Industrial | Harsh Environment Fiber Cables
Prysmian offers a full line of Industrial/Harsh Environment fiber cable for applications such as:
- Chemical Processing
- Pipelines
- Oil & Gas
- Factory Automation
- Public Transit
- Mines
- River Crossings/Marine
- Airports
- Security
- Fire Resistance
- Waste Water
Prysmian’s line of Industrial/ Harsh Environment fiber cables are designed, built and tested to withstand rugged conditions such as:
- Chemical Resistance
- High Crush Strength
- Extreme Temperature
- High Tensile Strength
- Fire and Heat Resistance
- Abrasion Resistance
- Oil and Gas Resistance
- High Impact Resistance
The Prysmian Group provides optical fiber cabling solutions designed specifically for use in industrial and harsh environments, such as, mining, aviation, transit, tunnels, petrochemical, waste water, pipelines and oil & gas. These applications include conditions where cable is exposed to extreme temperature variations, vibration, corrosive chemicals and other challenging environmental elements. Prysmian offers a complete family of outdoor, indoor & specialty fiber cables, which allows our customers to do more, make more, save more and achieve more. Cables are available with a complete line of single-mode, multimode and specialty optical fibers to fit virtually any application.
+1-800-669-0808 | +1-800-879-9862 na.prysmiangroup.com/telecom
2
ezLINK™ Oil & Gas | Riser LSZH | High Crush | Loose Tube (dry)Industrial | Chemical Resistant | Tray Rated | Indoor/Outdoor Cables
AIRGUARD™ XP - Chemical Resistant | High Crush | Low-TempPetrochemical | Utility | Waste Water | Tray Rated
ezLINK™ Industrial Riser LSZH Loose Tube (dry)Indoor/Outdoor | LSZH | Tray Rated Cables
CampusLink LT™ Loose Tube | Indoor/OutdoorRiser / Plenum Rated Cables with Gel-Free Buffer Tubes
- Loose tube optical cable- Gel filled buffer tubes- Chemical resistant- 12 to 288 optical fibers- Double or single jacket, all-dielectric, armored- Available with SMF & MMF optical fibers- Flame rating: OFNG-LS/FT4 ST1- UL 2556 4.2.8.3 “oil resistance” PRII- UL 2556 4.2.8.4 “gasoline resistance” GRII- Direct Buried rated – DIR BUR- UV resistance rated – SUN RES
REFERENCE PRODUCT CODE: XRPLTM
- Loose tube optical cable- Gel-free buffer tubes- LSZH, double jacket, armored- 12 to 288 optical fibers- Available with SMF & MMF optical fibers- Flame rating: OFNR-LS/FT4 ST1- Direct Buried rated – DIR BUR- UV resistance rated – SUN RES
REFERENCE PRODUCT CODE: IRZHFFlame Low
Smoke Chemical Tray Crush Tensile UV Zero Halogen
- Loose tube optical cable- Gel-free (dry) buffer tubes- ezINTERLOCK armor- 12 to 288 optical fibers- Available with SMF & MMF optical fibers- Flame rating: OFCR/FT4, OFCP/FT6
REFERENCE PRODUCT CODE: DRLDBAJ -RISER DPLDBAJ -PLENUM
