installation guide · status. led will flash on and off once. the . cellular. led will flash but...

17
mIoT Captis Installation Guide May 2019 1 Rev 2.0 Installation Guide Captis Metrum & Itron TD8

Upload: others

Post on 13-Jan-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Installation Guide · STATUS. LED will flash on and off once. The . CELLULAR. LED will flash but should stabilise to a solid orange light within 2 minutes. If the . STATUS. LED does

mIoT Captis Installation Guide May 2019

1 Rev 2.0

Installation Guide Captis Metrum & Itron TD8

Page 2: Installation Guide · STATUS. LED will flash on and off once. The . CELLULAR. LED will flash but should stabilise to a solid orange light within 2 minutes. If the . STATUS. LED does

mIoT Captis Installation Guide May 2019

2 Rev 2.0

Contents

Introduction.............................................................................................................................................. 3 Captis Technical Information................................................................................................................... 3

Captis Metrum ..................................................................................................................................... 3 Installation ............................................................................................................................................... 4

Before you begin ................................................................................................................................. 4

What is in the Captis Box? .................................................................................................................. 4 Installing the Captis ................................................................................................................................. 5

Terminating the device ............................................................................................................................ 5

Mounting the Captis ............................................................................................................................ 6 Register and configure the Captis ....................................................................................................... 8

Connection Tests .......................................................................................................................... 15 Troubleshooting .................................................................................................................................... 16

Servicing................................................................................................................................................ 17

Battery Replacement ......................................................................................................................... 17 Safety .................................................................................................................................................... 17

Electromagnetic Radiation – Human Exposure ................................................................................ 17

Page 3: Installation Guide · STATUS. LED will flash on and off once. The . CELLULAR. LED will flash but should stabilise to a solid orange light within 2 minutes. If the . STATUS. LED does

mIoT Captis Installation Guide May 2019

3 Rev 2.0

INTRODUCTION

The Captis cellular data logger has been developed to fill measurement requirements across a broad range of applications and remote locations.

The Captis Metrum has the following features:

• The device measures 90 x 75 x 50 mm and weighs less than 500g.

• Is designed to interface with existing mechanical water meter via a pulse pick up unit.

• It is battery operated and does not require an external power supply.

• It operates on LTE-M or NB-IoT cellular networks.

• The enclosure is IP68 rated.

CAPTIS TECHNICAL INFORMATION

CAPTIS METRUM

1x Pulse Input Passive Suitable for Reed SW + Open Collector + Dry Contact

Maximum Frequency 500Hz

Sensor Minimum Open Resistance 1.25MΩ

Sensor Maximum Closed Resistance 60kΩ

Physical Size 90mm x 75mm x 50mm

Weight Less than 500g

IP Rating IP68

Figure 1 Captis dimensions front view Figure 2 Captis dimensions top view

Page 4: Installation Guide · STATUS. LED will flash on and off once. The . CELLULAR. LED will flash but should stabilise to a solid orange light within 2 minutes. If the . STATUS. LED does

mIoT Captis Installation Guide May 2019

4 Rev 2.0

INSTALLATION

BEFORE YOU BEGIN

Before starting this installation, you will need the following items:

• The contents of the Captis box. • The water meter that will be connected to the Captis • A 3mm Allen key and small flat blade screwdriver • An internet-connected device, such as a phone or tablet.

WHAT IS IN THE CAPTIS BOX?

In the Captis box you will find:

• Captis data logger

• Cable Cover

• Attachment Band and screw

• Activation Magnet Used to wake up and reset the device.

Figure 4 Captis showing magnet being used to wake device

Page 5: Installation Guide · STATUS. LED will flash on and off once. The . CELLULAR. LED will flash but should stabilise to a solid orange light within 2 minutes. If the . STATUS. LED does

mIoT Captis Installation Guide May 2019

5 Rev 2.0

INSTALLING THE CAPTIS

Asses installation site for accessibility

Attach the Captis to the water meter

Register the Captis device to

the Cloud Platform

Test sensor connection and data

transmission

Complete installation

Figure 5 Steps to install the Captis

To successfully install the Captis you must perform the following steps. Each step is described in more detail in the following sections.

