Page 1: Installation Manual ClimaCLEAR - NanaWall · 800 873 5673 415 383 3148 Fax 415 383 0312 info@nanawall.com nanawall.com ©2020 Nana Wall Systems, Inc r09.2020 Installation Manual ClimaCLEAR

Nana Wall Systems, Inc.

100 Meadowcreek Drive #250

Corte Madera, CA 94925

800 873 5673

415 383 3148

Fax 415 383 0312

[email protected] nanawall.com

©2020 Nana Wall Systems, Incr09.2020

Installation Manual ClimaCLEARSingle Track Sliding Frameless System

Page 2: Installation Manual ClimaCLEAR - NanaWall · 800 873 5673 415 383 3148 Fax 415 383 0312 info@nanawall.com nanawall.com ©2020 Nana Wall Systems, Inc r09.2020 Installation Manual ClimaCLEAR

Level at least 6'0"

516 "

8Drill

1 14 "

32

Core Drill Bitfor Pivot Point

Crowbar Soft Face Hammer

1"25

Core Drill Bitfor Eccentric Floor Socket

2,5mm allen wrench

3mm allen wrench

4mm allen wrench

5mm allen wrench

6mm allen wrench

Metric Tape Measure

2mm allen wrench

Sheet

Required Tools1. Rough Opening and Unit Dimensions2. Head Track in "kd" (knocked down) Condition3. Head Track and Sill Connectors for Side Jambs 4. Assembly of Head Track 5. Head Track Shimming6. Installation Sequence of Panels7. Panel Alignment and Height Adjustment8. Single Action Offset End Panel Adjustment9. Typical weeping at low profile saddle sill ("LPSS") by others10. Drilling Weep Holes and Cutting to Size Inserts Between Adjustable Floor Sockets11. Offset Pivot Point and Top Door Closer for Single Action Offset End Panel12. Field Applying Vertical H- and h-gaskets13. Installation of Mortise Cylinder14.

REQUIRED TOOLSTable of ContentsRev. October 9 2020

NanaWall Product Drawing

Wrench22mm

Wrench19mm

Wrench17mm

Wrench11mm

Wrench10mm

Metric Tools Supplied in Accessory Box

Installation ManualSHEET 1 OF 14ClimaCLEAR

Page 3: Installation Manual ClimaCLEAR - NanaWall · 800 873 5673 415 383 3148 Fax 415 383 0312 info@nanawall.com nanawall.com ©2020 Nana Wall Systems, Inc r09.2020 Installation Manual ClimaCLEAR

#1 #2 #3

34 "19

12 "13

34 "19

12 "13

shim space

14 "7

Brush

Sill

Panel

FF

Rough Opening Dimensions- after applying all deadloads max. deflection of header the lesser of L/720 or 1/4"- the weight of a panel with 1/2" glass is 8 lbs/sqft

Unit Dimensions- leave enough shim space to surrounding condition

SHEET 2 OF 14Installation ManualClimaCLEAR

Page 4: Installation Manual ClimaCLEAR - NanaWall · 800 873 5673 415 383 3148 Fax 415 383 0312 info@nanawall.com nanawall.com ©2020 Nana Wall Systems, Inc r09.2020 Installation Manual ClimaCLEAR

12 "13

38 "9

AD

AE

9 13

16 "250

9 1316 "

250 9 13

16 "250

ER

12 "13

38 "9

14 "6

recommendednot recommended

[2"]50

[2"]50

9 13

16 "250

9 1316 "

250 9 13

16 "250

Top Track Comes Pre-Drilled

Head Track in "kd" (knocked down) Condition

NanaWall does not provide nor take responsibility for sizes, location or frequency of perimeter fasteners.

optional byNanaWall

IF YOU WANT TO RECESS THE HEAD TRACK INTO THE CEILING, WE RECOMMEND TO LEAVE 1/4" (6MM) VISIBLE TO AVOID SCRUB MARKS FROM THE TOP BRUSH SEALS IN THE AREA OF THESWING PANEL, STACKING BAYS AND 90° CORNER TURNS.