Low Temp
ezINTERLOCK™ | Indoor/Outdoor Loose TubeRiser / Plenum Rated Cables
- Loose tube optical cable- Gel-free (dry)buffer tubes- LSZH, single jacket, all-dielectric- 12 to 288 optical fibers- Available with SMF & MMF optical fibers- Flame rating: OFNR-LS/FT4 ST1- Direct Buried rated – DIR BUR- UV resistance rated – SUN RES
REFERENCE PRODUCT CODE: IRZH
- Loose tube optical cable- Gel-free (dry) buffer tubes- Single jacket, armored- 12 to 288 optical fibers- Available with SMF & MMF optical fibers- Flame rating: OFNR/FT4, OFNP/FT6
REFERENCE PRODUCT CODE: DRLD -RISER DPLD -PLENUMFlame
Flame
UV
UV
Flame Low Smoke Chemical UV Zero
HalogenLow
TempTray
Tray
Tray
+1-800-669-0808 | +1-800-879-9862 na.prysmiangroup.com/telecom
Flame Low Smoke Chemical Oil Gasoline Tray Crush Tensile UVLow
Temp
3
ezLINK™ Transit/LSZH Loose Tube (dry)Low-Smoke Zero-Halogen Cables with Gel-Free Buffer Tubes
ezLINK™ Indoor/Outdoor Loose Tube Mining CableMSHA and Tray Cables
ezINTERLOCK™ Indoor/Outdoor Tight BufferedRiser and Plenum Rated Cables
Temp
Flame Tray Crush Tensile
ezDISTRIBUTION™ Indoor/Outdoor Tight BufferedRiser and Plenum Cables
Flame UV
- Indoor/outdoor- Tight buffer distribution- 900μm tight buffer fibers- Riser: 2-144 fiber count- Plenum: 2-96 fiber count- Available with SMF & MMF optical fibers- Flame rating: OFNR/FT4 & OFNP/FT6
REFERENCE PRODUCT CODE: C1181 -RISER C1182 -PLENUM
ezDISTRIBUTION™ Indoor/Outdoor LSZH TBLow-Smoke Zero-Halogen Cables
Flame UV
Flame UV
- Indoor/outdoor- Tight buffer distribution- 900μm tight buffer fibers- Riser: 2-144 fiber count- LSZH Jacket- Available with SMF & MMF optical fibers- Flame rating: OFNR/FT4
REFERENCE PRODUCT CODE: 700
- Indoor/outdoor- Tight buffer distribution- 900μm tight buffer fibers - Aluminum or steel interlocking armor- Riser: 2-144 fiber count- Plenum: 2-96 fiber count- Available with SMF & MMF optical fibers- Flame rating: OFCR/FT4 & OFCP/FT6
REFERENCE PRODUCT CODE: C1181AJ -RISER C1182AJ -PLENUM
- Loose tube optical cable- Gel filled buffer tubes- Chemical resistant, double jacket, all-dielectric- 2 to 144 optical fibers- Available with SMF & MMF optical fibers- Flame rating: OFNR/FT4- MSHA & Pennsylvania Bureau of Deep Mine Safety
REFERENCE PRODUCT CODE: RLTM
- Loose tube optical cable- Gel-free (dry) buffer tubes- LSZH, single jacket, armored- 12 to 288 optical fibers- Available with SMF & MMF optical fibers- Flame rating: OFNR-LS/FT4 ST1 OFCR-LS/FT4 ST1
REFERENCE PRODUCT CODE: DDLZHFlame Low Smoke UV Zero
HalogenLow
Temp
+1-800-669-0808 | +1-800-879-9862 na.prysmiangroup.com/telecom
4
+1-800-669-0808 | +1-800-879-9862 na.prysmiangroup.com/telecom
Airguard™XP -Oil andGas UtilityLow-TempHigh Crush
ezLINK™ Heavy Duty Industrial
Riser LSZH (dry) High
Crush
ezLINK™ Industrial
