installation operation maintenance troubleshooting cuspidor manual.pdf · bowl assembly / post...
TRANSCRIPT
Installation Operation Maintenance Troubleshooting Version 1, Oct/09
1655 Palm Beach
Summit Dental Systems
1
Congratulations!
All of us at Summit Dental Systems want you to know that your 1655 Palm Beach Cuspidor has been built with the finest materials available.
The assembly and testing was completed by technicians devoted to making SDS products perform to all prescribed specifications.
Our five year limited warranty is just one of the ways we express our confidence that you will be completely satisfied with your purchase.
We appreciate your support and look forward to meeting your future professional needs through our expanding product line.
Cesar Coral President
Summit Dental Systems
2
Table of Contents
Important Information 3
Weights & Dimensions 5
Operator’s Instructions 6
Cleaning Your Cuspidor 7
Post Leveling 8
Installation Instructions 9
Junction Box Plumbing Layout 12
Cuspidor Umbilical Connections 13
Post Mount Unit And Cuspidor Utility Box Connections 13
Junction Box Connections For Post Mount Unit 13
Foot Control Connections 13
Umbilical Entering Tray Head 14
Utility Center Tubing Diagram 15
Flow Diagram & Parts – Box Assembly 16
Flow Diagram & Parts – Housing Assembly 17
Troubleshooting Guide 18
Part List 19
Cuspidor Assembly 20
Bowl Assembly / Post Mounted Box Assembly 21
Warranty 22
Summit Dental Systems
3
Important Information
Technical Specifications Factory Pre-set Air Regulator Pressure: 80 PSI Factory Pre-set Water Regulator Pressure: 40 PSI Handpiece Pressure: 30-35 PSI (for most high-speed handpieces) 40-45 PSI (for most low-speed handpieces) Unpacking
Pay careful attention when unpacking the cuspidor and its accessories. Damage caused by mishandling the equipment during unpacking or installation is not covered under warranty.
New Owner
Please read, sign and submit the warranty registration form that is located at the end of this manual. Failure to return this form may void the warranty.
Serial Number
Record this serial number in a convenient location. You will be asked for this number when requesting service or warranty information. (see drawing on next page for location of label).
Warning
Medical Electrical Equipment needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in this manual. Portable and mobile RF communications equipment can affect Medical Electrical Equipment.
Attention
CE-mark
Manufacturer and Date of manufacture Serial Number
Attention, consult
accompanying operation instructions.
SUMMIT DENTAL SYSTEMS Ft, Lauderdale, FL USA
MODEL No: SERIAL No: PRODUCT: VOLTS HERTZ AMPS
Summit Dental Systems
4
European Authorized Representative
MT Promedt Consulting GmbH Altenhofstrasse 80 D-66386 St. Ingbert, Germany Phone: +49 (0)6894-581020 Fax: +49 (0)6894-581021
Questions?
Read this manual carefully. If you have any questions, please call Summit Dental Systems Technical Service at 1-800.275.3368 (USA) or (954) 730-3636 (Outside USA).
CAUTION When adjusting the bowl rinse or cup fill flow control valves, do not over tighten the screws. This may result in unnecessary damage to the tubing.
CAUTION Do not attempt to over extend the breakaway assembly. Over extension to the breakaway assembly may cause unnecessary damage to the cuspidor.
!
!
Product Label Location The product label can be located behind the post mounted utility box cover.
