indice - ft.agency
TRANSCRIPT
INDICEINDEX
&$3,72/2
&+$37(5�
3$5$*5�
3$5�
'(6&5,=,21(
'(6&5,37,21
3$*,1$
3$*(
1
2
3
4
5
6
7
8
9
10
11
1
1
1
2
1
2
1
2
1
1
1
1
1
2
3
4
1
2
- CARATTERISTICHE GENERALI
- CONDIZIONI DI IMPIEGO
- DISTRIBUTORI MONOBLOCCO "LT 25" a 1-2-3 leve
- DISTRIBUTORI MONOBLOCCO "LT 25" a 4-5-6 leve
- DISTRIBUTORI MONOBLOCCO "LT 30" a 1-2-3-4 leve
- DISTRIBUTORI MONOBLOCCO "LT 30" a 4-5-6-8 leve
- DISTRIBUTORI MONOBLOCCO "LT 60" a 1-2-3 leve
- DISTRIBUTORI MONOBLOCCO "LT 60" a 4-5-6 leve
- DISTRIBUTORE MONOBLOCCO "LT 140"
- DISTRIBUTORE COMPOSTO "LT 40/08" a 1-2-3-4-5-6-7-8-9-10 leve
- DISTRIBUTORE COMPOSTO "LT 50" a 1-2-3-4-5-6-7-8-9 leve
- DISTRIBUTORE COMPOSTO "LT 120" a 1-2-3-4-5-6-7 leve
- ACCESSORI PER DISTRIBUTORI MONOBLOCCO "LT 25 - 30 - 60"
- ACCESSORI PER DISTRIBUTORI MONOBLOCCO "LT 30 e LT 60"
- ACCESSORI PER DISTRIBUTORE MONOBLOCCO "LT 140"
- ACCESSORI PER DISTRIBUTORI COMPOSTI "LT 40/08-LT 50-LT 120"
- SCHEMI DEI CURSORI DISPONIBILI
- SCHEMI DEI TIPI DI AZIONAMENTO
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
16
17
18
DIRECTIONAL CONTROL VALVE "LT 60" with 1-2-3 levers
GENERAL FEATURES
CONDITIONS OF USE
ACCESSORIES FOR DIRECTIONAL CONTROL VALVES "LT 25 - 30 - 60"
DIRECTIONAL CONTROL VALVE "LT 120" with 1-2-3-4-5-6-7 levers
DIRECTIONAL CONTROL VALVE "LT 30" with 4-5-6-8 levers
DIRECTIONAL CONTROL VALVE "LT 25" with 1-2-3 levers
DIRECTIONAL CONTROL VALVE "LT 60" with 4-5-6 levers
DIRECTIONAL CONTROL VALVE "LT 40/08" with 1-2-3-4-5-6-7-8-9-10 levers
ACCESSORIES FOR DIRECTIONAL CONTROL VALVE "LT140"
ACCESSORIES FOR DIRECTIONAL CONTROL VALVES "LT 30 and LT 60"
LAYOUT OF AVAILABLE PILOT SHAFTS
ACCESSORIES FOR DIRECTIONAL CONTROL VALVES "LT 40/08-LT 50-LT 120"
DIAGRAMS OF OPERATION TYPES
DIRECTIONAL CONTROL VALVE "LT 140"
DIRECTIONAL CONTROL VALVE "LT 50" with 1-2-3-4-5-6-7-8-9 levers
DIRECTIONAL CONTROL VALVE "LT 25" with 4-5-6 levers
DIRECTIONAL CONTROL VALVE "LT 30" with 1-2-3-4 levers
DISTRIBUTORI - DIRECTIONAL CONTROL VALVES OMFB S.p.A.
134-01 Pag.1
CARATTERISTICHE GENERALI GENERAL FEATURES
DISTRIBUTORI MONOBLOCCODistributori per portate fino a 150 l/min e pressioni fino a 300 bar.I corpi sono in ghisa speciale ad alta resistenza. I cursori sono in acciaio al nichel cementati e temprati, a richiesta possono
essere forniti nichelati.Ogni gruppo è normalmente corredato di valvola generale di massima pressione in entrata, e di valvola di non-ritorno.L’alimentazione del distributore è standard a sinistra e, a richiesta, a destra.La distribuzione è normalmente in parallelo, ma su alcuni modelli è disponibile anche in serie.A richiesta sono disponibili valvole ausiliarie da flangiare sugli utilizzi (max. pressione, anti-urto, anti-cavitazione, di blocco
pilotate e rigeneratrici) e valvole complementari.Il comando cursore è normalmente manuale, a richiesta sono disponibili comandi pneumatici, elettro pneumatici, idraulici,
elettro-idraulici, elettrici, con cavi flessibili.
DISTRIBUTORI COMPONIBILIDistributori ad elementi componibili per portate fino a 220 l/min e pressioni fino a 300 bar.Gli elementi e le fiancate sono in ghisa speciale ad alta resistenza. I cursori sono in acciaio al carbonio nichelati.Ogni gruppo è corredato di valvola generale di massima pressione in entrata.Ogni elemento è dotato di valvola di non ritorno ed è predisposto per il montaggio di valvole ausiliarie (anti-urto, max.pressione
e anti-cavitazione). É possibile inoltre montare valvole di blocco pilotate flangiate sugli utilizzi.L’alimentazione del distributore è standard a sinistra e, a richiesta, a destra. La distribuzione può essere in parallelo, serie e
serie-parallelo.Il comando cursore è normalmente manuale, a richiesta sono disponibili comandi pneumatici, idraulici, elettrici, elettroidraulici,
con cavi flessibili.Sono disponibili elementi intermedi speciali con valvola di max.pressione, valvola prioritaria, valvola di esclusione, divisori di
portata con regolatore, collettori di scarico.