SHEET 3 OF 14Installation ManualClimaCLEAR

Page 5: Installation Manual ClimaCLEAR - NanaWall · 800 873 5673 415 383 3148 Fax 415 383 0312 info@nanawall.com nanawall.com ©2020 Nana Wall Systems, Inc r09.2020 Installation Manual ClimaCLEAR

JA

JB

Top Connector Piece (Side Jambs and Head Track)

Bottom Connector Piece (Side Jambs and Low Profile Saddle Sill)

2.25 3.75

3

INTERIOR EXTERIOR1/4" x 1" WEEP SLOTS ATABOUT THE CENTER OF EACHPANEL ACROSS THE LENGTHOF THE SILL

INSTALLER NOTE:L.P.S.S IS NOT CENTERED

ON THE UNIT

1/4" x 1" WEEP SLOTS ABOUT 10" FROM EACH ENDAND ABOUT EVERYWEEPING POINT OF PANELSACROSS THE LENGTH OF THE SILL. MOVE SLOT LOCATIONSAS NEEDED SO THEY ARESTAGGERED AT LEAST 8"AWAY FROM THE WEEP SLOTSIN THE INNER CHANNEL

FFHFFH

1/4" x 1" WEEP SLOTS INTHE INNER CHANNEL ATABOUT THE CENTER OF EACHPANEL ACROSS THE LENGTHOF THE SILL

FFHFFH

1/4" x 1" WEEP SLOTS INTHE INNER CHANNEL ATABOUT THE CENTER OF EACHPANEL ACROSS THE LENGTHOF THE SILL

INSTALLER NOTE:L.P.S.S IS NOT CENTERED

ON THE UNIT

1/4" x 1" WEEP SLOTS ABOUT 10" FROM EACH ENDAND ABOUT EVERYWEEPING POINT OF PANELSACROSS THE LENGTH OF THE SILL. MOVE SLOT LOCATIONSAS NEEDED SO THEY ARESTAGGERED AT LEAST 8"AWAY FROM THE WEEP SLOTSIN THE INNER CHANNEL

1/4" x 1" WEEP SLOTS ATABOUT THE CENTER OF EACHPANEL ACROSS THE LENGTHOF THE SILL

EXTERIORINTERIOR

Head Track and Sill Connectors for Side Jambs

plus Weep Slot Pattern for Bottom Track

SHEET 4 OF 14Installation ManualClimaCLEAR

Page 6: Installation Manual ClimaCLEAR - NanaWall · 800 873 5673 415 383 3148 Fax 415 383 0312 info@nanawall.com nanawall.com ©2020 Nana Wall Systems, Inc r09.2020 Installation Manual ClimaCLEAR

B

B

A

B

B

B

B A

B A

A

B

B

B

B

B

RHTRemovableHeadTrack

M

P

P

R

2x

2x

AF

FG

2x

2x

DETAIL HTSCALE 1 : 4

Stopper

JA

JB

HY

Assembly of Head Track

SupportStructure by others

Suggested Side Jamb Fastening Points:A - about 4" from interior edgeB - single action offset end panel side; approx. distance every 16" from the bottom using one extra screw at the bottom

SHEET 5 OF 14Installation ManualClimaCLEAR

Page 7: Installation Manual ClimaCLEAR - NanaWall · 800 873 5673 415 383 3148 Fax 415 383 0312 info@nanawall.com nanawall.com ©2020 Nana Wall Systems, Inc r09.2020 Installation Manual ClimaCLEAR

W

AA

AC

Finished Floor to Bottom of Head-Track Height

FFL

Head Track Shimming

SHEET 6 OF 14Installation ManualClimaCLEAR

Page 8: Installation Manual ClimaCLEAR - NanaWall · 800 873 5673 415 383 3148 Fax 415 383 0312 info@nanawall.com nanawall.com ©2020 Nana Wall Systems, Inc r09.2020 Installation Manual ClimaCLEAR

Panel #1 Panel #2 Step 2 Step 1

Installation Sequence of Panels

RHT(Sheet 5)

Panel#2

Panel#2

SCALE 1 : 16

Panel#1

Shown on Top of the Elevation of Product Drawing

RHT(Sheet 5)

Step 0 Step 1 Step 2 Step 3 Panel Installation Sequence

Rollers are supplied lose in theaccessory box and need to beinstalled in the field Attention: don't install set screw until roller is finally adjusted in height.

