Page 1: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

CATALOGUE2019

THE GRAND MORSE

The GMImplant

A Straumann Group Brand

Page 2: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

003002

Helix GM

GREATNESS IS AN ACHIEVEMENT.

NEODENT®

GRAND MORSEIMPLANT SYSTEM

The Neodent® Grand Morse Implant System is the achievement of more than 20 years of

experience in implant dentistry, and shared experiences with many clinicians worldwide.

Continuing with a unique purpose to always deliver high quality treatment options that

changes patients’ lives, the Grand Morse Implant System is the Neodent® evolution.

Anchor within our philosophy of respecting mechanical and biological principles, this

makes it THE implant of choice in dental implant therapy.

The Grand Morse implant system was developed based on the inside out concept,

starting from the core of the implant: the prosthetic interface. The result is a solution

that combines mechanical strength and versatile prosthetic solutions - from unitary

to multiple and from conventional to digital. A complete system that offers several

benefits designed to make your work even more efficient.

+150studies

+ 20yearshistory

2nd

largest dental implantcompany worldwide

GRANDRELIABILITY

Stable and strong

foundation designed for

long term success

GRANDSIMPLICITY

Ease of use

at its best.

GRANDESTHETICS

Delivers immediate

natural esthetics.

GRANDSTABILITY

Designed for predictable

immediate treatments in all

bone types.

Page 3: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

005004

GRAND SIMPLICITY

Ease of use at its best.

ONE SCREWDRIVER ONE SURGICAL KIT ONE IMPLANT DRIVER

Implant therapy has become an integral part of clinical dentistry, with ever increasing numbers of patients seeking

such treatment. The Neodent® Grand Morse Implant System is smartly engineered providing efficiency and simplicity

within the dental treatment network for both surgical to restoratives steps.

All Neodent® Grand Morse implants feature the unique Grand Morse connection regardless of the implant diameter.

The new Neo Screwdriver has a star

attachment offering reliability and durability

compatible with all Neodent® Grand Morse

healing abutments and restorative screws.

All Neodent® Grand Morse implants

can be placed using the intuitive,

and functional surgical kit.

The new Neodent® implant

driver allows an easy and reliable

implant pick up and placement.

ONE PROSTHETIC PLATFORM 6

.6m

m

16° Morse Taper connection

Designed to ensure tight fit

for an optimal connection

sealing.

Internal Indexation

Precise abutment positioning,

protection against rotation

and easy handling.

Platform Switching

Abutment design with a narrower

diameter than the implant coronal

area, enabling the platform

switching concept.(5-9)

Deep Connection

Allowing a large contact area

between the abutment and

the implant for an optimal

load distribution.

1

2

4

1

3

3

2

4

Ø3.0mm

16º

GRAND RELIABILITY

Stable and strong designed for long term success.

The implant-abutment interface is crucial for a successful long term functional and esthetic result. The Neodent®

Grand Morse connection offers a unique combination based on proven concepts: a platform switching associated

with a deep 16° Morse Taper including an internal indexation for a strong and stable connection designed to achieve

long-lasting results.

Page 4: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

007006

GRAND ESTHETICS

Deliver immediate natural esthetics.

Nowadays, patients expect both short treatment times and esthetic results. The Neodent® Grand Morse restorative

portfolio offers flexibility to simplify soft tissue management respecting the biological distances for achieving

immediate function and esthetics.

Neodent Digital solutions offer modern and reliable treatment options for the digital workflow. Through a dedicated

digital portfolio it is possible to plan your surgical cases, perform guided surgeries and have customized prosthetic

restorations. Digital, from root to tooth:

- Intra-oral scanbodies for precise digitalization.- Sharply designed implant libraries available in the majority of surgical planning softwares.- Optimized surgical instruments and sleeves tailored to your portfolio preferences.- Titanium bases and titanium blanks for fully customized prosthetic restorations.

NEXT LEVEL OF IMMEDIATE FIXED FULL-ARCH TREATMENT

The new Neodent® Grand Morse Mini Conical abutment has been

designed to improve fixed full-arch treatment by optimizing the

abutment emergence profile reducing the need of invasive procedures.

The Neodent® Grand Morse implant system has a wide range of restorative options covering:

- All indications: single to edentulous

- All treatment protocols: immediate to delayed loading

- All workflows: conventional to digital.

PEACE OF MIND WITH THE UNLOCKING FEATURE

Neodent® has developed a unique feature allowing a simple

and reliable abutment removal for a user friendly experience.

COMPREHENSIVE PROSTHETIC PORTFOLIO FOR OPTIMIZED ESTHETIC RESULTS

Grand Morse® Abutments

Digitally friendly. From root to tooth.

Pro-PeekAbutment

Titanium Temporary Abutment

Temporary Single or

Multiple-unit

Screw-retained

prosthesisOverdenture

Screw-retainedprosthesis

Cement-retainedprosthesis

Screw or Cement-retained prosthesis

Single or Multiple-unit

Multiple-unitMultiple-unitTemporary Single-unit

Single-unit Single-unit

AbutmentTitanium

BaseTitaniumBase C

CoCr Abutment

TitaniumBlock

(AG or Medentika Holder)

(straight and angled)

(straight and angled)

(straight and angled)

Titanium Base for Bridge

AnatomicAbutment

Universal Abutment

Angled MiniConical

AbutmentNovaloc

Neo Torque Connection - 20 N.cm

Hexagonal Prosthetic Driver

32 N.cm

Single orMultiple-unit

Multiple-unitSingle-unit

Screw orCement-retained

prosthesis

ASScrewdriver

20 N.cm

Micro Abutment

Mini ConicalAbutment

TitaniumBase AS

Screw-retainedprosthesis

Intra-oralscanbody

coDiagnostiX®

or other widelyavailable softwares

NeodentGuided Surgery

CustomizedProsthetic Restorations

Please Note:Titanium Base ASAvailable from 1. Quarter 2020

Page 5: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

009008

Acqua Hydrophilic Surface designed for high treatmentpredictability

Surface comparison

The Neodent® Acqua hydrophilic surface is the next level of the highly successful S.L.A. type of surface developed to achieve successful outcomes even in challenging situations, such as soft bone or immediate protocols(1-4)

Normal surface Acqua Hydrophilic Surface

Acqua Surface interaction (electropositive) with blood electronegative).

Surfaceconcept evolution

Hydrophilicity

The hydrophilic surface presents a smaller contact angle when in contact with hydrophilic liquids. This provides greater accessibility of organic fluids to Acqua implant surface.(2)

Constant evolution and safety guarantee.

Based on the abrasive sandblasting concept followed by acid etching, the NeoPoros surface promotes, by using controlled grain oxides, cavities on the implant surface that then are uniformed with the acid etching technique.

The whole process of obtaining this surface is guaranteed due to automated time, speed, pressure and particle size control.

Several scientific studies continue to be performed so that the NeoPoros surface may be always evolving and promoting much more reliability for you.

Controlled roughness on all implant surface. Scanning electron microscopy (A) shows macro (15-30μm) and

(B) microtopography (0,3 - 1,3μm).

(A) (B)

Image taken by confocal microscopy. Roughness and Microtopography. (Sa= 1,4 – 1,8 μm; Sz= 15 μm).

Page 6: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

011010

Implants Description:

• Full dual tapered implant;

• Hybrid contour with a cylindrical coronal part and conical

on the apical area;

• Active apex including a soft rounded small tip and

helicoidal flutes;

• Dynamic progressive thread design: from compressing

trapezoidal threads on the coronal area to self-tapping

V-shape threads on the apical part;

• Double threaded implant;

• Grand Morse® connection.

Indications:

• Indicated for all types of bone density and implant

immediate placement post extraction.

Drilling features:

• Contour drill is required in bone types I and II;

• Final pilot drills are highly recommended in bone types I

and II;

• Implant should be positioned 1 or 2 mm below bone level;

• Drilling speed: 800-1200 rpm for bone type I and II;

• Drilling speed: 500-800 rpm for bone type III and IV;

• Implant insertion speed: 30 rpm;

• Maximum torque for implant placement: 60 N.cm.

PRODUCT FEATURES:

Helix GM®

Available with:

or®

8.0 mm 10.0 mm 13.0 mm11.5 mm 16.0 mm 18.0 mm

103.418 103.427103.405 103.422103.414 103.411103.420 103.416103.399 103.423103.415 103.408103.419 103.417103.402 103.421103.425103.170

140.943

109.943

140.976

109.976

140.982

109.982

140.948

109.948

140.953

140.1009

109.953

109.1009

140.944

109.944

140.977

109.977

140.983

109.983

140.949

109.949

140.954

140.1010

109.954

109.1010

140.945

109.945

140.978

109.978

140.984

109.984

140.950

109.950

140.955

140.1011

109.955

109.1011

140.946

109.946

140.979

109.979

140.985

109.985

140.951

109.951

140.956

140.1012

109.956

109.1012

140.947

109.947

140.988

109.988

140.980

109.980

140.981

109.981

140.986

109.986

140.987

109.987

140.952

109.952

140.957

109.957

140.989

109.989

140.990

109.990

Ø 3

.5Ø

3.7

4.0

Ø 4

.3Ø

5.0

Ø 6

.0

NeoPoros

NeoPoros

NeoPoros

NeoPoros

NeoPoros

NeoPoros

Acqua

Acqua

Acqua

Acqua

Acqua

Acqua

117.021 117.022

GM Cover Screw

:: Use the manual Neo Screwdriver (104.060);:: Do not exceed the insertion torque of 10 N.cm.

0 mm 2 mm

Initial Ø 5.0+Ø 4.3+Ø 4.0+Ø 3.75+Ø 3.5+ Ø 5.0Ø 4.3Ø 4.0Ø 3.75Ø 3.5Ø 2.0

Ø 3.5

Ø 3.5

Ø 3.75

Ø 3.75

Ø 4.0

Ø 4.0

Ø 4.3

Ø 4.3

Ø 5.0

Ø 5.0

Ø 4.3/5.0 Ø 6.0Ø 3.6/4.3Ø 3.3/4.0Ø 3.0/3.75Ø 2.8/3.5

Drill Sequence

Helix GM® Implants / Helix GM® Acqua Implants Bone types III and IV

Bone types I and II

Optional

Optional

Optional

Optional

Optional

Optional Optional

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Optional

Ø 6.0 Optional

106.207

106.223

106.208

106.224

106.209

106.225

106.210

106.226

106.211

106.227

106.212

106.213 106.214

106.228

106.215

106.229

106.216

106.230

106.217

106.231

106.218

106.232

Ø 3.3

Ø 5.5

Ø 4.5

Ø 7.0

5.5 mm

6.5 mm

4.5 mm

5.5 mm

3.5 mm

4.5 mm

2.5 mm

3.5 mm

1.5 mm

2.5 mm

0.8 mm

1.5 mm

:: Use the manual Neo Screwdriver (104.060);:: Do not exceed the insertion torque of 10 N.cm.