Il nostro Servizio Tecnico Commerciale è a completa disposizione per qualsiasi ulteriore chiarimento circa le applicazioni diquesto prodotto. (Tel. 030-9823612 - Fax. 030-983825)
SINGLE DIRECTIONAL CONTROL VALVESDirectional control valves for flows up to 150 l/min and pressures up to 300 bar.The valve bodies are in special high strength cast iron. The pilot shafts are in casehardened and tempered nickel steel. Nickel-plated steel
can be supplied on request.Each unit is generally supplied with a maximum pressure valve at the inlet and a non-return valve.The directional control valve is supplied with a left hand feed as standard; right hand feed can be supplied on request.Distribution is generally in parallel, though series distribution is available on some models.Auxiliary valves for flange fitting to the service ports (max. pressure, shockproof, anti-cavitation, piloted block valves and recovery valves)
and supplementary valves are available on request.Pilot shaft control is normally manual, though pneumatic, electro-pneumatic, hydraulic, electro-hydraulic and electric controlled levers with
flexible cables are available on request.
MULTIPLE DIRECTIONAL CONTROL VALVESMultiple directional control valves for flows up to 220 l/min and pressures up to 300 bar.Bodies and side elements are in special high strength cast iron. Control levers are in nickel plated carbon steel.Each group is equipped with a main max. inlet pressure valve.Each single unit is fitted with a non-return valve and is designed to accept auxiliary valves (shockproof, max. pressure and anti-cavitation).
Piloted block valves with flange fitting to the service ports can also be mounted.The directional control valve is supplied with a left hand feed as standard; right hand feed can be supplied on request.Distribution can be parallel, series or series-parallel.Pilot shaft control is normally manual, though pneumatic, hydraulic, electric and electro-hydraulic controlled levers with flexible cables are
available on request.Special intermediate elements are also available: max. pressure valve, priority valve, stop valves, flow distribution valves with regulator,
tank outlet manifolds.
Our Technical Sales Department is available for any further clarification regarding the applications of this product (Tel. 030-9823612 - Fax030-983825).
OMFB S.p.A. DISTRIBUTORI - DIRECTIONAL CONTROL VALVES
Pag.2 134-01
CONDIZIONI DI IMPIEGOCONDITIONS OF USE
Etere dell’acido fosforicoPhosphoric acid ether
Temperatura ambientale : da -40 a + 100 °C Viscosità cinematica : da 10 a 500 mm 2/s Ambient temperature : from -40 to +100C Kinematic viscosity : from 10 to 500 mm2/s
Fluido idraulico : consultare tabella Contaminazione ammessa : 29/18 (ISO/DIS 4406)Hydraulic fluid : see table Allowed contamination : 29/18 (ISO/DIS 4406)
FPM**
Miscele di etere e idrocarburi - Mixture of ether and hydrocarbons
Soluzioni acquose a base di poliglicoli (40%-60% di acqua)Polyglycol based aqueous solution (40%-60% water)
Acqua con olio (emulsione con max. 20% di componenti infiammabili)Water with oil (emulsion with max. 20% flammable components)
Olio con acqua (emulsione con max. 60% di componenti infiammabili)Oil with water (emulsion with max. 60% flammable components)
Olio minerale HLP secondo DIN 51524 e 51525HLP mineral oil according to DIN 51524 and 51525
Idrocarburi clorurati (Benzene, Clorobenzene)Chlorinated hydrocarbons
CAMPO DI TEMPERATURA
DEL FLUIDO (°C) FLUID TEMPERATURE RANGE (C)
GUARNIZIONI - GASKETS
NBR*
FLUIDO - FLUID
•
•
•
•
••
•
•
- 20 + 100
+ 5 + 55
+ 5 + 60
- 20 + 65
- 15 + 100
- 20 + 80
* NBR Elastomero in gomma nitrilica resistente ad oli minerali e grassi.
** FPM Elastomero fluorurato (VITON) resistente al calore ed agli altri agenti chimici.* NBR Elastomer in mineral oil-resistent and grease-resistent nitrile rubber ad oli minerali e grassi.
** FPM Fluorinated heat-resistent and chemical resistent elastomer (VITON).
Dimensioni Generali Filettature - Thread dimensions
METRICA (ISO 6149)Filettatura ciloindrica a tenuta con O-Ring
Parallel thread with O-Ring seal
BSP (ISO 228)Filettatura cilindrica a tenuta con rondella
Parallel thread with washer seal
NPT (ANSI.B1.20.1)Filettatura conica a tenuta tra i filetti
Taper thread self-sealing
SAE UN-UNF (ISO 725)Filettatura cilindrica a tenuta con O-Ring
Parallel thread with O-Ring seal
METRICA (ISO 262)Filettatura cilindrica a tenuta con rondella
P arallel thread with washer seal
SAE
23,9
A
DimensioniDimensions
20,6
B (min)
C
E
M 22 X 1,5 M 27 X 2 M 33 X 2M 18 X 1,5
METRICA - METRIC
ISO 6149
DimensioniDimensions ISO 262
15 °12 °
1" 7/8-12 UNSAE24
1" 5/8-12 UNSAE20
BSP
16
DimensioniDimensions
14
2723
G 1/2G 3/8
NPT
8,1
DimensioniDimensions
6,1
21,217,0
NPT 1 1/2-11,5NPT 1 1/4-11,5
2015
3430
2,52,5
16
34
23,8
2,4
ISO 6149ISO 262 ISO 6149ISO 262ISO 6149ISO 262
16
31,5
19
40
29,4
3,1
18
37,7
19
46
35,4
3,1
20
45
14,5
29
19,8
2,4
14
27,5
A
B (max)
A
B
C
D
A
B
D
G 1G 3/4 G 1 1/2G 1 1/4G 1/4G 1/8
2018
4033
10,18,6
33,226,5
2422
5650
10,710,7
48,041,9
1410
1915
5,84,1
13,610,2
NPT 1-11,5NPT 3/4-14NPT 1/2-14NPT 3/8-18NPT 1/4-18NPT 1/8-27
15,612,4
1" 5/16-12 UNSAE16
1" 1/16-12 UNSAE12
1312
2521
2,52,4
7/8-14 UNFSAE10
3/4-16 UNFSAE8
9/16-18 UNFSAE6
7/16-20 UNFSAE4
17 20 20 20
41
29,2
3,3
49
35,5
3,3
58
43,5
3,3
65
49,5
3,3
DISTRIBUTORI - DIRECTIONAL CONTROL VALVES OMFB S.p.A.