SHEET 7 OF 14Installation ManualClimaCLEAR

Page 9: Installation Manual ClimaCLEAR - NanaWall · 800 873 5673 415 383 3148 Fax 415 383 0312 info@nanawall.com nanawall.com ©2020 Nana Wall Systems, Inc r09.2020 Installation Manual ClimaCLEAR

BF

Set screw to secureaxle from turning

532 "4

532 "4

BG

CL

#1 #2

14 "7

HT

HWHW

SECTION HW-HWSCALE 1 : 24

Panel Alignment and Height Adjustment

Don't Drill Holes for Sockets, yet !

FFL

SHEET 8 OF 14Installation ManualClimaCLEAR

Page 10: Installation Manual ClimaCLEAR - NanaWall · 800 873 5673 415 383 3148 Fax 415 383 0312 info@nanawall.com nanawall.com ©2020 Nana Wall Systems, Inc r09.2020 Installation Manual ClimaCLEAR

#1 #2 #3 must fit

HTHT

SECTION HT-HTSCALE 1 : 16

Single Action Offset End Panel Adjustment

SHEET 9 OF 14Installation ManualClimaCLEAR

Page 11: Installation Manual ClimaCLEAR - NanaWall · 800 873 5673 415 383 3148 Fax 415 383 0312 info@nanawall.com nanawall.com ©2020 Nana Wall Systems, Inc r09.2020 Installation Manual ClimaCLEAR

516 "

8

38 "

10

38 "

10

minimum of

14 "6 recommended shim space

B B

A

6"152 at least

10"254

or centerof panel

A A A ABBB

Typical weeping at low profile saddle sill ("LPSS") by others(for some resistance against wind driven rain)

Note:All appropriate water proofing and flashing details to be designed and installed by others.These should include proper sealingof all punctured holes and screws

SHEET 10 OF 14Installation ManualClimaCLEAR

Page 12: Installation Manual ClimaCLEAR - NanaWall · 800 873 5673 415 383 3148 Fax 415 383 0312 info@nanawall.com nanawall.com ©2020 Nana Wall Systems, Inc r09.2020 Installation Manual ClimaCLEAR

14 "

6

14 "

6

DETAIL HWSCALE 1 : 1

Cutting to Size Inserts Between Adjustable Floor Sockets

Drilling Weep Holes and Cutting to Size Inserts Between Adjustable Floor Sockets

3x weep holes oneach side equally spaced per panel

SHEET 11 OF 14Installation ManualClimaCLEAR

Page 13: Installation Manual ClimaCLEAR - NanaWall · 800 873 5673 415 383 3148 Fax 415 383 0312 info@nanawall.com nanawall.com ©2020 Nana Wall Systems, Inc r09.2020 Installation Manual ClimaCLEAR

#3

HH

2 58 "66

3 116 "79

1 116 "28

HU

HV

HWHW

HT

Set screw to secureaxle from turning

Panel Heightadjustment

1'2 18 "358

4 18 "105

2"51

2 58 "66

Wall

1'1 716 "341

2 18 "54

3 116 "78

2 38 "60

Offset Pivot Point and Top Door Closer for Single Action Offset End Panel

SHEET 12 OF 14Installation ManualClimaCLEAR

Page 14: Installation Manual ClimaCLEAR - NanaWall · 800 873 5673 415 383 3148 Fax 415 383 0312 info@nanawall.com nanawall.com ©2020 Nana Wall Systems, Inc r09.2020 Installation Manual ClimaCLEAR

Please cut to size the vertical clear gaskets in the field;top and bottom should exceed the top and bottom edge of the end cover by approximately 1/8"

H-gasket (between sliding panels) and

h-gasket (on the side of the sliding panel meeting the single action end panel with offset hinge)

Step 1

Field Applying Vertical H- and h-gaskets

SHEET 13 OF 14Installation ManualClimaCLEAR

Page 15: Installation Manual ClimaCLEAR - NanaWall · 800 873 5673 415 383 3148 Fax 415 383 0312 info@nanawall.com nanawall.com ©2020 Nana Wall Systems, Inc r09.2020 Installation Manual ClimaCLEAR

HU

DETAIL HU

5/64" forset screw

allen wrenchfor set screw ofMortise cylinder

Installation of Mortise Cylinder

SHEET 14 OF 14Installation ManualClimaCLEAR