GM Healing Abutment

Profile

Profile

GM Customizable Healing Abutments

Page 7: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

013012

Available with:

Implants Description:

• Tapered implant;

• Square shape threads;

• Double threaded implant;

• Reverse cutting chambers distributed across the implant body;

• Rounded apex with a sharp edge;

• Grand Morse® connection.

Indications:

• Indicated for bone types III and IV and implant immediate

placement post-extraction;

Drilling features:

• Final pilot drill is optional in bone types III and IV;

• Implant should be positioned 1 or 2 mm below bone level;

• Drilling speed: 500-800 rpm;

• Implant insertion speed: 30 rpm;

• Maximum torque for implant placement: 60 N.cm.

PRODUCT FEATURES:

Drive GM®

®

8.0 mm 10.0 mm 13.0 mm11.5 mm 16.0 mm 18.0 mm

103.408 103.411103.399 103.418103.414 103.417103.425103.170

140.958

140.964

140.970

140.959

140.965

140.971

140.960

140.966

140.972

140.961

140.967

140.973

140.962 140.963

140.968

140.974

140.969

140.975

Ø 3

.5Ø

4.3

Ø 5

.0

Acqua

Acqua

Acqua

Initial Ø 5.0Ø 3.6/4.3Ø 3.5Ø 2.0 Ø 4.3/5.0Ø 4.3Ø 2.8/3.5

Drill Sequence

Drive GM® Acqua Implants

Bone types III and IV

Optional

Optional

Optional

Ø 3.5 mm

Ø 4.3 mm

Ø 5.0 mm

117.021 117.022

GM Cover Screw

:: Use the manual Neo Screwdriver (104.060);:: Do not exceed the insertion torque of 10 N.cm.

0 mm 2 mm106.207

106.223

106.208

106.224

106.209

106.225

106.210

106.226

106.211

106.227

106.212

106.213 106.214

106.228

106.215

106.229

106.216

106.230

106.217

106.231

106.218

106.232

Ø 3.3

Ø 5.5

Ø 4.5

Ø 7.0

5.5 mm

6.5 mm

4.5 mm

5.5 mm

3.5 mm

4.5 mm

2.5 mm

3.5 mm

1.5 mm

2.5 mm

0.8 mm

1.5 mm

:: Use the manual Neo Screwdriver (104.060);:: Do not exceed the insertion torque of 10 N.cm.

GM Healing Abutment

Profile

Profile

GM Customizable Healing Abutments

Page 8: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

015014

Unlocking feature

Ø 4.8mm

GM AbutmentRecommended in posterior area.

Exact

Single-unit screw-retainedprosthesis

Consider in addition 1.5 - 2.0 mm for the restorative material

Minimum interocclusal space of 4.9 mm from the mucosa level

108.179

118.298

101.076

118.299

115.237 115.238 115.239

115.240 115.241 115.242

5.5 mm4.5 mm3.5 mm

2.5 mm1.5 mm0.8 mm

21

11

GM Exact Abutment

GM Abutment Impression Coping

Closed Tray

106.221

2Neo Abutment Protection

Cylinder

Conventional

Neo Screwdriver Torque Connection

Neo Screwdriver Torque Connection

Torque Wrench Manual Screwdriver Torque

Neo Abutment Burn-out CopingNeo Abutment CoCr Coping

or

or

+ +

20N.cm

10N.cm

10N.cm

Installation Sequence

116.267118.300

1Neo Abutment Titanium Coping

10N.cm

116.266

Neotorque*

Titanium

116.267

116.266

Neotorque*

Titanium116.267

116.266

Neotorque*

Titanium

*Application of a film carbon-based coat that provides a lower friction coefficient, resulting in increased pre-load.

101.101 Hybrid Repositionable (conventional/digital)

2

Abutment Analog

Ø 4.8

Ø 4.8

1

Page 9: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

017016

GM Mini Conical AbutmentMultiple-unit screw-retainedprosthesis

Exact

Ø 4.8mm

Ø 4.8mm

123.008

AccessoriesMini Conical Abutment Polishing Protector

Consider in addition 1.5 - 2.0 mm for the restorative material

Minimum interocclusal space of 4.5 mm from the mucosa level for straight abutments.

115.243 115.244 115.245

115.246 115.247 115.248

5.5 mm4.5 mm3.5 mm

2.5 mm1.5 mm0.8 mm

115.249

118.301

115.250

118.303

115.251

115.252

115.267

115.253

115.268

115.254

17º

30º

45º

3.5 mm2.5 mm1.5 mm

108.176

101.020

2

1

Neo Screwdriver Torque Connection

Neo Screwdriver Torque Connection

Torque Wrench Manual Screwdriver Torque

++ +

2

3

22

GM Mini Conical Abutment

GM Exact Mini Conical Abutment 17°/30°/45°

Slim Mini Conical AbutmentOpen Tray Impression Coping

106.220

3Neo Mini Conical Abutment Protection

Cylinder

Conventional

Neo Mini Conical Abutment Burn-out Coping

Neo Mini Conical Abutment CoCr Coping

32N.cm

20N.cm

10N.cm

10N.cm

1

HexagonalProsthetic Driver

Torque Wrench

or

or

or

Installation Sequence

118.302

2Neo Mini Conical Abutment

Titanium Coping

10N.cm

116.270

116.269

Neotorque*

Titanium

116.270

116.269

Neotorque*

Titanium

116.270

116.269

Neotorque*

Titanium

*Application of a film carbon-based coat that provides a lower friction coefficient, resulting in increased pre-load.

101.092 Hybrid Repositionable (conventional/digital)

3

Mini Conical Abutment Analog

Page 10: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

019018

GM Micro AbutmentRecommended for limited spaces and narrow inter-dental spaces. Multiple-unit

screw-retainedprosthesis

Single-unit screw-retainedprosthesis

OR

Ø 3.5mm

Accessories

123.015

Micro Abutment

Polishing Protector

Bridge

Consider in addition 1.5 - 2.0 mm for the restorative material

Minimum interocclusal space of 3.5 mm from the mucosa level

118.295

118.315

118.296

118.316

BridgeBridge

CrownCrown

101.078

115.255 115.256 115.257

115.258 115.259 115.260

5.5 mm4.5 mm3.5 mm

2.5 mm1.5 mm0.8 mm

3

1

22

GM Micro Abutment

106.219

3Neo Micro Abutment Protection Cylinder

for Crown (conventional)

Neo Micro Abutment Burn-out Coping

Neo Micro Abutment CoCr Coping

32N.cm

10N.cm

10N.cm

or

Installation Sequence

118.297

118.317

Bridge

Crown

2Neo Micro Abutment

Titanium Coping

10N.cm

116.270

116.269

Neotorque*

Titanium

116.270

116.269

Neotorque*

Titanium

116.270

116.269

Neotorque*

Titanium

*Application of a film carbon-based coat that provides a lower friction coefficient, resulting in increased pre-load.

101.091 Hybrid Repositionable (conventional/digital)

2

Neo Screwdriver Torque Connection

Neo Screwdriver Torque Connection

Torque Wrench Manual Screwdriver Torque

++ +

1

HexagonalProsthetic Driver

Torque Wrench

3

108.178108.182

Micro Abutment Impression Coping Slim Closed Tray for single-unit prosthesis

Open Tray for multiple-unit prosthesis

or

Micro Abutment Analog

Page 11: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

021020

Recommended for anterior region.

Single-unit cement-retainedprosthesisGM Anatomic Abutment

Gingiva color for

esthetic outcomes

Exact

Consider in addition 1.5 - 2.0 mm for the restorative material

Minimum interocclusal space of 4.9 mm from the mucosa level

Unlocking feature

Click retention for

provisional copings

ororor

Installation Sequence

2

108.160 108.162

108.161 108.163

Regular Regular

Long Long

GM Implant Exact Impression Coping Closed and Open Tray

101.074 Conventional101.075

Ø 5.0/6.0

101.103 Hybrid Repositionable(conventional/digital)

101.090

GM Implant Analog

GM Exact Click Narrow Anatomic Abutment 118.334

Click Provisional Coping

118.335GM Exact Click Anatomic Abutment

Impression of the GM Exact Click Anatomic Abutment

Lab stage

Finalized prosthesis

Lab stage

Finalized prosthesis

1

Neo Screwdriver Torque Connection

Torque Wrench

+

Neo Screwdriver Torque Connection

Manual Screwdriver Torque

2

+

101.089

Ø 5.0/6.0Ø 3.5/3.75 Ø 4.0/4.3

114.752 114.753 114.754

3.5 mm2.5 mm1.5 mm

1GM Exact Click Anatomic Abutment

20N.cm

114.758 114.759 114.760

3.5 mm2.5 mm1.5 mm

1GM Exact Click Narrow Anatomic Abutment

20N.cm

1

114.755 114.756 114.757

3.5 mm2.5 mm1.5 mm

1GM Exact Click Anatomic Abutment 17°

20N.cm

114.761 114.762 114.763

3.5 mm2.5 mm1.5 mm

GM Exact Click Narrow Anatomic Abutment 17°

20N.cm

Page 12: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

023022

GM Universal AbutmentSingle-unit cement-retainedprosthesis

Exact

Unlocking feature

Ø 3.3 / 4.5mm

Ø 3.3 / 4.5mm

Click retention for

provisional copings

Consider in addition 1.5 - 2.0 mm for the restorative material

Minimum interocclusal space of 4.9 mm from the mucosa level

Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

4 m

m6

mm

1 11GM Exact Click

Universal AbutmentGM Exact Click

Universal Abutment 17ºGM Exact Click

Universal Abutment 30º

Click Universal AbutmentImpression Coping

Click Universal AbutmentProvisional Coping

Universal Abutment Burn-out Coping

Hybrid Repositionable(conventional/digital)

