ifti firestop submittal · below is a list of model building codes requiring the use of firestop...

41
IFTI Firestop Submittal Project:________________________________________________________________ Architect: ______________________________________________________________ General Contractor: _____________________________________________________ Installing Contractor:_____________________________________________________ Distributor (and Contact): Manufacturer’s Representative: Technical Service 1-949 975 8588 * Fax 1 949 724 8898

Upload: others

Post on 06-Aug-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

IFTI Firestop Submittal

Project:________________________________________________________________

Architect: ______________________________________________________________

General Contractor: _____________________________________________________

Installing Contractor:_____________________________________________________

Distributor (and Contact): Manufacturer’s Representative:

Technical Service 1-949 975 8588 * Fax 1 949 724 8898

Page 2: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

APPROVALS FOR IFTI Firestop PRODUCTS

Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived from one or more of these model codes. IFTI Firestop products and systems meet the through-penetration firestopping requirements of all of these codes.

ICC . . . . . . . International Code Council; International Building Code ICBO . . . . . . International Code of Building Officials; Uniform Building Code NBCC . . . . . National Building Code of Canada NFPA 101 . . National Fire Protection Association Life Safety Code IRC . . . . . . . International Residence Code

Certain cities, counties and states have written their own code requirements which may supersede or supplement model building codes, check with these authorities for approvals.

IFTI Products are UL Classified and conform to the codes and test requirements shown below.

UL 1479 . . . . . . . . . . . . Fire Tests of Through-Penetration Firestops UL 2079 . . . . . . . . . . . . Tests for Fire Resistance of Building Joint Systems ASTM E 1966 . . . . . . . . Standard Test Method for Fire Resistive Joint Systems ASTM E 814 . . . . . . . . . Methods for Fire Tests of Through-Penetration Fire Stops NFPA 101 . . . . . . . . . . . National Fire Protection Association Life Safety Code ASTM E 84 (UL 723) . . Test Method for Surface Burning Characteristics of Building Materials ASTM E 119 (UL 263) . . Method for Fire Tests of Building Construction and Materials ULC CAN4-S115M . . . . Standard Method of Fire Tests of Firestop SystemsASTM E 2307 . . . . . . . . . Standard Test Method for Determining Fire Resistance of Perimeter Fire Barriers Using Intermediate-Scale, Multi-story Test Apparatus

Questions or Additional Information call Technical Service 1-949 975 8588 * Fax 1 949 724 8898

International Fireproof Technology Inc.17528 Von Karman Ave. Irvine, CA 92614Office: 949-975-8588Web Site: www.Painttoprotect.com Email: [email protected]

Page 3: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

FM012 Firestop Putty

Fill, void or cavity material. For use in through-penetration

Firestop systems.

FM012 Firestop Putty

DescriptionFM012 Firestop Putty is an industry leading elastomeric paste, with fast reacting intumescent properties, designed to seal gaps around through- penetrations and block the passage of flame, toxic fumes and smoke. FM012 Firestop Putty’s Listed designs offer exceptional performance and use less product, making it more cost effective than other traditional firestop putties.

FM012 Firestop Putty is used to protect penetrations such as cable bundles, conduits, metallic pipes, plastic pipes, busways and air ducts with up to a 3-hour fire resistance rating.

FM012 is highly intumescent, offers rapid expansion and high volume char, has excellent elasticity, is easy to install and will not sag in vertical applications. Completely halogen and asbestos free, it does not contain organic solvents.

Meets the intent of LEED® VOC environmental air quality requirements.

Applications

Approx. 11.50

Red

11.50 g/L

7-14 days

40° F - 104° F (5° C - 40° C)

-13° F - 176° F (-25° C - 80° C)

50° F - 95° F (10° - 35° C)

24 months

Specifications Specific Density: Color:

VOC:Curing Time: Application Temp: In-Service Temp: Storage Temp: Shelf life: Package: 310 ml/Tube; 25 Tubes/CTN

600 ml/Sausage, 20/CTN5Kgs/Pail, 20Kgs/Pail

Performance: 50+ years HOAC tested

12

Page 4: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

International Fireproof Technology, Inc.17528 Von Karman Ave. Irvine, CA 92614

Office: 949-975-8588Web Site: www.painttoprotect.comEmail: [email protected]

TestingASTM E 814, 2hrs. F and T Rating

UL 1479, 2hrs. F and T Rating L Rating at Ambient - Less than 1 cfm/sq. ft.

FM Approved

ASTM E84 Flame 0 Smoke 25

CNS 14514, 3hrs. Class A

GB 23864

ASTM E662

Installation guide:1. Refer to applicable certification directory or www.paintoprotect.com for

listed assemblies.2. Ensure application area is clean and free of oil, loose dirt, rust or scale

and is dry and frost free.3. Install the correct depth and compression of forming material, if required,

as detailed within the applicable Listed system. Allow for sufficient depth of fill material.

4. Using a caulking gun, trowel or putty knife, apply FM012 into the seams,gaps or voids between the penetrant and edge of annular space.

5. Tool the sealant surface smooth using a putty knife dipped in water,making complete contact with substrates to ensure an airtight/smoketight seal.

6. Clean application tools with water.7. FM012 firestop putty cures by water evaporation. It is not recommended

for use in a wet environment.

FM012 Firestop Putty

13

Page 5: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20161012-R38513 Report Reference R38513

Issue Date 2016-October-12

Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 1 of 1

Issued to: International Fireproof Technology Inc. 17528 Von Karman Ave Irvine, CA 92614

This is to certify thatrepresentative samples of

Duct-wrap Materials

Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate.

Standard(s) for Safety: ANSI/UL 1479, "Fire Tests of Penetration Firestops." Additional Information: See the UL Online Certifications Directory at

www.ul.com/database for additional information

Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Look for the UL Certification Mark on the product. Type INCA Fireproof Blanket FB01-15 for use in Through-Penetration Firestop System Nos. C-BJ-1056, C-BJ-4033, C-BJ-6001, C-BJ-7108, C-BJ-8021, C-BJ-8025.

Page 6: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20161012-R38512 Report Reference R38512

Issue Date 2016-October-12

Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 1 of 2

Issued to: International Fireproof Technology Inc. 17528 Von Karman Ave Irvine, CA 92614

This is to certify thatrepresentative samples of

Firestop Devices

Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate.

Standard(s) for Safety: ANSI/UL 1479, "Fire Tests of Penetration Firestops,"

Additional Information: See the UL Online Certifications Directory at

www.ul.com/database for additional information

Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Look for the UL Certification Mark on the product. Refer to page 2 for more details.

Page 7: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20161012-R38512 Report Reference R38512

Issue Date 2016-October-12

Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 2 of 2

This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. Type INCA Firestop Collar SSCI-X for use in Through-Penetration Firestop System Nos. C-AJ-2542, C-AJ-2543, C-AJ-2545, C-AJ-2710, C-AJ-2711, C-AJ-2763, C-AJ-2764, C-AJ-2765, C-AJ-2766, C-AJ-2768, C-AJ-8203, C-AJ-8224, C-BJ-2031, C-BJ-2032, F-A-2241, F-A-2242, F-A-2262, F-A-2263, F-A-2264, F-A-2265, F-A-2266, F-B-8007, W-L-8080.

Page 8: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20161012-R38511 Report Reference R38511

Issue Date 2016-October-12

Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 1 of 3

Issued to: International Fireproof Technology Inc. 17528 Von Karman Ave Irvine, CA 92614

This is to certify thatrepresentative samples of

Fill, Void or Cavity Materials Fill, Void or Cavity Materials Certified for Canada

Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate.

Standard(s) for Safety: ANSI/UL 1479, "Fire Tests of Penetration Firestops,"

ANSI/UL 2079, "Tests for Fire Resistance of Building Joint Systems," CAN/ULC-S115, "Standard Method of Fire Tests of Firestop Systems."

Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information

Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Look for the UL Certification Mark on the product. Refer to page 2 for more details.