134-02 Pag.3
Distributori Monoblocco "LT 25" a 1-2-3 leveDirectional Control Valves "LT 25" with 1-2-3 levers
Regolazione Pres.max.Relief valve adjustament
Scarico - Tank-outlet
Con microinterruttoreWith microswitch
Tappo valvola controllo caricoLoad control valve plug
Utilizzi - Service Ports
FILETTATURE DISPONIBILIAVAILABLE THREAD
Pressione - Pressure
3,2
134.3.10029
134.3.21
134.3.10038
134.3.30
134.3.10010
DESCRIZIONEDESCRIPTION
1/2"BSP
SIMBOLOSYMBOL
PESOWEIGHT
Kg.
134.3.12
3/8"BSP
PRESSIONEPRESSURE
bar
S
1,3
A - B
4,8
R
3,4
V
5
+ MCR
1,1
P
SP - A - B
PORTATADELIVERY
lt / min.
124
88
160
124
160
88
DIMENSIONI IN mmDIMENSION
LF
25025
CODICE DI
ORDINAZIONEORDER CODE
SCHEMA LT 25 - 3 LeveLAYOUT 3 Lever - LT 25
117
81
153
117
153
81
LT 25 - 2 Leve + MCR
LT 25 - 2 Leve - Lever
LT 25 - 3 Leve + MCR
LT 25 - 3 Leve - Lever
LT 25 - 1 Leva + MCR
LT 25 - 1 Leva - Lever
TIPOTYPE
SCHEMA LT 25 - 1 LevaLAYOUT 1 Lever - LT 25
SCHEMA LT 25 - 2 LeveLAYOUT 2 Lever - LT 25
OMFB S.p.A. DISTRIBUTORI - DIRECTIONAL CONTROL VALVES
Pag.4 134-03
Regolazione Pres.max.Relief valve adjustament
Scarico - Tank-outlet
Tappo valvola controllo caricoLoad control valve plug
Utilizzi - Service Ports
FILETTATURE DISPONIB.AVAILABLE THREAD
Pressione - Pressure
6,9
134.3.10056
134.3.58
134.3.10065
134.3.67
134.3.100471/2"BSP
PESOWEIGHT
Kg.
134.3.49
3/8"BSP
PRESSIONEPRESSURE
bar
S
6,2
A - B
8
R
7,1
V
8,2
6
P
SP - A - B
PORTATADELIVERY
lt / min.
229
193
265
229
265
193
DIMENSIONIin mm
DIMENSION
LF
25025
CODICE DI
ORDINAZIONEORDER CODE
SCHEMA LT 25 - 6 LeveLAYOUT 6 Lever - LT 25
222
186
258
222
258
186
LT 25 - 5 Leve + MCR
LT 25 - 5 Leve - Lever
LT 25 - 6 Leve + MCR
LT 25 - 6 Leve-Lever
LT 25 - 4 Leve + MCR
LT 25 - 4 Leve - Lever
TIPOTYPE
SCHEMA LT 25 - 4 LeveLAYOUT 4 Lever - LT 25
SCHEMA LT 25 - 5 LeveLAYOUT 5 Lever - LT 25
Distributori Monoblocco "LT 25" a 4-5-6 leveDirectional Control Valves "LT 25" with 4-5-6 levers
Con microinterruttoreWith microswitch
+ MCR
DESCRIZIONEDESCRIPTION
SIMBOLOSYMBOL
DISTRIBUTORI - DIRECTIONAL CONTROL VALVES OMFB S.p.A.
134-03 Pag.5
Distributori Monoblocco "LT 30" a 1-2-3-4 leveDirectional Control Valves "LT 30" with 1-2-3-4 levers
Regolazione Pres.max.Relief valve adjustament
Scarico - Tank-outlet
Con microinterruttoreWith microswitch
Tappo valvola controllo caricoLoad control valve plug
LT 30 - 4 Leve + MCR
LT 30 - 4 Leve - Lever
Utilizzi - Service Ports
FILETTATURE DISPONIBILIAVAILABLE THREAD
Pressione - Pressure
4,8
134.1.201
134.1.194
134.1.238
134.1.229
134.1.265
134.1.256
134.1.176
DESCRIZIONEDESCRIPTION
1/2"BSP
SIMBOLOSYMBOL
PESOWEIGHT
Kg.
134.1.103
3/8"BSP
PRESSIONEPRESSURE
bar
S
3,6
A - B
6,4
R
5,0
V
7,8189
6,6
+ MCR
8,0189
3,4
P
SP - A - B
PORTATADELIVERY
lt / min.
139
104
174
139
209
174
209
104
DIMENSIONI IN mmDIMENSION
GF
25030
CODICE DI
ORDINAZIONEORDER CODE
SCHEMA LT 30 - 3 LeveLAYOUT 3 Lever - LT 30
119
84
154
119
154
84
LT 30 - 2 Leve + MCR
LT 30 - 2 Leve - Lever
LT 30 - 3 Leve + MCR
LT 30 - 3 Leve - Lever
LT 30 - 1 Leva + MCR
LT 30 - 1 Leva - Lever
TIPOTYPE
SCHEMA LT 30 - 1 LevaLAYOUT 1 Lever - LT 30
SCHEMA LT 30 - 4 LeveLAYOUT 4 Lever - LT 30
SCHEMA LT 30 - 2 LeveLAYOUT 2 Lever - LT 30
OMFB S.p.A. DISTRIBUTORI - DIRECTIONAL CONTROL VALVES
Pag.6 134-04
Regolazione Pres.max.Relief valve adjustament
Scarico - Tank-outletCon Elemento IntermedioWith intermediate section
Tappo valvola controllo caricoLoad control valve plug
LT 30-8 Leve +Elm.Int +Mcr
LT 30-8 Leve-Lever +Elm.Int
Utilizzi - Service Ports
FILETTATURE DISPONIB.AVAILABLE THREAD
Pressione - Pressure
12,4
134.1.318
134.1.309
134.1.345
134.1.336
134.1.407
134.1.390
134.1.283
DESCRIZIONEDESCRIPTION
1/2"BSP
SIMBOLOSYMBOL
PESOWEIGHT
Kg.