20N.cm

20N.cm

20N.cm

Installation Sequence

oror

1

Neo Screwdriver Torque Connection

Torque Wrench

+

114.566 114.542

114.572 114.545

114.567 114.543

114.573 114.546

114.568 114.544

114.574 114.547

114.569 114.554

114.575 114.557

114.570 114.555

114.576 114.558

114.571 114.556

114.577 114.559

114.578 114.548

114.584 114.551

114.579 114.549

114.585 114.552

114.580 114.550

114.586 114.553

114.581 114.560

114.587 114.563

114.582 114.561

114.588 114.564

114.583 114.562

114.589 114.565

Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

5.5 mm 3.5 mm4.5 mm 2.5 mm3.5 mm 1.5 mm2.5 mm 3.5 mm1.5 mm 2.5 mm0.8 mm 1.5 mm

4 m

m6

mm

Click (conventional)

108.172

108.173

108.174

108.175

Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

4 m

m6

mm

118.304

118.305

118.306

118.307

Ø 3.3 Ø 3.3

Ø 4.5 Ø 4.5

4 m

m

6 m

m

101.097 101.098

101.099 101.100

Ø 3.3 Ø 3.3

Ø 4.5 Ø 4.5

4 m

m

6 m

m

101.070 101.071

101.072 101.073

Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

4 m

m6

mm

118.181

118.182

118.183

118.184

Universal Abutment Analog

Page 13: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

025024

GM Titanium BaseSingle-unit cement-retainedprosthesis

Single-unit screw-retainedprosthesis

OR

Exact

Ø 3.5/4.5/5.5/6.5 mm

Ø 3.5/4.5/5.5/6.5 mm

Customizable up to 4 mm high

Consider in addition 1.5 - 2.0 mm for the restorative material

Minimum interocclusal space of 4.9 mm from the mucosa level

With removable screw.

Accessories

116.285

Replacement Sterile

Screws

Neotorque* 116.286Titanium *Application of a film carbon-based coat that provides a lower friction coefficient, resulting in increased pre-load.

Intraoral Model Scanning

Workflow Options

Conventional

118.322 118.325 118.329

118.323 118.327 118.342

4.0 mm

6.0 mm

Ø 5.5Ø 4.5Ø 3.5

1

Neo Screwdriver Torque Connection

Torque Wrench

+

Neo Screwdriver Torque Connection

Manual Screwdriver Torque

2

+

GM Titanium Base Burn-out Coping

108.160 108.162

108.161 108.163

Regular Regular

Long Long

2GM Implant Exact Impression CopingClosed and Open Tray

108.160 108.162

108.161 108.163

Regular Regular

Long Long

2GM Implant Exact Impression Coping Closed and Open Tray

108.181

GM Exact Implant Scanbody

2

108.183

GM Implant Intraoral Scanbody

2

GM Implant Analog

GM Implant Analog GM Implant Analog

101.103 Hybrid Repositionable(conventional/digital)

101.090101.089

Ø 5.0/6.0Ø 3.5/3.75 Ø 4.0/4.3

101.074 Conventional101.075

Ø 5.0/6.0

101.103Hybrid Repositionable(conventional/digital)101.090101.089

Ø 5.0/6.0Ø 3.5/3.75 Ø 4.0/4.3

101.074 Conventional101.075

Ø 5.0/6.0

101.103Hybrid Repositionable(conventional/digital)101.090101.089

Ø 5.0/6.0Ø 3.5/3.75 Ø 4.0/4.3

135.260 135.266135.261 135.267135.262 135.268

135.263 135.269135.264 135.270

135.272

135.284

135.287

135.321

135.278

135.290

135.293

135.325

135.273

135.285

135.319

135.288

135.322

135.279

135.291

135.323

135.294

135.326

135.274

135.286

135.320

135.280

135.292

135.324

135.275 135.281135.276 135.282

Ø 3.5

Ø 3.5

Ø 3.5

Ø 3.5

Ø 4.5

Ø 5.5

Ø 6.5

Ø 5.5

Ø 6.5

Ø 4.5

Ø 4.5

Ø 5.5

Ø 6.5

Ø 5.5

Ø 6.5

Ø 4.5

4.5 mm 4.5 mm3.5 mm 3.5 mm

2.5 mm 2.5 mm1.5 mm 1.5 mm0.8 mm 0.8 mm6 mmGM Exact Titanium Base

20N.cm

20N.cm

4 mm1

Page 14: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

027026

GM Titanium Base for BridgeWith removable screw.

Multiple-unit screw-retainedprosthesis

Multiple-unit cement-retainedprosthesis

OR

Ø 3.5/4.5/5.5mm

Accessories

116.285

Replacement Sterile

Screws

Neotorque* 116.286Titanium *Application of a carbon-based film coat that provides a lower friction coefficient, resulting in increased pre-load.

Intraoral Model Scanning

Workflow Options

108.160 108.162

108.161 108.163

Regular Regular

Long Long

GM Implant Exact Impression Coping Closed and Open Tray

108.181

GM Exact Implant Scanbody

2

108.183

GM Implant Intraoral Scanbody

2

GM Implant Analog

GM Implant Analog

101.103 Hybrid Repositionable(conventional/digital)

101.090101.089

Ø 5.0/6.0Ø 3.5/3.75 Ø 4.0/4.3

101.074 Conventional101.075

Ø 5.0/6.0

101.103Hybrid Repositionable(conventional/digital)101.090101.089

Ø 5.0/6.0Ø 3.5/3.75 Ø 4.0/4.3

1

Neo Screwdriver Torque Connection

Torque Wrench

+

Neo Screwdriver Torque Connection

Manual Screwdriver Torque

2

+

135.304 135.305 135.307135.306 135.308

135.309

135.314

135.310 135.312

135.315 135.317

135.311 135.313

135.316 135.318

Ø 3.5

Ø 4.5

Ø 5.5

2.5 mm 4.5 mm1.5 mm 3.5 mm0.8 mm

20N.cmGM Titanium Base for Bridge 1

Page 15: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

029028

Titanium Base C for GM

Exact

Ø 4.65mm Cementable area: 4.7 mm

Single-unit cement-retainedprosthesis

Single-unit screw-retainedprosthesis

OR

With removable screw.

Accessories

116.285

Replacement Sterile

Screws

Neotorque* 116.286Titanium

Installation Sequence

Workflow

Intraoral Scanning with scanbodies

provided by Dentsply Sirona

Finalized Prosthesis

1Titanium Base C

for GM Exact

Ø 4.65

2.5 mm1.5 mm

3.5 mm

0.8 mm

135.229 135.230

135.232

135.231

5.5 mm4.5 mm

135.233 135.234

1

Neo Screwdriver Torque Connection

Torque Wrench

+

20N.cm

Step 1

Step 3

Step 4

Step 2

Gingiva height selection and ordering.

Design andmilling.

Finalization and fixation.

Intra-oral scanning.

Select the Titanium Base C for GM Exact gingival height.

Select in the CAD software the comparable third-party Ti-base and perform the digital design.

• Check the fit of milled restoration in the patient’s mouth and adapt it, if needed. • Cement the restoration on the Titanium Base C for GM Exact and insert it into the patient’s mouth.

Insert the Titanium Base C for GM Exact in the Neodent® implant.

Insert scanbody on the Titanium Base C for GM Exact.

Order the Titanium Base C for GM Exact.

Please note that the scanbody has to be purchased directy from equipment manufacturer.

Mill the digital design.

CEREC digital library compatibility

Library Sirona’s Products Compatible with implant System

Ti-base Scanbody

L 6431311

REF Scanbody Omnicam

REF Scanbody Bluecam / Ineos

6431295 inCoris ZI meso L

Griding block Implant manufacturer Implant system

Neodent® GM, CM, HE, IIPluss

NBB 3.4 L

NB A 4.5 L

SSO 3.5 L

S BL 3.3 L

S BL 4.1 L

BO 3.4 L

*Application of a carbon-based film coat that provides a lower friction coefficient, resulting in increased pre-load.

Page 16: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

031030

Single-unit cement-retainedprosthesis

Single-unit screw-retainedprosthesis

OR

Multiple-unit cement-retainedprosthesis

OR

Exact

Ø 15.8mm

Ø 11.5mm

Customizable area:

14.2 mm

Consider in addition 1.5 - 2.0 mm for the restorative material

Minimum interocclusal space of 4.9 mm from the mucosa level

GM Titanium Block for MEDENTiKA Holder

Accessories

116.285

Sterile Screws

sold separately

Neotorque* 116.286Titanium

Complete Digital Workflow

Semi Digital Workflow

108.181

108.183

2

2

12

GM Exact Implant Impression CopingClosed and Open Tray

GM Implant Scanbody

GM Implant Intraoral Scanbody

GM Exact Titanium Block

Finalized Prosthesis

with CADCAM process

1GM Exact Titanium Block

Finalized Prosthesis

with CADCAM process

108.162

108.163

Regular 108.160

108.161Long

20N.cm

Ø 11.5 mm

MEDENTiKA Holder

Ø 15.8 mm

20N.cm

135.252 135.253

20N.cm

Ø 11.5 mm

MEDENTiKA Holder

Ø 15.8 mm

20N.cm

135.252 135.253

GM Implant Analog

GM Implant Analog

1

Neo Screwdriver Torque Connection

Torque Wrench

+

Neo Screwdriver Torque Connection

Manual Screwdriver Torque

2

+

Hybrid Repositionable(conventional/digital)

Ø 5.0/6.0Ø 3.5/3.75 Ø 4.0/4.3

101.103 101.089 101.090

Conventional

Hybrid Repositionable(conventional/digital)

Ø 5.0/6.0Ø 3.5/3.75 Ø 4.0/4.3

101.103 101.089 101.090

101.074 101.075

Ø 5.0/6.0

*Application of a carbon-based film coat that provides a lower friction coefficient, resulting in increased pre-load.

Screw sold separately.