Page 9: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20161012-R38511 Report Reference R38511

Issue Date 2016-October-12

Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 2 of 3

This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. Elastomeric Fire Caulk INSS1186 for use in Joint System Nos. FF-D-1154, FW-D-1100, HW-D-1111, WW-D-1169. Fire Barrier Silicone Sealant INSS2460+ for use in Joint System Nos. FF-S-1033, FW-S-1019, HW-S-1015, WW-S-1035. Fire Barrier Foam US110 for use in Through-Penetration Firestop System Nos. F-A-1141, F-A-2242, F-B-3014, F-B-4004, F-B-7003. Fire Barrier Foam US150 for use in Through-Penetration Firestop System Nos. C-BJ-0027, C-BJ-8025, F-B-0002, F-B-3011, F-B-4003. Fire Barrier Caulk INSS1440 for use in Through-Penetration Firestop System Nos. C-AJ-1635, C-AJ-1636, C-AJ-2709, C-AJ-2710, C-AJ-2711, C-AJ-3326, C-AJ-4101, C-AJ-4102, C-AJ-5350, C-AJ-5351, C-AJ-6045, C-AJ-6046, C-AJ-7159, C-AJ-8224, F-A-2243, F-A-2244, F-B-3014, F-B-4004, F-B-7003. Fire Barrier Silicone Sealant INSS2460 for use in Through-Penetration Firestop System Nos. C-AJ-1605, C-AJ-1624, C-AJ-4097, C-AJ-5331, C-AJ-7142, C-AJ-8203, C-BJ-0028, C-BJ-1056, C-BJ-1057, C-BJ-1060, C-BJ-2031, C-BJ-2032, C-BJ-4033, C-BJ-4036, C-BJ-5016, C-BJ-5019, C-BJ-6001, C-BJ-7004, C-BJ-7108, C-BJ-8021, C-BJ-8023, C-BJ-8025, C-BK-3003, F-A-1141, F-A-2242, F-B-1013, C-AJ-2545, W-L-1430, W-L-5277, W-L-7181, W-L-8080. Intumescent Strip INFS0812 for use in Through-Penetration Firestop System Nos. C-AJ-2542, C-AJ-2654, C-AJ-2709, C-BJ-2043, F-A-2244, F-B-4005. Firestop Sheet FP-02 for use in Through-Penetration Firestop System Nos. C-BJ-8025, F-B-4005, F-B-8007. Firestop Sheet FP-04+ for use in Through-Penetration Firestop System Nos. C-AJ-1605, C-AJ-1636, C-AJ-2711, C-AJ-4101, C-AJ-5331, C-AJ-5351, C-AJ-6046, C-AJ-7142, C-AJ-8203, C-AJ-8224, C-BJ-1060, C-BJ-2032, C-BJ-4036, C-BJ-5019, C-BJ-7004, C-BJ-8023, W-L-1430, W-L-5277, W-L-7181, W-L-8080. FP05 Coated Firestop Board for use in Through-Penetration Firestop System Nos. C-AJ-1624, C-AJ-4097. Moldable Firestop Putty FM011 for use in Through-Penetration Firestop System Nos. C-AJ-2542, C-AJ-2653, C-AJ-2654, C-AJ-2708, C-AJ-4095, C-AJ-8203, C-AJ-8213, C-BJ-2042, C-BJ-2043, C-BJ-4033, C-BJ-4036, C-BJ-8023, C-BJ-8025, F-A-2243, F-B-4005, F-B-8007, W-L-8080.

Page 10: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20161012-R38511 Report Reference R38511

Issue Date 2016-October-12

Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 3 of 3

Firestop Putty FM012 for use in Through-Penetration Firestop System Nos. C-AJ-1619, C-AJ-2653, C-AJ-2654, C-AJ-4095, C-AJ-5355, C-AJ-6043, C-AJ-7146, C-AJ-7147, C-AJ-8213, C-BJ-2042, C-BJ-2043, F-B-4005, F-B-7004. DC-309 Coating for use in Through-Penetration Firestop System Nos. C-AJ-2544, C-BJ-1056, C-BJ-1057, C-BJ-4033, C-BJ-5016, C-BJ-6001, C-BJ-7108, C-BJ-8021, C-AJ-2542, C-AJ-2543. FP-03 INCAWOOL Board for use in Through-Penetration Firestop System Nos. C-BJ-5017, C-BJ-7001, F-A-1141, F-A-2242. CFS01 Mortar for use in Through-Penetration Firestop System Nos. C-AJ-4096, F-A-1142, F-A-2241, F-A-4008, F-A-5048, F-A-6004. GC99-20 Coating for use in Through-Penetration Firestop System Nos. C-AJ-1624, C-AJ-4097.

Page 11: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20161012-R38512 Report Reference R38512

Issue Date 2016-October-12

Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 1 of 2

Issued to: International Fireproof Technology Inc. 17528 Von Karman Ave Irvine, CA 92614

This is to certify thatrepresentative samples of

Firestop Devices Certified for Canada

Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate.

Standard(s) for Safety: CAN/ULC-S115 (2005), "Standard Method of Fire Tests of

Firestop Systems." Additional Information: See the UL Online Certifications Directory at

www.ul.com/database for additional information

Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Look for the UL Certification Mark on the product. Refer to page 2 for more details.

Page 12: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

C E R T I F I C A T E O F C O M P L I A N C E

Certificate Number 20161012-R38512 Report Reference R38512

Issue Date 2016-October-12

Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 2 of 2

This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. Type INCA Firestop Collar SSCI-X firestop device for use in through-penetration firestop systems described in Vol. 2 of the UL Fire Resistance Directory. The specific System Nos. and the applicable rating information are as follows:

System No.

Rating Hr

F FT FH FTH

C-AJ-2763 2 2 2 2

C-AJ-2764 2 2 2 2

C-AJ-2765 2 2 2 2

C-AJ-2766 2 2 2 2

C-AJ-2768 2 2 2 2

F-A-2262 2 2 2 2

F-A-2263 2 2 2 2

F-A-2264 2 2 2 2

F-A-2265 2 2 2 2

F-A-2266 2 2 2 2

+ Vented piping systems described in the UL Fire Resistance Directory are limited to closed piping systems based on the Canadian building code requirements.

++ Vented piping systems described in the UL Fire Resistance Directory are limited to closed piping systems based on the Canadian building code requirements. Closed piping systems described in the UL Fire Resistance Directory are not applicable to the Canadian requirements.

Page 13: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

LISTING INFORMATION OF

International Fireproof Technology - Firestop Systems

SPEC ID: 42759

International Fireproof Technology Inc. 17528 Von Karman Avenue

Irvine, CA 92614

This report is for the exclusive use of Intertek’s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

Report prepared for: Spec Direct (Free User) on 3/5/2018 7:59:54 PM

International Fireproof Technology Inc. | 42759 | Rev: Feb 12 2018 4:14PM | Uncontrolled Copy Page 1 of 79

Page 14: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

This specification covers multiple firestop materials. See below for individual product descriptions.  These products are used in various combinations to achieve the ratings outlined herein.  The details of the specfic combinations required will be found in the representative Design Listings and are summarized in the table below. 1) INFS0812 Intumescent Strip : INFS0812 Intumescent Strip is a 5 mm × 60 mm or 5 mm x 80 mm intumescent strip bonded on one side to aluminum foil. It is intended to be wrapped around combustible penetrants, such as plastic pipe.   2) SSCI Firestop Collar : SSCI Firestop Collar is a stainless steel collar intended to be used in conjunction with INFS0812 Intumescent strip to tightly seal a combustible penetrant. This product is intended for nonmetallic pipe, plastic pipe, and insulated pipes. The collars are wrapped around the pipe and secured with a hose clamp. Sizes are available for 2 in. and up to 12 in. nominal pipe diameters.     3) INSS1440 Fire Barrier Caulk : The INSS1440 Fire Barrier Caulk is a single component, water based acrylic intumescent firestop sealant. It can be applied by caulking gun, trowel, or putty knife. The Fire Barrier Caulk is available in 310 mL tubes, 600 mL Sausages, 1 gallon pails, and 5 gallon pails.   4) FP-04+ Firestop Sheet : FP-04+ is a Firestop Sheet fabricated by bonding intumescent materials to a metal sheet. This product is intended to be used for shielding cable trays, conduit, and HVAC equipment. The Firestop sheet is 2 mm thick, available in sheets of 90 cm × 90 cm.   5) FM011 Moldable Firestop Putty : FM011 Moldable Firestop Putty is a one-part, flexible intumescent putty for use on wall or floor openings. The putty is sold in bars and applied by tearing off the required amount of material and plugging the opening, smoothing by hand to ensure a tight seal. Fire Ratings

Test Standard

Products Included Rating

Design Number

ASTM E814  1,3 T Rating - 60 min., F Rating - 60 min.

