INSTALLATION

USE AND MAINTENANCE

USEFUL ADVICE

Heating cooker - Heating stove User guide

EN

2

3

Dear Customer, Thank you for choosing a “KLOVER” product. We hope you will be fully satisfied with your purchase. Please read the warranty certificate carefully. This is found on the last page of this User Guide. Please complete the attached warranty card in full and send it to us within 10 days of the purchase date. Thank you once again for choosing KLOVER products. These models are the result of forty years of experience in the manufacture of solid-fuel products (wood and pellets). The manual contains a detailed description of the heating cooker/heating stove and its operation, alongside instructions for proper installation, basic maintenance and checks to be performed regularly. It also contains practical advice for obtaining maximum performance from the cooker-boiler/stove-boiler with minimum fuel consumption. Stay warm with KLOVER!

4

DICHIARAZIONE DI CONFORMITÀ

DECLARATION OF CONFORMITY

In accordo con la Direttiva 89/106/CEE (Prodotti da Costruzione), il Regolamento CE n. 1935/2004 (Materiali e Oggetti destinati a venire a contatto con prodotti alimentari), la Direttiva 2006/95/CEE (Bassa Tensione) e la Direttiva 2004/108/CEE

(Compatibilità Elettromagnetica). Compliant with Directive 89/106/EEC (Construction Products), CE Regulation No. 1935/2004 (Materials and Articles intended to

come into contact with foodstuffs), Directive 2006/95/EEC (Low Voltage) and Directive 89/336/EEC (Electromagnetic Compatibility).

N° di identificazione - Identification No. : KP-01

Emesso da - Issued by : KLOVER s.r.l. Via A. Volta, 8 37047 San Bonifacio (VR)

Tipo di apparecchio - Type of equipment : Solid fuel-burning cookers

Marchio commerciale -Trademark : KLOVER

Modello o tipo - Model or type : HEATING COOKER

Uso - Use : Domestic heating and cooking

Costruttore - Manufacturer : KLOVER s.r.l. Via A. Volta, 8 37047 San Bonifacio (VR)

Ente notificato - Notified body : NB 1881 IMQprimacontrol S.R.L. I - 31020 Zoppè – San Vendemmiano (TV) Via dell’Industria, 55

Le norme armonizzate o le specifiche tecniche (designazioni) che sono state applicate in accordo con le regole della buona arte in materia di sicurezza in vigore nella CEE sono:

The following harmonised standards or technical specifications (designations) that comply with good engineering practices concerning safety matters in force within the EEC have been applied:

Norme o altri riferimenti normative Standards or other regulatory references

Rapporto di Prova ITT Initial Type Test Report

EN 12815 CPD-07-011 EN 60335-1 EN 50165 EN 55014-1 EN 61000-3-2 EN 61000-3-3 EN 55014-2

In qualità di costruttore e/o rappresentante autorizzato della società all’interno della CEE, si dichiara sotto la propria responsabilità che gli apparecchi sono conformi alle esigenze essenziali previste dalle Direttive su menzionate.

As the manufacturer’s authorised representative within the EEC, we hereby declare under our sole responsibility that the equipment complies with the provisions of the Directives stated above.

San Bonifacio (VR), 05/10/2007

Mario Muraro Chairman of the Board

5

HEATING COOKERS

and

HEATING STOVES

models K top – KP top and

models TS top – TSP top

S.R.L.

6

Copyright All rights reserved. The reproduction of any part of this manual in any form, without the explicit written permission of KLOVER srl, is forbidden. The content of this manual may be modified without notice. Although the documentation contained in this manual has been carefully compiled and checked, KLOVER srl cannot be held liable for any damages arising from the use of the same. Copyright © 2002 KLOVER srl Latest revision: February 2012

7

GENERAL INDEX Introduction…………………………….…………………………….. 9 Important safety instructions…………………………………………….. 9 Some precautions……………………………………………..………….. 10 Conventions used in the manual……………………………….……….. 10

Technical data……………………………………….……………..... 11 Hydraulic connections for the heating cooker…………………………. 11 Top view of heating cooker……………………………………………... 12 Heating cooker wall-mounted installation option………………………. 13

Hydraulic connections for the heating stove…………………………… 14 Top view of heating stove………………………………………………… 15 Heating stove wall-mounted installation option………………………... 16 Technical specifications………………………………………………….. 17 Heating cooker/heating stove components…………………………….. 19

Assembly……………………………….………………….…………. 22 Positioning………………………………………………………………… 22 External air vent…………………………………………………………… 23

Example of heating cooker/heating stove – boiler connection………. 24 Example of heating cooker/heating stove connection………………… 25

Connections………………………………………………………….. 26 Hydraulic connection……………………………………………………… 26 Electrical connection……………………………………………………… 27 Electronic control unit…………………………………………………….. 28 Control of any 3-way valves for the DHW circuit………………………. 34 Control of any coupled boilers…………………………………………… 35 Example of electrical connection……………………………………….. 36 The flue and connection to the same ………………………….………. 38 The chimney………………………………………………………………. 40

Starting up……………………………………………………………. 41 Filling the system for the first time……………………………………… 41

Ignition……………………………………………………………………… 42 The oven and hob (heating cooker only)………………………………. 43

Producing domestic hot water (suitable models only)……………….. 44 Anti-freeze protection…………………………………………………….. 45 Operating principle……………………………………………………….. 45 Boiling……………………………………………………………………… 45

Maintenance………………………………………………….………. 46

8

Cleaning the boiler unit………………………………………………….. 46 Cleaning the ceramic glass………………………………… ………….. 53 Cleaning the flue…………………………………………………………. 53 Maintenance of the boiler unit……………………………… ………….. 54

The wood to be burned……...……………………………………... 55 Types of wood…………………………………………………………….. 55

Troubleshooting……………………………………………………... 58

Useful advice…………………………………………………………. 60

Notes…………….….…………………………………………………. 61

Warranty certificate…………………………………………………. 62

9

INTRODUCTION

Important safety instructions

Please read these instructions before installing and using the product.