Page 17: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

033032

Single-unit cement-retainedprosthesis

Single-unit screw-retainedprosthesis

OR

Multiple-unit cement-retainedprosthesis

OR

GM Titanium Block forAG Holder

Accessories

116.285

Replacement Sterile

Screws

Neotorque* 116.286Titanium

Ø 12.0mm

Complete Digital Workflow

Semi Digital Workflow

108.181

108.183

2

2

1

1

2

GM Exact Implant Impression CopingClosed and Open Tray

GM Implant Scanbody

GM Implant Intraoral Scanbody

GM Exact Titanium Block

GM Exact Titanium Block

Finalized Prosthesis

with CADCAM process

Finalized Prosthesis

with CADCAM process

108.162

108.163

Regular 108.160

108.161Long

20N.cm

20N.cm

Ø 12.0 mm

Ø 12.0 mm

Amann Girrbach Holder

Amann Girrbach Holder

135.226

135.226

GM Implant Analog

GM Implant Analog

1

Neo Screwdriver Torque Connection

Torque Wrench

+

Neo Screwdriver Torque Connection

Manual Screwdriver Torque

2

+

Hybrid Repositionable(conventional/digital)

Ø 5.0/6.0Ø 3.5/3.75 Ø 4.0/4.3

101.103 101.089 101.090

Conventional

Hybrid Repositionable(conventional/digital)

Ø 5.0/6.0Ø 3.5/3.75 Ø 4.0/4.3

101.103 101.089 101.090

101.074 101.075

Ø 5.0/6.0

*Application of a carbon-based film coat that provides a lower friction coefficient, resulting in increased pre-load.

Screw sold separately.

Page 18: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

035034

GM CoCr AbutmentThe set includes one GM CoCr Abutment, one Titanium Screw and one GM Implant Analog.

Interocclusal height of 12.0 mm. Customizable up to 5.0 mm.

Indicated for GM Implants placed at bone leve.

Single-unit cement-retainedprosthesis

Single-unit screw-retainedprosthesis

OR

Exact

Ø 4.1/4.5/5.0 mm

GM CoCr Abutment SetØ 3.5 / 3.75

118.309 118.310 118.311

Ø 4.0 / 4.3 Ø 5.0 / 6.0

Consider in addition 1.5 - 2.0 mm for the restorative material

Minimum interocclusal space of 4.9 mm from the mucosa level

108.160 108.162

108.161 108.163

Regular Regular

Long Long

2

1

GM Implant Exact Impression CopingClosed and Open Tray

GM Implant Analog

GM Exact CoCr Abutment

20N.cm

20N.cm

1GM Pro Peek Abutment

or

Installation Sequence

1

Neo Screwdriver Torque Connection

Neo Screwdriver Torque Connection

Torque Wrench Manual Screwdriver Torque

+ +

2

2GM Healing for CoCr Abutment

106.237

106.238

106.239

Ø 3.5 / 3.75

Ø 4.0 / 4.3

Ø 5.0 / 6.0

Page 19: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

037036

Interocclusal height of 10 mm

(can be customized up to 4.0

mm)

Customizable area made of titanium

A minimum height of 4 mm of the customizable area must be kept

With retentive grooves for acrylic material and allows customization

Exact

Ø 3.5/4.5 mm

Ø 3.5/4.5 mm

Consider in addition 1.5 - 2.0 mm for the restorative material

TemporaryProstheses

Channels of

customizations

GM Temporary Abutment

1GM Temporary Abutment

for Crown

Customization

1

Neo Screwdriver Torque Connection

Torque Wrench

+

Installation Sequence

1GM Temporary Abutment

for Bridge

TemporaryProsthesis

118.344 118.345 118.346 118.347

118.348 118.349 118.350 118.351

Ø 3.5

Ø 4.5

3.5 mm2.5 mm1.5 mm0.8 mm

118.352 118.353 118.354 118.355

118.356 118.357 118.358 118.359

Ø 3.5

Ø 4.5

3.5 mm2.5 mm1.5 mm0.8 mm

Page 20: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

039038

Unlocking feature

Interocclusal height of 9.2

mm (can be customized up

to 5.0 mm)

GM Pro Peek AbutmentBiocompatible Peek of easy customization

Exact

Ø 6.0 mm

Ø 4.5 mm

Temporaryprosthesis

Consider in addition 1.5 - 2.0 mm for the restorative material

114.738 114.739 114.740 114.741 114.742 114.743

114.744 114.745 114.746 114.747 114.748 114.749

Ø 4.5

Ø 6.0

5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mm

1GM Pro Peek Abutment

In mouth customization

1

Neo Screwdriver Torque Connection

Torque Wrench

+

Installation Sequence

Page 21: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

041040

GM Novaloc

Demounting Tool for Mounting Inserts for Analogs

Mounting and Demounting Tool for Retention Inserts

Accessories

2010.731-STM 2010.741-STM

Matrix Housing Extractor

2010.751-STM

2010.723-STMProcessing Spacer

2010.725-STMMounting Insert

2010.101Equipment Box

Angled version with removable screw

2.5 mm1.5 mm0.8 mm

4 Units

GM Novaloc

Forming/Fixing Matrix

Installation Sequence

1

20N.cm

5.5 mm4.5 mm3.5 mm

2.5 mm1.5 mm0.8 mm

GM Novaloc 15° 1

20N.cm

5.5 mm4.5 mm3.5 mm

or

Mounting Collar

Matrix Housing(including Processing Spacer)

Attachment Analog Attachment Analog 15°

2010.721-STM 2010.720-STM

2010.722-STM

2010.724-STM

2010.702-STM PEEK

2010.701-STM Titanium

Retention Insert

Green (approx. 1650 g)

Blue (approx. 2100 g)

Black (approx. 2550 g)

Red (approx. 300 g)

White (approx. 750 g)

Yellow (approx. 1200 g)

2010.710-STM

2010.711-STM

2010.712-STM

2010.713-STM

2010.714-STM

2010.715-STM

1

Neo Screwdriver Torque Connection

Torque Wrench

+

2010.703-STM With attachment

102.161 102.162 102.163

102.164 102.165 102.166

102.167 102.168 102.169

102.170 102.171 102.172

Page 22: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

043042

Measurements GM Anatomic Abutment

114.755 114.756 114.757

7,3

5,8

Tra

ns

mu

co

sa

l

4,856,05

7,3

5,8

3,5

2,5

1,5

6,1

4,8

Tra

ns

mu

co

sa

l

4,254,75

Narrow Anatomic Abutment Anatomic Abutment

Narrow Anatomic Abutment 17° Anatomic Abutment 17°

114.761 114.762 114.763

6,1

4,8

3,5

2,5

1,5

Measurements GM Mini Conical Abutment

17°

30°

45°

2,9

3,9

4,9

5,9

5,9

3,9

4,9

4,9

1,5

1,5

1,5

3,5

3,5

2,5

2,5

2,5

115.249

115.252

115.267

115.250

115.253

115.268

115.251

115.254

Page 23: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

045044

Ø 3.3 / 17º

Ø 3.3 / 17º

Ø 4.5 / 17º

Ø 4.5 / 17º

4 mm chimney height

6 mm chimney height

4 mm chimney height

6 mm chimney height

4,8

4,8

3,8

3,8

3,5

3,5

2,5

2,5

2,8

2,8

3,5

3,5

3,5

3,5

2,5

2,5

2,5

2,5

1,5

1,5

1,5

1,5

4,5

4,5

114.542

114.545

114.543

114.546

114.544

114.547

114.548

114.551

114.549

114.552

114.550

114.553

Measurements GM Universal Abutment

17°

Ø 3.3 / 30º Ø 4.5 / 30º

4 mm chimney height 4 mm chimney height

5,8

5,8

4,8

4,8

4,2

4,2

3,2

3,2

3,8

3,8

3,5

3,5

3,5

3,5

2,5

2,5

2,5

2,5

1,5

1,5

1,5

1,5

5,2

5,2

Ø 3.3 / 30º Ø 4.5 / 30º

6 mm chimney height 6 mm chimney height

114.554

114.557

114.555

114.558

114.556

114.559

114.560

114.563

114.561

114.564

114.562

114.565

30°

Page 24: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

047046Grand Morse® Kits

Grand Morse® Surgical KitAutoclavable polymer case.The Kit presents two compositions:- Complete: for Helix GM®, Drive GM® and Titamax GM® implants;- Helix®: for Helix GM® implants.

To order the complete composition

of the kit, with all instruments

already assembled on the tray,

use code 110.302.

Articles

Note: Items that compose Neodent® Kits are sold separately.

CompleteComplete Helix®Helix®

103.399

103.402

103.405

103.408

103.411

103.427

105.131

104.060

105.130

104.028

105.129

128.019

128.020

128.021

128.022

128.023

128.028

129.004

129.001

104.050

103.426

110.288

103.162

103.213

103.164

103.166

103.167

103.168

103.163

103.170

103.414

103.415

103.416

103.417

103.418

103.419

103.420

103.421

103.422

103.423

103.425

Tapered Drill 3.5

Tapered Drill 3.75

Tapered Drill 4.0

Tapered Drill 4.3

Tapered Drill 5.0

Tapered Drill 6.0

GM Implant Driver - Contra-Angle

Neo Screwdriver (Medium)

GM Implant Driver - Torque Wrench (Long)

Manual Implant Driver - Contra-Angle

GM Implant Driver - Torque Wrench (Short)

Direction Indicator 2.8/3.5

Direction Indicator 3.0/3.75

Direction Indicator 3.3/4.0

Direction Indicator 3.6/4.3

Direction Indicator 4.3/5.0

Height Measurer GM

Depth Probe

Titanium Tweezers

Torque Wrench

Drill Extension

GM Surgical Kit Case

Twist Drill 2.0 Plus

Pilot Dril 2.0/3.0 Plus

Twist Drill 3.0 Plus

Twist Drill 3.3 Plus

Twist Drill 3.8 Plus

Twist Drill 4.3 Plus

Twist Drill 2.8 Plus

Initial Drill Plus

Pilot Drill GM 2.8/3.5

Pilot Drill GM 3.0/3.75

Pilot Drill GM 3.3/4.0

Pilot Drill GM 4.3

Pilot Drill GM 4.3/5.0

Tapered Contour Drill 3.5

Tapered Contour Drill 3.75

Tapered Contour Drill 4.0

Tapered Contour Drill 4.3

Tapered Contour Drill 5.0

Tapered Drill 2.0

Page 25: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

049048

Autoclavable polymer case.