1. Mount the Captis Metrum to the Itron TD8 water meter 2. Register the Captis on the cloud platform. 3. Test the wiring, sensor and cellular connection. 4. Complete the physical installation after testing.

TERMINATING THE DEVICE The Itron TD8 Cyble Sensor comes prewired to the Captis Metrum Device. The Cyble Sensor is connected using the below Cable Colours.

Colour Description Metrum Pulse – (Black) Itron Pulse Detection Metrum Pulse + (White) Itron Pulse Detection

Page 6: Installation Guide · STATUS. LED will flash on and off once. The . CELLULAR. LED will flash but should stabilise to a solid orange light within 2 minutes. If the . STATUS. LED does

mIoT Captis Installation Guide May 2019

6 Rev 2.0

MOUNTING THE CAPTIS

The Captis Metrum is designed to seamlessly integrate with Itron’s TD8 water meter, and can be simply installed following these steps:

1. Pass the supplied mounting band around the TD8 and secure with the supplied screw and a 3mm Allen Key.

2. Carefully install the Cyble Sensor - attached to the Metrum Device - on the top of the Itron TD8 meter as shown.

3. Clip the Metrum housing onto the Band.

Continued over the next page …

Page 7: Installation Guide · STATUS. LED will flash on and off once. The . CELLULAR. LED will flash but should stabilise to a solid orange light within 2 minutes. If the . STATUS. LED does

mIoT Captis Installation Guide May 2019

7 Rev 2.0

4. Place the supplied Cable cover over the pickup and Metrum cable entry and clip into the attachment band to secure

5. Screw the Cyble Sensor to the Itron TD8 water meter using the white plastic screw enclosed, and cover with the accompanying blue cap.

Page 8: Installation Guide · STATUS. LED will flash on and off once. The . CELLULAR. LED will flash but should stabilise to a solid orange light within 2 minutes. If the . STATUS. LED does

mIoT Captis Installation Guide May 2019

8 Rev 2.0

REGISTER AND CONFIGURE THE CAPTIS

Before registering the Captis, you must:

• Connect the Captis device to the water meter

1. Login to the Cumulocity cloud platform using an internet connected device such as a tablet or mobile phone.

2. Create the Captis device in the Cumulocity system by entering the serial number found on the label of the device you are installing.

a. Go to the Devices menu. Click Registration then click Register Device. b. Click General Device Registration.

Figure 6 Registering the Captis overview

Note: The Captis device does not have to be installed in its final location before registration. If the device’s final location is difficult to reach, you can perform all the registration and some of the testing before installing it.

Page 9: Installation Guide · STATUS. LED will flash on and off once. The . CELLULAR. LED will flash but should stabilise to a solid orange light within 2 minutes. If the . STATUS. LED does

mIoT Captis Installation Guide May 2019

9 Rev 2.0

c. Enter the serial number from the label of the Captis.

d. If this device is part of a group, select that group from the drop-down menu. e. Click Next to register the device.

3. A magnet is provided with the Captis. Place the magnet between the two LEDs on the label

for 3-5 seconds. The device will wake up and attempt to connect to the network.

4. Check the STATUS and CELLULAR LEDs to confirm that the device is powered, and a network connection has been established. The STATUS LED will flash on and off once. The CELLULAR LED will flash but should stabilise to a solid orange light within 2 minutes.

If the STATUS LED does not flash, re-try the magnet between the LEDs. If this still does not work, see Troubleshooting for more suggestions.

If the CELLULAR LED does not stop flashing within 2 minutes, this indicates connection issues and/or poor signal strength. If an external antenna is used, reposition it to a more open location away from metal objects. If an internal antenna is used, see if the device can be mounted in another location.

Hold the magnet between the LEDs once again to wake-up the device and inspect the CELLULAR LED.