The installation and initial start-up of the heating cooker/heating stove must be performed by skilled personnel trained in the relevant safety standards. They will be responsible for the definitive installation of the appliance and its proper operation. KLOVER srl shall not be held liable if these precautions are not observed.

During installation of the appliance, all local regulations - including those referring to national and European Standards - must be observed.

Connect the flue gas outlet to a flue with the specifications described in the Connections section of this User guide.

The appliance is not suitable for installation on a shared flue system.

If the flue should catch fire, use appropriate fire extinguishing equipment or call the fire brigade.

Connect the product to an earthed power socket. Avoid using sockets controlled by switches or automatic timers.

Do not use damaged or worn power supply cables.

If a multiple socket is used, make sure that the total voltage of the connected devices does not exceed the rated voltage for the socket. Also make sure that the total voltage of all the devices connected to the socket does not exceed the maximum permitted level.

Do not use flammable substances to clean the appliance or its parts.

Do not leave containers of flammable substances in the room where the heating cooker/heating stove is installed.

Do not use the appliance as an incinerator or for any use other than that for which it was designed.

Do not use different fuels to those recommended.

Do not use liquid fuels.

10

The appliance, and its outer surfaces in particular, become very hot to the touch during operation; handle with caution in order to avoid burns.

Only use original spare parts recommended by the manufacturer.

Do not make any unauthorised modification to the device.

A few precautions Do not touch the hot components of the product (ceramic glass,

enamelled cast-iron hob, flue pipe) during normal operation.

Use the dedicated lit switch to switch the electrical panel off. Do not disconnect the power supply cable while the heating cooker/heating stove is running.

Keep children away from the heating cooker/heating stove when it is running since they could get burnt by touching its hot components.

Children and inexperienced people must not be allowed to use the appliance.

Conventions used throughout the manual Hazard to the operation of the heating cooker/heating stove. General hazard for personal safety.

Hazard for people and objects due to materials at high temperatures.

Hazard to people and objects due to electrical power.

Risk of burns due to hot liquids.

11

TECHNICAL DATA Hydraulic connections for the heating cooker

875

RX

M

R

FC

X

285

295330

530

70

115

165

200

210

35

435

565

940

35

250

975

Description of connections:

M = System Flow ¾” M Gas

R = System Return ¾” F Gas

F = Domestic cold water inlet (on KP models only) ½” M Gas

C = Domestic hot water outlet (on KP models only) ½” M Gas

X = Boiling discharge ¾” M Gas Flue gas outlet diameter 150 mm M

12

Top view of heating cooker

600

665

1000

predisposizionesulla base perl'allacciamento

all'impiantopassando dalpavimento

155

155

485

635

215

250

135

100 145

13

Heating cooker wall-mounted attachments option

mr

fc x

40

70

95

140

190

220

250

14020

0

330

975

105

875

Description of connections:

m = System Flow ¾”

r = System Return ¾”

f = Domestic cold water inlet (on KP models only) ½”

c = Domestic hot water outlet (on KP models only) ½”

x = Boiling discharge ¾”

14

Hydraulic connections for heating stove

875

RX

M

R

FC

X

285

295330

530

70

115

165

200

210

595

35

435

565

250

940

35

Description of connections:

M = System Flow ¾” M Gas

R = System Return ¾” F Gas

F = Domestic cold water inlet (on TSP models only) ½” M Gas

C = Domestic hot water outlet (on TSP models only) ½” M Gas

X = Boiling discharge ¾” M Gas

Flue gas outlet diameter 150 mm M

15

Top view of heating stove

600

665

622

275

515

170

150

16

Heating stove wall-mounted attachments option

mr

fc x

875

40

70

95

140190

220

250

14020

0

330

595

105

Description of connections:

m = System Flow ¾”

r = System Return ¾”

f = Domestic cold water inlet (on TSP models only) ½”

c = Domestic hot water outlet (on TSP models only) ½”

x = Boiling discharge ¾”

17

Technical Specifications

Below is a table with all the main technical specifications for the heating cookers.

TECHNICAL SPECIFICATIONS MODEL

K top KP top Kcal/h

HEAT OUTPUT

KWatt

25.500

29,6

BOILER UNIT WATER CAPACITY lt 53 50

PRODUCTION OF HOT WATER Δt=35°C lt/min / 12

MAXIMUM WOOD CONSUMPTION* Kg/h 5 – 8

HEATABLE VOLUME m3 560

EFFICIENCY 83%

VOLUME OF COMBUSTION CHAMBER dm3 46

SIZE OF LOADING MOUTH (wxh) cm 25 x 23

SIZE OF COMBUSTION CHAMBER (wxhxd) cm 26 x 40 x 44

FLUE PIPE DIAMETER mm 150

WIDTH mm 1000

HEIGHT mm 870

DEPTH mm 600

WEIGHT Kg 245 250

*Wood consumption is subject to the quality and dryness of the wood.

18

Below is a table with all the main technical specifications for the heating stoves.

TECHNICAL SPECIFICATIONS MODEL

TS top TSP top Kcal/h

HEAT OUTPUT

KWatt

22.500

26,2

BOILER UNIT WATER CAPACITY lt 53 50

PRODUCTION OF HOT WATER Δt=35°C lt/min / 12

MAXIMUM WOOD CONSUMPTION* Kg/h 5 – 8

HEATABLE VOLUME m3 495

EFFICIENCY 83%

VOLUME OF COMBUSTION CHAMBER dm3 46

SIZE OF LOADING MOUTH (wxh) cm 25 x 23

SIZE OF COMBUSTION CHAMBER (wxhxd) cm 26 x 40 x 44

FLUE PIPE DIAMETER mm 150

WIDTH mm 622

HEIGHT mm 870

DEPTH mm 600

WEIGHT Kg 200 205

*Wood consumption is subject to the quality and dryness of the wood.

