installation 1/5 pattern guidelinesfor a pattern larger than a set of 1,4,6 or 12, install...

6
Optionally create Secondary Branches at available locations while creating the path. High & Low Nodes must always alternate and they are of equal quantity in a set. PRIOR TO INSTALLATION: DESIGN A PATTERN A plan of the desired pattern shall be created by the project designer and supplied to installers. 1 (12” size) + 1 (17” size) 2 single units (not connected together) which require 2 junction boxes (J-Box)& line connections. Both are Low height units. Set of 4 4 units connected together. 1 J-Box & Line connection any High (overlapping) units. Set of 6 6 units connected together. 1 J-Box & Line connection in any taller (overlapping) unit. 4 Sets: 4,6 (12”) + 2x1 (17”) 4 J-Boxes & Line connections. In sets 4 &6 the J-Box can be any of the High units. Node Single units are Low (underlapping). 3 Sets: 1,4,6 (overlapped together) 3 J-Boxes & Line connections: in sets 4&6, located in any of the High units of set. Set of 12 (12” only) 1 J-Box & Line connection, which must be located in the center High unit (to split the circuit current in 2). PATTERN GUIDELINES: Secondary Branch Side view: Alternating heights With a set of 12, the JUNCTION BOX with LINE connection must be the MIDDLE High Node of the pattern. For sets of 4 & 6 it can be any of the High units. Set of 12: power connection in the middle 4 5 Start with a Node fixture connected to a Junction Box. It can have the point facing upwards or sideways. Add a second low underlapping Node in any of the 6 angles. OR 1 Connect subsequent Nodes in angles of 0°, +60° and -60° always alternating a high and low node. 2 Connect additional Nodes within the set in a continuos path. For a pattern larger than a set of 1,4,6 or 12, install additional sets in proximity to enlargen the pattern further. 3 Several J-Box location choices (High units) Low High(overlapping) Choice Choice Low single unit High High High High Low High Low High Low Choice Choice Center J-box PATTERN EXAMPLES : Several J-Box location choices 225 de Liège Ouest, Suite #200 Montréal (QC), Canada H2P 1H4 Tel : 514.385.3515 Fax : 514.385.4169 www.eurekalighting.com INSTALLATION PATTERN GUIDELINES 3446X-XX Node Wall & ceiling fixture Applique murale ou plafonnier 1/5

Upload: others

Post on 27-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INSTALLATION 1/5 PATTERN GUIDELINESFor a pattern larger than a set of 1,4,6 or 12, install additional sets in proximity to enlargen the pattern further. 3 Several J-Box location choices

Optionally create Secondary Branches at available locations while creating the path. High & Low Nodes must always alternate and they are of equal quantity in a set.

PRIOR TO INSTALLATION: DESIGN A PATTERNA plan of the desired pattern shall be created by the project designer and supplied to installers.

1 (12” size) + 1 (17” size)2 single units (not connected together) which require 2 junction boxes (J-Box)& line connections.Both are Low height units.

Set of 4 4 units connected together.1 J-Box & Line connection any High (overlapping) units.

Set of 66 units connected together. 1 J-Box & Line connection in any taller (overlapping) unit.

4 Sets: 4,6 (12”) + 2x1 (17”)4 J-Boxes & Line connections. In sets 4 &6 the J-Box can be any of the High units. Node Single units are Low (underlapping).

3 Sets: 1,4,6 (overlapped together)3 J-Boxes & Line connections: in sets 4&6, located in any of the High units of set.

Set of 12 (12” only)1 J-Box & Line connection, which must be located in the center High unit (to split the circuit current in 2).

PATTERN GUIDELINES:

Secondary Branch

Side view:Alternating heights

With a set of 12, the JUNCTION BOX with LINE connection must be the MIDDLE High Node of the pattern. For sets of 4 & 6 it can be any of the High units.

Set of 12:power connection

in the middle

4 5

Start with a Node fixture connected to a Junction Box. It can have the point facing upwards or sideways. Add a second low underlapping Node in any of the 6 angles.