RiserLSZH Dry
Loose Tube
CampusLink LT™
Indoor/Out-door Loose
Tube
CampusLink LT™
DryIndoor/Outdoor
Loose Tube
ExpressLT™All-Dielectric
Armored(gel or dry) Loose Tube
ezDISTRIBUTION™Riser Indoor/
OutdoorTight Buffered
ezDISTRIBUTION™ Plenum
Indoor/OutdoorTight Buffered
ezDISTRIBUTION™Riser LSZH Indoor/
OutdoorTight Buffered
Mining Indoor/Outdoor
Riser Loose Tube
Outdoor FAA All-Dielectric
Loose Tube
Product Family -->Airguard
XPIRZHF IRZHx DRLxx DPLDB
EDHDA2JKT ETHDA2JKT
C1181 C1182 700 RLTM FAA
Application Low-Temp, High Crush
Low-Temp, LSZH, High
Crush
LSZH General
Application
Riser
General Application
Plenum
OSP All-
Dielectric Rodent
Resistant
General Application
Riser
General Application
Plenum
General Application
LSZH RiserMining Airports
Cable Type
Indoor/ Outdoor
Loose Tube
Indoor/ Outdoor
Loose Tube
Indoor/ Outdoor
Loose Tube
Indoor/ Outdoor
Loose Tube
Indoor/ Outdoor
Loose Tube
Outdoor Loose Tube
Indoor/ Outdoor Tight
Buffer
Indoor/ Outdoor Tight
Buffer
Indoor/ Outdoor Tight
Buffer
Indoor/ Outdoor
Loose Tube
Outdoor
Loose Tube
Gel Filled Tube yes no no yes no no n/a n/a n/a yes yes
Fiber Count 2 to 288 2 to 288 2 to 288 2 to 132 2 to 144 4 to 432 2 to 144 2 to 96 2 to 24 2 to 144 2 to 60
Qualified Fibers ALL No 50 µm ALL ALL ALL ALL ALL ALL ALL ALL ALL
Corrugated Steel Tape Option no no yes
(PSP)yes
(PSP) no no no no no no no
Interlock Armor no no yes yes yes yes yes yes yes no no
Flame Rating OFNG-LSFT4 ST1
OFR-LS FT4 ST1
OFR-LS FT4 ST1
OFNR FT4
OFNP FT6 none OFNR
FT4OFNP FT6
OFNR FT4
OFNR FT4 none
MSHA Listing no no no no no no no no no yes no
Low Smoke yes yes yes no yes no no yes yes no no
Zero Halogen no yes yes no no no no no yes no no
Recommended for Tray Usage yes yes yes no no no no no no yes no
Installation Tensile Load (N) 4500 4500 2670
to 4500 2700 2700 4500 445 to 2670
445 to 2670
660 to 1320 4500 2700
High Compressive Resistant yes yes no no no yes no no no yes no
Low Temperature Mechanicals yes yes no no no no no no no no no
Operating Temperature
-50°C to 70°C
-50°C to 70°C
-50°C to 70°C
-50°C to 70°C
-40°C to 70°C
-40°C to 70°C
-40°C to 80°C
-40°C to 80°C
-40°C to 80°C
-50°C to 70°C
-40°Cto 70°C
Installation Temperature
-30°C to 60°C
-30°C to 60°C
-30°C to 60°C
-10°C to 60°C
0°C to 60°C
-30°C to 60°C
-10°C to 60°C
0°C to 60°C
-10°C to 50°C
-10°C to 60°C
-30°Cto 60°C
UV Resistant Jacket yes yes yes yes yes yes yes yes yes yes yes
Chemical Resistance (Scale: 1 to 4) 4 being the best
3 2 2 1 4 1 1 3 2 1 4
Oil and Gas Resistance (Scale: 1 to 4) 4 being the best
4 3 2 1 4 1 1 4 2 2 4
*outer jacket type is fiber count specific