19

Heating cooker/heating stove components

Cover SICURO TOP

Reservoir SICURO TOP

with stainless steel and magnesium anode heat exchangers

System air vent valve (jolly)

Electronic control unit (see page 28)

20

Ash drawer with slots for adjusting combustion air

flow

Grille raising lever (heating cooker only)

Heating system circulation pump

Power supply cord + isolated cable for 3-way motorised valve (if fitted)

21

Smoke damper

Draught regulation handle. When placed in a vertical position the

damper is open; when horizontal the damper is closed.

Handle for internal smoke damper. Turning this lever clockwise closes the

smoke damper and increases oven efficiency; turning it anticlockwise opens the smoke damper, extracting the smoke directly to the flue. (heating cooker only)

22

ASSEMBLY Positioning

The first step to ensure the best installation of the heating cooker/heating stove is to identify the best location for it; take the following into account:

The possibility of including an external air vent;

The possibility of creating a straight flue, if possible coaxial to the heating cooker/heating stove output;

The possibility of creating piping required for the boiling discharge;

Proximity to the main water drain and/or the boiler (if one already exists);

Proximity or ease of connection to the water system.

Once the best location has been determined, position the heating cooker/heating stove, making sure to leave at least 2cm of space between it and any nearby furniture. The unit must be installed on a floor with a suitable load capacity. If the existing building does not fulfil this requirement appropriate measures (e.g. load distribution plate) must be taken. The minimum safety distance from flammable materials must be at least 300 mm from the sides and back of the heating cooker/heating stove. The installation area must ensure easy access for cleaning the unit itself, the fume exhaust ducts and chimney flue. The air extraction devices must not be used in the same room as the appliance, unless an adequate ventilation air supply is provided.

23

External air vent

Wood consumes oxygen when it burns. It is therefore essential that oxygen is reintroduced to the room in which the heating cooker/heating stove is installed to prevent the air in the room from becoming "heavy" and unbreathable. It is mandatory to install an external air vent with a minimum passage of at least 490 cm2 (round hole with minimum diameter of 25 cm; rectangular hole minimum size 20x25 cm).

STANDARD UNI 10683 FORBIDS THE DRAWING OF COMBUSTION AIR FROM GARAGES, WAREHOUSES WHERE COMBUSTIBLE MATERIAL IS STORED OR FROM BUSINESSES WITH A FIRE HAZARD. KEEP ALL OPENINGS FREE FROM OBSTRUCTIONS.

24

CONNECTION EXAMPLE HEATING COOKER/HEATING STOVE – GAS BOILER

EN

TR

ATA A

CQ

UA

FR

ED

DA S

AN

ITAR

IA

SC

AR

ICO

EBO

LLIZ

ION

E

CO

LLETTO

RE

DI

RIT

ORN

O

COLLETTORI

DI MANDATA

USCITA ACQUA

CALDA SANITARIA

CALD

AIA

A G

AS

Leg

en

da

:

MA

ND

AT

A I

MP

IA

NT

O

RIT

OR

NO

IM

PIA

NT

O

AC

QU

A F

RED

DA

SA

NITA

RIA

AC

QU

A C

ALD

A S

AN

ITA

RIA

VA

LV

OL

A D

I Z

ON

A

VA

LV

OL

A M

OTO

RIZ

ZA

TA

A 3

VIE

VA

LV

OL

A D

I R

IT

EG

NO

VA

LV

OL

A A

SF

ER

A

ZONA

1

ZONA

2

ZONA

3

TERMOCAMINI-TERMOCUCINE-TERMOSTUFE

TERMOSTUFE a PELLET-CALDAIE a LEGNA

SAN BONIFACIO (VR) tel. 0456 101 859 - fax 0456 101 858

TERMOCAMINI-TERMOCUCINE-TERMOSTUFE

TERMOSTUFE a PELLET-CALDAIE a LEGNA

SAN BONIFACIO (VR) tel. 0456 101 859 - fax 0456 101 858

Qu

esto

sch

em

a è

pu

ram

en

te in

dia

tivo e

non

costi

tuis

ce im

peg

no o

resp

on

sab

ilit

à a

lcu

na d

a p

arte

di K

LO

VER

s.r

.l.

e d

ei su

oi collab

oratori.

La p

rog

ett

azio

ne

esecu

tiva e

la c

on

seg

uen

te m

essa in

op

era d

ovran

no e

ssere r

ealizzate

nel rig

oroso r

isp

ett

o d

elle n

orm

e v

igen

ti.

25

CONNECTION EXAMPLE HEATING COOKER/HEATING STOVE

EN

TR

ATA A

CQ

UA

FR

ED

DA S

AN

ITAR

IA

SC

AR

ICO

EBO

LLIZ

ION

E

CO

LLETTO

RE D

I

RIT

ORN

O

USCITA ACQUA

CALDA SANITARIA

Leg

en

da

:

MA

ND

AT

A I

MP

IA

NT

O

RIT

OR

NO

IM

PIA

NT

O

AC

QU

A F

RE

DD

A S

AN

ITA

RIA

AC

QU

A C

ALD

A S

AN

ITA

RIA

VA

LV

OL

A D

I Z

ON

A

VA

SO

D'E

SP

AN

SIO

NE

CH

IU

SO

VA

LV

OL

A D

I S

IC

UR

EZ

ZA

GR

UP

PO

DI R

IE

MP

IM

EN

TO

ZONA

1

ZONA

2

ZONA

3

CO

LLETTO

RI

DI

MAN

DATA

2,5

BA

R

6 B

AR

TERMOCAMINI-TERMOCUCINE-TERMOSTUFE

TERMOSTUFE a PELLET-CALDAIE a LEGNA

SAN BONIFACIO (VR) tel. 0456 101 859 - fax 0456 101 858

TERMOCAMINI-TERMOCUCINE-TERMOSTUFE

TERMOSTUFE a PELLET-CALDAIE a LEGNA

SAN BONIFACIO (VR) tel. 0456 101 859 - fax 0456 101 858

Qu

esto

sch

em

a è

pu

ram

en

te ind

iati

vo e

non

costi

tuis

ce im

peg

no o

resp

on

sa

bilit

à a

lcu

na d

a p

arte

di K

LO

VER

s.r

.l.

e d

ei su

oi collab

oratori.