134.1.274
3/8"BSP
PRESSIONEPRESSURE
bar
S
A - B
14,2
R
V
17,8356
+ ELM.INT
356
10,6
P
SP - A - B
PORTATADELIVERY
lt / min.
295
260
330
295
400
330
400
260
DIMENSIONIin mm
DIMENSION
LF
25030
CODICE DI
ORDINAZIONEORDER CODE
SCHEMA LT 30 - 6 LeveLAYOUT 6 Lever - LT 30
251
216
286
251
286
216
LT 30-5 Leve +Elm.Int +Mcr
LT 30-5 Leve-Lever +Elm.Int
LT 30-6 Leve +Elm.Int +Mcr
LT 30-6 Leve-Lever +Elm.Int
LT 30-4 Leve +Elm.Int +Mcr
LT 30-4 Leve-Lever +Elm.Int
TIPOTYPE
SCHEMA LT 30 - 4 LeveLAYOUT 4 Lever - LT 30
SCHEMA LT 30 - 8 LeveLAYOUT 8 Lever - LT 30
SCHEMA LT 30 - 5 LeveLAYOUT 5 Lever - LT 30
Distributori Monoblocco "LT 30" a 4-5-6-8 leveDirectional Control Valves "LT 30" with 4-5-6-8 levers
G
273
238
308
273
378
308
378
238
Con microinterruttoreWith microswitch
+ MCR
DESCRIZIONEDESCRIPTION
SIMBOLOSYMBOL
DISTRIBUTORI - DIRECTIONAL CONTROL VALVES OMFB S.p.A.
134-04 Pag.7
Distributori Monoblocco "LT 60" a 1-2-3 leveDirectional Control Valves "LT 60" with 1-2-3 levers
Regolazione Pres.max.Relief valve adjustament
Scarico - Tank-outlet
Tappo vlv controllo carico colleg.in serieLoad control valve plug connected in series
Tappo valvola controllo caricoLoad control valve plug
Utilizzi - Service Ports
FILETTATURE DISPONIBILIAVAILABLE THREAD
Pressione - Pressure
12,2134.15.63
134.15.45
DESCRIZIONEDESCRIPTION
3/4"BSP
SIMBOLOSYMBOL
PESOWEIGHT
Kg.
134.15.271/2"BSP
PRESSIONEPRESSURE
bar
S
9,3
A - B
R
V
Q
6,4
P
SP - A - B
PORTATADELIVERY
lt / min.
220
175
130
DIMENSIONI IN mmDIMENSION
GF
25060
CODICE DI
ORDINAZIONEORDER CODE
SCHEMA LT 60 - 2 LeveLAYOUT 2 Lever - LT 60
196
151
106
LT 60 - 3 Leve - Lever
LT 60 - 1 Leve - Lever
TIPOTYPE
SCHEMA LT 60 - 3 LeveLAYOUT 3 Lever - LT 60
SCHEMA LT 60 - 1 LeverLAYOUT 1 Lever - LT 60
LT 60 - 2 Leve - Lever
OMFB S.p.A. DISTRIBUTORI - DIRECTIONAL CONTROL VALVES
Pag.8 134-05
Regolazione Pres.max.Relief valve adjustament
Scarico - Tank-outlet
Tappo valvola controllo caricoLoad control valve plug
Utilizzi - Service Ports
FILETTATURE DISPONIB.AVAILABLE THREAD
Pressione - Pressure
22,5134.15.125
134.15.107
DESCRIZIONEDESCRIPTION
3/4"BSP
SIMBOLOSYMBOL
PESOWEIGHT
Kg.
134.15.811/2"BSP
PRESSIONEPRESSURE
bar
S
20
A - B
R
V
17,5
P
SP - A - B
PORTATADELIVERY
lt / min.
369
324
279
DIMENSIONI in mmDIMENSION
HF
25060
CODICE DI
ORDINAZIONEORDER CODE
363
318
273
LT 60 - 6 Leve-Lever
LT 60 - 5 Leve-Lever
LT 60 - 4 Leve-Lever
TIPOTYPE
SCHEMA LT 60 - 4 LeveLAYOUT 4 Lever - LT 60
SCHEMA LT 60 - 6 LeveLAYOUT 6 Lever - LT 60
Distributori Monoblocco "LT 60" a 4-5-6 leveDirectional Control Valves "LT 60" with 4-5-6 levers
G
391
346
301
Tappo vlv controllo carico colleg.in serieLoad control valve plug connected in series
Q
SCHEMA LT 60 - 5 LeveLAYOUT 5 Lever - LT 60
DISTRIBUTORI - DIRECTIONAL CONTROL VALVES OMFB S.p.A.
134-05 Pag.9
Distributore Monoblocco "LT 140"Directional Control Valve "LT 140"
134.17.25
PESOWEIGHT
Kg.
134.17.16
PRESSIONEPRESSURE
bar
8,2
8,2
PORTATADELIVERY
lt / min.
180100
CODICE DI
ORDINAZIONEORDER CODE
LT 140
TIPOTYPE
LT 140 - Stelo CromatoLT 140 - Chromed steam
OMFB S.p.A. DISTRIBUTORI - DIRECTIONAL CONTROL VALVES
Pag.10 134-06
Gli attacchi A e B sono da 3/8" e su richiesta si possono fornire da 1/2".Connections A and B are 3/8" BSP. 1/2" BSP is available on request
Scarico - Tank-outlet
Valvola Regolazione press. max.Relief valve adjustement
Utilizzi - Service Ports
Pressione - Pressure
12134.21.65
134.21.56
NOTENOTES
FILETTATURATHREAD
PESOWEIGHT
Kg.