SUMMIT DENTAL SYSTEMS Ft, Lauderdale, FL USA
MODEL No: SERIAL No: PRODUCT: VOLTS HERTZ AMPS
Summit Dental Systems
5
Weight & Dimensions Shipping Information
General Dimensions
Shipping Weight: 54 lbs/24.49mm
13”/330.2mm
23.5”/596.9mm
35.27” / 896mm
6.11” 155.2mm
39”/990.6mm
8.89” 225.7mm
Summit Dental Systems
6
Operator’s Instructions
A. Automatic Cup Fill Control • Press and release cup fill button. The Cup Fill will automatically turn off
B. Timed Bowl Rinse • Press and release bowl rinse button. The Bowl Rinse will automatically turn off
C. Solids Collector • Move cuspidor to access collection screen for disposal
D. City/Bottle Switch • Alternate from city or bottled water
E. Water Bottle Switch • Pressurizes the self-contained water bottle system
F. Air Quick Disconnect • Air supply to accessories
G. Water Quick Disconnect • Water supply to accessories
H. Cup Fill Level Control • Adjusts the water level in the cup fill.
I. Bowl Rinse Time Control • Adjusts the amount of time water flow in the bowl rinse.
J. Bowl Rinse Pressure Control • Pinch valve on tubing. Controls amount of pressure at rinse nozzle.
H. Cup Fill Pressure Control • Pinch valve on tubing. Controls water pressure from cup filler spout
Summit Dental Systems
7
Cleaning Your Cuspidor
Daily Maintenance At the end of every day.
1. Remove bowl screen from the cuspidor bowl and clean or discard (bio-hazard). 2. Raise the chair to its highest position and activate the bowl rinse several times, long
enough for the water to flow down the drain for approximately 60 seconds. 3. This will help prevent clogs in the drain line.
CAUTION
3. Remove the solids collector screen and discard.
CAUTION 4. Your cuspidor is designed for quick and easy cleaning. The smooth surfaces,
removable porcelain bowl and contoured spouts help facilitate more complete cleaning.
Bio-Hazard – use gloves mask and goggles.
Do not empty the bowl screen into the cuspidor. This can clog the cuspidor drain.
!
!
Solids Collector
Porcelain Bowl
Contoured Spouts
Bowl Screen
Summit Dental Systems
8
Post Leveling
1. Install the post with the bushing at the top; be certain that the post bottoms in the
post socket ad that the hole in the side of the post is facing toward the head of the chair. Look at the post socket and locate the eight leveling screws (see figure above).
2. Place a 6 to 12 inch level in the upright post (a magnetic level works best). While holding the post as upright as possible, tighten the upper four leveling screws until they just contact the post on all four sides. Position the level so that it is in line with the front to back level screws.
3. Level the post front to back. Now move the level 90 degrees and repeat the above procedure with the remaining screws for leveling side to side. Re-check level in both directions, and then fully tighten all leveling screws.
4. To ensure that the unit is absolutely level, it will be necessary to level the base unit on the post once the post has been leveled.
Summit Dental Systems
9
Installation Instructions
Cup Fill & Bowl Rinse Spouts
HVE & SE Hangers
Porcelain Bowl
1. Lay cuspidor down on soft surface to prevent scratching outer cover. 2. Remove magnetic cover to expose mounting screws. 3. Insert light post into center hole of cuspidor until 4 ¼” of post protrudes out from bottom of cuspidor.
4 - ¼” Socket Set
Cover
Drain Channel Assembly
Solids Canister
Stop Pin 5o Clock
12o Clock6o Clock
4 ¼”
Summit Dental Systems
10
4. Tighten the two lowest ¼” socket head screws making sure that the stop pin is at 5o clock position when cuspidor is at 12+6o clock position when mounted on chair. This position will stop the horizontal arm of the Palm Beach light at 6o clock. 5. Lift the entire assembly and put light post bottom into chair mounting bracket and level. 6. Once level, adjust the cuspidor to the desired height and tighten all 4 socket head screws. 7. Attach the porcelain bowl to the bowl socket by slowly pressing down. This will allow the cuspidor to properly set in the bowl socket. 8. Coat O-ring on cup fill and bowl flush spouts with O-ring lube before inserting them into their respective sockets. If these spouts are removed for periodic cleaning, re-coat with O-ring lube as necessary. 9. Insert the Cup Fill & Bowl Spouts in to their respected sockets, with the rubber gray seals underneath the bowl and flush against the sockets. 10. Attach the HVE and Saliva Ejector tubing in their corresponding sockets of the solids canister and place valves in hangers.
Adjust Bowls Rinse Water Flow 1. Test water flow around bowl 2. If needed put small round instrument in hole and rotate to
get desired water flow around bow.