See Troubleshooting for more information if you are still having problems.

Both lights will go out when transmission is completed.

Page 10: Installation Guide · STATUS. LED will flash on and off once. The . CELLULAR. LED will flash but should stabilise to a solid orange light within 2 minutes. If the . STATUS. LED does

mIoT Captis Installation Guide May 2019

10 Rev 2.0

5. Go to the Cumulocity cloud platform and accept the device. a. Go to the Device Registration Page. b. Find your device in the list on the Device Registration Page. Its status should be

Pending Acceptance.

c. Click Accept.

6. Wake up the device again, using the magnet between the two LEDs. This will download credentials from the cloud.

7. On the cloud platform, select your device from the list. a. Click on the App Menu in the top right hand corner, and then click on Captis.

b. You will see the Captis sub-menu.

Page 11: Installation Guide · STATUS. LED will flash on and off once. The . CELLULAR. LED will flash but should stabilise to a solid orange light within 2 minutes. If the . STATUS. LED does

mIoT Captis Installation Guide May 2019

11 Rev 2.0

c. Select Captis Configuration from the Captis sub-menu.

8. Configure the device to suit your requirements in the Sensor Tab.

Page 12: Installation Guide · STATUS. LED will flash on and off once. The . CELLULAR. LED will flash but should stabilise to a solid orange light within 2 minutes. If the . STATUS. LED does

mIoT Captis Installation Guide May 2019

12 Rev 2.0

Digital In 1

Enable Enable function of the Switch Input. If Cable Cut Detection is required, this should be left as Enable

Type This is for the Type of the input, either Pulse or Switch. Since the Metrum is shipped pre wired, Digital In 1 should be left as Pulse.

Pulse Scale Factor This is the K Factor of the Meter (how many L per Pulse) e.g. 2 Pulse per L would be 0.5 (in the Pulse Scale Factor) and 5 Pulses per L would be 5 (in the Pulse Scaling factor.

Pulse Units The unit of measurement that will be Displayed in Cumulocity, generally this is set to Litres or L

Offset The current meter reading should be entered here

Flash LED This feature allows the Status LED to flash when a Pulse is received

Digital In 2

Enable Enable function of the Switch Input. If Cable Cut Detection is required, this should be left as Enable

Type This is for the Type of the input, either Pulse or Switch. Since the Metrum is shipped prewired, Digital In 2 should be left as Switch.

Flash LED This feature allows the Status LED to flash when a Switch is received

Page 13: Installation Guide · STATUS. LED will flash on and off once. The . CELLULAR. LED will flash but should stabilise to a solid orange light within 2 minutes. If the . STATUS. LED does

mIoT Captis Installation Guide May 2019

13 Rev 2.0

9. If Required, an Alarm can be set up if the Pickup Cable has been cut or damaged. Under the

Alarm Tab, there is the ability to set up various alarms.

For the Switch Input:

- Switch should be selected from the Sensor Type - Sensor Channel is 2 - Setpoint 0 (Open Circuit) - Hysteresis of 0 - Trigger set to Equal To

continued over page...

Page 14: Installation Guide · STATUS. LED will flash on and off once. The . CELLULAR. LED will flash but should stabilise to a solid orange light within 2 minutes. If the . STATUS. LED does

mIoT Captis Installation Guide May 2019

14 Rev 2.0

In the Action List, it is preferable to use the Email (with the email address to be input into the ‘Email’ section directly above these settings) and the Send Logged actions for the Metrum.

10. Once the Setup has been completed, simply press Save and the operation will be saved under the Control Tab.

11. Wake up the device, using the magnet. This will download the Configuration from Cumulocity.

Page 15: Installation Guide · STATUS. LED will flash on and off once. The . CELLULAR. LED will flash but should stabilise to a solid orange light within 2 minutes. If the . STATUS. LED does

mIoT Captis Installation Guide May 2019

15 Rev 2.0

Testing the Captis

The final steps in registering the Captis are to confirm that the sensors are working, and the cellular signal is adequate.