134.21.47
PRESSIONEPRESSURE
bar
3/8" BSP
10,5
1/2" BSP
3/8" BSP
9
1/2" BSP
PORTATADELIVERY
lt / min.
288
252
216
DIMENSIONI in mmDIMENSION
LF
28040
CODICE DI
ORDINAZIONEORDER CODE
257
221
185
LT 40/08 -5 Leve-Lever
LT 40/08 -4 Leve-Lever
LT 40/08 -1 Leva-Lever
TIPOTYPE
Distributore Composto "LT 40/08" a 1-2-3-4-5-6-7-8-9-10 leveDirectional Control Valves "LT 40/08" with 1-2-3-4-5-6-7-8-9-10 levers
G
263
227
191
LT 40/08 -7 Leve-Lever
LT 40/08 -6 Leve-Lever
LT 40/08 -9 Leve-Lever
LT 40/08 -8 Leve-Lever
LT 40/08 -3 Leve-Lever
LT 40/08-10 Leve-Lever
LT 40/08 -2 Leve-Lever
134.21.92
134.21.83
134.21.74
134.21.38
134.21.29
134.21.109
134.21.10
16,5
15
13,5
396
360
324
365
329
293
371
335
299
7,5
6
18
180
144
432
149
113
401
155
119
407
4,510877 83
ATTACCOCONNECTION
A
T
V
B
P
Utilizzi - Service Ports
DESCRIZIONEDESCRIPTION
Gli attacchi P e T sono tutti da 1/2" - Su richiesta si possono avere da 3/8"Connections P and T are all 1/2" BSP. 3/8" BSP is available on request
DISTRIBUTOR - DIRECTIONAL CONTROL VALVES OMFB S.p.A.
134-07 Pag.11
Scarico - Tank-outlet
Valvola Regolazione press. max.Relief valve adjustement
Utilizzi - Service Ports
Pressione - Pressure
24,2134.19.69
134.19.50
FILETTATURATHREAD
PESOWEIGHT
Kg.
134.19.41
PRESSIONEPRESSURE
bar
3/4" BSP
3/4" BSP
3/4" BSP
0,3
3/4" BSP
PORTATADELIVERY
lt / min.
DIMENSIONI in mmDIMENSION
F
25050
CODICE DI
ORDINAZIONEORDER CODE
312,5
37
LT 50 - 5 Leve - Lever
LT 50 - 4 Leve - Lever
LT 50 - 1 Leva - Lever
TIPOTYPE
Distributore Composto "LT 50" a 1-2-3-4-5-6-7-8-9 leveDirectional Control Valves "LT 50" with 1-2-3-4-5-6-7-8-9 levers
G
350
1
LT 50 - 7 Leve - Lever
LT 50 - 6 Leve - Lever
LT 50 - 9 Leve - Lever
LT 50 - 8 Leve - Lever
LT 50 - 3 Leve - Lever
LT 50 - 2 Leve - Lever
134.19.86
134.19.87
134.19.78
134.19.32
134.19.23
134.19.14
33,5
30,4
27,3
438,5
396,5
354,5
476
434
392
0,8
1
50
62
1,3
1,8
1,370 2,2
ATTACCOCONNECTION
T4
T3
T1
B
T2
Utilizzi - Service Ports
SOLO ELEMENTOSection only
V
P1
P
A 1/2" BSP
1/2" BSP
1/2" BSP
1/2" BSP Pressione - Pressure
Scarico - Tank-outlet
Scarico - Tank-outlet
Scarico - Tank-outlet
DESCRIZIONEDESCRIPTION
PERDITE DI CARICO - HEAD LOSS
PORTATAFlow
COMPLETO 1 LEVA1 unit complete
barlt / min.
bar
21,1
18
270,5
228,5
308
266
14,9
11,8
186,5
144,5
224
182
8,7102,5 140
OMFB S.p.A. DISTRIBUTORI - DIRECTIONAL CONTROL VALVES
Pag.12 134-08
Scarico - Tank-outlet
Tappo Valvola Controllo CaricoLoad control valve plug
Utilizzi - Service Ports
Pressione - Pressure
39,6134.23.63
134.23.54
FILETTATURATHREAD
PESOWEIGHT
Kg.
134.23.45
PRESSIONEPRESSURE
bar
3/4" BSP
34,4
3/4" BSP
3/4" BSP
29,2
3/4" BSP
PORTATADELIVERY
lt / min.
DIMENSIONI in mmDIMENSION
F
250120
CODICE DI
ORDINAZIONEORDER CODE
428
376
324
LT 120 - 5 Leve - Lever
LT 120 - 4 Leve - Lever
LT 120 - 1 Leva - Lever
TIPOTYPE
Distributore Composto "LT 120" a 1-2-3-4-5-6-7 leveDirectional Control Valves "LT 120" at 1-2-3-4-5-6-7 levers
G
446
394
342
LT 120 - 7 Leve - Lever
LT 120 - 6 Leve - Lever
LT 120 - 3 Leve - Lever
LT 120 - 2 Leve - Lever
134.23.72
134.23.36
134.23.27
134.23.18
44,8480 498
24
18,8
272
220
290
238
13,6168 186
ATTACCOCONNECTION
A
S
R
B
P
Utilizzi - Service Ports
DESCRIZIONEDESCRIPTION
Tappo valvola anticavitazioneSuction valve plug
M
Valvola Regolazione press. max.Relief valve adjustement
V
DISTRIBUTORI - DIRECTIONAL CONTROL VALVES OMFB S.p.A.