 IFT/PF 60-01CAN/ULC

S115 1,3 F Rating - 60 min., FT Rating - 60 min., FH Rating - 60 min., FTH Rating - 60 min.

ASTM E814  1,2,3

T Rating - 59 to 60 min*, F Rating - 60 min. * See Design Listing for Details for each

penetrant composition IFT/PF 60-02

CAN/ULC S115 1,2,3

F Rating - 60 min., FT Rating - 59 to 60 min*., FH Rating - 60 min., FTH Rating - 59 to 60 min*

* See Design Listing for Details for each penetrant composition

ASTM E814  1,3 T Rating - 60 min., F Rating - 60 min.

 IFT/PF 60-03CAN/ULC

S115 1,3 F Rating - 60 min., FT Rating - 60 min., FH Rating - 60 min., FTH Rating - 60 min.

ASTM E814  5 T Rating - 0 min., F Rating - 0 min.

 IFT/PF 60-

Report prepared for: Spec Direct (Free User) on 3/5/2018 7:59:54 PM

International Fireproof Technology Inc. | 42759 | Rev: Feb 12 2018 4:14PM | Uncontrolled Copy Page 2 of 79

Page 15: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

04CAN/ULC S115 5 F Rating - 60 min., FT Rating - 9 min.,

FH Rating - 0 min., FTH Rating - 0 min.

ASTM E814 1,2,3

T Rating - 13 to 60 min*, F Rating - 60 min. * See Design Listing for Details for each

penetrant composition IFT/PF 60-05

CAN/ULC S115 1,2,3

F Rating - 60 min., FT Rating - 13 to 60 min*., FH Rating - 60 min., FTH Rating - 13 to 60 min*

* See Design Listing for Details for each penetrant composition

ASTM E814  1,2,3,4 T Rating - 60 min., F Rating - 60 min.

 IFT/PF 60-06CAN/ULC

S115 1,2,3,4 F Rating - 60 min., FT Rating - 60 min., FH Rating - 60 min., FTH Rating - 60 min.

ASTM E814  1,5 T Rating - 12 min., F Rating - 60 min.

 IFT/PF 60-07CAN/ULC

S115 1,5 F Rating - 60 min., FT Rating - 12 min. FH Rating - 60 min., FTH Rating - 12 min.

ASTM E814  5 T Rating - 46 min., F Rating - 60 min.

 IFT/PF 60-08CAN/ULC

S115 5 F Rating - 60 min., FT Rating - 46 min., FH Rating - 60 min., FTH Rating - 46 min.

ASTM E814  5 T Rating - 60 min., F Rating - 60 min.

 IFT/PF 60-09CAN/ULC

S115 5 F Rating - 60 min., FT Rating - 60 min., FH Rating - 60 min., FTH Rating - 60 min.

ASTM E814  5

T Rating - 0 to 23 min.*, F Rating - 0 to 60 min.* * See Design Listing for Details for each

penetrant composition IFT/PF 60-11

CAN/ULC S115 5

F Rating - 60 min., FT Rating - 16 to 23 min*., FH Rating - 0 to 60 min.*, FTH Rating - 0 to 23

min* * See Design Listing for Details for each

penetrant composition

ASTM E814  5

T Rating - 51 to 54 min.*, F Rating - 60 min. * See Design Listing for Details for each

penetrant composition IFT/PF 60-12

CAN/ULC S115 5

F Rating - 60 min., FT Rating - 51 to 54 min*., FH Rating - 60 min., FTH Rating - 51 to 54 min*

* See Design Listing for Details for each penetrant composition

ASTM E814  3 T Rating - 60 min., F Rating - 60 min.

Report prepared for: Spec Direct (Free User) on 3/5/2018 7:59:54 PM

International Fireproof Technology Inc. | 42759 | Rev: Feb 12 2018 4:14PM | Uncontrolled Copy Page 3 of 79

Page 16: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

 IFT/PF 60-13CAN/ULC

S115 3 F Rating - 60 min., FT Rating - 60 min., FH Rating - 60 min., FTH Rating - 60 min.

ASTM E814  1,3 T Rating - 120 min., F Rating - 120 min.

 IFT/PF 120-01CAN/ULC

S115 1,3 F Rating - 120 min., FT Rating - 120 min., FH Rating - 120 min., FTH Rating - 120 min.

ASTM E814  1,2,3

T Rating - 102 to 120 min*, F Rating - 120 min. * See Design Listing for Details for each

penetrant composition

 IFT/PF 120-02

CAN/ULC S115 1,2,3

F Rating - 120 min., FT Rating - 102 to 120 min*.,

FH Rating - 120 min., FTH Rating - 102 to 120 min*

* See Design Listing for Details for each penetrant composition

ASTM E814  1,3 T Rating - 120 min., F Rating - 120 min.

 IFT/PF 120-03CAN/ULC

S115 1,3 F Rating - 120 min., FT Rating - 120 min., FH Rating - 120 min., FTH Rating - 120 min.

ASTM E814  5

T Rating - 27 to 120 min*, F Rating - 120 min. * See Design Listing for Details for each

penetrant composition IFT/PF 120-04

CAN/ULC S115 5

F Rating - 120 min., FT Rating - 27 to 120 min*., FH Rating - 120 min., FTH Rating - 27 to 120

min* * See Design Listing for Details for each

penetrant composition

ASTM E814  1,2,3 T Rating - 0 min., F Rating - 0 min.

 IFT/PF 120-05CAN/ULC

S115 1,2,3 F Rating - 120 min., FT Rating - 104 min., FH Rating - 0 min., FTH Rating - 0 min.

ASTM E814  1,2,3,4 T Rating - 101 min., F Rating - 120 min.

 IFT/PF 120-06CAN/ULC

S115 1,2,3,4 F Rating - 120 min., FT Rating - 101 min., FH Rating - 120 min., FTH Rating - 101 min.

ASTM E814  5 T Rating - 16 min., F Rating - 120 min.

 IFT/PF 120-

Report prepared for: Spec Direct (Free User) on 3/5/2018 7:59:54 PM

International Fireproof Technology Inc. | 42759 | Rev: Feb 12 2018 4:14PM | Uncontrolled Copy Page 4 of 79

Page 17: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

08CAN/ULC S115 5 F Rating - 120 min., FT Rating - 16 min.,

FH Rating - 120 min., FTH Rating - 16 min.ASTM E814  5 T Rating - 120 min., F Rating - 120 min.

 IFT/PF 120-09CAN/ULC

S115 5 F Rating - 120 min., FT Rating - 120 min., FH Rating - 120 min., FTH Rating - 120 min.

ASTM E814  1,2,3 T Rating - 120 min., F Rating - 120 min.

 IFT/PF 120-10CAN/ULC

S115 1,2,3 F Rating - 120 min., FT Rating - 120 min., FH Rating - 120 min., FTH Rating - 120 min.

ASTM E814  5

T Rating - 12 to 24 min.*, F Rating - 120 min. * See Design Listing for Details for each

penetrant composition IFT/PF 120-11

CAN/ULC S115 5

F Rating - 120 min., FT Rating - 12 to 24 min*., FH Rating - 120 min., FTH Rating - 12 to 24

min* * See Design Listing for Details for each

penetrant composition

ASTM E814  5

T Rating - 68 to 91 min*, F Rating - 120 min. * See Design Listing for Details for each

penetrant composition IFT/PF 120-12

CAN/ULC S115 5

F Rating -120 min., FT Rating - 68 to 91 min*., FH Rating - 120 min., FTH Rating - 68 to 91

min* * See Design Listing for Details for each

penetrant compositionASTM E814  3 T Rating - 120 min., F Rating - 120 min.