Articles110.294

105.146

105.135

105.136

105.138

105.137

105.133

105.132

105.134

104.005

128.028

104.050

GM Prosthetic Kit Case

Neo Screwdriver Torque Connection - Contra-angle (Extra-short)

Neo Screwdriver Torque Connection - Contra-angle (Short)

Neo Screwdriver Torque Connection - Contra-angle (Medium)

Hexagonal Prosthetic Driver - Contra-angle

Hexagonal Prosthetic Driver - Torque Wrench

Neo Screwdriver Torque Connection (Short) - Torque Wrench

Neo Screwdriver Torque Connection (Medium) - Torque Wrench

Neo Screwdriver Torque Connection (Long) - Torque Wrench

Manual Screwdriver Torque

GM Height Measurer

Torque Wrench

Grand Morse® Prosthetic Kit

Note: Items that compose Neodent® Kits are sold separately.

To order the complete composition

of the kit, with all instruments

already assembled on the tray,

use code 110.304.

Articles110.295

114.772

114.773

114.774

114.775

114.776

114.777

114.778

114.779

114.780

114.781

114.782

114.783

114.784

114.785

114.786

114.787

GM Try-In Kit Case

GM Abutment Try-In 3.3X6X0.8

GM Abutment Try-In 3.3X6X1.5

GM Abutment Try-In 3.3X6X2.5

GM Abutment Try-In 3.3X6X3.5

GM Abutment Try-In 3.3X6X4.5

GM Abutment Try-In 3.3X6X5.5

GM Abutment Try-In 4.5X6X0.8

GM Abutment Try-In 4.5X6X1.5

GM Abutment Try-In 4.5X6X2.5

GM Abutment Try-In 4.5X6X3.5

GM Abutment Try-In 4.5X6X4.5

GM Abutment Try-In 4.5X6X5.5

GM Abutment Try-In 17° 3.3X6X1.5

GM Abutment Try-In 17° 3.3X6X2.5

GM Abutment Try-In 17° 3.3X6X3.5

GM Abutment Try-In 17° 4.5X6X1.5

114.788

114.789

114.790

114.791

114.792

114.793

114.794

114.795

114.796

114.797

114.798

114.799

114.800

114.801

104.058

128.028

GM Abutment Try-In 17° 4.5X6X2.5

GM Abutment Try-In 17° 4.5X6X3.5

GM Abutment Try-In 30° 3.3X6X1.5

GM Abutment Try-In 30° 3.3X6X2.5

GM Abutment Try-In 30° 3.3X6X3.5

GM Abutment Try-In 30° 4.5X6X1.5

GM Abutment Try-In 30° 4.5X6X2.5

GM Abutment Try-In 30° 4.5X6X3.5

GM Anatomic Abutment Try-In 1.5

GM Anatomic Abutment Try-In 2.5

GM Anatomic Abutment Try-In 3.5

GM Lateral Anatomic Abutment Try-In 1.5

GM Lateral Anatomic Abutment Try-In 2.5

GM Lateral Anatomic Abutment Try-In 3.5

Neo Manual Screwdriver (Short)

GM Height Measurer

Grand Morse® Try-In Kit

Autoclavable polymer case.

Note: Items that compose Neodent® Kits are sold separately.

To order the complete composition

of the kit, with all instruments

already assembled on the tray,

use code 110.305.

Page 26: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

051050

Increasing expectations for shortened treatment duration represent a significant challenge for dental professionals especially in patients with anatomical deficiencies. The Neodent® Implant System offers an optimized solution for immediate fixed treatment protocols in edentulous patients even with severe atrophic maxilla. Neodent® NeoArch® allows to significantly improve patient satisfaction and quality of live by immediately restoring function and esthetics (10).

NEODENT® NEOARCH®

IMMEDIATE FIXED FULL-ARCH SOLUTION

A SMILE FOR EVERYONE • Different implants techniques to avoid the use of grafting procedure(11).

• Optimized implant design to achieve high primary stability in all bone types(12).

Immediate function resulting in shorter treatment times.

• One connection regardless of the diameters.

• Unique connection combining Platform Switching associated with a deep 16° Morse taper including an internal

indexation.

Immediate peace of mind thanks to a stable foundation.

• A broad gingival height abutment range to cater the patient’s needs.

• Options of straight and angled abutments (17°, 30° and 45°).

Immediate natural-looking esthetics with versatile restorative options.

A implant system designed for predictable immediate treatments in all bone types even with different conditions of the residual alveolar bone.

SOLUTIONS FOR ALL CLINICAL NEEDS

BONE RESORPTION

Helix GM® Helix GM® Long Zygoma GM™

Page 27: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

053052

Helix GM® Long

Available with:

Implants Description:

• Full dual tapered implant;

• Hybrid contour with a cylindrical coronal part and conical on the

apical area;

• Active apex including a soft rounded small tip and helicoidal

flutes;

• Dynamic progressive thread design: from compressing

trapezoidal threads on the coronal area to self-tapping threads

on the apical part;

• Double lead threaded implant;

• Holder integrated to the implant body, which adapt in the

packaging;

• Neoporos surface;

• Grand Morse® connection.

Drilling features:

• For infraosseous positioning it is recommended to

add 1 to 2 mm in length to the implant during surgical

instrumentation.

• Drilling speed: 500-800 rpm;

• Implant insertion speed: 30 rpm;

• Maximum torque for implant placement: 60 N.cm.

PRODUCT FEATURES:

Indications:

• Indicated for surgical intraoral installation, in bone types III/

IV for cases of total or partial edentulism and for multiple-

unit prostheses.

®

Initial Ø 3.75*Ø 2.35* Ø 4.0*

Drill Sequence

Bone types III and IV

* Drills available for both conventional and Guided Surgery procedures.

OptionalØ 3.75 mm

Ø 4.0 mm Optional

22.5 mm20.0 mm 25.0 mm

109.1043

109.1046

109.1044

109.1047

109.1045

109.1048

Ø 3

.75

Ø 4

.0

NeoPoros

NeoPoros

Helix GM® Long implants

117.021 117.022

GM Cover Screw

:: Use the manual Neo Screwdriver (104.060);:: Do not exceed the insertion torque of 10 N.cm.

0 mm 2 mm

106.207 106.208 106.209 106.210 106.211 106.212

106.213 106.214 106.215 106.216 106.217 106.218

Ø 3.3

Ø 4.5

5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mm

:: Use the manual Neo Screwdriver (104.060);:: Do not exceed the insertion torque of 10 N.cm.

GM Healing Abutment

Profile

103.453 103.462 103.463 103.464

106.223 106.224 106.225 106.226 106.227

106.228 106.229 106.230 106.231 106.232

Ø 5.5

Ø 7.0

6.5 mm5.5 mm4.5 mm3.5 mm2.5 mm1.5 mmProfile

GM Customizable Healing Abutments

Page 28: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

055054

Zygoma GM™

Available with:

Implants Description:

• Hybrid contour with a cylindrical coronal part and conical

on the apical area;

• The apex has a conical profile with a spherical tip and three

equally spaced helical flutes;

• Trapezoidal thread and progressive increase of the thread

depth at the apical portion;

• Tissue Protect: portion with interrupted thread, near the

cervical region, indexed to the hexagon face;

• Holder integrated to the implant body, which adapt in the

packaging;

• Neoporos surface;

• Grand Morse® connection.

Drilling features:

• Drilling speed: 800-1200 rpm;

• Lateral Direction Drill speed: 600-800 rpm;

• Implant insertion speed: 30 rpm;

• Maximum torque for implant placement: 60 N.cm.

PRODUCT FEATURES:

Indications:

• Indicated for surgical procedures in the the posterior

region of the maxilla and in the zygoma, in cases of severe

maxilla resorption. Zygomatic Implants may be used in

immediate loading procedures when there is good primary

stability and appropriate occlusal loading.

®

PilotØ 2.3/3.2

LateralDirection

Ø 4.0Ø 2.35* Ø 4.0Ø 3.75

Drill Sequence

OptionalOptionalØ 4.0 mm

30.0 mm 35.0 mm 40.0 mm37.5 mm 42.5 mm 45.0 mm 47.5 mm 50.0 mm 52.5 mm 55.0 mm

109.1049 109.1050 109.1051 109.1052 109.1053 109.1054 109.1055 109.1056 109.1057 109.1058

Ø 4

.0

NeoPoros

Zygoma GM™ Implants

* Drill available for both conventional and Guided Surgery procedures.

103.455 103.458 103.465 103.456 103.457

117.021 117.022

GM Cover Screw

:: Use the manual Neo Screwdriver (104.060);:: Do not exceed the insertion torque of 10 N.cm.

0 mm 2 mm

Page 29: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

057056

Helix GM® Long Compact Surgical Kit

Autoclavable polymer case.

ArticlesTwist Drill For Helix GM® Long 4.0mm

Helix GM® Long X-ray Positioner

GM Angle Measurer 17º

GM Angle Measurer 30º

GM Angle Measurer 45º

Regular Guided Surgery GM Connection for Torque Wrench

Regular Guided Surgery GM Connection - Contra-angle

Neo Manual Screwdriver (medium)

GM Implant Driver - Torque Wrench (short)

GM Implant Driver - Contra-angle

Torque Wrench

Helix GM® Long Compact Surgical Kit Case

Guided Surgery Drill 1.3mm

Guided Surgery Guide Clamp

Drill Guide For NGS Helix GM® Long 2.0/2.35mm

Drill Guide For NGS Helix GM® Long 3.75/4.0mm

Twist Drill For NGS Helix GM® Long 2.35mm

Twist Drill For NGS Helix GM® Long 3.75mm

Twist Drill For NGS Helix GM® Long 4.0mm

Helix GM® Long Initial Drill 2.0mm

Twist Drill For Helix GM® Long 2.35mm

Twist Drill For Helix GM® Long 3.75mm

110.300

103.395

125.100

125.140

125.141

103.459

103.460

103.461

103.453

103.462

103.463

103.464

129.021

128.032

128.033

128.034

105.143

105.140

104.060

105.129

105.131

104.050

Note: Items that compose Neodent® Kits are sold separately.

Zygoma GM™ Surgical Kit

Autoclavable polymer case.