134-09 Pag.13
VERSIONEVERSION
CODICE DI ORDINAZIONEORDER CODE
ACCESSORI PER DISTRIBUTORI MONOBLOCCO "LT 25 - 30 - 60"ACCESSORIES FOR DIRECTIONAL CONTROL VALVES "LT 25 - 30 - 60"
L
DESCRIZIONEDESCRIPTION
Tappo "Doppio scarico" per LT 60Double outlet plug for LT 60
Tappo "Centro chiuso" per LT 60Center closed plug for LT 60
134.16.213
134.16.62
42
62
H
D
LCODICE DI ORDINAZIONEORDER CODE
DATI TECNICI CAVO - TECHNICAL FEATURES OF CABLE
250 mm
700 N.
134.2.111
134.2.120 200
300
ACODICE DI ORDINAZIONEORDER CODE
DESCRIZIONEDESCRIPTION
Gruppo Scatto-molla per LT 30Spring release lock for LT 30
Gruppo scatto-molla per LT 60Spring release lock for LT 60
134.16.179
134.2.362 27
30
134.2.344
134.4.11 Tappo "Doppio scarico" per LT 25Double outlet plug for LT 25
Tappo "Centro chiuso" per LT 30Center closed plug for LT 30
H
D
ACODICE DI ORDINAZIONEORDER CODE
LDESCRIZIONEDESCRIPTION
Scatto per ogni leva per LT 25Lock for each lever for LT 25
Scatto per ogni leva per LT 60Lock for each lever for LT 60
134.16.17
134.4.20 33
53
27
30
cm
DESCRIZIONEDESCRIPTION
800 N.
- 30 °C + 80 °C
Telecomando completo cm.200Complete remote control. cm 200
Telecomando completo cm.300Complete remote control. cm 300
RAGGIO MINIMO DI CURVATURAMINIMUM RADIUS
CARICO DI COMPRESSIONECOMPRESSION LOAD
CARICO DI TRAZIONETENSILE LOAD
TEMPERATURA DI ESERCIZIOWORKING TEMPERATURE
134.2.237 Tappo "Doppio scarico" per LT 30Double outlet plug for LT 30
H
TELECOMANDO PER DISTRIBUTORI MONOBLOCCO "LT 30"REMOTE CONTROL FOR DIRECTIONAL CONTROL VALVES "LT 30"
Scatto per ogni leva per LT 30Lock for each lever for LT 30
134.2.68 3327
VERSIONENORMALENORMAL
VERSIONED
Centro chiusoCenter closed
VERSIONEH
CARRY-OVER
OMFB S.p.A. DISTRIBUTORI - DIRECTIONAL CONTROL VALVES
Pag.14 134-10
ESEMPI APPLICATIVI SERVOCOMANDO ELETTRICOEXAMPLES OF ELECTRIC SERVO-CONTROL APPLICATIONS
Servocomando elettrico x LT 60Electric servo control for LT 60
116,5
ACCESSORI PER DISTRIBUTORI MONOBLOCCO "LT 30 E LT 60"ACCESSORIES FOR DIRECTIONAL CONTROL VALVES "LT 30 AND LT 60"
CODICE DI ORDINAZIONEORDER CODE
B
Servocomando elettrico x LT 30Electric servo control for LT 30
95
CODICE DI ORDINAZIONEORDER CODE
DESCRIZIONEDESCRIPTION
Servocomando aria per LT 30Air servo control for LT 30
Servocomando aria per LT 60Air servo control for LT 60
134.16.35134.2.95
CODICE DI ORDINAZIONEORDER CODE
DESCRIZIONEDESCRIPTION
GRUPPO VALVOLA DIREZIONALE CON SERVOCOMANDOELETTRO-OLEODINAMICO E GRUPPO DI ALIMENTAZIONE IN SCARICO
DIRECTIONAL CONTROL VALVES WITH ELECTRO-HYDRAULIC SERVO CONTROL
AND OUTLET FEED UNITS
C D EA
134.16.197
134.2.380
171
155,5
40
34
102,5
96,5
49,5
44
DESCRIZIONEDESCRIPTION
SCHEMA COLLEGAMENTO ELETTRICOWIRING DIAGRAM
GRUPPO VALVOLA DIREZIONALE CON SERVOCOMANDO ELETTRO-OLEODINAMICO E GRUPPO DI ALIMENTAZIONE IN ENTRATA
DIRECTIONAL CONTROL VALVES WITH ELECTRO-HYDRAULIC SERVO CONTROL
AND INLET FEED UNITS
FUSIBILE 5A 12CCFUSIBILE 2,5A 24CC
BATTERIA
SPRING-LOADED BUTTON
- 2A COIL
FOR EACH ADDITIONAL SECTION
- BATTERY
12VDC 5A FUSE 24VDC 2.5A FUSE
TASTO A MOLLA
- 1A COILBOBINA 1A
BOBINA 2A
PER OGNI ELEMENTO AGGIUNTIVO -
ENTRATA - INLET SCARICO - OUTLET
PRESSURE REDUCER VALVE SET AT 15-18 BAR FIXED RIDUTTORE DI PRESSIONE TARATO A 15/18 BAR
PILOT PRESSUREPRESSIONE PILOTA
DRAINSPURGO
If you have pressure on returnline you must connected line 3seapratly to the tank
ENT
2 = TUBAZIONE DI PILOTAGGIO - PILOT PRESSURE LINE3= TUBAZIONE DI DRENAGGIO - DRAIN LINE
VALVOLA DI CONTROPRESSIONETARATA A 15/18 BARBACK-PRESSURE VALVES SETTEDAT 15-18 BAR
DISTRIBUTORI - DIRECTIONAL CONTROL VALVES OMFB S.p.A.