La p

rog

ett

azio

ne

esecu

tiva e

la c

on

seg

uen

te m

essa in

op

era d

ovran

no e

ssere r

ealizzate

nel rig

oroso r

isp

ett

o d

elle n

orm

e v

igen

ti.

26

CONNECTIONS Hydraulic connection

The hydraulic connections must be made in a rational manner. using the connections on the heating cooker/heating stove template. To facilitate the connection of the pipes, we have provided all plumbing connections on the left side, leaving a spacious area for making the appropriate connections. The heating cooker/heating stove can be coupled with any other boiler already installed in the system. Of course all necessary safety devices and interception valves must be installed according to the system.

THE HEATING PLUMBING SYSTEM MUST BE FITTED WITH A FILLING UNIT, A CLOSED EXPANSION VESSEL SUITABLE FOR THE SYSTEM AND THE APPROPRIATE SAFETY VALVES (2.5 BAR) THE DHW SYSTEM MUST HAVE A SAFETY VALVE CALIBRATED TO 6 BAR.

NOTE : THE SYSTEM MUST BE DIMENSIONED FOR AN AVERAGE FLOW TEMPERATURE OF 55°C.

THE HEATING COOKER/HEATING STOVE MUST BE INSTALLED EXCLUSIVELY BY QUALIFIED ENGINEERS. STRICTLY COMPLY WITH THE INSTRUCTIONS IN THIS GUIDE. THE MANUFACTURER ACCEPTS NO LIABILITY FOR DAMAGE CAUSED BY INCORRECT ASSEMBLY.

THE MAXIMUM MAINS WATER PRESSURE SHOULD NEVER EXCEED 2.5 BAR; RECOMMENDED OPERATING PRESSURE: 1.2 BAR.

DO NOT PASS ELECTRIC CABLES IN THE IMMEDIATE VICINITY OF THE FLUE GAS PIPE, UNLESS THEY ARE INSULATED WITH SUITABLE MATERIALS. IN THE EVENT OF WATER WITH FIXED RESIDUE AT 180°C THAT EXCEEDS 300 MG/L IT IS ESSENTIAL TO INSTALL A WATER SOFTENER UPSTREAM OF THE HEATING COOKER/HEATING STOVE INLET.

27

Electrical connection

The electric connection must only be performed by qualified technicians, in adherence with general and local safety standards. Check that the power supply voltage and frequency correspond to 220V – 50 Hz. The device's safety is guaranteed when it is properly connected to an efficient earthing system. When making the electric connection to the mains power supply, provide a 6 A – Id 30 mA differential circuit breaker switch with relevant breaking load. The electric connections, including the earth connection, must be made after switching off the electrical system. When completing the system, bear in mind that the cables must be laid in an unmovable manner and far from parts subject to high temperatures. During the final wiring of the circuit, only use components with a suitable electric protection rating. KLOVER srl accepts no liability for injury to persons or animals or damage to objects due to failure to connect the heating cooker/heating stove to earth or failure to comply with IEC specifications.

Installation and electrical connection should be carried out by expert technicians using suitable equipment. Connection to the mains power supply should only be carried out after the wires have been connected to the terminal board.

Klover accepts no liability for damages caused by improper connections or inappropriate use.

28

Electronic control unit

Two cables exit the control unit, one of which has no plug. The cable with the plug should be connected to a mains socket with the specifications detailed above. The cable with no plug should be connected to the three-way motorised valve (if fitted). The electric control unit, already fitted in the heating cooker/heating stove, is used to control and command the start-up of the pump and motorised 3-way valve (if fitted). It is composed of:

master switch (used to supply power to the control unit itself);

pump adjustable thermostat (used to activate or deactivate the pump when the temperature set on the thermostat is reached or not);

valve adjustable thermostat (used to exchange the motorised valve (if fitted) when the temperature set on the thermostat is reached or not. It is normally used for the DHW connection in combination with another boiler);

AUX adjustable thermostat (used to control the wall-mounted boiler (where applicable), when the temperature set on the thermostat is reached or not);

thermometer (indicates the temperature of the water inside the heating cooker/heating stove);

acoustic alarm (activates whenever the water in the boiler reaches and exceeds the temperature of 90-95°C);

level switch (indicates the water level inside the boiler unit).

The cable with no plug leaving the control unit should be connected to the motorised three-way valve (where fitted). The control unit has an internal fuse T 3,15A.

29

4

2

Set1 3 4

POMPA

VALVOLA

AUX

DESCRIPTION OF THE KEYS

P1 ON/OFF this button, when pressed for two consecutive seconds, switches on/off of the control unit depending on whether it is off or on respectively.

During normal operation of the heating cooker/heating stove the control unit must ALWAYS be switched on.

P2 DECREASE TEMPERATURE decreases the temperature value on the thermostat indicating the minimum water temperature required for the boiler to turn on the pump and switch any 3-way motorized valve fitted.

P3 INCREASE TEMPERATURE increases the temperature value on the thermostat indicating the minimum water temperature required for the boiler to turn on the pump and switch any 3-way motorized valve fitted.

P4 SET/MENU provides access to the set thermostat values signalled by the associated PUMP / VALVE / AUX / SERV LEDs flashing. It also allows you to save changes made to the values for each thermostat.

DESCRIPTION OF LEDs

L1 PUMP LED this LED is lit when the pump thermostat has been selected.

P1 P2 P3 P4

L5

L1

L2

L3 L4

L6

L7

30

L2 VALVE LED this LED is lit when the valve thermostat has been selected.

L3 AUX LED this LED is lit when the auxiliary thermostat has been selected.

L4 LEVEL SWITCH LED this LED is lit when there is no water inside the reservoir or when the water level is too low.

L5 OFF LED this LED is lit when the control unit is off.

L6 DHW LED this LED is lit when the dhw function is active.

L7 SERV LED this LED is lit when the service thermostat has been selected.

