WIRE ROUTED THROUGH FLOOR AT THIS POINT.

ALL GROUND WIRE TO BE COVERED WITH TUBING 8041-02-000.3.

CODES/STANDARDS-CSA/CMVSS

5

ALL 110V WIRE TO BE CLAMPED WITH CLAMP 10497-05-000WITHIN 200MM OF OUTLET BOXES, USE SCREW G67-10-12B. 14 J37F

186520

265

GFI-1 US (BRN)GALLEY

RCP-3 (YEL-2)REFRIGERATOR

RCP-2 (BRN)SIDEWALL SP-04

RCP-3 (GLD)WASHER

SP-04

RCP-2 (BLU)REAR BATH

(BLK) FROM SIDEWALLTO 110V CONNECTORDETAIL FA

EC

RCP-2 (BRN)SIDEWALL SP-04

RCP-TV (PUR)SEE WIRING INSTL-TV/DVDFOR ADDITIONAL INFORMATION

RCP-3 (GLD-2)DRYER

SP-04

RCP-2 (PUR-2)BEDROOM TV

*1

86

52

0 *

RCP-2 (BRN)GALLEY

03-Jun-2014

Page 4: If you lack the skills, tools or equipment to perform ... · rcp-b (det ca) a/c zone #1 gfi-1 can (blu) bath pur-2 from load center to galley slideout rcp-2 (blu) 110v connections

GFI-1 US (BLU)BATH

RCP-2 (PUR)BED REAR

DA

2.

ALL GROUND WIRE TO BE COVERED WITH TUBING 8041-02-000.

3

DETAIL CC

78J

110VCONNECTION(PUR)DETAIL DA

ALL WIRES TO BE SECURED WITH CLAMP 10495-01-000OR CLIP 80734-01-000 EVERY 600MM. USE SCREWG67-10-12B UNLESS OTHERWISE SPECIFIED.

CODES/STANDARDS-CSA/CMVSS

SP-04

RCP-1 BED(PUR)

SEE EXTERIOR ENT CTR FOR ADDITIONAL INFORMATION.

7

RCP-2 (PUR)FRONT SDW

RCP-B (DET CA)A/C ZONE #1

GFI-1 CAN (BLU)BATH

PUR-2

FROM LOADCENTER

TO GALLEY SLIDEOUT110V CONNECTIONSRCP-2 (BLU)

LOUNGE

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

D

C

1

FIRST USED

8 3

B

28 1

DO NOT SCALE DRAWING

4

4DWGNO

3

TITLE:

C

6

B

7 5

PART NO

2

D

REV

5

AA

6

7

SHEET

4.

ALL 110V WIRE TO BE CLAMPED WITH CLAMP 10497-05-000WITHIN 200MM OF OUTLET BOXES, USE SCREW G67-10-12B.

PUR-2

6

WIRE IN ROOF.

265

SP-04

78J

WIRE ROUTED THROUGH FLOOR AT THIS POINT.

CODES/STANDARDS USA

1.

NOTES:

LOAD CENTER/ATS ASM184319-02-000

7

186520

186520

110V CONNECTION(PUR)DETAIL DA

265

7

6

7

SEE WIRING DIAGRAM-BODY,110V FOR ADDITIONAL INFORMATION.

TO RCP-B TV'S

8

7

3.

1B1

5

WIRING INSTL-BODY,110V

14 J37F

WIRE IN SIDEWALL.

ELECTRICAL SYSTEM-50 AMP

1B1

RCP-2 (PUR)BED FRONT

(PUR)RCP-EXT TV

8

COVER-WIRE153862-02-CHTSCREWG67-10-12B (4)

1DF

1DF EXT TV ENTERTAINMENT CENTER

RCP-B (DET CD)TV'S

RCP-B (DET CA)A/C ZONE #2

5

FROM LOADCENTER

TO FRONTA/C ZONE#1

DETAIL CB

RCP-B AC ZONE #2(GRN)

DETAIL CA

RCP-B AC ZONE #1(RED)

FROM LOADCENTER

TO REARA/C ZONE #2

SP-04 7

TO 110V CONNECTIONUNDER BED

SEE DETAIL DA

THROW IN #2

PUR-2

RCP-1 (PUR)BED

*1

86

52

0 *

THROW IN #2

DETAIL CD

RCP-B TV'S(PUR)

FROM RCP-1 BED(DET CC) TO RCP-B FRONT

8

03-Jun-2014

Page 5: If you lack the skills, tools or equipment to perform ... · rcp-b (det ca) a/c zone #1 gfi-1 can (blu) bath pur-2 from load center to galley slideout rcp-2 (blu) 110v connections

CODES/STANDARDS-CSA/CMVSS265

265

ELECTRICAL SYSTEM-50 AMP

CODES/STANDARDS USA

186520

78J

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

D

C

1

FIRST USED

8 3

B

28 1

DO NOT SCALE DRAWING

4

4DWGNO

3

TITLE:

C

6

B

7 5

PART NO

2

D

REV

5

AA

6

7

SHEET

14 J37F1B1

1B1

186520

4

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000 WIRING INSTL-BODY,110V

78J

3

CLAMP10495-01-000 (4)SCREWG67-10-12B (4)

USE CONNECTOR-WIRE,NM144283-02-000TO CONNECT TOWIRE FROM SIDEWALL

WIRE FROMSIDEWALL

SLIDEOUT #2WIRE #14

DETAIL DA

CLAMP10497-03-000 (3)SCREWG39-06-12B (3)

SCREWG39-06-24B (8)

110V PUR-2THROW IN #2 FROMRCP-B TV'S TO RCP-1 BEDSEE DETAIL CC & CD

NOTES:

WIRE MUST BE ROUTED THROUGH CLAMPS AS SHOWN.

MAKE LOOP AS SMALL AS POSSIBLE WHEN SLIDEOUT IS COMPLETELY RETRACTED.

1.

3

4 SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.

RUN 12V WIRE ALONG WITH REAR SLIDEOUT WIRE.2.

RCP-1 AIR BED(REF)SEE DET CC

*1

86

52

0 *

03-Jun-2014

Page 6: If you lack the skills, tools or equipment to perform ... · rcp-b (det ca) a/c zone #1 gfi-1 can (blu) bath pur-2 from load center to galley slideout rcp-2 (blu) 110v connections

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

D

C

1

FIRST USED

8 3

B

28 1

DO NOT SCALE DRAWING

4

4DWGNO

3

TITLE:

C

6

B

7 5

PART NO

2

D

REV

5

AA

6

7

SHEET

1B1

186520

CODES/STANDARDS-CSA/CMVSS

ELECTRICAL SYSTEM-50 AMP

14 J37F

265

5

WIRING INSTL-BODY,110V

401

186520

1B1

78J265

INVERTER-DC/AC, 1000 WATT

CODES/STANDARDS USA

VIEW EA

VIEW EB

40A INVERTER-DC/AC WITHOUT

NOTES:

SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.1

1

1

AC OUTPUT10 GA WIREFROM INVERTERBREAKER PANELDETAIL EB

BRACKET ASM-MOUNT,INVERTER176315-10-CHTRIVET113133-01-CHT (4)

INVERTER175386-02-000NUTD39-06-00B (4)

CONNECTOR-WIRE008311-01-000 (5)

AC INPUT10 GA WIREFROM MAINBREAKER PANELDETAIL EB

WIRE ASM-GROUND

POSITIVE BATTERYCABLE CONNECTION

NEGATIVE BATTERYCABLE CONNECTION

1

REMOTE DISPLAYPANEL & AC TEMPSENSOR CONNECTION

*1

86

52

0 *

78J

03-Jun-2014

Page 7: If you lack the skills, tools or equipment to perform ... · rcp-b (det ca) a/c zone #1 gfi-1 can (blu) bath pur-2 from load center to galley slideout rcp-2 (blu) 110v connections

D

C

1

FIRST USED

8 3

B

28 1

DO NOT SCALE DRAWING

4

4DWGNO

3

TITLE:

C

6

B

7 5

PART NO

2

D

REV

5

AA

6

7

SHEET

14 J37F

WIRING INSTL-BODY,110V

186520

1865206

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

ELECTRICAL SYSTEM-50 AMP

265 78J

1B1

265 CODES/STANDARDS-CSA/CMVSS

CODES/STANDARDS USA

78J

1B1

CLAMP10495-01-000 (22)SCREWG39-08-08U (22)

SCREWG39-06-16B (36)

LOCATED UNDERMAIN FLOOR(SEE SHT 1

FOR LOCATION)

LOCATED UNDERGALLEY DRAWERS

(SEE SHT 2FOR LOCATION)

CONNECTOR-WIRE,NM144283-02-000SCREWG39-06-24B (4)

CLAMP10495-01-000 (4)SCREWG67-10-12B (4)

(BLU)SLIDEOUT #3 WIRE #1

DETAIL FB

CONNECTOR-WIRE,NM144283-02-000SCREWG39-06-24B (4)

(BLU)WIRE IN SIDEWALL

(BLU)TO RCP-SIDEWALL LOUNGE

(BLU)FROM RCP-2 EXT

(PUR)FROM LOAD CENTER

(YEL)FROM LOAD CENTER

(BLK)FROM LOAD CENTER

(GLD)FROM LOAD CENTER

(BRN)FROM LOAD CENTER

THROW IN #5(GLD)TO RCP-WASHER

THROW IN #4(YEL)TO RCP-3REFRIGERATOR

THROW IN #1(BRN)TO RCP-2(BDRM & GALLEY GFI

(BLK) WIREFROM SIDEWALLTO MICROWAVE

THROW IN #3(PUR)TO RCP-1BEDROOM TV

(GLD)SLIDEOUT #1 WIRE #5

(BLK)SLIDEOUT #1 WIRE #2

(BRN)SLIDEOUT #1 WIRE #1

(YEL)SLIDEOUT #1 WIRE #4

(PUR)SLIDEOUT #1 WIRE #3

DETAIL FA

CONNECTOR-WIRE,NM144283-02-000SCREWG39-06-24B (4)