134-10 Pag.15
VERSIONEVERSION
CODICE DI ORDINAZIONEORDER CODE
ACCESSORI PER DISTRIBUTORI COMPOSTI LT40/08-LT50-LT120ACCESSORIES FOR DIRECTIONAL CONTROL VALVES LT40/08-LT50-LT120
DESCRIZIONEDESCRIPTION
CODICE DI ORDINAZIONEORDER CODE
DESCRIZIONEDESCRIPTION
Scatto per ogni leva per LT 120Lock for each lever for LT 120
134.20.17
134.22.46 Tappi di conversione da normale aVERSIONE "H" per LT 40/08Coversion plugs from normal to VER-SION "H" for LT 40/08
H
CODICE DI ORDINAZIONEORDER CODE
DESCRIZIONEDESCRIPTION
Scatto per ogni leva per LT 50Lock for each lever for LT 50
Scatto per ogni leva per LT 40/08Lock for each lever for LT 40/08
134.22.108
134.20.164
Outlet cover LT 40/08 CARRY-OVERtype with ports T1 and T3 for pressu-re connection and port T2 for tankconnection. Close T2 when using thetank port on the inlet cover. All theplugs shown are supplied as stand-ard.
OUTLET COVER WITH SPECIALPLUGS FOR CARRY-OVER VER-SION. TO OBTAIN A CLOSED CLO-SED CENTER, SHUT-OFF PORT T3WITH A 1/2 BSP PLUG.
Sezione di fiancata di scarico LT40/08 tipo CARRY-OVER con usci-te T1 e T3 per collegamento inpressione a seguire e uscita T2 dacollegare al serbatoio.Chiudere T2in caso si utilizzi l’attacco sulla te-stata di entrata. Tutti i tappi raffigu-rati sono forniti di serie.
SCHEMA MONTAGGIO FIANCATASCARICO CON TAPPI PER CARRYOVER. PER OTTENERE IL CEN-TRO CHIUSO É SUFFICIENTECHIUDERE L’ATTACCO T3 CONUN TAPPO DA 1/2 BSP
VERSIONENORMALENORMAL
VERSIONEH
CARRY-OVER
ACCESSORI PER DISTRIBUTORE MONOBLOCCO "LT 140"ACCESSORIES FOR DIRECTIONAL CONTROL VALVES "LT 140"
CODICE DI ORDINAZIONEORDER CODE
DESCRIZIONEDESCRIPTION
Servocomando ariaAir servo control
134.18.42
CODICE DI ORDINAZIONEORDER CODE
DESCRIZIONEDESCRIPTION
Scatti per levaLock for lever
134.18.15
OMFB S.p.A. DISTRIBUTORI - DIRECTIONAL CONTROL VALVES
Pag.16 134-10
SCHEMI DEI CURSORI DISPONIBILI LAYOUTS OF AVAILABLE PILOT SHAFTS
SIGLACODE
CARATTERISTICHEFEATURES
Cursore a centro chiuso. In posi-zione centrale utilizzo A a scarico.Utilizzo B chiuso. A leva spintaP → A, B → S. A leva tirata P → B,A → S. Ottenibile anche montandosullo scarico il tappo -D- con cur-sore tipo -B-.Centre pilot shaft closed in central po-sition. Service port A in discharge.Service port B closed.with lever pushed P → A, B → S, withlever pulled P → B, A → S.Also obtainable by mounting plug -D-on outlet with type -B- pilot
O
SCHEMALAYOUT
SIGLACODE
CARATTERISTICHEFEATURES
SCHEMALAYOUT
N
Cursore a centro chiuso. In posi-zione centrale utilizzo B allo scari-co. Utilizzo A chiuso. A leva spintaP → A, B → S. A leva tirata P → B,A → S. Ottenibile anche montandosullo scarico il tappo -D- con cur-sore tipo -I-.Centre pilot shaft closed in central po-sition. Service port B in discharge.Service port A closed.with lever pushed P → A, B → S, withlever pulled P → B, A → S.Also obtainable by mounting plug -D-on outlet with type -I- pilot
Cursore a centro aperto per cilin-dri a semplice effetto o motori uni-direzionali, in posizione centraleutilizzo A, a scarico a leva spintaP → A.Centre pilot shaft open in central posi-tion for single-acting cylinders or uni-directional motors. Service port A indischarge, with lever pushed P → A.
Q
P
Cursore a centro aperto per cilin-dri a semplice effetto o motori uni-direzionali, in posizione centraleutilizzo B a scarico. A leva tirataP → B.Centre pilot shaft open in central posi-tion for single-acting cylinders or uni-directional motors. Service port B indischarge, with lever pulled P → B.
