imaging object change management (iocm) kinson ho – architect, agfa healthcare
TRANSCRIPT
• Imaging Object Change Management (IOCM)
Kinson Ho – Architect, Agfa HealthCare
Problem Statement
• Patient movement during acquisition• Forgot about system default (e.g. LCC vs RCC)• Human error (e.g. select wrong worklist item)
imagesstored
patientinformation
RIS
examination orders
imagesretrievedimages
retrieved
HIS
PACS
procedurescheduled
Prefetch any relevantprior studies
procedurescheduled
Prefetch any relevantprior studies
modalityworklist
report
report
report
report
RegistrationRegistration
Orders PlacedOrders Placed
Orders FilledOrders Filled
FilmFilm
FilmFolderFilm
FolderImage Manager
& ArchiveImage Manager
& Archive
FilmLightbox
FilmLightbox
reportreport ReportRepository
ReportRepository
DiagnosticWorkstationDiagnostic
Workstation
ModalityModality
acquisitionacquisitioninin--progressprogressacquisitionacquisitioninin--progressprogressacquisitioncompletedacquisitioncompleted
acquisitioncompletedacquisitioncompleted
imagesprintedimagesprinted
AcquisitionModality
AcquisitionModality
Problem Statement
• Bad situations become worse
HospitalHospital
Imaging CenterImaging CenterPhysician PracticePhysician Practice
Between Radiology and :Between Radiology and :•• IImaging specialistsmaging specialists•• NonNon--imaging cliniciansimaging clinicians PACS Y
PACS Z
Radiology Radiology --toto--RadiologyRadiology
Radiology Radiology --toto--PhysiciansPhysicians
Value Proposition• When people make mistakes, patient safety is potentially
compromised• In a distributed system, correction has to be propagated accordingly
for proper timely and accurate patient care
Imaging Object Change Management profile provides
A change management communication protocolthat has well-defined scope,
is simple to understandand least disruption
Use Cases
• Use Cases
Quality Reason (e.g. Patient Movement)
Patient Safety Reason (e.g. Incorrect View Code)
Incorrect Worklist Selection
Data Retention Expiration• Continue to rely on existing mechanisms for other changes
Scheduled Workflow
Patient Information Reconciliation
Import Reconciliation Workflow
Design Principles (1)
• Reject and Replace• Improvement with least disruption
Smart Source
Regular Image Manager + Regular Display
Smart Image Manager + Regular Display
Regular Image Manager + Smart Display• Compatible with portable media and external publication
Design Principles (2)
• Use standard DICOM Key Object Selection Document
Reuse DICOM Storage, Query/Retrieve services• A unique Key Object Document Title for each use case
(113001, DCM, “Rejected for Quality Reasons”)
(113037, DCM, “Rejected for Patient Safety Reasons”)
(113038, DCM, “Incorrect Modality Worklist Entry”)
(113039, DCM, “Data Retention Policy Expired”)
High Level Data Flow (1)
High Level Data Flow (2)
Actor / Transaction Diagram (1)
• Core actors related to Scheduled Workflow (SWF) and Import Reconciliation Workflow (IRWF)
ChangeRequester
ImageManager
ImageArchive
Importer
DSS / OFImageDisplay
Instance AvailabilityNotification
Rejection Note Stored Replacement Instances Stored
Query Images Retrieve Images Query Key Image Notes Retrieve Key Image Notes
Imported Objects Stored
ChangeRequester
ImageManager
ImageArchive
Importer
DSS / OFImageDisplay
Instance AvailabilityNotification
Rejection Note Stored Replacement Instances Stored
Query Images Retrieve Images Query Key Image Notes Retrieve Key Image Notes
Imported Objects Stored
Actor / Transaction Diagram (2)
• Actors related to Portable Data for Imaging (PDI)
ReportReader
Display
ImageDisplay
PortableMedia
Importer
PortableMedia
Creator
PrintComposer
Distribut ImagingInformation On Media
Distribut ImagingInformation On Media
Distribut ImagingInformation On Media
Distribut ImagingInformation On Media
Distribut ImagingInformation On Media
ReportReader
Display
ImageDisplay
PortableMedia
Importer
PortableMedia
Creator
PrintComposer
Distribut ImagingInformation On Media
Distribut ImagingInformation On Media
Distribut ImagingInformation On Media
Distribut ImagingInformation On Media
Distribut ImagingInformation On Media
Actor / Transaction Diagram (3)
• Actors related to Cross Enterprise Document Sharing for Imaging (XDS-I)
DocumentRepository
ImagingDocumentConsumer
ImagingDocument
Source
WADO Retrieve Retrieve Imaging Document Set
Provide and Register Imaging Document Set – MTOM/XOP
Retrieve Images Retrieve Presentation States Retrieve Reports Retrieve Key Image Notes Retrieve Evidence Documents
DocumentRepository
ImagingDocumentConsumer
ImagingDocument
Source
WADO Retrieve Retrieve Imaging Document Set
Provide and Register Imaging Document Set – MTOM/XOP
Retrieve Images Retrieve Presentation States Retrieve Reports Retrieve Key Image Notes Retrieve Evidence Documents
Key Requirements• 5 classes of Actors
– Change Requester– Image Manager– Importer / Exporter*– Change Consumer*– Department Scheduler System / Order Filler
* Not actual actor name
Key Requirements – Change Requester• Required to group with
– Modality– Evidence Creator– Image Manager
• Create Rejection Note• Create Replacement Instances
– Metadata must be corrected• Match correct worklist• Match critical attributes
Key Requirements – Image Manager• Process Rejection Notes : Quality Reason
– Configurable Behavior• Regular Use• Hide Rejected Instances in Query/Retrieve
– Provide 2 AE Titles for each C-Find and C-Move– Configurable to restrict access to “Regular Use” AE
Key Requirements – Image Manager• Process Rejection Notes : Patient Safety or MWL Correction
– Not provide this Rejection Note in Query/Retrieve/Store– Not provide rejected instances in Query/Retrieve/Store– Not accept subsequent occurrence of rejected instances
• Process Rejection Notes : Data Retention Policy Expired– Delete the expired instances– Delete this Rejection Note– Accept subsequent occurrence of deleted instances
Key Requirements – Image Manager• Receive replacement instances• Send Instance Availability Notification to DSS/OF
– Include all available• Status: ONLINE, NEARLINE or OFFLINE
– Include rejected instances• Status: UNAVAILABLE
– Special case for Rejection of Quality Reason• Hide rejected instances• Regular Use
Key Requirements – Importer / Exporter• Includes
– Importer (IRWF)– Portable Media Creator, Portable Media Importer (PDI)– Imaging Document Source (XDS-I.b)
• Exclude Rejection Note• Exclude rejected instances
Key Requirements – Change Consumer• Includes
– Image Display (SWF or PDI)– Display, Report Reader, Print Composer (PDI)– Imaging Document Consumer (XDS-I.b)
• Rejection: Quality Reason– Configurable behaviour for showing / hiding rejected instances
and the rejection note• Rejection: Other 3 Reasons
– No Rejection Note and rejected instances
Key Requirements – DSS / OF• Receives Instance Availability Notification from Image Manager• Specially important for Worklist Correction case
– If the procedure step has no more available instances, then reset the status to Scheduled.
Next Step
• Review Trial Implementation of IOCM:
http://www.ihe.net/Technical_Framework/index.cfm#radiology
• Sign-up to participate in IHE Connectathon in early 2014