 IFT/PF 120-13CAN/ULC

S115 3 F Rating - 120 min., FT Rating - 120 min., FH Rating - 120 min., FTH Rating - 120 min.

ASTM E814  1,3 T Rating - 120 min., F Rating - 120 min.

 IFT/PF 120-14CAN/ULC

S115 1,3 F Rating - 120 min., FT Rating - 120 min., FH Rating - 120 min., FTH Rating - 120 min.

ASTM E814  1,3 T Rating - 120 min., F Rating - 120 min.

 IFT/PF 120-15CAN/ULC

S115 1,3 F Rating - 120 min., FT Rating - 120 min., FH Rating - 120 min., FTH Rating - 120 min.

ASTM E814  1,3

T Rating - 0 to 120 min*, F Rating - 0 to 120 min.*

* See Design Listing for Details for each penetrant composition

Report prepared for: Spec Direct (Free User) on 3/5/2018 7:59:54 PM

International Fireproof Technology Inc. | 42759 | Rev: Feb 12 2018 4:14PM | Uncontrolled Copy Page 5 of 79

Page 18: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

 IFT/PF 120-16

CAN/ULC S115 1,3

F Rating -120 min., FT Rating - 118 to 120 min*.,

FH Rating - 0 to 120 min.*, FTH Rating - 0 to 120 min*

* See Design Listing for Details for each penetrant composition

ASTM E814  1,2,3,4 T Rating - 120 min., F Rating - 120 min.

 IFT/PF 120-17CAN/ULC

S115 1,2,3,4 F Rating - 120 min., FT Rating - 120 min., FH Rating - 120 min., FTH Rating - 120 min.

ASTM E814  1,2,3,4 T Rating - 120 min., F Rating - 120 min.

 IFT/PF 120-18CAN/ULC

S115 1,2,3,4 F Rating - 120 min., FT Rating - 120 min., FH Rating - 120 min., FTH Rating - 120 min.

ASTM E814  1,2,5 T Rating - 120 min., F Rating - 120 min.

 IFT/PF 120-19CAN/ULC

S115 1,2,5 F Rating - 120 min., FT Rating - 120 min., FH Rating - 120 min., FTH Rating - 120 min.

ASTM E814  3 T Rating - 0 min., F Rating - 0 min.

 IFT/PF 120-20CAN/ULC

S115 3 F Rating - 120 min., FT Rating - 18 min., FH Rating - 0 min., FTH Rating - 0 min.

ASTM E814  1,3 T Rating - 82 min., F Rating - 120 min.

 IFT/PF 120-21CAN/ULC

S115 1,3 F Rating - 120 min., FT Rating - 82 min., FH Rating - 120 min., FTH Rating - 82 min.

ASTM E814  4 T Rating - 120 min., F Rating - 120 min.

 IFT/PF 120-22CAN/ULC

S115 4 F Rating - 120 min., FT Rating - 120 min., FH Rating - 120 min., FTH Rating - 120 min.

Attribute Value

Criteria CAN / ULC S115 (2011)

Criteria ASTM E814-13a (2017)

CSI Code 07 84 00 Firestopping

CSI Code 07 84 13 Penetration Firestopping

CSI Code 07 00 00 Thermal and Moisture Protection

Intertek Services Certification

Listed or Inspected LISTED

Listing Section FIRESTOP SYSTEMS

Report prepared for: Spec Direct (Free User) on 3/5/2018 7:59:54 PM

International Fireproof Technology Inc. | 42759 | Rev: Feb 12 2018 4:14PM | Uncontrolled Copy Page 6 of 79

Page 19: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

Report Number G102547524

Spec ID 42759

Report prepared for: Spec Direct (Free User) on 3/5/2018 7:59:54 PM

International Fireproof Technology Inc. | 42759 | Rev: Feb 12 2018 4:14PM | Uncontrolled Copy Page 7 of 79

Page 20: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

LISTING INFORMATION OF

International Carbide Technologies - Joint Systems

SPEC ID: 43422

International Carbide Technology Co., Ltd. No. 250, SEC., 2, Youguan Road, Lu-Chu District

Taoyuan, 33851 Taiwan

This report is for the exclusive use of Intertek’s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

Report prepared for: Spec Direct (Free User) on 3/5/2018 1:57:41 PM

International Carbide Technology Co., Ltd. | 43422 | Rev: Mar 1 2018 11:33AM | Uncontrolled Copy Page 1 of 18

Page 21: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

This specification coveres multiple firestop materials manufactured by International Carbide Technologies. See below for individual product descriptions.  These products are used, in various combinations to achieve the ratings outline herein.  The details of the specfic combinations required will be found in the representative Design Listings and is summarized in the table below. INSS1186 Elastomeric FireCaulk : INSS1186 Elastomeric FireCaulk is a water based acrylic elastomeric resin material for use on joint systems or firestops. It can be applied by brush, caulking gun, trowel, or airless sprayer. The FireCaulk is available in 310 mL tubes, 1-gallon pails, and 5-gallon pails. FIRE RATINGS

Test Standard

Products Included Rating

Design Number

ASTM E1966,  1 T Rating - 120 min., F Rating - 120 min.

 ICT/JF 120-01CAN/ULC

S115 1 F Rating - 120 min., FT Rating - 120 min., FH Rating - 120 min., FTH Rating - 120 min.

ASTM E1966,  1 T Rating - 120 min., F Rating - 120 min.

 ICT/JF 120-02CAN/ULC

S115 1 F Rating - 120 min., FT Rating - 120 min., FH Rating - 120 min., FTH Rating - 120 min.

ASTM E1966,  1 T Rating - 120 min., F Rating - 120 min.

 ICT/JF 120-03CAN/ULC

S115 1 F Rating - 120 min., FT Rating - 120 min., FH Rating - 120 min., FTH Rating - 120 min.

ASTM E1966,  1 T Rating - 120 min., F Rating - 120 min.  ICT/JF 120-

04CAN/ULC S115 1 F Rating - 120 min., FT Rating - 120 min.,

FH Rating - 120 min., FTH Rating - 120 min.ASTM

E1966,  1 T Rating - 120 min., F Rating - 120 min. ICT/JF 120-05CAN/ULC

S115 1 F Rating - 120 min., FT Rating - 120 min., FH Rating - 120 min., FTH Rating - 120 min.

ASTM E2307 1 T Rating - 148 min., F Rating - 180 min.

 ICT/BPF 180-01

Attribute Value

Criteria CAN / ULC S115 (2011)

Criteria ASTM E2307 (2015)

Criteria ASTM E1966 (2015)

CSI Code 07 84 43 Fire-Resistant Joint Sealants

CSI Code 07 00 00 Thermal and Moisture Protection

Report prepared for: Spec Direct (Free User) on 3/5/2018 1:57:41 PM

International Carbide Technology Co., Ltd. | 43422 | Rev: Mar 1 2018 11:33AM | Uncontrolled Copy Page 2 of 18

Page 22: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

CSI Code 07 84 53 Building Perimeter Firestopping

Intertek Services Certification

Listed or Inspected LISTED

Listing Section EXPANSION/SEISMIC JOINTS

Report Number G102547524; G103082499

Spec ID 43422

Report prepared for: Spec Direct (Free User) on 3/5/2018 1:57:41 PM

International Carbide Technology Co., Ltd. | 43422 | Rev: Mar 1 2018 11:33AM | Uncontrolled Copy Page 3 of 18

Page 23: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

DRAWING INDEX

Certificate of Compliance - International Carbide Technologies - Joint Systems

ICT/BPF 180-01

ICT/JF 120-01

ICT/JF 120-02

ICT/JF 120-03

ICT/JF 120-04

ICT/JF 120-05

Report prepared for: Spec Direct (Free User) on 3/5/2018 1:57:41 PM

International Carbide Technology Co., Ltd. | 43422 | Rev: Mar 1 2018 11:33AM | Uncontrolled Copy Page 4 of 18

Page 24: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

Certificate of Compliance - International Carbide Technologies - Joint Systems

www.intertek.com The certificate and schedule are held in force by regular annual surveillance visits by Intertek Testing Services NA, Inc. and the reader or user should contact Intertek to validate its status. This certificate remains the property of Intertek Testing Services NA, Inc. and must be returned to them on demand. This Certificate is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this certificate. Only the Client is authorized to permit copying or distribution of this certificate and then only in its entirety. Use of Intertek’s Certification mark is restricted to the conditions laid out in the agreement. Any further use of the Intertek name for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect.