Cursore a centro aperto (P → S) inposizione centrale. Utilizzo A chiu-so. Utilizzo B a scarico. A leva spin-ta P → A, B → S. A leva tirata P →B, A → S.Centre pilot shaft open (P → S) incentral position. Service port A clo-sed, Service port B in discharge.with lever pushed P → A, B → Swith lever pulled P → B, A → S
I
Cursore a centro aperto (P → S) inposizione centrale. Utilizzi chiusi.A leva spinta P → A, B → S. A leva tirata P → B, A → S.Centre pilot shaft open (P → S) incentral position. Service ports closed.with lever pushed P → A, B → Swith lever pulled P → B, A → S
Cursore a centro chiuso in posizio-ne centrale. Utilizzi allo scarico. Aleva spinta P → A, B → S. A leva ti-rata P → B, A → S. Ottenibile an-che montando sullo scarico iltappo -D- con cursore tipo -C-.Centre pilot shaft closed in central po-sition. Service ports in discharge.with lever pushed P → A, B → S withlever pulled P → B, A → S.Also obtainable by mounting plug -D-on outlet with type -C- pilot
M
A
Cursore a centro aperto (P → S) inposizione centrale. Utilizzo B chiu-so, utilizzo A allo scarico. A levaspinta P → S, B → S a leva tirataP → B, A → S.Centre pilot shaft open (P → S) incentral position. Service port B clo-sed, service port A in discharge.with lever pushed P → S, B → Swith lever pulled P → B, A → S
B
D
Cursore a centro chiuso (P →) inposizione centrale. Utilizzi chiusi.A leva spinta P → A, B → S. A levatirata P → B, A → S. Ottenibile an-che montando sullo scarico il tap-po -D- (Vedi pag.14).Centre pilot shaft closed (P → S) incentral position. Service ports closed.with lever pushed P → A, B → S, withlever pulled P → B, A → S. Also obtai-nable by mounting plug -D- on outlet(see page 14)
Cursore a centro aperto (P → S) inposizione centrale per cilindri asemplice effetto. Utilizzo chiuso. Aleva spinta P → A, a leva tirataP-A → S.Centre pilot shaft open (P → S) incentral position for single-acting cylin-ders. Service port closed.with lever pushed P → Awith lever pulled P-A → S
F
E
Cursore a centro aperto (P → S) inposizione centrale per cilindri asemplice effetto. Utilizzo chiuso. Aleva spinta P-B → S, a leva tirataP → B.Centre pilot shaft open (P → S) incentral position for single-acting cylin-ders. Service port closed.with lever pushed P-B → Swith lever pulled P → B
G
Cursore a centro aperto (P → S) inposizione centrale. Utilizzi allo sca-rico. A leva spinta P → A, B → S. A leva tirata P → B, A → S.Centre pilot shaft open (P → S) incentral position. Service ports in di-scharge.with lever pushed P → A, B → Swith lever pulled P → B, A → S
C
Cursore a centro aperto (P → S) inposizione centrale. Utilizzi chiusi.Per cilindri a doppio effetto con IVposizione flottante. A leva spintaP → A,B →S a leva ulteriormentespinta A-B → S con aggancio di rite-nuta. A leva tirata P → B, A → S.Centre pilot shaft open (P → S) incentral position. Service ports closed.For double-acting cylinders with 4thpos. floating with lever pushed P →A, B → S with lever pushed further A-B → S with engage.
1 2 3
1 2 3
1 2 3
1 2
1 2
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3 4
DISTRIBUTORI - DIRECTIONAL CONTROL VALVES OMFB S.p.A.
134-11 Pag.17
SCHEMI DEI TIPI DI AZIONAMENTODIAGRAMS OF OPERATION TYPES
SIGLACODE
CARATTERISTICHEFEATURES
SCHEMALAYOUT
Ritenuta a scatti in posizione 1 aleva tirata. Posizione centrale 2 sta-bile. Posizione 3 a leva spinta conritorno a molla al centro.Locked in position 1 with lever pulled.Central position 2 stable. Position 3with lever pushed and spring return tocenter.
13C
D
Azionamento con servocomandopneumatico posizione 2 stabile.Posizioni estreme 1-3 con ritornoal centro.Operation with pneumatic servo-con-trol. Position 2 stable.End positions 1-3 with return to cen-ter.
3S1R
212
Ritenuta a scatti nelle 4 posizioni.E possibile solo con cursore tipoG.Locked in 4 positions. Only possiblewith type G pilot shaft.
Ritenuta a scatti nelle posizioni 1-2posizione centrale e a leva tiratastabili.Locked in positions 1-2. Lever pulledand central position stable.
1234
13R
2P
Ritenuta a scatti in posizione 3 aleva spinta. Posizione centrale 2stabile. Posizione 1 con leva tiratacon ritorno a molla in posizione 2.Locked in position 3 with leverpushed in. Central position 2 stable.Position 1 with lever pulled andspring return to position 2.
1S3R
2
Azionamento con servocomandooleodinamico. Posizione 2 stabile.Posizioni 1-3 con ritorno a molla inposizione 2 (senza leva di aziona-mento).Operation with hydraulic servo-con-trol. Position 2 stable. Positions 1-3with spring return to position 2(without control lever).
23
Ritenuta a scatti nelle posizioniestreme. Trasitorio aperto= 4CTransitorio chiuso= 4DLocked in last position.Transien open= 4CTransien closed= 4D
Ritenuta a scatti nelle posizioni 2-3posizione centrale e la leva spintastabili.Locked in positions 2-3. Leverpushed in and central position stable.
13R
20
SIGLACODE
CARATTERISTICHEFEATURES
SCHEMALAYOUT
Posizione 2: stabile. Posizioni 1-3:ritorno molla in posizione 2.Position 2: stable. Positions 1-3:spring return in position 2.
13R
2
Posizione 2: stabile. Spingendo laleva vado in posizione 3. Rilascian-do torna in posizione 2.Position 2: stable. Push lever to go toposition 3. Release to return to posi-tion 2.3R
21R
2
Posizione 2: stabile. Tirando laleva vado in posizione 1. Rilascian-do torna in posizione 2.Position 2: stable. Pull lever to go toposition 1. Release to return to posi-tion 2.
Posizione 1: stabile. Leva normal-mente fuori. Spingendo la levavado in posizione 2. Rilasciandotorna in posizione 1.Position 1: stable. Lever normally pul-led out. Push the lever to go to posi-tion 2. Release to return to position 1.
2R1
3R1B
C/B
D
Posizione 1: stabile. Leva normal-mente fuori. Spingendo la levavado in posizione 3 Transitorioaperto = 213/B-C Transitorio chiu-so= 213/B-DPosition 1: stable. Lever normally pul-led out. Push lever to go to position 3Transient open= 213/B-CTransien closed= 213/B-D
123
Posizione 3: stabile. Leva normal-mente rientrata, tirando la levavado in posizione 1. Transitorio aperto= 213-C Transitorio chiuso= 213-D Position 3: stable. Lever normallypushed in. Pull lever to go in position1. Transient open=213-CTransien clo-sed= 213-D
1R3
Ritenuta a scatti nelle 3 posizioniThree position locking.
Posizione 3: stabile. Leva normal-mente dentro. Tirando la leva vadoin posizione 2. Rilasciando tornain posizione 3.Position 3: stable. Lever normallypushed in. Pull lever to go to position2. Release to return to position 3.
2R3
OMFB S.p.A. DISTRIBUTORI - DIRECTIONAL CONTROL VALVES
Pag.18 134-11