FLAME RATING TERMS: OFN = Optical Fiber Non-conductive OFNG = Optical Fiber Non-conductive General Purpose OFNR FT4 = Optical Fiber Non-conductive riser - USA & Canada OFNP FT6 = Optical Fiber Non-conductive Plenum - USA & Canada LS ST1 = Low Smoke - USA & Canada * Optical cables become conductive with metalic armoring wherein the “N” (non-conductive) term converts to a “C” (conductive) when metalic armor is applied. ie: OFNR vs OFCR
Product Selection Chart
5+1-800-669-0808 | +1-800-879-9862 na.prysmiangroup.com/telecom
Ordering Guide - SPECIALTYThe Prysmian Group part number incorporates several significant attributes involving cable design and optical performance. The appropriate part number can be configured using the process described below
Example: AirGuard™ XP XPRLTM, 12 fibers per tube, with 72 single-mode fibers, 0.4/0.4/0.3 dB/km @1310/1383/1550
F XPRLTM 12 HB 072 E1– – – – –1 2 3 4 5 6 7LENGTH
MARKINGSPRODUCTFAMILY
FIBERGROUPINGCONSTRUCTION FIBER TYPE FIBER COUNT FIBER GRADE
PART NUMBER CONSTRUCTION
LENGTH MARKINGS
F = Feet or M = Meters
PRODUCT FAMILY
REFER to SPECIALTY PRODUCTS TABLE BELOW
CONSTRUCTION
INTERLOCK ARMOR (Optional)
(blank) =none
AJ = Jacketed Aluminum
SJ = Jacketed Steel
AB = Bare Aluminum
SB = Bare Steel
FIBER GROUPING
00 = no grouping | Central LT
06 = 6f per unit or tube
12 = 12f per unit or tube
1
2
2
3
4
FIBER INFORMATION
FIBER TYPE (LT) LOOSE TUBE
SINGLE-MODE (LT)Wavelength: 1310/1383/1150 nm | Attenuation: 0.4/0.4/0.3 dB/km
HB = Single-Mode (ITU G.652 D) Low Water Peak
ES = Enhanced Single-Mode (ITU G.652 D)
CE = Corning™ Single-Mode (ITU G.652 D Compliant)
B1 = Bend-Insensitive Single-Mode (ITU G.657.A1 & G.652.D)
B2 = Bend-Insensitive Single-Mode (ITU G.657.A2 & G.652.D)
BX = Bend-Insensitive Single-Mode (ITU G.657.A2 & .B2, & G.652.D)
MULTIMODE (LT)Wavelength
(mm)Bandwidth
(MHz)1GbE
Dist (m)10 GbE
Dist (m)
G6 = OM1 (62.5µm) 850/1300 200/500 300/550 33/____
G5 = OM2+ BIF (50µm) 850/1300 700/500 800/550 150/____
G3 = OM3 BIF (50µm) 850/1300 1500/500 1000/550 300/____
G4 = OM4 BIF (50µm) 850/1300 3500/500 1100/550 550/____
FIBER COUNT
002 to 288 fibers
5
6
PRODUCT FAMILY - SPECIALTY INDOOR/OUTDOOR PRODUCTS TABLE
InterLock
FlameRating
InterLock
FlameRating
Airguard™ XP Harsh Environment / Petro Chemical / Tray - Loose Tube (LT) Mining - Harsh Environment / Gel-Filled - LT
XPRLTM = 2 to 288f Oil & Gas, Harsh, Low Temp Cable, Tray, 2 Jackets N OFNG-LS/FT4 ST1 RLTM = 2 to 144f MINEnet. I/O Riser, 2 Jacket N OFNR/FT4
XPRLTMB = 2 to 216f I/O Harsh,1 Jackets N OFN Airport Cable (FAA)
XPRLTMD = 2 to 216f I/O Harsh, Armored, 2 Jackets N OFC FAACF = 2 to 60f ezLink™ Loose Tube, All-Dieletric, 2 Jackets N N/A
Industrial / Low-Smoke Zero Halogen (LSZH) / Dry (Gel-Free) / Tray - LT Heavy Duty - Harsh Environment / Tray / Interconnect
IRZHB = 2 to 288f ezLink™ Indust. Riser, All-Dieletric, Tray, 1 Jacket Y OFNR-LS/FT4 MDU829 = 1f ezINTERCONNECT™ Indoor 2.9mm Drop N OFNR/FT4