OR

1Connect subsequent Nodes in angles of 0°, +60° and -60° always alternating a high and low node.

2

Connect additional Nodes within the set in a continuos path. For a pattern larger than a set of 1,4,6 or 12, install additional sets in proximity to enlargen the pattern further.

3

Several J-Boxlocation choices(High units)

LowHigh(overlapping)

Choice

Choice

Low singleunit

High

High

High

HighLowHighLow

High

Low

Choice

Choice

CenterJ-box

PATTERN EXAMPLES :

Several J-Boxlocation choices

225 de Liège Ouest, Suite #200Montréal (QC), Canada H2P 1H4Tel : 514.385.3515 Fax : 514.385.4169www.eurekalighting.com

INSTALLATIONPATTERN GUIDELINES

3446X-XXNode

Wall & ceiling fixtureApplique murale ou plafonnier

1/5

Page 2: INSTALLATION 1/5 PATTERN GUIDELINESFor a pattern larger than a set of 1,4,6 or 12, install additional sets in proximity to enlargen the pattern further. 3 Several J-Box location choices

Ajouter en option des branches secondaires aux angles disponibles. Les Nodes doivent toujours alterner haut & bas qui sont en quantité égaux dans un ensemble.

AVANT L’INSTALLATION: DESSINER UN MOTIFUn plan du motif d’emplacement des luminaires Node devrait être crée par le design du projet et fourni aux installateurs.

1 (format 12”) + 1 (format 17”)2 unités séparés (pas ensembles) qui nécessite 2 boites de jonction avec alimentation. Les deux unités sont basses.

1 Ensemble de 44 unités connectés ensemble.1 boitier d’alimentation dans une des unités hautes (superposé).

1 Ensemble de 66 unités connectés ensemble.1 boitier d’alimentation dans une des unités hautes (superposé).

4 ensembles : 4,6 (12”) + 2x1 (17”)4 boitiers d’alimentation: pour ensembles 4&6 il peut être dans toute unité haute. Les 2 unités seules sont avec boitier d’alimentation & sont basses.

3 ensembles : 1,4,6 (se chevauchent)3 boitiers d’alimentation: pour ensembles 4&6 il peut être dans toute unité haute. L’unité seule est basse et passe en dessous.

Ensemble de 12 (format 12”)1 boitier d’alimentation qui doit se localiser dans l’unité haute du centre (pour séparer également le courant en 2).

PRINCIPLES DE CRÉATION DE MOTIF:

Secondary Branch

Side view:Alternating heights

Dans un ensemble de 12, la boite de jonction/alimentation doit être le Node haut dans le milieu du motif. Dans des ensembles de 4 ou 6 l’alimentation peut être dans n’importe quelle des unités hautes.

Set of 12:power connection

in the middle

4 5

Débuter avec le Node installé sur une boite de jonction. Il peut pointer vers le haut ou le coté. Ajouter un 2ième avec le boitier bas dans une des 6 directions.

OR

1Connecter des Nodes subséquants dans des angles de 0°, +60° &-60° toujours en alternant un Node haut et bas.

2

Connecter les autres Nodes de l’ensemble dans un chemin continu. Pour un motif plus étendu que 1,4,6 ou 12, installer à proximité des ensembles additionelles pour élargir le motif.

3

choix d’emplacementde boitiers d’alimentation(Unités hautes)

BasHaut (superposé)

Choix

High

High

High

HighLowHighLow

High

Low

Choix

Boitier alimentéau centre

EXEMPLES DE MOTIFS:

Several J-Boxlocation choices

Choix1 Unité basse

Choix

225 de Liège Ouest, Suite #200Montréal (QC), Canada H2P 1H4Tel : 514.385.3515 Fax : 514.385.4169www.eurekalighting.com

