installation guide devireg™ smartntc n l a d. devireg™ smart installation guide 11 the female...

24
www.DEVI.com Installation Guide DEVIreg™ Smart Intelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control

Upload: others

Post on 16-Apr-2020

10 views

Category:

Documents


0 download

TRANSCRIPT

www.DEVI.com

Installation Guide

DEVIreg™ SmartIntelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control

DEVIreg™ Smart

Installation Guide2

1 Introduction

DEVIreg™ Smart is an electronic programmable timer thermostat used for controlling electrical floor heating elements. The thermostat is designed for fixed installation only and can be used for both direct heating of the entire room and for comfort heating of the floor. Among others, the thermostat has the following features:

1 Introduction � � � � � � � � � � � � � � � � � � � 2

2 Technical Specifications � � � � � � � � � � � � 4

3 Safety Instructions � � � � � � � � � � � � � � � 6

4 Mounting Instructions � � � � � � � � � � � � � 8

5 Display Symbols � � � � � � � � � � � � � � � � 12

6 Configuring � � � � � � � � � � � � � � � � � � � 17

7 Settings � � � � � � � � � � � � � � � � � � � � � 17

8 Warranty� � � � � � � � � � � � � � � � � � � � � 20

9 Disposal Instruction � � � � � � � � � � � � � 21

Table of Contents

DEVIreg™ Smart

3Installation Guide

• A touchscreen display with light.

• An easy-to-follow menu-driven programming and operation.

• An installation wizard with room/floor type-specific setup (requires an app).

• Support for multiple frame systems.

• Compatible with several 3rd party NTC sensors.

• Thermostat settings can be specified before instal-lation and imported to the thermostat using a web-generated code, or copied from a thermostat in a similar installation.

• Smart access to thermostat settings after installa-tion by using a web code interface, for easy setup or remote troubleshooting.

Regarding Connectivity:

• 10 smart devices (like Smartphone or Tablet) can be connected to 1 thermostat.

• 2 smart devices can be in contact with the thermo-stat at the same time.

DEVIREG™ SMART REQUIRES WORKING WI-FI TO FUNCTION

DEVIreg™ Smart

Installation Guide4

More information on this product can also be found at: devismart�com

2 Technical Specifications

Operation voltage 220-240 V~, 50/60 Hz

Standby power consumption Max. 0,40 W

Relay:Resistive loadInductive load

Max. 16 A / 3680 W @ 230 VMax. 1 A cos φ= 0,3

Sensing units NTC 6,8 kOhm at 25°C NTC 10 kOhm at 25°C NTC 12 kOhm at 25°CNTC 15 kOhm at 25°C (Default) NTC 33 kOhm at 25°CNTC 47 kOhm at 25°C

Sensing values: (Default NTC 15 K)0°C20°C50°C

42 kOhm18 kOhm6 kOhm

Control PWM (Pulse Wide Modulation)

Ambient temperature 0° to +30°C

DEVIreg™ Smart

5Installation Guide

Frost protection temperature

5°C to +9°C (default 5°C)

Temperature range Room temperature: 5-35°C.Floor temperature: 5-45°C.Max. floor: 20-35°C (if unrecov-erable seal is broken then up to 45°C). Min. floor: 10-35°C, only with combination of room and floor sensor.

Sensor failure monitoring The thermostat has a built-in monitoring circuit, which will switch off the heating if the sensor is disconnected or short-circuited

Cable specification max. 1x4 mm2 or 2x2,5 mm2

Ball pressure test temperature 75°C

Pollution degree 2 (domestic use)

Controller type 1C

Software class A

Storage temperature -20°C to +65°C

IP class 21

DEVIreg™ Smart

Installation Guide6

Protection class Class II -

Dimensions 85 x 85 x 20-24 mm (in-wall depth: 22 mm)

Weight 127 g

Electrical safety and Electro-Magnetic Compatibility for this product is covered by the compliance with the EN/IEC Standard “Automatic electrical controls for household and similar use”:

• EN/IEC 60730-1 (general)

• EN/IEC 60730-2-9 (thermostat)

3 Safety Instructions

Make sure the mains supply to the thermostat is turned off before installation.

Important: When the thermostat is used to control a floor heating element in connection with a wooden floor or similar material, always use a floor sensor and never set the maximum floor temperature to more than 35°C.