Summit Dental Systems
11
Test Bowl Rinse 1. Activate bowl rinse. 2. If bowl does not rinse long enough adjust 3-way bleed valve clockwise 3. If rinses to short turn 3-way bleed valve counter-clockwise Test Cup Fill 1. Activate cup fill. 2. If bowl does not fill enough adjust 3-way bleed valve clockwise 3. If cup fills too much turn 3-way bleed valve counter-clockwise
Summit Dental Systems
12
Junction Box Plumbing Layout Not to Scale
Summit Dental Systems
13
Cuspidor Umbilical Connections
White 1/8” - spare Red 1/8” – from air filter housing to in port on master switch Yellow 1/8” – signal air from master switch to air operated solenoids in Junction Box Orange 1/4” – drive air to unit Blue ¼” C – regulated and filtered water supply to cup filler relay valve in cuspidor Blue ¼” B – regulated non-filtered water to bowl flush solenoid in cuspidor Clear Blue 1/8” – to city water toggle valve in cuspidor
Post Mount Unit and Cuspidor Utility Box Connections FROM PALM BEACH UNIT ARM
1/8” red – master valve 1/8” yellow – pilot air to unit 1/4” orange – drive air 1/8” pink – bio filter air, purge, syringe 1/8” blue – water to unit 1/8” orange – air coolant 1/8” green – purge 1/8” clear – handpiece valves, remote bowl and cup fill valves, biofilter 1/8” white – spare
Junction Box Connections for Post Mount Unit
1/8” red to master 1/8” yellow pilot air to unit ¼” orange drive air to unit ¼” gray foot control inlet 1/8” blue water to unit ¼” blue water to cuspidor 1/8” green purge
Foot Control Connections 1/4” Orange Drive air out 1/4” Gray Drive air in
Summit Dental Systems
14
Umbilical Entering Tray Head
Summit Dental Systems
15
Utility Center Tubing Diagram Post and Swing Mounted Unit
Water and Air Regulator Assembly
Description Part # Description Part # Wet & Dry Ft Ctrl 5-020-0058 ¼” Blue Tubing 5-070-0049 Tubing, Sand 4H 5-070-0025 1/8” Blue Tubing 5-070-0028 Water Regulator 5-070-0103 1/8” Red Tubing 5-070-0027 Filter Shut-Off Block 5-070-0102 ¼” Orange Tubing 5-070-0047 Air Regulator 5-070-0111 1/8” Green Tubing 5-070-0083 ¼” Gray Tubing 5-070-0040 1/8” Yellow Tubing 5-070-0026
Summit Dental Systems
16
Flow Diagram & Parts - Box Assembly
Summit Dental Systems
17
Flow Diagram & Parts - Housing Assembly
Item Description Part # 1 Cup Fill Spout 5-030-3006 2 Bowl Rinse Spout 5-030-3004 3 Cusp. Bowl Housing 2-020-3035 4 Egg, Syringe Holder 5-020-3003 6 2-Way Push Button Valve - Bowl Flush 5-030-0054 7 2-Way Push Button Valve – Cup Filler 5-030-3000
Summit Dental Systems
18
Troubleshooting Guide
SYMPTOM PROBABLE CAUSE 1. Water does not drain. A. Check drain for clogs or blockage. 2. Cup Fill and/or Bowl Rinse too slow.
A. Adjust flow control valve. B. Kinked or pinched tubing. C. Check water pressure (40 PSI). D. Check water filter element in Junction Box (cup fill only).
3. Cup Fill and/or Bowl Rinse too fast.
A. Adjust flow control pinch valves. B. Check water pressure (40 PSI).
4. No water flow.
A. Kinked or pinched tubing. B. Check for blockage at pinch valve location. C. Replace element in water filter housing (cup fill only).