Certificate of Compliance  

Product: International Carbide Technologies ‐ Joint Systems SPEC ID 43422  INSS1186 Elastomeric FireCaulk is a water based acrylic elastomeric resin material for use on joint systems or firestops. It can be applied by brush, caulking gun, trowel, or airless sprayer. The FireCaulk is available in 310 mL tubes, 1‐gallon pails, and 5‐gallon pails. 

Certification body: Intertek Testing Services NA, Inc.Initial registration: March 1, 2018 Date of expiry: March 1, 2023 Issue status: 1 

You have been awarded:  

Intertek ETL Mark for Expansion/Seismic Joints  CAN / ULC S115 (2011), ASTM E2307 (2015), ASTM E1966 (2015)  

Certificate number: WHI18 – 23359101 

Organization: International Carbide Technology Co., Ltd. No. 250, SEC., 2, Youguan Road, Lu‐Chu District Taoyuan, 33851 Taiwan 

This is a certificate of compliance to certify that the bearer has successfully completed the requirements of the above scheme which include the testing of products, the initial assessment, and are subject to continuing annual assessments of their compliance and testing of samples of products taken from production (as applicable to the scheme) and has been registered within the scheme for the products detailed. 

Charles Meyers Certification Coordination Manager   03/01/2018 

Name  Signature Date Registered address: Intertek Testing Services NA, Inc. 545 E. Algonquin Rd. Arlington Heights, IL 60005 USA 

Report prepared for: Spec Direct (Free User) on 3/5/2018 1:57:41 PM

International Carbide Technology Co., Ltd. | 43422 | Rev: Mar 1 2018 11:33AM | Uncontrolled Copy Page 5 of 18

Page 25: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

Item1

Item

1

Item

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

ProductFM3971 INCA DC6150 Cable Coating

Firestop Design 671 (1) INCA Firestop Sheet FP-04 or INCA Firestop Sheet FP-04 +(2) INCA Fire Barrier Silicone Sealant INSS2460

Firestop Design 672 (1) INCA Firestop Sheet FP-04 or INCA Firestop Sheet FP-04 +(2) INCA Fire Barrier Silicone Sealant INSS246

Firestop Design 627

(1)INCA Firestop Sheet FP-04(2)INCA Fire Barrier Silicone Sealant INSS2460(3)INCA Firestop Sheet FP-04+(4)INCA Firestop Putty FM011(5)INCA Firestop Collar SSCI-X

Firestop Design 628 (1) ICNA FireBarrier Foam US150

FM3973 INCA ProWrap Blanketfor Grouped Electrical Cables

FM Design No. Product

Firestop Design 624(1)INCA Firestop Sheet FP-04(2)INCA Fire Barrier Silicone Sealant INSS2460(3)INCA Firestop Sheet FP-04+

Firestop Design 625(1)INCA Firestop Sheet FP-04(2)INCA Fire Barrier Silicone Sealant INSS2460(3)INCA Firestop Sheet FP-04+

Firestop Design 626(1)INCA Firestop Sheet FP-04(2)INCA Fire Barrier Silicone Sealant INSS2460(3)INCA Firestop Sheet FP-04+

Firestop Design 621

(1)INCA Firestop Sheet FP-04(2)INCA Fire Barrier Silicone Sealant INSS2460(3)INCA Firestop Sheet FP-04+(4)INCA Firestop Putty FM011

Firestop Design 622

(1)INCA Firestop Sheet FP-04(2)INCA Fire Barrier Silicone Sealant INSS2460(3)INCA Firestop Sheet FP-04+(4)INCA Firestop Putty FM011

Firestop Design 623(1)INCA Fire Barrier Silicone Sealant INSS2460(2) FP-03 INCAWOOL Board(3) DC309 Coating

Firestop Design 618(1)INCA Firestop Sheet FP-04(2)INCA Fire Barrier Silicone Sealant INSS2460(3)INCA Firestop Sheet FP-04+

Firestop Design 619 (1)INCA Fire Barrier Silicone Sealant INSS2460(2)INCA Firestop Collar SSCI-X

Firestop Design 620(1)INCA Firestop Sheet FP-04(2)INCA Fire Barrier Silicone Sealant INSS2460(3)INCA Firestop Sheet FP-04+

List of FM Report

Firestop Design 616(1) FP-03 INCAWOOL Board(2) INCA Fire Barrier Silicone Sealant INSS2460(3) DC 309 Coating

Firestop Design 617 (1) INCA Fire Barrier Silicone Sealant INSS2460

FM Approval Class No. Product

FM Approval Class No.

P 1 of 2

Page 26: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

List of FM Report

Item

16

17

18192021

22

23

24

Last Updated on 2015/3/16

FM Design No. Product

Firestop Design 682 - Configuration C (1) INCA Firestop Putty FM012Firestop Design 682 - Configuration D (1) INCA Firestop Putty FM012

Firestop Design 683

(1) INCA Firestop Putty FM011(2) INCA FP-02 Firestop Sheet(3) INCA Firestop Collar SSCI-2(4) INCA Fire Barrier Caulk INSS1440

Firestop Design 682 - Configuration E (1) INCA Firestop Putty FM012(2) INCA Firestop Putty FM011

Firestop Design 682 - Configuration F (1) INCA Firestop Putty FM012

Firestop Design 681(1)INCA Fire Barrier Caulk INSS1440(2)INCA FP 05 Coated Firestop Board(3)INCA GC99-20 Coating

Firestop Design 682 - Configuration A (1) INCA Firestop Putty FM012Firestop Design 682 - Configuration B (1) INCA Firestop Putty FM012

Firestop Design 673

(1)INCA Firestop Sheet FP-04 orINCA Firestop Sheet FP-04+(2)INCA Fire Barrier Silicone Sealant INSS2460(3)INCA Firestop Putty FM011(4)INCA Firestop Collar SSCI-X

P 2 of 2

Page 27: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

July 15th, 2015

LEED® information Concerning Firestop System Products

This information describes the contribution of Firestop System materials to LEED® Green Building Rating System according with LEED® NC v2.2.

MR Credit 2.1: Construction Waste Management, Divert 50% from Disposal The following Firestop System materials are recyclable and can contributed complying with Materials and Resources Credit 2.1.

cardboard 320g/cartoncardboard 540g/cartonHDPE 50g/tubeHDPE 740g/pailMetal 1050g/bucket

Carton of sealant Carton of putty 310ml Sealant tube 20Kgs Plastic pail 20Kgs Metal bucket 6Kgs Metal bucket Metal 460g/bucket

MR Credit 5.1: Regional Materials, 10% Extracted, Processed & Manufactured Regionally MR Credit 5.2: Regional Materials, 20% Extracted, Processed & Manufactured Regionally The Firestop System materials have been extracted, harvested or recovered, as well as manufactured, within 500 miles of the project site for minimum of 20% (based on cost) of the total materials value. The materials can contribute to comply with Materials and Resources Credit 5.1 and Credit 5.2.

US110 and US150 Fire Barrier Foam is a two component sytem manufactured on site by the applicator

EQ Credit 4.1: Low Emitting Materials, Adhesives and Sealants The following listed VOC of Firestop System materials are lower than LEED® requirements.

VOC Limited VOC (g/l) 250 53.20 250 28.60 250 16.10 250 11.50 250 22.80 250 0.00

Product Code of Firestop System INSS2460 Silicone Fire Barrier Sealant INSS1440 Fire Barrier Caulk FM011 Moldable Firestop Putty FM012 Firestop Putty US110 Fire Barrier FoamUS150 Fire Barrier Foam

Please contact IFTI for any questions.