DEVIreg™ Smart

7Installation Guide

Please also note the following:• The installation of the thermostat must be done by an

authorized and qualified installer according to local regulations.

• The thermostat must be connected to a power supply via an all-pole disconnection switch.

• Always connect the thermostat to continuous power supply.

• Do not expose the thermostat to moisture, water, dust, and excessive heat.

• This thermostat can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved, by a person responsible for their safety.

• Children should be supervised to ensure that they do not play with the thermostat.

• Cleaning and user maintenance shall not be made by children without supervision.

DEVIreg™ Smart

Installation Guide8

4 Mounting Instructions

Please observe the following placement guidelines:

Place the thermostat at a suitable height on the wall (typically 80-170 cm.).

The thermostat should not be placed in wet rooms. Thermostat must be placed outside zone 3. Place it in an adjacent room and use floor sensor only. Always place the thermostat according to local regulation on IP classes.

Do not place the thermostat on the inner side of a poorly insulated exterior wall.

Always install the thermostat at least 50 cm from windows and doors, due to draft, when using regu-lation in: floor and room mode or room alone mode.

Do not place the thermostat in a way that it will be exposed to direct sunlight.

DEVIreg™ Smart

9Installation Guide

Note: A floor sensor is recommended in all floor heating applications and mandatory to thin mats and under wooden floors to reduce the risk of over-heating the floor.

• Place the floor sensor in a protecting plastic conduit in the floor construction in an appropriate place, where the floor is not exposed to sunlight or draft from door openings.

• Equally distant and >2 cm from the heating cables on both sides.

• The conduit should be flush with the floor surface, countersink the conduit if neces-sary and possible.

• Route the conduit to the connection box.

• The bending radius of the conduit must be min 50 mm.

1 2

DEVIreg™ Smart

Installation Guide10

Follow the steps below to mount the thermostat:1. Unpack thermostat

2. Connect the thermostat according to the connection diagram. The screen of the heating cable must be connected to the earth conductor of the power supply cable by using a separate connector. Note: Always install the floor sensor in a conduit in the floor.

3. Fasten the thermostat firmly to a flush mounted wall box or an exterior wall box by driving the screws through the holes in each side of the thermostat.

4. Add the frame before assembling of top part to the snap locks/bot-tom part.

5. Click the front part module in place. Pay attention, in relation to

N

IP21T30

Dtouch

Mains220-240V50-60 Hz

MaximumLoad 16 (1) AS

enso

r

Standby maximum 0.4W

LLLOAD

NTC NLOAD

DEVIreg™ Smart

11Installation Guide

the female header, in not to bending the connectors. Press carefully until the frame is fixed against the rubber gasket.

When mounting and reassembling the thermostat.

Important: Do NOT press in the center of the display screen.

Press your fingers under the side of the front part and pull toward you until it releases from the snap lock:

To ensure that the batteries are fully charged, the ther-mostat shall be connected to main supply for minimum 15 hours. The current time and day is kept for 24 hours if mains supply is off. All other settings are stored permanently.

DEVIreg™ Smart

Installation Guide12

5 Display Symbols

Top part main functionalities are to support user interface through display and hold all the controller logic.

Display main functionalities are to show the current status of the Thermostat and recognize the user actions from the buttons. Display consists of different buttons, numbers and symbols.

1

4

2

3

DEVIreg™ Smart

13Installation Guide

Nr� Type Description

1 Button/Symbol Control button

2 Button/Symbol Arrow Up button

3 Button/Symbol Arrow Down button

4 Symbol 3 digit 7 segment numbers with comma separator

Symbol indications

Indication Mode/State Description

Blue - blinking Access Point Mode

Thermostat ready for set-up

Blue Access Point Mode

Smart phone connected directly to thermostat for set-up

Red - blinking Fault state Displays Error code

Red - slow pulsing

Active Mode Indicating heating the floor (Relay on)

Green - constant

Active Mode Thermostat active and con-nected to WiFi(Relay off)

DEVIreg™ Smart

Installation Guide14

Green – blinking

Active Mode & Access Point Mode

Thermostat waiting for confir-mation of action

Arrows – blinking rapidly when touched

Active Mode Safety lock is on

Interaction directly on thermostat

Function Button Description

Turn thermo-stat on

1. Touch any button 2. Touch control button (1)

Thermostat switch on and display temperature

Turn thermo-stat off

1. Touch any button 2. Touch and hold control button (1)

Thermostat display will turn on Thermostat count down and switch off

Adjust set-point

Up (2) Increases active mode/temporary set point

Down (3) Decreases active mode/temporary set point

DEVIreg™ Smart

15Installation Guide

Frost protec-tion

Touch and hold Control (1) for 1 sec.