ArticlesZygoma GM™ Probe 2.35mm

Zygoma GM™ Probe 4.0mm

GM Angle Measurer 17º

GM Angle Measurer 30º

GM Angle Measurer 45º

GM Height Measurer

Neo Manual Screwdriver (medium)

GM Implant Driver - Torque Wrench (short)

GM Implant Driver - Contra-angle

Torque Wrench

Zygoma GM™ Surgical Kit Case

Guided Surgery Drill 1.3mm

Guided Surgery Guide Clamp

Drill Guide For Ngs Zygoma GM™ 2.35mm

Twist Drill For Ngs Zygoma GM™ 2.35mm

Twist Drill For Zygoma GM™ 2.35mm

Twist Drill For Zygoma GM™ 3.75mm

Twist Drill For Zygoma GM™ 4.0mm

Lateral Direction Drill For Zygoma GM™ 4.0mm

Pilot Twist Drill For Zygoma GM™ 2.3/3.2mm

Zygoma GM™ Installation Driver

110.299

103.395

125.100

125.139

103.454

103.455

103.456

103.457

103.458

103.465

104.063

129.022

129.023

128.032

128.033

128.034

128.028

104.060

105.129

105.131

104.050

Note: Items that compose Neodent® Kits are sold separately.

Page 30: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

059058Grand Morse® Instruments

Ø 3.3/4

Ø 5.3/6

Ø 3.6/4.3Ø 3/3.75

Ø 4.3/5.3

Ø 2.8/3.5

Ø 3.8/4.3

Ø 2/3

Ø 4.3/5

103.170

103.414

103.214

103.213

103.418

103.415

103.215

103.416

103.221

103.417

Initial Drill

Pilot Drills

:: Available in surgical steel;:: 2.0mm diameter.

:: Available in surgical steel;:: Increasing the surgical

alveolus diameter ridge, easing the penetration of the next drill or the implant.

:: Available in surgical steel;:: Drill sequence for Helix GM®

and Drive GM® Implants.

Ø 4.0 Ø 5.0 Ø 6.0Ø 3.75 Ø 4.3Ø 3.5Ø 2.0

Long 43 mm

Short 31 mm

Regular 35 mm 103.399103.425

103.401

103.400

103.402 103.408

103.404 103.410

103.403 103.409

103.405 103.411

103.407 103.413

103.406 103.412 103.427

Tapered Drills

Ø 4.3+ Ø 5.0+Ø 4.0+Ø 3.75+Ø 3.5+

103.420103.419 103.421 103.422 103.423

GM Tapered Contour Drills

:: For preparing the implant bed in bone types I and II for Helix GM® Implants.

Short 31 mm

Regular 35 mm

Long 43 mm

Twist Drills

:: Available in surgical steel;

:: Drill sequence for Titamax GM® Implants.

Ø 3.3Ø 3.0 Ø 4.3Ø 2.8Ø 2.0 Ø 3.8

103.224

103.164

103.230

103.227

103.168

103.223

103.163

103.229

103.222

103.162

103.228

103.226

103.167

103.225

103.166

103.231

Page 31: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

061060

Helix GM® Long Drills

Helix GM® Long Drills for Guided Surgery

Zygoma GM™ Lateral Direction Drill

:: Available in surgical steel;:: Drill sequence for Helix GM® Longimplants.

:: Available in surgical steel;:: Spherical tip with guide pin and helical

blades for preparing the site for the implant placement in the exteriorized technique.

:: Available in surgical steel;:: Drill sequence for Helix GM® Long

implants on Guided Surgery.

Zygoma GM™ Drills

:: Available in surgical steel;:: Drill sequence for Zygoma GM™

implants.

Zygoma GM™ Drill for Guided Surgery

:: Available in surgical steel;:: After using the first drill, the surgical guide must be

removed and the conventional protocol must be started.

Initial

PilotØ 2.3/3.2

Ø 4.0

103.453

103.455

103.454

Ø 4.0

Ø 4.0

Ø 4.0

Ø 3.75

Ø 3.75

Ø 3.75

Ø 2.35

Ø 2.35

Ø 2.35

Ø 2.35

103.462

103.465

103.458

103.459

103.463

103.456

103.460

103.464

103.457

103.461

GM Height Measure

:: Available in titanium;:: For selecting GM prosthetic abutments;:: Marks corresponding to transmucosa heights.:: Can be used as X-Ray Positioner.

128.028

1.53.55.5

2.5

6.5

4.5

0.8

105.131

GM Implant Driver - Contra-Angle

:: To capture the implant directly from the packaging;:: To place GM Implants with contra-angle, or attached to a

manual driver for contra-angle connections (104.028) for hand placement;

:: With six dimples to indicate the hex index face position;:: The laser marks indicate the depth of implant placement,

bone level, 1 and 2mm infra-bone and last marking (3mm) biological space;

:: Maximum torque 35 N.cm.

105.129

103.426

105.130

GM Implant Driver - Torque Wrench

Drill Extension

:: To place GM Implants with the Torque Wrench (104.050);:: With six marks to indicate the hex index face position;:: The laser marks indicate the depth of implant placement,

bone level, 1 and 2mm infra-bone and last marking (3mm) biological space;

:: Maximum torque: 60 N.cm.

:: Available in surgical steel;:: Fit the drill directly into the Drill Extension.

Long30 mm

Short22 mm

Direction Indicators

:: Available in titanium;:: Instrument to guide the implant

position;:: Diameter of central band corresponds

to GM Implant diameter;:: Smaller side to be used after Ø2.0mm

drill;:: Larger side to be used after the last drill

before implant installation.

3.6/4.3 4.3/5.0 3.3/4.03.0/3.752.8/3.5

128.020128.019 128.021 128.022 128.023

Page 32: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

063062

104.028

Manual Implant Drivers

:: Available in surgical steel;:: For Contra-angle connections: connected to GM

Implant Driver, it becomes a manual driver for implant placement.

:: For Torque Wrench connections: connected to screwdrivers, it provides manual torque.

104.005

Contra-angleConnections

Torque WrenchConnections

Short16.5 mm

Medium22 mm

Long32 mm

105.132105.133 105.134

Neo Screwdriver Torque Connection - Torque Wrench

:: Available in surgical steel;:: Yellow color for line identification.:: Long Neo Screwdriver Torque Connection - Wrench

(105.134) recommended for Impression Copings and Copings for screw-retained prostheses.

Short21 mm

Short24 mm

ExtraShort

16.5 mm

Torque Wrench

Medium25 mm

Medium31 mm

Contra-angle

Long37 mm

104.060

105.136

105.138

104.058

105.135105.146

105.137

104.059

Neo Screwdriver

Neo Screwdriver Torque Connection - Contra-angle

:: Available in surgical steel;:: Yellow color for line identification.:: Long Neo Manual Screwdriver (104.059)

recommended for Impression Copings and Copings for screw-retained prostheses.

:: Available in surgical steel;:: Yellow color for line identification;:: Medium Neo Screwdriver Torque Connection - Contra-

angle (105.136) recommended for Impression Copings and Copings for screw-retained prostheses.

:: Extra Short Neo Screwdriver Torque Connection - Contra-angle (105.146) recommended for Impression Copings, Cover Screws and Healing Abutments.

:: Available in surgical steel;:: To install and apply torque over straight GM Mini

Conical Abutments and GM Micro Abutments;:: Yellow color for line identification;:: Hexagonal Prosthetic Driver for Contra-angle: to

install GM Mini Conical Abutment (straight).

Hexagonal Prosthetic Driver

GM Bone Profile Drill with Guide

:: Available in surgical steel;:: Used in the surgical second step;:: Conforms the bone around the

implant platform, preparing the emergence profile to be suitable to prosthetic components.

103.424

128.032 128.033 128.034

:: Available in titanium;:: Angles: 17°, 30° and 45°;:: To a more accurate selection and planning

of the abutments angulation during the prosthetic phase.

128.030 128.031

:: Available in titanium;:: Angles: 17° and 30°;:: To select and plan the abutments angulation

during surgical procedures;:: Suggested use: after Twist Drill 2.0.

30°17°

Angle Measurer for Drill 2.0

GM Angle Measurer

30° 45°17°

Page 33: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

065064

Torque Wrench

:: Available in surgical steel;:: Fitting for square connections;:: Collapsible Wrench that allows for proper

assembly cleaning;:: For full instructions see page 99.

104.050

104.063

129.021

Helix GM® Long X-ray Positioner

Zygoma GM™ Probes

:: Indicated for evaluation of the osteotomy depth in the implant placement procedure.

:: Available in Stainless Steel;:: The probe for the drill Ø2.35 mm has a tip design in L;:: The probe for the drill Ø4.0 mm has a tip with a design

similar to the apex of the drill that allows identifying the correct drilling depth for implant anchorage.

:: Instrument for application of manual torque.

Zygoma GM™ Installation Driver

Ø 4.0Ø 2.35

129.022 129.023

125.140

125.139

125.141:: Instrument with the purpose of guiding the drills during the bone bed preparation according to the guided surgery technique.

:: Instrument with the purpose of starting the Zygomatic Surgery guided.

Helix GM® Long Drill Guide for Guided Surgery

Zygoma GM™ Drill Guide for Guided Surgery

Ø 2.0/2.35

Ø 2.35

Ø 3.75/4.0

NEODENT - DOŻYWOTNIA GWARANCJA

ILAPEO

Najlepsze decyzje są oparte na faktach.

IMPLANTY: Dożywotnia gwarancja. Wymiana na taki sam lub podobny implant.

KOMPONENTY IMPLANTÓW: 10 lat gwarancji na łączniki metalowe.

Celem programu Neodent Originals jest zapewnienie jakości i trwałości produktów Neodent. Dlatego stomatolodzy, którzy używają w swoich procedurach produktów Neodent mogą liczyć na gwarancjędotyczącą każdego rozwiązania.

Neodent kładzie dużą wagę na edukację i szkolenia w celu zapewnienia jakości oraz standardów leczenia i opieki nad pacjentem. Czyni to poprzez ILAPEO (Latin American Institute of Dental Education), jeden z największych na świecie ośrodków szkolenia dedykowany implantologii, który oferuje kursy dla tysięcy uczestników z całego świata każdego roku. ILAPEO proponuje kursy podyplomowe i kursy mistrzowskie dla klinicystów. Jest to wspaniały powód, aby odwiedzić Brazylię....