International Fireproof Technology, Inc. 17528 Von Karman Ave. Irvine, CA 92614 [email protected]

International Fireproof Technology Inc.The Ultimate in Firestop Solutions and Fire Protective Coatings

www.painttoprotect.com

949-975-8588

Page 28: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

System No. C-AJ-1619 Ratings F Rating 2 Hr, T Rating 0 Hr, MAX Opening: 256 in2(1652 cm2) with max dimension of 16 in. (406 mm). Penetrants: Steel Pipe 6 in. (152 mm) diam (or smaller) Iron Pipe 6 in. (152 mm) diam (or smaller), Conduit 6 in. (152 mm) diam (or smaller), IFTI Products Used: Firestop Putty FM012 System No. C-AJ-2653 Ratings F Rating 3 Hr, T Rating 3 Hr, MAX Opening: 2 in. (51 mm). Penetrants: Polyvinyl Chloride (PVC) Pipe 1 in. (25 mm) diam (or smaller) , Chlorinated Polyvinyl Chloride (CPVC) Pipe 1 in. (25 mm) diam (or smaller), Rigid Nonmetallic Conduit (RNC)+ 1 in. (25 mm) diam (or smaller), IFTI Products Used: Firestop Putty FM012, Moldable Firestop Putty FM011 System No. C-AJ-2654 Ratings F Rating 2 Hr, T Rating 2 Hr, MAX Opening: 2 in. (51 mm). Penetrants: Polyvinyl Chloride (PVC) Pipe 1 in. (25 mm) diam (or smaller) , Chlorinated Polyvinyl Chloride (CPVC) Pipe 1 in. (25 mm) diam (or smaller), Rigid Nonmetallic Conduit (RNC)+ 1 in. (25 mm) diam (or smaller), IFTI Products Used: Firestop Putty FM012, Moldable Firestop Putty FM011 System No. C-AJ-4095 Ratings F Rating 2 Hr, T Rating 2 Hr, MAX Opening: 161 in2. (0.104 m2) with max dimensions of 23 in. (584 mm). Penetrants: Cable Tray Max 20 in. wide (508 mm) by max 3-1/2 in. (89 mm), Cables Max 2/C No. 14 AWG copper conductor cables with polyvinyl chloride (PVC) jacket, IFTI Products Used: Moldable Firestop Putty FM011, Firestop Putty FM012 System No. C-AJ-5355 Ratings F Rating 2 Hr, T Rating - 0 Hr, MAX Opening 48 in2. (0.031m2) with max dimension of 8 in. (203 mm). Penetrants: Busway+ 4-1/2 in. (114 mm) thickness of min 4 pcf (64 kg/m3) IFTI Products Used: Firestop Putty FM012 System No. C-AJ-6043 Ratings F Rating 2 Hr, T Rating - 0 Hr, MAX Opening 48 in2. (0.031m2) with max dimension of 8 in. (203 mm). Penetrants: Busway+ 6 in. (152 mm) by 4 in. (102 mm) IFTI Products Used: Firestop Putty FM012 System No. C-AJ-7146 Ratings F Rating 2 Hr, T Rating - 0 Hr, MAX Opening 140 in2. (0.090 m2) with max dimension of 14 in. (356 mm). Penetrants: Steel Duct 12 in. (305 mm) by 8 in. (203 mm) IFTI Products Used: Firestop Putty FM012 System No. C-AJ-7147 Ratings F Rating 2 Hr, T Rating - 0 Hr, MAX Opening 360 in2. (0.232 m2) with max dimension of 30 in. (762 mm). (356 mm). Penetrants: Steel Duct 28 in. (711 mm) by 10 in. (254 mm) IFTI Products Used: Firestop Putty FM012 System No. C-AJ-8213 Configuration A Ratings F Rating 2 Hr, T Rating 0 - MAX Opening: 896 in2. (0.578 m2)Pipe Covering with max dimension of 32 in. (813 mm) Penetrants: Steel Pipe 6 in. (152 mm) diam (or smaller) Iron Pipe 6 in. (152 mm) diam (or smaller) Conduit 6 in. (152 mm) diam (or smaller), Configuration B Ratings F Rating 2 Hr, T Rating 2 - Penetrants: Steel Pipe 3 in. (76 mm) diam (or smaller) Iron Pipe 6 in. (152 mm) diam (or smaller) Pipe Covering 1 in (25 mm) thick hollow cylindrical heavy density (min 7 pcf or 112 , T Rating is 0 Hr when pipe covering is not used, Configuration C Ratings F Rating 2 Hr, T Rating 0 - Penetrants: Busway+ 6 in. (152 mm) by 4 in. (102 mm), Configuration D Ratings F Rating 2 Hr, T Rating 0 - Penetrants: Steel Duct 12 in. (305 mm) by 8 in. (203 mm) Configuration E Ratings F Rating 2 Hr, T Rating 2 - Penetrants: Cable Tray 20 in. wide (508 mm) by max 3-1/2 in. (89 mm) Cables 2/C No. 14 AWG copper conductor cables with polyvinyl chloride (PVC) jacket and insulation to be installed within the cable tray, Configuration F F Rating 2 Hr, T Rating 0 - Penetrants: Steel Duct 12 in. (305 mm) by 8 in. (203 mm), Configuration E Ratings F Rating 2 Hr, T Rating 0-2 - Penetrants: Steel Duct 28 in. (711 mm) by 10 in. (254 mm) No. 18 (1.2 mm) Duct Insulation 1-1/2 in. (38 mm) If the duct insulation is omitted, the T Rating is 0 Hr. IFTI Products Used: Firestop Putty FM012 System No. C-BJ-2042 Ratings F Rating 2 Hr, T Rating 2 Hr, MAX Opening: 2 in. (52 mm), Penetrants: Polyvinyl Chloride (PVC) Pipe 1 in. (25 mm) diam (or smaller) Chlorinated Polyvinyl Chloride (CPVC) Pipe 1 in. (25 mm) diam (or smaller), Rigid Nonmetallic Conduit+ 1 in. (25 mm) diam (or smaller), IFTI Products Used: Moldable Firestop Putty FM011,Firestop Putty FM012 System No. C-BJ-2043 Ratings F Rating 2 Hr, T Rating 2 Hr, MAX Opening: 6 in. (152 mm), Penetrants: Polyvinyl Chloride (PVC) Pipe 4 in. (102 mm) diam (or smaller) Chlorinated Polyvinyl Chloride (CPVC) Pipe 4 in. (102 mm) diam (or smaller), Rigid Nonmetallic Conduit+ 4 in. (102 mm) diam (or smaller), IFTI Products Used: Intumescent Strip INFS0812, Firestop Putty FM012 System No. C-BJ-4036 Ratings F Rating 3 Hr, T Rating 3 Hr, MAX Opening: 624 in2 (4026 cm2) with max dimension of 48 in. (1219 mm), Penetrants: Cable Tray Max one 47-1/2 in. (1207 mm) wide by max 12 in. (305 mm) deep open ladder cable tray Cables max 4 percent of the cross-sectional area of the cable tray based on a max 1 in. (25 mm) , IFTI Products Used: Firestop Putty FM012, Firestop Sheet FP-04+

International Fireproof Technology Inc. UL Systems Firestop Putty FM012 Click on System No. in Red to see Full System