LINEA230 Vac

POMPA230 Vac

VALVOLA230 Vac

AUX

1 2 3 4 5 6 7 8 9 10 1112 13 14

N L

LO

N

LO

N

LO

N

LO

FF

NO

CO

M

NC

23 22 21 20 19 18

LIVEL. SONDA

15

LO

FF

17 16

N N NSERV

230 Vac

Inputs PROBE Water Probe: Temperature Range 0 – 100 °C

H2O LEVEL ON/OFF permission: Level switch

Outputs

PUMP System pump: 230 Vac power supply

Terminals 13(FON) - 14(N)

SERV Service: 230 Vac power supply

Terminals 9(FON) - 10(N)

VALVE Valve: 230 Vac power supply

Terminals 6(FON) - 7(N) - 8(FOFF)

AUX Auxiliary: Free contacts

Terminals 3(NO) - 4(COM) - 5(NC)

31

FUNCTIONALITY

1- SWITCHING ON/OFF: The control unit is switched on/off by pressing and holding down the P1 (ON/OFF) button

The OFF status is signalled by the lighting of LED L5.

2- SAFETY function: If the temperature detected by the PROBE exceeds the value of the Safety Thermostat, this forces the activation of the PUMP.

3- ALARM function: If the temperature detected by the PROBE exceeds the value of the Alarm Thermostat, this activates the acoustic and visual signal.

SILENCE: by pressing any button, the acoustic signal is deactivated for 5 minutes.

4- NO ICE function: If the temperature detected by the PROBE goes below the value of the ANTI-FREEZE Thermostat, this activates the timed PUMP outlet.

The associated LED L1 is lit and the word ICE starts flashing on the display.

5- PUMP ANTI-LOCKING programme: In the event of inactivity of the PUMP outlet for longer than the ANTILOCKING Timer, this activates the outlet of the PUMP. The associated LED L1 is lit and bLP appears on the display.

6- SECURE TEMP function: If the device is OFF and in the SAFETY condition,

the device automatically switches itself to ON status.

7- LEVEL SWITCH function: The closure of the input contact determines the activation of LED L4.

8- OUTPUTS function: PUMP ON: for a temperature above the PUMP thermostat

temperature for a temperature above the ALARM thermostat temperature

32

for a temperature below the ANTI-FREEZE thermostat temperature

VALVE ON: for a temperature above the VALVE Thermostat temperature

AUX ON: for a temperature above the AUX Thermostat temperature

SERV ON: for a temperature above the SERV thermostat temperature

9- DHW function: By holding down the P2 (-) and P3 (+) buttons at the same time it is possible to activate the DHW function. At this point, while the L6 LED flashes, just set the time (in minutes) for which you want to have all the heat dedicated to the production of domestic hot water. By activating this function, the pump turns off and remains off until the minutes set for this function have elapsed. When this function is active, the pump will turn on only if the safety temperature of 85 ° C is reached. It is possible to deactivate this function by holding down the P2 (-) and P3 (+) buttons again.

MAIN menu

With a simple click of the P4 (SET) button, it is possible to scroll though the values of the set Thermostats signalled by the flashing of the associated PUMP / VALVE / AUX LEDs

To change the value: o Go to the Thermostat value to be changed.

By using the P2 (-) and P3 (+) buttons, it is possible to increase/decrease the value.

To save the change, press P4 (SET).

To exit the menu, press P1 (ESC) or wait for 5 seconds.

Parameters Symbol Min Factory setting

Max Recommended

values Reference

LED

PUMP thermostat

A01 50 55 85 Minimum

55 L1

VALVE thermostat

A02 20 65 85 65 L2

AUX thermostat

A03 20 85 85 50 L3

SERV thermostat

A04 20 85 85 55 L7

33

FAULT SIGNALLING AND ALARMS The control unit signals faults associated with the probe via a flashing message:

Lo: indicates a value below the set scale (temperature below 0°C)

Probe interrupted

Hi: indicates a value above the set scale (temperature above 100℃)

Probe in short-circuit

PARAMETER SETTINGS

ANTI-FREEZE activation thermostat [°C] 6

SAFETY function activation thermostat [°C] 85

ALARM function activation thermostat [°C] 90

PUMP thermostat hysteresis (A01) [°C] 3

VALVE thermostat hysteresis (A02) [°C] 3

AUX thermostat hysteresis (A03) [°C] 3

SERV thermostat hysteresis (A04) [°C] 3

ANTILOCKING timer [h] 168

ANTILOCKING pump activation time [sec] 30

ANTI-FREEZE Pump OFF time [min] 5

ANTI-FREEZE Pump ON time [sec] 20

Type of Probes (10K blue=’0’ - 100K grey= ‘1’) no. 0

STANDBY enabling no. 1

ANTI-FREEZE function enabling no. 1

PARAMETERS THAT CANNOT BE MODIFIED

ANTI-FREEZE thermostat hysteresis [°C] 1

SAFETY thermostat hysteresis [°C] 1

ALARM thermostat hysteresis [°C] 1

TECHNICAL SPECIFICATIONS

Power supply: 230 Vac ±10%~50Hz Protective fuse T3,15A

Mechanical dimensions:

Built-in temperature controller: 120 x 80 x 50 mm

Temperature probe:

silicone/pvc cable Operating temperature: -50℃/130℃ Measurement limits :0 – 99°C Precision: ±1℃

Outputs:

PUMP output: power supply - 230 Vac max capacity 5 A 250 Vac VALVE output: power supply - 230 Vac max capacity 5 A 250 Vac AUX output: free contact max capacity 5 A 250 Vac SERV output: power supply - 230 Vac max capacity 5 A 250 Vac

Standards applied: EN 60730-1 50081-1 EN 60730-1 A1 50081-2

34

Control of any 3-way valve fitted for the DHW circuit The heating cooker/heating stove is equipped as standard with a control for a possible 3-way motorized valve to be installed on the domestic hot water circuit. (see wiring diagram on page 30). Inside the attachment compartment on the heating cooker/heating stove, there is a cable with 4 wires that can be used to control this valve. The four wires in the cable have different colours, and precisely:

1. Grey or blue wire = COMMON TO 3-WAY VALVE 2. Black wire = HEATING COOKER/HEATING

STOVE SIDE 3. Brown wire = GAS BOILER SIDE 4. Yellow/green wire = GND

Below is an example of a connection using a 3-way valve with spring return. Remember that the hydraulic connection must be made in such a way that when the valve is at rest, the water passes from the gas boiler. Only when the heating cooker/heating stove temperature is sufficient (the value is set from control panel) is the 3-way valve powered; it then closes the gas boiler circuit and opens the heating cooker/heating stove circuit.