IRZHC = 2 to 288f ezLink™ Indust. Riser, All-Dieletric, Tray, 2 Jackets N OFNR-LS/FT4 MDU548 = 1f ezINTERCONNECT™ Indoor, 4.8mm Drop N OFNR/FT4
IRZHD = 2 to 288f ezLink™ Indust. Riser, Tray Armored, 2 Jackets N OFNR-LS/FT4 MDU548BK = 1f ezINTERCONNECT™ I/O 4.8mm Drop N OFNR/FT4
Heavy Duty - Harsh Environment / LSZH / Dry (Gel-Free) / Tray - LT Tight Buffer (TB) Distribution / Indoor-Outdoor / Plenum & Riser
IRZHF = 2 to 288f ezLink™ Oil & Gas, HD, All-Dieletric, Tray, 1 Jacket N OFNR-LS/FT4 ST1 C1181 = 2-144F ezDistribution I/O TB Distribution (Riser) Y OFNR/FT4
Transit / LSZH / Dry (Gel-Free) - LT C1182 = 2-96F ezDistribution I/O TB Distribution (Plenum) Y OFNP/FT6
DDLSZHB = 2 to 288f ezLink™ Transit LSZH, All-Dieletric, 1 Jacket Y OFNR-LS/FT4 PIPELINE Sensing / LT&TB Hybrid
DDLSZHC = 2 to 288f ezLink™ Transit LSZH, All-Dieletric, 2 Jackets N OFNR-LS/FT4 ETS (gel-filled) 6 position LT w 2-4 TB simplex units & 2-4 LT units
DDLSZHE = 2 to 288f ezLink™ Transit LSZH, Armored, 1 Jacket N OFNR-LA/FT4 EDS (gel-free) 6 position LT w 2-4 TB simplex units & 2-4 LT units
Industrial & Transit / LSZH / Gel-Filled - LT
Note: See the data sheet since a different part number configuration is used.DLSZHB = 2 to 216f ezLink™ Transit LSZH I/O Riser, 1 Jacket Y OFN-LS
DLSZHC = 2 to 288f ezLink™ Transit LSZH, All-Dieletric, 2 Jackets N OFN-LS
DLSZHD = 2 to 288f ezLink™ Transit LSZH, Armored, 2 Jackets N OFC-LS
FIBER GRADE
SINGLE-MODE | Loose Tube LTAttenuation (dB/km) Wavelength (nm) Fiber Type
E1 = 0.40/0.40/0.30 1310/1383/1550 HB, ES, CE, B1, B2, or BX
E3 = 0.35/0.35/0.25 1310/1383/1550 HB, ES, CE, B1, B2, or BX
SINGLE-MODE | Tight Buffer TBAttenuation (dB/km) Wavelength (nm) Fiber Type
EB = 0.70/0.70/0.70 1310/1383/1550 HB, ES, CE, B1, B2, or BX
MULTIMODEAttenuation (dB/km) Wavelength (nm) Fiber Type
M2 = 3.5/1.0 dB/km 850/1300 OM1 (62.5µm)
M3 = 3.0/1.0 dB/km 850/1300 OM2+, OM3, OM4 (50µm)
Other cable constructions and fiber performance grades available.
7
6
+1-800-669-0808 | +1-800-879-9862 na.prysmiangroup.com/telecom
NOTES
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
7+1-800-669-0808 | +1-800-879-9862 na.prysmiangroup.com/telecom
NOTES
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
© DRAKA & PRYSMIAN - Brands of The Prysmian Group. 2017 All Right Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed correct at the time of issue. Prysmian Group reserves the right to amend any specifications without notice. These specifications are not contractually valid unless specifically authorized by Prysmian Group. Issued January 2017.
website: na.prysmiangroup.com/telecom
+1-800-669-0808+1-800-879-9862
Linking communications to communities
For more information, visit:
Prys
mia
n In
dust
rial/
Har
sh E
nviro
nmen
t B
roch
ure_
03-2
017