Page 29: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

System No. C-BJ-8023 Ratings F Rating 3 Hr, T Rating 1/4, 1/2, 1-1/2 and 2 Hrr, MAX Opening: 1600 in2 (10322 cm2) with max dimension of 40 in. (1016 mm), Penetrants: Cable Tray — Max one 24 in. (610 mm) wide by max 12 in. (305 mm), Cables — Aggregate cross-sectional area of cables in cable tray to be max 11 percent of the cross-sectional area of the cable tray based on a max 1 in. (25 mm).Metallic Pipe — Max two metallic pipes or conduits to be installed within opening, Steel Pipe — Nom 6 in. (152 mm) diam (or smaller), Iron Pipe — Nom 6 in. (152 mm) diam (or smaller) Conduit — Nom 4 in. (102 mm) diam (or smaller), Steel Duct — Max one 24 by 12 in. (610 by 305 mm or smaller) IFTI Products Used: Firestop Putty FM011, Firestop Sheet FP-04+, Fire Barrier Silicone Sealant INSS2460 System No. F-B-4005 Ratings F Rating 2 Hr, T Rating 0 Hr, MAX Opening :144 in2 with max dimension of 12 in. Penetrants: Cable Tray — 8 in. (203 mm) wide by max 4-1/2 in. (114 mm) deep open ladder cable tray, Cables — Aggregate cross-sectional area of cables in cable tray to be to max 5 percent of the cross-sectional area of the cable tray based on a max 4 in. cable loading depth within the cable tray., IFTI Products Used: Intumescent Strip INFS 0812, Firestop Sheet FP-02, Moldable Firestop Putty FM011, Firestop Putty FM012 System No. F-B-7004 Ratings F Rating 2 Hr, T Rating 0 Hr, MAX Opening :248 in2 with max dimension of 15-3/4 in. Penetrants: Steel Duct — Max 7-7/8 by 7-7/8 in. by No. 20 gauge (or heavier) galv steel duct, IFTI Products Used: Firestop Putty FM012

Page 30: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived
Page 31: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

International Fireproof Techology Inc. 17528 Von Karman Ave. Irvine, CA 92614 Office: 949-975-8588

Project name Project location Date Costco Canada, Various Locations Canada 2015

Boise Cascade USA Still processing Texas A&M USA 2014 Green Bay Packers Lambeau Field USA 2014-2015 Dallas Cowboy's Stadium USA 2014 Trump Towers USA 2014 Trump Towers USA 2015 Harvard University USA 2014-2015 Brown University USA 2014-2015 Southern Florida University USA 2014 Marquette University USA 2014-2015 Harvard University USA 2014-2015 Brown University USA 2014-2015 Southern Florida University USA 2014 Marquette University USA 2014-2015 Ford Motor Company USA 2015 Auburn USA 2014 Shanghai high-speed railway dispatch center China N/A China Telecom (Shanghai) Information Park China 2013 Chiquita Costa Rica 2013 MacDonald's Potatoes Storage Buildings International 2013-2015 Costco Korea 2015 Mariveles Thermo-Power Plant in Philippines Philippine 2013 Taipei 101 Taiwan 2007~2010 Nangang Station - Three co-constructed railways Taiwan 2013 National Defense Building Taiwan Still processing China Steel

Taiwan 2010 Phase II Expansion Project Winbond Electronics Taiwan 2010 Hsin-Chu Factory of Taiwan Wyeth Taiwan 2010 Yang-mei Factory of HannStar Display Taiwan 2010 Yunlin General Hospital, Department of Health of The Executive

Taiwan 2010

Ⅲ,Ⅳ,Ⅴ Factory of TSMC Taiwan 2014 Electric Room in Chinese Petroleum Corporation (CPC) Taiwan 2014 Miao-Li General Hospital, Department of Health of The Executive

Taiwan 2010

Ban-Qiao Office of Chungwha Telecom (CHT) Taiwan 2011 Asia Union Electronic Chemical Corporation (AUECC) Taiwan 2011 New Century InfoComm Tech. Co., Ltd. Taiwan 2011

Page 32: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

Electronic Mill of FarEasTone Taiwan 2008 Gas Mill of TSMC Taiwan Still processing Ⅷ Factory of TSMC Taiwan Still processing Communication Center of Taiwan University Taiwan 2012 Cathay Xin-Yi Trading Center Taiwan 2010 National Army Senior High School Taiwan 2007 Kuang-Fu High School Taiwan 2004 The Judicial Yuan of R.O.C. Taiwan 2004 Electronic Mill of chungwha Telecom (CHT) Taiwan 2009 Nan KaiCollege Taiwan 2004 Phihong Technology Co.,Lltd. Taiwan 2006 Standard Factory in Hsin-Chu Science Park Taiwan 2011 ACL/RCM Electronic Mill of China Steel Corporation (CSC) Taiwan 2011 Main Substation of China Steel corporation (CSC) Taiwan 2008 Electronic Mill of Yieh-Lung Enterprise Co., Ltd. Taiwan 2008 National Kaohsiung First University of Science and Technology Taiwan 2008 Tong-Xiao Power Plant, TPC Taiwan 2008 Police office Wenshan branch Taiwan 2010 Taipei MRT Mucha line extension Taiwan 2006 MRT Luzhou Line Taiwan 2006 Sharon substation Taiwan 2006 Kaohsiung MRT Taiwan 2006 Concord power plant Taiwan 2010 Donggang Post Office Taiwan 2010 Nen ke Elementary School Taiwan 2010 Gigabyte Technology Taiwan 2010 LU YUAN D/S Substation Taiwan 2010 MRT Kaohsiung Line Taiwan 2006 MRT Luzhou Line (New Taipei city) Taiwan 2006 MRT Mucha line (New Taipei city) Taiwan 2006 Taiwan High Speed Rail Taiwan 2010 Hsinchu train Station Taiwan 2007 MRT Xinyi (Taipei) Taiwan Processing MRT Neihu (Taipei) Taiwan 2014 MRT Xinzhuang (New Taipei city) Taiwan 2009 Nangang Station - Three co-constructed railways Taiwan 2013 MRT Airport line Taiwan 2010 MRT Taoyuan (Taoyuan city) Taiwan 2011 MRT Songshan (Taipei) Taiwan 2012 Seagate hard drive factory Thailand 2015 Amari Bangkok Watergate hotel Thailand 2015 Amari Bangkok DMK Thailand 2015 Betagen yogurt factory Thailand 2015 Plastic Tech Plastic injection plant Thailand 2015

Formosa Vietnam ha tihn steel Vietnam Still

China Steel Sumikin Vietnam JSC Vietnam Still

Page 33: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

SDS for INSS1440

1

Safety Data Sheet – FM012

1. Product and Company IdentificationProduct: Firestop Putty Product Code: FM012 Company: International Fireproof Technology, Inc.

17528 Von Karman Ave. Irvine, CA 92614 Office: 949-975-8588Emergency Telephone Number: CHEMTREC 1-800-424-9300

2. Hazards Identification

Hazard classification: Acute toxicity (Oral) Cat.4, Skin irritation Cat.3, Eye irritation Cat. 2B, Carcinogenicity Cat. 2B

Pictogram:

Signal Words: Warning

Hazard statement: May be harmful if swallowed Causes mild skin irritation Cause eye irritation

Suspect of causing cancer

Precautionary statement: Prevention: Obtain special instructions before use. Do not handle until all safety

precautions have been read and understood. Use personal protective equipment as required. Wear eye or face protection. Do not breathe vapor. Wash hands thoroughly after handling.

Response: Get medical attention if you feel unwell. IF exposed or concerned: Get medical attention. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical attention.

Storage: Store locked up. Disposal: Dispose of contents and container in accordance with all local,

regional, national and international regulations. Supplemental label elements :

WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. FOR INDUSTRIAL USE ONLY.

International Fireproof Technology Inc.The Ultimate in Firestop Solutions and Fire Protective Coatings

www.painttoprotect.com

949-975-8588

Page 34: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

SDS for INSS1440

2

Hazards not otherwise classified:None known.

3. Composition/Information on Ingredients

Ingredient CAS No Percent Aluminum hydroxide 21645-51-2 5~15% Pentaerythritol 115-77-5 1~10% Red phosphorous 7723-14-0 1~3% Titanium dioxide 13463-67-7 1~2% Iron oxide 1309-37-1 1~2%

4. First Aid Measures

Inhalation : Remove victim to fresh air and keep at rest in a position comfortable for breathing. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband. In case of inhalation of decomposition products in a fire, symptoms may be delayed. The exposed person may need to be kept under medical surveillance for 48 hours.

Ingestion : Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Skin Contact :

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Continue to rinse for at least 10 minutes. Get medical attention. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Eye Contact :

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention

Page 35: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

SDS for INSS1440

3

Potential acute health effects:

Inhalation: Exposure to decomposition products may cause a health hazard. Serious effects may be delayed following exposure

Ingestion: May be irritating to mouth, throat and stomach. Skin contact: No known significant effects or critical hazards. Eye contact: Causes eye irritation.