INSTALLATIONCRÉATION DE MOTIF

3446X-XXNode

Wall & ceiling fixtureApplique murale ou plafonnier

2/5

Page 3: INSTALLATION 1/5 PATTERN GUIDELINESFor a pattern larger than a set of 1,4,6 or 12, install additional sets in proximity to enlargen the pattern further. 3 Several J-Box location choices

! ALTERNATEHIGH & LOW

HIGH UNITFELT SHADEABAT-JOUR

LOW UNIT

WHITE (NEUTRAL) /BLANC (NEUTRE)

BLACK (LINE WIRE) / NOIR (FIL EN TENSION)

GROUND WIRE / FIL DE MISE À TERRE

GRAY DIMMING -/ GRIS GRADATION -

PURPLE DIMMING + / MAUVE GRADATION +

DO NOT LIGHT UP BEFORE ALL MODULES ARE CONNECTED! /NE PAS ALLUMER AVANT QUE TOUS LES MODULES SOIENT CONNECTÉS

! VERIFY PATTERNFOR ORIENTATION

! VERIFY PROJECT PATTERN DRAWING FOR DIRECTION & ANGLES

LEVEL

OR

A

R

B

RB

RB

LEDDRIVER

?

?

?

?

B

C

E

E

G

G

F

D

C

225 de Liège Ouest, Suite #200Montréal (QC), Canada H2P 1H4Tel : 514.385.3515 Fax : 514.385.4169www.eurekalighting.com

3446X-XXNode

INSTALLATIONMAINTENANCE1

5

INSTALLATION:1 - SCREW UNIVERSAL PLATE (A) TO OCTAGONAL BOX. CONNECT LINE, NEUTRAL, GROUND & DIMMING WIRES (WIRE NUTS+SCREWS NOT SUPPLIED).

2 - SECURE HOUSING (B) TO UNIVERSAL PLATE (A) WITH SUPPLIED #8-32 SCREWS (C): HOUSING TIP POINTS UP OR SIDEWAYS AS PER PATTERN SUPPLIED BY PROJECT DESIGNER. FOR A SINGLE FIXTURE SKIP TO STEP 9.

3 - BEND 1,2 OR 3 SIDE TABS IN LOCATIONS AS PER DESIGNER PATTERN.

4 - INSERT CONNECTOR ROD(D) IN HOLE WITH BIGGER CONNECTOR FIRST.

5 - FASTEN #M3 CONNECTOR ROD SCREW (E) TO HOUSING.

6 - POSITION ANOTHER UNIT (DIFFERENT HEIGHT) AS PER PATTERN, REMOVE CORRECT SIDE TAB FOR DESIRED ROD ANGLE, PASS WIRES THRU, FASTEN ROD SCREW (E).

7 - ALIGN & LEVEL THE HOUSING AND FASTEN TO SURFACE WITH 2 SCREWS AND WALL ANCHORS (F) (NOT SUPPLIED). REPEAT STEPS 3-7 TO FOR REMAINING UNITS AS PER PATTERN DESIGN.

8 - WIRE CONNECTIONS (SEE PAGES 3-4): IDENTIFY THE TYPE OF UNIT & QUANTITY OF CONNECTION RODS AND FOLLOW CORRESPONDING WIRING DIAGRAM. WHEN CONNECTIONS ARE COMPLETE, MAKE A FINAL VERIFICATION BEFORE SWITCHING ON LINE POWER.

9 - FELT SHADE: FOR UNIT WITH LED DRIVER FASTEN 2 WHITE SIDE SCREWS (G) (SUPPLIED) ON FELT SHADE WITH COVER PLATE. MAGNETIC SHADES: ALIGN & PLACE MAGNETS TO 3 UNIT ARMS.

INSTALLATION:1 - VISSER PLAQUE UNIVERSEL (A) À LA BOITE DE JONCTION. CONNECTER FILS DE TENSION, NEUTRE & DIMMING (VIS & CONNECTERS NON-FOURNIS)

2 - VISSER BOITIER (B) À LA PLAQUE AVEC VIS FOURNIES #8-32 (C) ORIENTANT VERS LE HAUT OU COTÉ SELON LE MOTIF FOURNI PAR LE DESIGNER DU PROJET. POUR UNE SEULE FIXTURE, PASSER À L’ÉTAPE 9.