25 LATA Dostarczamy wysokiej jakości rozwiązania implantologiczne

od ponad 24 lat

270,000 pacjentów było leczonych

implantami Neodent w Brazylii w 2014 roku

Neodent jest liderem w Ameryce Łacińskiej

- drugim co do wielkości rynku zbytu implantów.

NR1Więcej niżUdokumentowany

wskaźnik powodzenia

Więcej niż

NR2Jesteśmy drugą co do wielkości

firmą implantologicznąna świecie

150+naukowych artykułówu 3578 pacjentów

i publikacji

99.7%

100% wsparcie

dla naszych klientów

1,600,000 Sprzedajemy corocznie

ponad milion implantów

Edukacja, nauka, wsparcie i badania naukowe

w Curitiba, Brazylia

ILAPEOStraumann zwiększył

swoje udziały w Neodent do

Ponad

(w kwietniu 2015 roku)

lekarzy zostało przeszkolonych

w ośrodkach naukowych Neodent w Brazylii

35,000 profesjonalistów na świecie używa

implantów Neodent

100% 3,000

Page 34: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

067066

Grand Morse® Neodent® Guided SurgeryComplete: Helix® and Drive® Grand Morse® Implants portfolio;

Convenient: Color-coded instruments and symbol-marked;

Flexible: 2 sleeve height options;

Complatible with major guided surgery software.

Available in titanium;

Sold in bags with 10 units each.

Sleeves for Neodent® Guided Surgery System

Sleeve for Narrow Guided Surgery System 125.135

Sleeve for Regular Guided Surgery System 125.136

Sleeve for Wide Guided Surgery System 125.137

Sleeve of Setter for Guided Surgery System 125.138

Autoclavable polymer case.The Kit allows the use of Helix GM® and Drive GM® Implants in the Guided Surgery technique.

Articles

Note: Items that compose Neodent® Kits are sold separately.*Conventional guided surgery drills that can be replaced by the respective short version.

Neo Manual Screwdriver (Medium)

Tapered Contour Guided Surgery Drill 3.5*

Tapered Contour Guided Surgery Drill 3.75*

Tapered Contour Guided Surgery Drill 4.0*

Tapered Contour Guided Surgery Drill 4.3*

Tapered Contour Guided Surgery Drill 5.0*

Narrow Guided Surgery GM Pilot Drill 3.5

Regular Guided Surgery GM Pilot Drill 3.5

Guided Surgery GM Pilot Drill 3.75

Guided Surgery GM Pilot Drill 4.0

Guided Surgery GM Pilot Drill 4.3

Guided Surgery GM Pilot Drill 5.0

Narrow Guided Surgery Drill Guide 2.0/3.5

Regular Guided Surgery Drill Guide 2.0/3.5

Regular Guided Surgery Drill Guide 3.75/4.0

Regular Guided Surgery Drill Guide 4.3

Wide Guided Surgery Drill Guide 2.0/3.5

Wide Guided Surgery Drill Guide 4.0/4.3

Wide Guided Surgery Drill Guide 5.0/6.0

Narrow Tapered Contour Guided Surgery Drill Guide 3.5

Regular Tapered Contour Guided Surgery Drill Guide 3.5/3.75

Regular Tapered Contour Guided Surgery Drill Guide 4.0/4.3

Wide Tapered Contour Guided Surgery Drill Guide 5.0

Titanium Tweezers

Torque Wrench

GM Guided Surgery Surgical Kit Case

Guided Surgery 1.3

Guided Surgery Guide Clamp

Narrow Guided Surgery Punch - Contra-Angle

Regular Guided Surgery Punch - Contra-Angle

Wide Guided Surgery Punch - Contra-Angle

Guided Surgery Drill 2.0

Tapered Guided Surgery Drill 3.5*

Tapered Guided Surgery Drill 3.75*

Tapered Guided Surgery Drill 4.0*

Tapered Guided Surgery Drill 4.3*

Tapered Guided Surgery Drill 5.0*

Tapered Guided Surgery Drill 6.0*

Narrow Guided Surgery GM Connection - Contra-angle

Regular Guided Surgery GM Connection - Contra-angle

Wide Guided Surgery GM Connection - Contra-angle

Narrow Guided Surgery GM Connection for Torque Wrench

Regular Guided Surgery GM Connection for Torque Wrench

Wide Guided Surgery GM Connection for Torque Wrench

Narrow Guided Surgery GM Guide Stabilizer

Regular Guided Surgery GM Guide Stabilizer

Wide Guided Surgery GM Guide Stabilizer

Narrow Guided Surgery GM Guide Stabilizer (Long)

Regular Guided Surgery GM Guide Stabilizer (Long)

Guided Surgery GM H11 Connection for Torque Wrench

Neo Screwdriver Torque Connection - Contra-angle (Medium)

110.296

103.395

125.100

103.429

103.430

103.431

103.432

103.433

103.434

103.435

103.436

103.437

103.438

105.139

105.140

105.141

105.142

105.143

105.144

125.130

125.131

125.132

125.133

125.134

105.145

105.136

104.060

103.439

103.440

103.441

103.442

103.443

103.444

103.445

103.446

103.447

103.448

103.449

125.119

125.121

125.122

125.123

125.126

125.127

125.128

125.120

125.124

125.125

125.129

129.001

104.050

Grand Morse® Guided Surgery Surgical Kit

Page 35: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

069068

Guided Surgery Tapered Contour Drills

Ø 4.0+ Ø 5.0+Ø 3.75+ Ø 4.3+Ø 3.5+

Short 36.5 mm

Regular 41 mm 103.439

103.482

103.440 103.442

103.483 103.485

103.441 103.443

103.484 103.486

:: Available in surgical steel;:: Drill sequence for Helix GM®

Implants in the guided surgery technique for bone types I or II;

:: Fully guided technique with Short Drills indicated for 8, 10 or 11.5 mm long implants.

Guided Surgery Drill 1.3 and Guide Clamp

:: Drill available in surgical steel;:: Guide Clamp available in titanium;:: For initial fixation of the surgical guide.

Guide Clamp

Drill Ø 1.3

103.395 125.100

Guided Surgery Tapered Drills

Ø 4.0 Ø 5.0 Ø 6.0Ø 3.75 Ø 4.3Ø 3.5Ø 2.0Short

36.5 mm

Regular41 mm

103.433103.432

103.476

103.434 103.436

103.477 103.479

103.435 103.437

103.478 103.480 103.481

:: Available in surgical steel;:: Drill sequence for Helix GM®

and Drive GM® Implants in the guided surgery technique;

:: Fully guided technique with Short Drills indicated for 8, 10 or 11.5 mm long implants.

103.438

103.475

Guided Surgery GM Pilot Drills

Ø 4.0 Ø 5.0Ø 3.75 Ø 4.3Ø 3.5

Narrow

Regular 103.445

103.444

103.446 103.448103.447

:: Available in surgical steel;:: Color-coded according to the sleeve

diameter;:: Recommended for Helix GM® in bone

types I or II;:: Optional for Drive GM® in bone types III

or IV.

Wide 103.449

Guided Surgery Punch - Contra-Angle

:: Available in titanium;:: Color-coded according to the sleeve

diameter;:: To remove the mucosa before beginning

the osteotomy.

RegularNarrow Wide

103.429 103.431103.430

Guided Surgery Drill Guides

:: Available in titanium and stainless steel;

:: Color-coded according to the sleeve diameter;

:: To fit in the sleeve in the surgical guide;

:: To be used with correspondent drill diameter and type.

Narrow

Regular

Ø 3.75/4.0

125.122

Ø 4.3

125.123

Wide

Ø 5.0/6.0

125.128

Ø 2.0/3.5

125.121

125.119

125.126

Ø 4.0/4.3

125.127

Narrow

Regular

Ø 3.5+/3.75+

125.124

Ø 3.5+

125.120

Ø 4.0+/4.3+

125.125

Ø 5.0+

125.129Wide

Guided Surgery GM Connection - Contra-Angle

:: Available in stainless steel;:: Color-coded according to the sleeve

diameter;:: To start the implant placement through

the surgical guide.

RegularNarrow Wide

105.139 105.141105.140

Guided Surgery GM Connection - Torque Wrench

:: Available in stainless steel;:: Color-coded according to the sleeve

diameter;:: To finish the implant placement

through the surgical guide.

RegularNarrow Wide

105.142 105.144105.143

Guided Surgery GM H 11 Connection - Torque Wrench

:: Available in stainless steel;:: To finish the implant placement

through the surgical guide;:: To be used when the H11 sleeve

height is chosen.

105.145

Guided Surgery Guide Stabilizers

:: Available in titanium;:: Color-coded according to the sleeve

diameter;:: Additional fixation of the surgical guide.

RegularNarrow Wide

125.130 125.132125.131

Guided Surgery Guide Stabilizers - Long

:: Available in titanium;:: Additional fixation of the surgical guide;:: To be used when the H11 sleeve height is

chosen.

RegularNarrow

125.133 125.134

Page 36: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

071070

Posterior Implant SolutionImmediate placement in challenging post extraction sockets;

Immediate implant placement with optimized wide implant design:

• Designed to achieve high primary stability in wide post extraction sockets;

• Grand Morse® Helix® – the Unbeatable Versatility.

Deliver natural-looking esthetics thanks to an optimized wide emergence profile design:

• A wide customizable healing abutment was designed to maintain the molar emergence profile;

• Consistent emergence profile for excellent esthetics outcomes.

Acqua

Ø 5.5

Ø 7.0

6.5 mm5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm

:: Use the manual Neo Screwdriver (104.060);:: Do not exceed the insertion torque of 10 N.cm.

Drill Sequence Helix GM® Ø 6.0

Helix GM® Ø 6.0 Implants

Bone types III and IV

Optional

103.170

Initial

103.170 103.170

Ø 2.0

103.425 103.170

Ø 3.5

103.399 103.170

Ø 3.75

103.402 103.170

Ø 4.3

103.408 103.170

Ø 5.0

103.411 103.170

Ø 6.0

103.427

GM Customizable Healing Abutment

106.223 106.224 106.225 106.226 106.227

Ø 5.5

2.5 mm1.5 mm0.8 mm

6 m

m

GH

GH

GH

135.290 135.291 135.292

4.5 mm3.5 mm

135.293 135.294

GM Titanium Base Burn-out Coping

GM Exact Titanium Base

Ø 5.5

6 mm4 mm

118.329 118.342

:: Use the Neo Screwdriver Torque Connection - Torque Wrench (105.132).