5. Fire Fighting Measures Suitable extinguishing media :

Use an extinguishing agent suitable for the surrounding fire.

Specific hazards arising from the chemical :

In a fire or if heated, a pressure increase will occur and the container may burst.

Hazardous thermal decomposition products:

Decomposition products may include the following materials: carbon dioxide carbon monoxide nitrogen oxides metal oxide/oxides

Special protective actions for fire-fighters:

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Special protective equipment for fire-fighters:

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.

6. Accidental Release Measures

Personal precautions, protective equipment and emergency procedures For non-emergency Personnel:

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Avoid breathing vapor or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.

For emergency If specialized clothing is required to deal with the spillage,

Page 36: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

SDS for INSS1440

4

responders : take note of any information in Section 8 on suitable and unsuitable materials. See also the information in "For nonemergency personnel".

Environmental precautions:

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air).

Methods and materials for containment and cleaning up

Small spill: Stop leak if without risk. Move containers from spill area.

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill: Stop leak if without risk. Move containers from spill area. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product. Note: see Section 1 for emergency contact information and Section 13 for waste disposal.

7. Handling and Storage

Handling: 1. Container must be labeled, close containers when not in use. 2. Ventilate designated places, to avoid the release of vapor or

mist when using. 3. Suitable fire extinguisher and spill kit shall be kept readily

available to deal with fire and emergency response to device leakage.

Storage: Comply with the storage and handling of flammable or combustible materials regulations. Store in cool and dry area, away from heat, sparks and freezing temperatures. Use up as soon as possible after opening the lid; Ideal storage temperature is 5 ℃ ~ 35 ℃

Page 37: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

SDS for INSS1440

5

8. Exposure Controls/Personal Protection

Ingredient Regulatory Code Classification

Titanium Dioxide ACGIH TLV (United States, 4/2014) TWA: 10 mg/m³ 8 hours.

OSHA PEL (United States, 2/2013)

TWA: 15 mg/m³ 8 hours. Form: Total dust

Pentaerythritol NIOSH REL (United States, 10/2013)

TWA: 5 mg/m³ 10 hours. Form: Respirable fraction TWA: 10 mg/m³ 10 hours. Form: Total

ACGIH TLV (United States, 4/2014) T TWA: 10 mg/m³ 8 hours.

OSHA PEL (United States, 2/2013)

TWA: 5 mg/m³ 8 hours. Form: Respirable Fraction TWA: 15 mg/m³ 8 hours. Form: Total dust

Appropriate engineering controls:

If user operations generate dust, fumes, gas, vapor or mist, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits.

Environmental exposure controls:

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Individual protection measures

Hygiene measures:

Wash hands, forearms and face thoroughly after handling chemical products, before eating, smoking and using the lavatory and at the end of the working period. Appropriate techniques should be used to remove potentially contaminated clothing. Wash contaminated clothing before reusing. Ensure that eyewash stations and safety showers are close to the workstation location.

Eye/face protection

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: chemical splash goggles.

Skin protection

Page 38: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

SDS for INSS1440

6

Hand protection: Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated.

Body protection: Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Other skin protection:

Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Respiratory protection:

Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.

9. Physical and Chemical Properties

Appearance : Red paste Odor : Light emulsion odor pH : 7.0±1.0 Density (25℃): 1.40±0.05 g/cm3

Viscosity (at 25℃): >100000 cps

Volatile: 20 ~ 30﹪ Solubility : Water miscible Partition coefficient: n-octanol / water N/A

Flash point : >100℃

Boiling point/boiling range : >100℃ Melting point/range : N/A Evaporation rate : N/A Vapor pressure : N/A Relative vapor density : N/A Auto-ignition temperature : N/A Flammability (solid, gas) : Non-flammable Lower explosion limit : N/A Upper explosion limit : N/A Self-ignition temperature : N/A Decomposition temperature N/A

10. Stability and Reactivity

Stability: Stable under ordinary conditions of use and storage.

Special Condition of Hazardous Reaction:

N/A

Incompatibilities: Organic solvent Materials to Avoid: Strong acid or alkali and oxidant

Page 39: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

SDS for INSS1440

7

Hazardous decomposition products: Will emit smoke, CO, CO2 when burned

11. Toxicological Information

Acute toxicity Product/ingredient name Result Species Dose Exposure

Pentaerythritol LD50 Oral Rat 18500 mg/kg --- Irritation/Corrosion Product/ingredient

name Result Species Score Exposure Observation

Pentaerythritol Skin : Mild irritant

Human --- 72 hours 300 Micrograms Intermittent

---

Classification

Product/ingredient name OSHA IARC NTP Pentaerythritol --- 2B ---

Specific target organ toxicity (single exposure) Product/ingredient name Category Route of exposure Target organs

Pentaerythritol Category 3 Not applicable Respiratory tract irritation and Narcotic effects

Specific target organ toxicity (repeated exposure) Product/ingredient name Category Route of exposure Target organs

Pentaerythritol Category 3 Not applicable Respiratory tract irritation and Narcotic effects

12. Ecological Information

Toxicity Product/ingredient name Result Species Exposure

Pentaerythritol Acute LC50 >1000000 μg/l Marine water

Fish – Fundulus heteroclitus

96 hours

Page 40: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

SDS for INSS1440

8

Bioaccumulative potential Product/ingredient name LogPow BCF Potential

Titanium Dioxide --- 352 low Pentaerythritol --- 1.26 low

13. Disposal Considerations Disposal methods: The generation of waste should be avoided or minimized wherever

possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction. Waste packaging should be recycled. Incineration or landfill should only be considered when recycling is not feasible. This material and its container must be disposed of in a safe way. Care should be taken when handling emptied containers that have not been cleaned or rinsed out. Empty containers or liners may retain some product residues. Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

14. Transport Information

DOT Classification

TDG Classification

Mexico Classification

IATA IMDG

UN number Not regulated Not regulated Not regulated Not regulated Not regulated UN proper

shipping name

Transport hazard class(es)

Packing group Environmental

hazards No No No No No

Additional information

Special provisions

Not Applicable

Special provisions

Not Applicable

Special provisions

Not Applicable

Special provisions

Not Applicable

Special provisions

Not Applicable Special precautions for user:

Multi-modal shipping descriptions are provided for informational purposes and do not consider container sizes. The presence of a shipping description for a particular mode of transport (sea, air, etc.), does not indicate that the product is packaged suitably for that mode of transport. All packaging must be reviewed for suitability prior to shipment, and compliance with the applicable regulations is the sole responsibility of the person offering the product for transport. People loading and unloading dangerous goods must be trained on all of the risks deriving from the substances and on all actions in case of emergency situations.

Page 41: IFTI Firestop Submittal · Below is a list of Model Building Codes requiring the use of firestop products in various types of constructions and occupancies. Most local codes are derived

SDS for INSS1440

9

15. Regulatory Information

Ingredient CAS No Regulatory Code Classification Aluminum hydroxide 21645-51-2 WHMHAZ WHMIS - Canada

Hazardous Chemicals Titanium Dioxide 13463-67-7 CAPROP CA Prop 65

IARG2B IARC - Group 2B - Possibly Carcinogenic to Humans

WHMHAZ WHMIS - Canada Hazardous Chemicals

WMPR List of WM Priority Chemicals Feb 2014

Pentaerythritol 115-77-5 WHMHAZ WHMIS - Canada Hazardous Chemicals

Iron oxide 1309-37-1 WHMHAZ WHMIS - Canada Hazardous Chemicals

Red phosphorus 7723-14-0 CAWAST California Hazardous Waste

S313T SARA313-Emissions Reporting

SAREHS CERCLA/SARA Extremely Hazardous Substances

WHMHAZ WHMIS - Canada Hazardous Chemicals

WMPR List of WM Priority Chemicals Feb 2014

16. Other Information

This information is based on our present state of knowledge. It should not therefore be construed as guaranteeing specific properties of the products described or their suitability for a particular application.

Revision Information: 8/12/2015 Prepared by: International Fireproof Technology Inc. Phone Number: 949-975-8588