MA

RR

ON

E

GIA

LLO

/V

ER

DE

GR

IGIO

O B

LU

NER

O

Valvola a 3 vie

N.B.: The brown wire can be used to control a service relay if fitted.

35

Control of any coupled boiler

If the heating cooker/heating stove is to be coupled with another boiler already installed on the system (e.g. wall-mounted gas boiler), it must be ensured that when the heating cooker/heating stove functions for the heating system, the boiler stops. In this way the setting (see wiring diagram on page 30) intervenes on the coupled boiler when the temperature set on the auxiliary thermostat on the wood-fired heating cooker/heating stove control unit is reached. In this way, there will never be two boilers functioning simultaneously on the same system. The coupled boiler is however always available for the production of domestic hot water. The contact on the two terminals at the back of the control unit (TERMINAL 4 COM and TERMINAL 5 NC) is open when the heating cooker/heating stove temperature is higher than that set on the aux thermostat. If the heating cooker/heating stove temperature is lower, the contact is closed. It is therefore easy to connect these two terminals with two wires to the Room Temperature Thermostat input of a coupled boiler.

Ingresso T.A.

Caldaia

morsetto 4

COM

morsetto 5

NC

36

Example of electrical connection

LINEA230 Vac

POMPA230 Vac

VALVOLA230 Vac

AUX

1 2 3 4 5 6 7 8 9 10 1112 13 14

N L

LO

N

LO

N

LO

N

LO

FF

NO

CO

M

NC

23 22 21 20 19 18

LIVEL. SONDA

15

LO

FF

POMPAIMPIANTO DI

RISCALDAMENTO

POMPASUPPLEMENTARE

VALVOLAMOTORIZZATA

A 3 VIE

CONTATTOTERMOSTATO

AMBIENTE

CALDAIA AGAS

SONDATEMPERATURA

ACQUA

SENSOREDI LIVELLO

ACQUA

17 16N N N

SERV230 Vac

ALIMENTAZIONEELETTRICA

37

LINE: Connect terminals 1 and 2 to the electrical power supply. (terminals already connected to power supply cable in the factory)

AUX: This is used to control a boiler coupled with the heating system where present. Connect terminals 4 and 5 (or 3 and 4 depending on the type of connection to the coupled boiler) to the TA (Room Thermostat) contact on the boiler. It is then possible to control the coupled boiler using the temperature set on the AUX thermostat; above the set temperature the coupled boiler turns off and comes on again only below the set temperature.

VALVE: Connect terminals 6, 7 and 8 to the 3-way motorised valve. This is used to control a motorised 3-way valve (or two 2-way motorised valves) installed on the dhw system. The valve opens the circuit at temperatures higher than those set on the VALVE thermostat (230V voltage on terminals 6 and 7) and closes the circuit at lower temperatures (230V voltage on terminals 7 and 8). (Terminals already connected at the factory to a cable suitable for connection to a 3-way valve - see page 34).

SERV: Additional thermostat supplied at 230V. Connect terminals 9 and 10. This can be useful, for example, for controlling an additional pump installed on the system. The additional pump will operate at temperatures higher than those set on the SERV thermostat. We recommend setting the SERV thermostat to temperatures higher than 55°C to prevent condensation, which would damage the heating cooker's boiler unit, from forming.

PUMP: Connect terminals 13 and 14 to the pump on the heating system. This is used to control the pump installed on the heating system. The heating pump will operate at temperatures higher than those set on the PUMP thermostat. We recommend setting the pump thermostat to temperatures higher than 55°C to prevent condensation, which would damage the heating cooker's boiler unit, from forming. (Terminals already connected to pump cable in the factory).

PROBE: Connect the water temperature probe to terminals 18 and 19. This is used to detect the water temperature inside the heating cooker. If the probe is not connected, the control unit's display shows “Lo”; if the probe is short-circuited, the display shows “Hi”. (Terminals already connected to Water Probe in the factory).

38

LEVEL.: Connect the level switch (water level sensor) to terminals 20 and 21. This is used to signal low water level inside the heating cooker boiler unit. (Terminals already connected to level switch in the factory).

The flue pipe and connection to the same

The flue is an essential component for the heating cooker/heating stove's efficient operation. The heating cooker/heating stove smoke outlet is 150mm in diameter. The minimum cross section of the flue pipe should be 180 mm. Every heating cooker/heating stove must have its own flue pipe, without other adjoining elements (boilers, chimneys, stoves etc.). The flue dimensions are closely related to its height, which must be measured from the heating cooker/heating stove flue gas outlet to the base of the chimney stack. In order to guarantee draught, the stack flue outlet surface must be twice as big as the flue cross-section. The combustion gases exhaust pipe, generated by the natural draught appliance, must respond to the following requisites:

It must seal off the combustion gases, besides being waterproof and suitably isolated and insulated in relation to the conditions of use (refer to UNI 9615);

It must be made of suitable materials capable of withstanding normal mechanical stress, heat, and the effects of combustion gases and condensate, if any;

It must go upwards after the vertical section, for the entire remaining part, with 20% minimum gradient; The sub-horizontal section must not have a length greater than ¼ of the effective height H of the flue or chimney, and must not be longer than 2,000 mm;

Preferably with a circular internal cross section: squared and rectangular cross sections must have rounded corners with a radius larger than 20 mm;

It must have a constant, free and independent internal cross section;

Rectangular cross-sections must have a maximum ratio of 1.5 between the sides;

If the flue is installed outside it is essential that it is insulated in order to avoid the flue gas cooling and the formation of condensate;

39

Parts made from non-combustible materials - capable of withstanding combustion gases and potential condensation - must be used for mounting the flue gas pipes (for the section from the appliance to the flue inlet);

It is forbidden to use fibre cement pipes to connect the appliance to the flue;

Flue pipes must not pass through rooms in which the installation of combustion devices is prohibited;

The flue pipes must be assembled in such a way as to guarantee adequate sealing of flue gases during low pressure operation of the appliance;

Horizontal tracts are prohibited, unless absolutely necessary;

It is prohibited to use counter sloping elements;

The flue gas pipe must allow for the recovery of soot or be cleanable, and must have a constant cross-section;

It is forbidden to allow other air intake conduits and system pipes to transit inside the flue gas pipes, even if over-sized.