5. Little to no suction.
A. Replace suction solids screen under cuspidor. B. Check vacuum pump. C. Kinked or pinched tubing.
Summit Dental Systems
19
Parts List
Summit Dental Systems
20
Cuspidor Assembly
Item Description Part # Item Description Part # 1 Post Mounted 2-030-3001 5 Cup Fill Spout 5-030-3006 Utility Center 6 Cup Fill Push 5-030-3007
2 Porcelain Bowl 2-020-3035 Button 3 Syringe Holder 5-020-3003 7 Bowl Rinse Push 5-030-30084 Bowl Rinse Spout 5-030-3004 Button
Summit Dental Systems
21
Bowl Assembly 2-030-1000Post Mounted Box Assembly 2-030-3001
Item Description Part # Item Description Part # 1 Water Bottle Valve 2-030-0019 8 Spacer 2-030-00202 Back Cover 2-020-3029 9 Top Cover 2-020-30303 Chassis 2-030-0014 10 Beauty Collar 2-030-00354 HP/Syringe Holder 5-020-3003 11 Beauty Collar 2-030-00265 Water Bottle Cap 5-020-0283 12 Screw ¼-20 x 3/8 5-030-00786 Front Cover 2-020-3028 13 Screw 10-32 x 5/8 5-030-00797 Water Bottle Cover 2-020-0068 14 Washer ¼ 4-010-0042* Magnetic (on Cover) 4-020-0012
Summit Dental Systems
22
WARRANTY
Summit Dental Systems (SDS) warrants its products against defects in materials or workmanship
from the date of shipment to the Buyer as follows:
Summit Dental Systems (SDS) Equipment: Warranty Period: Chairs, Delivery Units, Cuspidors, Lights 5 Years
Control Block Diaphragm (part of Delivery Unit) Lifetime
All Upholstery, Stools, all Plastic Covers, and Cabinets 1 Year
Summit Dental Systems’ sole obligation under the warranty is to provide parts for repair, or at its
option, to provide a replacement product (excluding all labor and shipping fees). “In any action,
BUYER’S remedies are limited to the warranty described above. BUYER shall not be
permitted to claim lost profits, reliance, special, incidental, or consequential damages in
any proceedings.” The warranty does not cover damage from improper installation or
maintenance, accident or misuse. The warranty does not cover damage resulting from the use of
cleaning disinfecting or sterilization chemicals and processes. Failure to follow instructions
provided in Summit Dental Systems’ Operation and Installation Manuals (Owner’s Guides) may
void the warranty. In the event Warranty service must be performed to correct any defect, only
an authorized Summit Dental System dealer may perform any and all warranty repairs. Any
repairs by unauthorized dealers, technicians, or repairmen may void the warranty.
In the case of a defective warranty item, a copy of the replacement invoice, model and serial
number of the product under which it was replaced, and a description of symptoms of the
defect must be returned with the part within 30 days of the replacement invoice date to
Summit Dental Systems, 6277 NW 28th Way, Ft. Lauderdale, FL 33309, USA, in order to
receive credit. Any and all expenses for freight, labor to perform warranty service, and
purchase of spare parts are the responsibility of the buyer. Any fraudulent claims made may
void the warranty. Any additional warranty that may be provided by an authorized Summit
Dental Systems dealer is the sole responsibility of said dealer.
SDS reserves the right to make changes or improvements on any products without being
required to modify existing equipment in a like manner.
Please complete and retain for your records the following Information: In case of warranty part replacement/repair or when ordering a part, please call your authorized
Summit Dental Systems dealer and have the following information available:
Owners’ Name: Phone #:
Model #: SDS Serial #:
Dealer: Phone:
Purchase Date:
In the case of a defective warranty item, a copy of the replacement invoice,
model and serial number of the product under which it was replaced, and a
description of symptoms of the defect must be returned with the part within
30 days of the replacement invoice date to Summit Dental Systems, 6277 NW
28th Way, Ft. Lauderdale, FL 33309, USA, in order to receive credit. Any and
all expenses for freight, labor to perform warranty service, and purchase of
spare parts are the responsibility of the buyer. Any fraudulent claims made
may void the warranty. Any additional warranty that may be provided by an
authorized Summit Dental Systems dealer is the sole responsibility of said
dealer.
SDS reserves the right to make changes or improvements on any products without being required
to modify existing equipment in a like manner.
6277 NW 28th Way – Ft. Lauderdale, FL 33309 Phone: (800) 275-3368 www.summitdental.com
MT Promedt Consulting GmbH Altenhofstrasse 80 D-66386 St. Ingbert, Germany