Ø 5.5

2.5 mm1.5 mm0.8 mm

4 m

m

135.284 135.285 135.286

4.5 mm3.5 mm

135.287 135.288

NeoPoros

8.0 mm

140.1009

109.1009

10.0 mm

140.1010

109.1010

11.5 mm

140.1011

109.1011

13.0 mm

140.1012

109.1012

20N.cm

106.228 106.229 106.230 106.231 106.232

Page 37: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

073072

Technique that allows passive fitting, with no need for welding as the titanium coping is cemented to the substructure.Used for multiple prostheses and reduces laboratory work times.

One Step Hybrid Technique

Neo Mini Conical Abutment One Step Hybrid Copings

Neo Micro Conical Abutment One Step Hybrid Copings

Neo Working Screw One Step Hybrid

:: For installation, use the Neo Torque Connection (105.132);

:: For torque control, use Torque Wrench (104.050).

:: For installation, use the Neo Torque Connection (105.132);

:: For torque control, use Torque Wrench (104.050).

:: For laboratory use.

Titanium

Titanium

Brass

Brass

Burn-out

Burn-out

118.340 118.331 118.330

118.341 118.333 118.332

116.271

Page 38: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

075074

Demonstration Sequence

Surgical drilling completed, obtaining adequate distance from distal implant in relation to the mental foramen with 7 mm Space PlanningInstrument.

Positioning of Multifunctional Guideto obtain intermaxillary correlation.Soft silicone is injected to take thesoft tissue impression.

Placement of correspondingNeodent® Abutments.

Working model with artificial gum.

Regularize the alveolar ridge.

Placement of ImpressionCopings, splinted with acrylicresin.

Burn-out One Step Hybrid Coping,Brass One Step Hybrid Coping,grooved Titanium One Step HybridCoping. The last one with lowerdimensions than the brass one, whichcompensates using the mill.

Placement of 4 Neodent® implants, according to their indication.

Removal of Multi-Funcional Guide and placement of Analogs to the impression copings.

Castable ring with waxed framework.Brass Copings are placed overanalogs, then Burn-out Copings arefixed by working screws.

Cementing with Panavia the structure over the titanium copings.

Please note cementing area.Place the framework over the stone model.

Cast framework.

Final inside-mouth view.

31 2

4 5 6

7 98

10 1211

1413 15

16

Page 39: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

077076

Technique used to ease mandible rehabilitation, through a provisional hybrid typeprostheses supported by implants.

Neo Distal Bar Coping

Neo Distal Bar

Polishing Protector

:: Available in titanium;:: Retainers to ease joining with acrylic resin;:: Recommended torque: 10 N.cm;:: For torque, use Neo Screwdriver (105.132)

:: Recommended for distal Implants to reinforce the cantilever.

:: Available in surgical steel;:: Protection for the lab polishing.

118.308

123.008

Distal Bar Technique

125.116

Prosthesis wearing, keeping posterior region integrity.

Neodent® Abutments placed.

Apply selfpolymerizing acrylic resin on and between the copings.

Placement of rubber dam over copings to protect soft tissues.

Adjustments, finishing and polishing procedures of inferior prosthesis with polishing protectors.

Remove the inferior prosthesis after resin is polymerized. Copings already captured.

Proof of inferior prostheses wearing (centered occlusion position, no interference on copings).

Place the copings into the central Implants and Distal Bar to distal Implants.

Apply to worn area in lower prosthesis, repositioning inside mouth. Keep patient in occlusion until total polymerization.

Final inside-mouth posterior view.

Placed provisional implant supported prosthesis.

Demonstration Sequence

6

7

9

11

8

10

5

1 2

43

Page 40: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

079078

Neodent® General Instruments

Neodent® Scanbodies can be used for scanning and digitalization of the patient or model providing accuracy in determining the analog position.

Scanbody

Neodent® Digital Libraries

Visit www.neodent.com/cadcam to download the digital files to work with Neodent® Titanium Bases,

Titanium Blocks, Abutments, Mini Conical Abutments, Micro Abutments, Universal Abutments, One Step Hybrid

Copings, Scanbodies and Hybrid Repositionable Analogs. Libraries are available for the following companies:

exocad GmbH, Amann Girrbach AG Inc, Dental Wings Inc and 3Shape A/S.

GM Exact Implant Intraoral Scanbody

GM Exact Implant Scanbody (for model)

GM Mini Conical Abutment Scanbody

GM Micro Abutment

GM Abutment

108.183

108.181

108.196

108.197

108.198

Hybrid Repositionable Analog

Neodent® Hybrid Repositionable Analogs can be used in prototyped models, produced by 3D printers, or conventional plaster models.

101.103

101.089

101.090

101.091

101.092

101.097

101.098

101.099

101.100

101.101

GM Hybrid Repositionable Analog 3.5/3.75

GM Hybrid Repositionable Analog 4.0/4.3

GM Hybrid Repositionable Analog 5.0/6.0

Micro Abutment Hybrid Repositionable Analog

Mini Conical Abutment Hybrid Repositionable Analog

Universal Abutment Hybrid Repositionable Analog 3.3X4

Universal Abutment Hybrid Repositionable Analog 3.3X6

Universal Abutment Hybrid Repositionable Analog 4.5X4

Universal Abutment Hybrid Repositionable Analog 4.5X6

GM Abutment Hybrid Repositionable Analog

Compatible with

Neo Screwdriver

Torque Wrench

:: Available in surgical steel;:: Extremely safe (lower than 5% variation);:: Fitting for square connections;:: Collapsible Wrench that allows for proper

assembly cleaning.

104.050

Operation Instructions

The Neodent® Torque Wrenchwas designed to allow thenecessary torque to be applied and simultaneous verification of that torque with the same Instrument.

The Neodent® Torque Wrench comes with pre-calibrated torques.

The wrench function works in both directions, by simply pulling and turning the driver’s pin 180°.However, the torque measurements work only lockwise.

All that is needed is to apply force to the wrench handle(never the wrench body) until the value marked on theLATERAL SCALE corresponds to the desired torque

•WARNING: When inverting the torque direction, the gear may come loose from the driver bodyand fall. Therefore, this inversion should only be done with the driver connected to a part oroutside the patient’s mouth.

1

2

Page 41: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

081080

Titanium Tweezers

:: To handle implants;:: New Tweezer system that

prevents deviation in the active bit;

:: Millimeter scale for checking during procedures;

:: Self-locking implant.

129.001

129.004

Depth Probe

:: Available in titanium;:: To probe preparations and analyze

depth;:: Millimeter scale for checking during

procedures.

:: Available in surgical steel;:: Recommended for prosthetic/

surgical planning.:: 7 and 9 mm marks.

7 and 9 mm Space Planning Instrument

128.026

124.001

124.003

Surgical Labial Retractor

Columbia Retractor

:: Available in surgical steel;:: Rounded edges to minimize surgical

trauma.

:: Available in surgical steel;:: Rounded edges to minimize surgical

trauma.

129.008

Scapel Handle

:: Available in surgical steel;:: For standard scalpel blade use;:: Blade not included.

Bivers Handle

:: Available in surgical steel;:: Non-traumatic extraction for

implant placement;:: Similar to a periotome.

129.002

Concave Osteotome

Convex Osteotome

Osteotomes Kit Case

:: Available in surgical steel;:: Concave active cutting bit for

nontraumatic lifting the floor of the maxillary sinus;

:: Used to prepare the surgical alveolus for Implant placement in the posterior maxillary region with low bone height;

:: Marks from 7 to 17mm.

:: Available in surgical steel;:: Convex active bit;:: Used when the bone width is

insufficient, demanding bone compression and expansion before placing the implant;

:: Marks from 7 to 17mm.

:: Available in polymer;:: Autoclavable;:: Osteotomes sold separately.

3.5 mm

3.5 mm

4.0 mm 4.5 mm3.0 mm

3.0 mm

2.5 mm

2.5 mm

1.8 mm

1.8 mm

110.155

110.161

110.154

110.160

110.156

110.162

110.157

110.163

110.262

110.158 110.15917 mm13 mm9 mm

15 mm11 mm7 mm

17 mm13 mm9 mm

15 mm11 mm7 mm

Page 42: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

083082

Surgical Hammer

:: Available in surgical steel;:: Polymer active bit;:: Used in compactors and

expanders;:: Weight: 130g.

126.001

Trephine Bur

:: Available in surgical steel;:: Collecting bone cylinder;:: Implant removal.

0.35 mm

Ø 5.0 Ø 8.0Ø 4.3Ø 4.1Ø 3.3

103.026103.051 103.087 103.027 103.028

Sinus Lift Curette

:: Available in surgical steel;:: Used to displace the Sinusal

Membrane.

1 3 4 5 7

126.008 126.009 126.011126.010 126.012

Complement Case

:: Available in autoclavable polymer;:: Used to organize drills and

auxilliary connections.

110.270

104.036

Analog Handle

:: Used for tightening analogs and milling prosthetic abutments.

Handle Implant Driver

:: Available in stainless steel;:: Manual implant placement.

104.047

Guide Pin

103.092 103.093

Prosthetic Surgical Guide

:: Available in titanium;:: Abutments to prepare the surgical guide;:: Prosthetic guide inner diameter 2 mm:: Heights 6 and 10 mm;:: Surgical Guide: package with 10 units (5 units of

10 mm and 5 units of 6 mm);:: Surgical Guide Pin: package with 5 units

Page 43: Implant - Schmidtdental. · 2019-10-03 · This provides greater accessibility of organic fluids to Acqua implant surface.(2) Constant evolution and safety guarantee. Based on the

A Straumann Group Brand

Znakomity marketing Neodent usprawni Twoją komunikację z pacjentami.

Odwiedź nową stronę dla pacjentów Neodent:

www.mojimplant.com.pl

Schmidtdental Szymanowskiego 2 80-280 Gdańsk

+48 58 341 45 79 [email protected] www.schmidt-dental.pl