Deactivate frost protec-tion

Safety lock Touch and hold Up (2) + Down (3) for 3 sec.

Activate/Deactivate safety lock

Factory restore Touch and hold Control (1) + Up (2) for 5 sec.After that touch Control (1) again to confirm

Activates factory restore state

Away mode Touch and hold Control (1) for 1 sec. to deactivate Away mode

Activate/Deactivate Away/Vacation mode

Error codes

When the error occurs and is resolved the thermostat, in some cases, will require a restart to start heating again.

DEVIreg™ Smart

Installation Guide16

Error type

Nr� Description Solu-tion

Need restart

Floor Sensor discon-nected

E1 Connection to sensor is lost

Contact service

The thermostat requires a restart to operate again.

Floor Sensor short-circuited

E2 Sensor short-circuited

Contact service

The thermostat requires a restart to operate again.

Ther-mostat over-heated

E3 Thermostat is over-heated, heating is turned off

Wait until ther-mostat cools down

The thermostat requires no restart, but will start heat-ing when the temperature is lowered

Unrecov-erable error

E4 Room temperature sensor value too high or too low

Contact service

The thermostat requires a restart to operate again.

DEVIreg™ Smart

17Installation Guide

6 Configuring

Download App Download the DEVIsmart™ app from App Store or Google Play or at devismart.com.

Open the DEVIsmart™ App Follow instructions and set-up flow in the App.

DEVIreg™ Smart indication The DEVIreg™ Smart shows “–” indicat-ing that power is ON, but still need to be configured.

7 Settings

IMPORTANT DURING SET-UP

Select whether only a floor sensor or a combination of room and floor sensor should be used.

A “room only” option is also available, but requires that you have to break the small plastic seal on the back of the

DEVIreg™ Smart

Installation Guide18

display module, e.g. using a screw-driver; it will be possible to set the maximum floor temperature up to 45°. Furthermore, it will be possible to use only a room sensor. However, this option is not recom-mendable due to an increased risk of overheating the floor.

IMPORTANT: When the ther-mostat is used to control a floor heating element in connection with a wooden floor or similar material, always use a floor sensor and never set the maximum floor temperature to more than 35°C.

DEVIreg™ Smart

19Installation Guide

Note: Please contact the floor supplier before changing the maximum floor temperature and be aware of the following:

• The floor temperature is measured there, where the sensor is placed.

• The temperature of the bottom of a wooden floor can be up to 10˚C higher than the top.

• Floor manufactures often specify the max. tempera-ture on the top surface of the floor.

Thermal resistance [m2K/ W]

Examples of flooring

Details kg/m3

Approximate setting for 25°C floor temperature

0,05 8 mm HDF based laminate

> 800 28°C

0,10 14 mm beech parquet

650 – 800 31°C

0,13 22 mm solid oak plank

> 800 32°C

DEVIreg™ Smart

Installation Guide20

< 0,17 Max. carpet thick-ness suitable for floor heating

acc. to EN 1307

34°C

0,18 22 mm solid fir planks

450 – 650 35°C

8 Warranty

The products will, in the event of a fault that can be tracked back to a manufacturing defect in the DEVI product, be repaired or replaced free of charge. To apply for this warranty the installation must be performed by an authorized installer and the warranty certificate has to be stamped, signed and provided. For more details read our warranty terms and conditions.

DEVIreg™ Smart

21Installation Guide

9 Disposal Instruction

DEVIreg™ Smart

Installation Guide22

DEVIreg™ Smart

23Installation Guide

DEVIreg™ Smart

Danfoss A/S Electric Heating Systems Ulvehavevej 61 7100 Vejle Denmark Phone: +45 7488 8500 Fax: +45 7488 8501 E-mail: [email protected] www.DEVI.com

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. DEVI and the DEVI logo-type are trademarks of Danfoss A/S. All rights reserved

Produced by Danfoss © 06/201608096265 & VDLUA102