40

Chimney

The chimney is a device crowning the flue, used to aid the dispersion of combustion gases. It must satisfy the following requirements:

It must have a usable outlet cross-section no less than double that of the flue onto which it is inserted;

In must be shaped in such a way as to prevent rainwater or snow from seeping into the flue;

Be built in such a way that, even in the event of winds from every direction and inclination, combustion exhaust is ensured.

The outlet height (where height refers to the top of the flue, regardless of any chimney stacks), must be outside of the so-called reflux zone, in order to prevent the formation of counter-pressures preventing the free discharge of combustion by-products into the atmosphere. It is therefore necessary that the minimum heights - indicated in the following diagrams - are observed:

Volume

tecnico

0,5

m 0,5

m

Distanza > 5 m Distanza < 5 mDistanza> 1,85 m

Distanza< 1,85 m

0,5

m o

ltre

il

co

lmo

Zona di

reflusso

1m

min

imo

15

°

41

INITIAL START-UP

Filling the system for the first time

After connecting the heating cooker/heating stove, fill the system as follows:

Unscrew the cap on the automatic air vent valve (jolly) on the heating cooker/heating stove (provided as standard on all models);

If necessary, very slowly loosen the pump vent plug, draining the fluid for a few seconds;

Fill the system very slowly in order to allow air bubbles to escape from the heating cooker/heating stove heat exchangers through the air bleed valve;

Bleed all radiators and any other deaeration systems present in the system in order to ensure that there are no air bubbles;

Fill the side reservoir on the heating cooker/heating stove with water with a fixed residue at 180°C of less than 300 mg/l. DO NOT USE DISTILLED WATER.

N.B.:THE WATER LEVEL IN THE RESERVOIR SHOULD COVER THE HEAT EXCHANGERS, LEAVING AT LEAST 4-5 cm FROM THE UPPER RED SEAL. REGULARLY CHECK THAT THE WATER IN THE RESERVOIR IS AT THE LEVEL OF THE EXHAUST PIPE AT 80-85 ° C. TOP UP AS NECESSARY.

After installation, check the seal of all hydraulic joints regularly during the first few days of operation.

NEVER OPERATE THE HEATING COOKER/HEATING STOVE WITHOUT WATER IN THE RESERVOIR. IN ADDITION TO NOT HEATING, IT MAY ALSO COMPROMISE THE OPERATION AND LIFE OF THE APPLIANCE. DO NOT USE DISTILLED WATER. NEVER EMPTY WATER INTO THE HEATING COOKER/HEATING STOVE SO AS NOT TO COMPROMISE ITS OPERATING LIFE.

42

Switching on

Perform the following operations:

Before switching the heating cooker/heating stove on, make sure that the control unit switch is on;

Make sure that there is water in the system and reservoir;

Set the thermostat that controls the pump to a temperature of 55-60 °C; NEVER set the temperature to lower than 55 °C because condensation could form in the boiler, which in time could ruin the heating cooker/heating stove;

Fully open the internal smoke damper turning the handle on the hob fully anti-clockwise (heating cooker only – see page 21);

Fully open the internal smoke damper on the flue pipe inlet by placing the handle in a vertical position (see page 21);

Slightly extract the ash drawer (by 3-4 cm) and open the slots on it;

Light the fire using seasoned, thin wood;

When the wood has ignited well, close the ash drawer and adjust the combustion air inflow using the front slots;

Close the internal smoke damper by turning the handle on the hob fully clockwise to increase the efficiency of the heating cooker and to provide more heat to the oven (heating cooker only). If necessary adjust the draught in the flue pipe by adjusting the smoke damper on the flue pipe inlet.

THE FURNACE MUST BE KEPT CLOSED AT ALL TIMES EXCEPT DURING REFUELLING IN ORDER TO PREVENT THE ESCAPE OF SMOKE. NEVER IGNITE THE HEATING COOKER/HEATING STOVE USING ALCOHOL OR OTHER HIGHLY FLAMMABLE LIQUIDS. Always remember to open the smoke damper a few seconds before loading the heating cooker/heating stove with new wood in order to prevent the backflow of smoke into the room.

43

WARNING!!!

IN ORDER FOR THE HEATING COOKER/HEATING STOVE TO OPERATE PROPERLY THE CAST IRON GRILLE INSIDE THE

COMBUSTION CHAMBER MUST BE POSITIONED AS SHOWN BELOW , TAKING CARE NOT TO INVERT IT, TO PREVENT THE ASH FROM COMPACTING AND NOT FALLING INTO THE ASH DRAWER.

The oven and hob (heating cooker only)

The oven on the heating cooker is heated by the exhaust gases. To increase the temperature of the oven, develop an intense flame by burning (with the grille low) pieces of thin, dry wood, slightly extracting the ash drawer (by 3-4 cm) and opening the slots on it. When the fire is burning well, close the internal smoke damper by turning the handle on the hob fully clockwise to increase the efficiency of the heating cooker and to provide more heat to the oven. If necessary adjust the draught in the flue pipe by adjusting the smoke damper on the flue pipe inlet. Move the wood every now and again using the fire hook supplied with the heating cooker in order to achieve a good flow of combustion air from below the cast iron grille.

44

The flue pipe and air inlet are the most important parts that ensure the correct operation of the cooker.

In the event of particular circumstances of poor flue pipe draught caused by particularly adverse weather conditions (strong wind, low pressure, etc.) partially close the internal smoke damper without closing it completely. Also adjust the smoke damper on the flue pipe inlet.