To test the Captis before you install it, you must:

1. Perform the Connection tests to make sure the sensor is wired correctly, and that the data is transmitted to Cumulocity.

2. Install the device. 3. Perform the Connection tests again to make sure the final

location has adequate signal for data transmission.

If the installation location of the Captis is easy to reach:

1. Install the device. 2. Perform the Connection tests.

CONNECTION TESTS

Check that the connection between the device and the sensor is functional and that there is adequate cellular signal for the Captis to work as required.

1. Activate your sensor to create a few recordable events. How you do this will depend on the sensor.

2. Wake up the Captis using the magnet. The device will then transmit the recorded data to the cloud platform.

3. Find the device you are testing on the cloud platform. Check that the data has been transmitted, it is accurate, and no alarms have been recorded.

a. Go to App Menu > Captis. b. Click on the device you are testing. c. Select Measurements

If the data has been submitted correctly, the registration and installation are a success. If the data does not appear, see the Troubleshooting section below.

Note: If the installation location of the Captis is difficult to reach, you can perform the sensor connection and data transmission tests before you install the device in its final location. This makes it easier to fix any wiring or connection issues

Page 16: Installation Guide · STATUS. LED will flash on and off once. The . CELLULAR. LED will flash but should stabilise to a solid orange light within 2 minutes. If the . STATUS. LED does

mIoT Captis Installation Guide May 2019

16 Rev 2.0

TROUBLESHOOTING

Symptom Meaning What to do

Status LED flashing then solid Device is on/ awake Device is working as it should, leave device to collect data

Cellular LED flashing then solid Device connected to LTE network

Device is working as it should, leave device to collect data

Status LED won’t turn on after using the magnet

The device battery may be depleted, or a device fault may have occurred

Use a different device and contact the supplier

Cellular LED flashing for more than 2 minutes

Signal is obstructed Ensure there are minimal physical and metallic obstructions between the device and the signal

Contact the supplier if issue persists

Site has very low or no network coverage and not suitable for installation

Alternate flashing between Cellular LED and Status LED

No Cellular registration (connection to the network) is being achieved.

Check with the Telstra coverage map to ensure the site is covered.

If the area is covered, use a different device and contact the supplier.

Sensor connection not working (not flashing the LED after LED flash turned on in Captis Configuration Toolset)

Connection wired incorrectly

Confirm that the Itron TD8 Cyble Sensor is properly attached to the Itron TD8

Contact support if issue persists

Sensor readings not uploading to/ appearing in Cumulocity

Sensor not triggering

Ensure the sensor can be triggered by checking that the Itron TD8 Cyble Sensor is securely installed in the meter.

Contact support if issue persists

No cellular signal

Check Status and Cellular LED.

If flashing, complete troubleshooting for a flashing Cellular LED.

Contact support if issue persists

Page 17: Installation Guide · STATUS. LED will flash on and off once. The . CELLULAR. LED will flash but should stabilise to a solid orange light within 2 minutes. If the . STATUS. LED does

mIoT Captis Installation Guide May 2019

17 Rev 2.0

SERVICING

BATTERY REPLACEMENT

The battery should only be replaced with a Captis approved battery. Other types of battery will either not provide enough power to function properly or cause damage to the device and/or battery and/or user. Warranty becomes void when a non-approved battery is used.

CAUTION: RISK OF FIRE OR EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE

Please go to http://recyclingnearyou.com.au/batteries to find a location for recycling the spent battery. The battery type is single use lithium-thionyl chloride (Li-SOCl2).

SAFETY

ELECTROMAGNETIC RADIATION – HUMAN EXPOSURE

Warning: This device has a Maximum Permissible Exposure (MPE) radius of 20cm.

It is the installer’s and end customer’s responsibility to ensure that no person has any body parts within 20cm of the device or antenna while device is transmitting. Device is transmitting when the ‘Cellular’ LED is lit.

NOTE: Lithium batteries are considered dangerous goods for transportation purposes regardless of the state of charge.