3 - ENLEVER 1,2, OU 3 OUVERTURES DE COTÉ SELON MOTIF DU DESIGNER.

4 - INSERER BARRE DE CONNECTION (D) AVEC CONNECTEUR LARGE EN 1ER.

5 - SERRER VIS #M3 DE LA BARRE (E) DANS LE BOITIER

6 - POSITIONNER UN AUTRE FIXTURE (HAUTEUR DIFFÉRENTE) SELON MOTIF. PLIER L’OUVERTURE CORRESPONDANTE, PASSER FILS, SERRER VIS (E).

7 - ALIGNER & METTRE À NIVEAU LE BOITIER & VISSER À LA SURFACE AVEC 2 VIS & ANCRAGES (F) (NON-FOURNIS).RÉPÉTER ÉTAPES 3-7 POUR LES AUTRES.

8 - CONNECTIONS DE FILS (VOIR PAGES 3-4): IDENTIFIER LE TYPE DE FIXTURE & QUANTITÉ DE BARRES DE CONNECTION & SUIVRE LE DESSIN DE CONNECTION CORRESPONDANT. AVEC TOUS LES CONNECTIONS COMPLÉTÉS FAITES UNE VÉRIFICATION FINALE AVANT DE METTRE EN TENSION.

9 - ABAT-JOUR: POUR FIXTURE AVEC UNITÉ D’ALIMENTATION, SÉLÉCTIONNER L’ABAT-JOUR AVEC COUVERT & VISSER AVEC 2 VIS BLANCHES (G) (FOURNIES). ABATS-JOURS AVEC AIMANTS: ALIGNER SUR 3 BRAS & PLACER.

3

2

4

6 7

8

9

Wall & ceiling fixtureApplique murale ou plafonnier

3/5

WIRE CONNECTIONS : SEE PAGES 4-5 CONNECTIONS DE FILS : VOIR PAGES 4-5

!

Page 4: INSTALLATION 1/5 PATTERN GUIDELINESFor a pattern larger than a set of 1,4,6 or 12, install additional sets in proximity to enlargen the pattern further. 3 Several J-Box location choices

R

R

R

B

RB

RB

RB

RBR

BR

B

B

B

WIRE CONNECTIONS: STANDARD UNIT

Notes:

1. Connector rods may be positioned differently than shown, as long as the quantity is the same.

2. Red & black wire colors always alternate at connections.

CONNECTIONS : UNITÉ STANDARD

Notes:

1. Les barres de connection peuvent être placées différement que ci-bas, avec une pareil quantité.

2. Les fils rouges & noires alternent toujours aux connections.

2 RODS

3 RODS

1 CONNECTOR ROD

B = BLACK WIRER = RED WIRE

1 BARRE DE CONNECTION(TOUS LES ENSEMBLES)

2 BARRES DE CONNECTION(TOUS LES ENSEMBLES)

3 BARRES DE CONNECTION(TOUS LES ENSEMBLES)

WITH 1 CONNECTOR ROD(ALL SETS)

WITH 3 CONNECTOR RODS(ALL SETS)

WITH 2 CONNECTOR ROD(ALL SETS)

225 de Liège Ouest, Suite #200Montréal (QC), Canada H2P 1H4Tel : 514.385.3515 Fax : 514.385.4169www.eurekalighting.com

INSTALLATIONMAINTENANCE

3446X-XXNode

Wall & ceiling fixtureApplique murale ou plafonnier

5/5

Page 5: INSTALLATION 1/5 PATTERN GUIDELINESFor a pattern larger than a set of 1,4,6 or 12, install additional sets in proximity to enlargen the pattern further. 3 Several J-Box location choices