(GLD-2)FROM LOAD CENTER

(GLD-2)SLIDEOUT #1 WIRE #6

THROW IN #6(GLD-2)TO DRYER

STACK PUR-2 AND GLD-2 ON BRACKET

*1

86

52

0 *

03-Jun-2014

Page 8: If you lack the skills, tools or equipment to perform ... · rcp-b (det ca) a/c zone #1 gfi-1 can (blu) bath pur-2 from load center to galley slideout rcp-2 (blu) 110v connections

D

C

1

FIRST USED

8 3

B

28 1

DO NOT SCALE DRAWING

4

4DWGNO

3

TITLE:

C

6

B

7 5

PART NO

2

D

REV

5

AA

6

7

SHEET

14 J37F

WIRING INSTL-BODY,110V

186520

186520 *1

86

52

0 *

7

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

110V CONNECTIONUNDER GALLEY

RCP-3REFRIGERATOR

110V CONNECTIONUNDER STOVE

2

BELOW FLOOR.

4

110V CONNECTION(LOCATED UNDER RT FRT ROOM)

RCP-2BED FRONT

5

GFI-1GALLEY 1

1

RCP-2COMPONENT 15

RCP-2BED REAR

ALL OUTLETS DOWN STREAM AND INCLUDING THIS OUTLETARE GROUND FAULT INTERUPT PROTECTED.

RCP-2EXT ENT CTR

RCP-1BEDROOM TV

3

2

110V CONNECTION(LOCATED BEHIND SOFA)

5

110V CONNECTION(LOCATED BELOW BED)

1

110V CONNECTIONSBELOW GALLEY

RCP-2A/V PREP

4 WIRE IN ROOF.

RCP-2EXTERIOR

3

3

RCP-2MAIN TV

3

2

2

RCP-2COMPONENT 2

RCP-2DINETTE

110V CONNECTION(LOCATED BELOW BED)

RCP-2SIDEWALL

FRONT

RCP-B FRONT(LOCATED IN RT

FRONT OVHD)

RCP-2OVHD

RCP-2REAR BATH

WIRE IN SIDEWALL.

GFI-1FRONT BATH

NOTES:

110V CONNECTION(LOCATED BELOW GALLEY)

RCP-2DINETTE 2

5

110V CONNECTION(LOCATED BELOW STOVE)

RCP-1DRYER

110V CONNECTIONSBELOW STOVE

2

SEE WIRING INSTL-TV/DVD FOR ADDITIONAL INFORMATION.

1 RCP-2DINETTE 1

110V CONNECTIONUNDER GALLEY

110V CONNECTIONUNDER STOVE

5

110V CONNECTIONUNDER STOVE2

110V CONNECTIONUNDER GALLEY

RCP-1WASHER14-2

RCP-2EXT TV 1DF

RCP-1 BED(LOCATED UNDER BED)

78J ELECTRICAL SYSTEM-50 AMP

265

1B1

78J

CODES/STANDARDS USA

2651B1

CODES/STANDARDS-CSA/CMVSS

1DF EXT TV ENTERTAINMENT CENTERLINE 1 (BLK) ROUTED THRU THIS CURRENT SENSOR

LINE 2 (RED) ROUTED THRU THIS CURRENT SENSOR6

7

L2

R3

R5

L1

L2

N

R1

R7

L1

FRONTA/C

RCP-BLANK,

ROOFA/C FRT

(LOCATEDIN RTBATHREAR

WALL)

EMSMODULE

7

6

WATERHEATER

WHT

GLD-2

GLD

3

BLK

GEN4X4BOX

6-3

GROUND

RED

6-3

RED

RED

1 BLK

BLKBLK

GENERATOR

8 GRN

GROUND

POWERCORD

12-2 14-2

12-2

4-3

4-3

12-2

14-2

14-2

14-2

14-2

10-2

INVERTER

14-2

MAIN PANEL

FROMINVERTER

14-210-2

TOINVERTER

REARA/C

3 RCP-BLANK,

ROOFA/C RR

(LOCATEDIN RTBATHREAR

WALL)

110V CONNECTIONUNDER STOVE

RCP-1MICROWAVE

2 110V CONNECTIONUNDER GALLEY

GFI-2GALLEY 2

SLIDEOUT #1WIRE #1

SLIDEOUT #3WIRE #1

SLIDEOUT #1WIRE #6

SLIDEOUT #1WIRE #4

THROW IN WIRE #6

3

SLIDEOUT #1WIRE #2

THROW IN WIRE #4

THROW IN WIRE #5

THROW IN WIRE #1

RCP-B TV'S(LOCATED IN RT

BATH REAR WALL)

SLIDEOUT #1WIRE #2

SLIDEOUT #1WIRE #5

SLIDEOUT #2WIRE #1

THROW IN WIRE #

3

03-Jun-2014