LED

DR

IVE

R

1 CONNECTOR ROD

LED DRIVER

RB

R

B

R

B R

B

R

B

R

RB

B

R

BR

B

RB R

B

R

BR

B

WIRE CONNECTIONS: UNIT WITH LED DRIVER

Notes:

1. Connector rods may be positioned differently than shown, as long as the quantity is the same.

2. Red & black wire colors always alternate at connections.

CONNECTIONS : UNITÉ AVEC UNITÉ D’ALIMENTATION

Notes:

1. Les barres de connection peuvent être placées différement que ci-bas, avec une pareil quantité.

2. Les fils rouges & noires alternent toujours aux connections.

CONNECT TO 6 UNITS

CONNECT TO 5 UNITS

2 RODS

2 RODS

3 RODS

LED DRIVER

LED DRIVERLED

DRIVER

B = BLACK WIRER = RED WIRE

1 CONNECTOR ROD(SETS OF 4 & 6 UNITS)

1 BARRE DE CONNECTION(ENSEMBLES DE 4 & 6 UNITÉS)

2 BARRES DE CONNECTION(ENSEMBLES DE 4 & 6 UNITÉS)

3 BARRES DE CONNECTION(ENSEMBLES DE 4 & 6 UNITÉS)

2 CONNECTOR RODS(SETS OF 4 & 6 UNITS)

3 CONNECTOR RODS(SETS OF 4 & 6 UNITS)

2 CONNECTOR RODS (SET OF 12 UNITS). THIS UNIT MUST CONNECT TO 6 ON ONE SIDE AND 5 ON THE OTHER AS THE CURRENT IS DIVIDED IN 2.

2 BARRES DE CONNECTION (ENSEMBLE DE 12 UNITÉS). CETTE UNITÉ SE PLACE AU MILIEU AVEC 6 UNITÉS D’UN COTÉ ET 5 DE L’AUTRE POUR DIVISER LE COURANT EN 2.

225 de Liège Ouest, Suite #200Montréal (QC), Canada H2P 1H4Tel : 514.385.3515 Fax : 514.385.4169www.eurekalighting.com

INSTALLATIONMAINTENANCE

3446X-XXNode

Wall & ceiling fixtureApplique murale ou plafonnier

4/5

Page 6: INSTALLATION 1/5 PATTERN GUIDELINESFor a pattern larger than a set of 1,4,6 or 12, install additional sets in proximity to enlargen the pattern further. 3 Several J-Box location choices

FOR DIMMABLE LUMINAIRESPOUR LES LUMINAIRES À VARIATION D’INTENSITÉ LUMINEUSE

For best dimming results, verify dimmer compatibilityPour une gradation optimale, vérifiez la compatibilité du gradateur

Your luminaire will be configured with one dimming type:Votre luminaire peut être configuré avec gradation de type:

Input 120-277VEntrée 120-277V

To 0-10V dimmer (gray/purple)Vers gradateur 0-10V (gris/mauve)

DriverAlimentation

To LED light sourceVers source DEL

+-L

N

DIM+DIM-

Input 120V onlyEntrée 120V seul.

DriverAlimentation

To LED light sourceVers source DEL

+-L

N

DIM+DIM-Capped or inexistant wiresFils coiffés ou inexistants

Not all luminaires have both dimming options. For more information on dimming, please visit our website or contact our customer service. Pas tous les luminaires ont les deux options de gradation. Pour plus d’information sur la gradation, visitez notre site web ou contactez notre service à la clientèle.www.eurekalighting.com

DP / PHASEPhase dimming products (DP) do not require the use of the purple and gray wires

(capped). Works for 120V circuits only.

La gradation de type Phase (DP) ne requiert pas l’utilisation des fils mauve et gris (fils coiffés). Circuits 120V seulement.

DV / 0-10V0-10V dimming products (DV) require the use of the purple and gray wires. Works

with 120-277V circuits.

La gradation de type 0-10V (DV) requiet l’utilisation des fils mauve et gris. Circuits 120-277V.