Producing domestic hot water (suitable models only)

Domestic hot water is produced instantly via a double heat exchanger immersed in water inside the heating cooker/heating stove. Therefore in order to have domestic hot water the heating cooker/heating stove must reach a temperature of at least 65°C. Set the heating cooker/heating stove to DHW output mode if a large amount of domestic hot water is required: “DHW mode” (see electronic control unit). The purpose of “DHW mode” is to postpone the heating pump start-up to higher temperatures so as to transfer all the heat produced at these temperatures to domestic hot water. In “DHW mode” it is possible to set a timer during which pump start up is postponed to 85°C. When DHW is no longer needed this function should be deactivated (see electronic control unit).

If water is particularly hard, it is essential to install an anti limescale device at the heat exchanger inlet, to be chosen according to the water type.

45

Anti-freeze protection In intensely cold periods it is good practice to leave the heating system running. In the event of prolonged absence, anti-freeze should be added to the heating water and the water inside the heating cooker/heating stove, or the system must be completely emptied. In a system subject to being emptied frequently it is essential that it is filled with water that has been appropriately treated to eliminate hardness that can lead to limescale deposits.

Operating principle The heating cooker is an economical wood-burning boiler in the shape of a cooker with an oven coated with majolica. You therefore have the pleasure of seeing the flame through the ceramic glass like in a normal stove, you can also cook on the cast iron hobs, and in addition the radiators in the home are also heated and DHW is supplied for all of the family. The heating cooker/heating stove can be combined with an appliance that is already installed (gas boiler, diesel oil boiler or wood-burning boiler etc...) or can function as the only source of heating for the home.

Boiling If for any reason (power cut, a pump fault, too much wood, etc…), the water in the heating cooker/heating stove reaches boiling point, carry out the following operations immediately:

Fully open all smoke dampers;

Open a DHW tap and leave the water to run until the temperature in the heating cooker/heating stove drops (KP top/TSP top models only).

Close the ash drawer and its air inlets completely. After having ascertained the reason for the high temperature, wait for everything to go back to normal (temperature below 60°C), then check the water level in the side reservoir and top up if necessary.

46

MAINTENANCE

Cleaning the boiler

Regular and systematic maintenance is a fundamental component for the good functioning, optimum heat yield and long life of the appliance over time. It is therefore recommended to clean the boiler periodically (at least once a year).

Before performing any cleaning or maintenance operations, make sure that the heating cooker/heating stove is off and completely cold and that the ash is also completely cold.

It is possible to reach all points affected by the flue gas by acting as follows:

HEATING COOKER

Remove the pipes that connect the heating cooker to the flue pipe and clean them if necessary.

Remove the smoke damper.

47

Remove the handle on the internal smoke damper, holding the internal blade with one hand to prevent it from falling behind the oven.

Remove both the handle and internal blade of the internal smoke damper.

48

Remove the cast iron upper hob and remove any ash deposits on top of and all around the oven. After cleaning, refit the hob, the internal

smoke damper, the smoke damper and flue pipes.

Open the vent under the oven to clean the gas circuit pipes, following the instructions below:

49

Loosen the two hex screws on the inspection vent.

1 2

50

Remove the vent as shown in the diagram and remove any deposits under the oven.

51

Refit the inspection vent as shown in the photos and retighten the hex screws.

HEATING STOVE

Remove the pipes that connect the heating stove to the flue pipe and clean them if necessary.

Remove the smoke damper.

52

Remove the cast iron upper hob and remove any ash deposits on top of and all around the oven. After cleaning, refit the hob, the smoke

damper and flue pipes.

53

Any deposits on the walls of the combustion chamber (if particularly resinous wood is burned) can be eliminated by making the heating cooker/heating stove work at maximum conditions for 30-40 minutes (in this case set the thermostat to 80°C) by burning thin dry wood. Leave the fire to go out and then scrape the inside walls using a steel spatula.

We recommend you periodically empty the ash drawer to always ensure an efficient flow of combustion air. The need to clean the DHW heat exchanger (KP top/TSP top models only) is indicated by a drop in the quantity or temperature of the water provided. For cleaning, contact your installation technician who will wash the heat exchanger using a dedicated pump and special liquid.

To clean the cast iron hob use washing up liquid and a non-abrasive sponge when the heating cooker/heating stove is cold.

Following a long period of disuse, check for obstructions in the flue before switching the heating cooker/heating stove on.

Cleaning the ceramic glass

Only clean the ceramic glass when the heating cooker/heating stove is off and completely cold. Use a damp cloth or a detergent specifically formulated for ceramic glass. Do not use abrasive sponges.

Cleaning the flue

The flue must be cleaned at least once a year at the start of the winter season, and also every time it becomes necessary. If cleaning is not performed, the operation of the heating cooker/heating stove and its components may be impaired.

The frequency of cleaning the heating cooker/heating stove and flue depends on the quality of the wood used.

USE TOP QUALITY WOOD IN ORDER TO OBTAIN THE BEST RESULTS.

54

Maintenance of the boiler unit

The heating cooker/heating stove is equipped with a special magnesium anode to protect the boiler unit and stainless steel heat exchangers from corrosion caused by stray currents in the system.

This anode also protects against galvanic corrosion.

The anode must be checked at least once a year and replaced when its diameter measures less than 15 mm.

To inspect the boiler, after having opened the left-hand hatch on the upper frame, remove the upper cover.

To replace the anode, just unscrew it and screw-in the new one, making sure that it does not come into contact with the stainless steel heat exchangers.

NEVER EMPTY WATER INTO THE HEATING COOKER/HEATING STOVE SO AS NOT TO COMPROMISE ITS OPERATING LIFE.

MAGNESIUM ANODE

55

THE WOOD TO BURN

Wood types

Wood is one of the most precious materials offered by nature. For heating purposes, it must be verified that the wood satisfies some important requisites that must not be ignored, the most important of which is without doubt the correct seasoning or drying, in other words the wood must have the correct degree of humidity, around 10-15%, therefore also the period of the year in which it is felled becomes important. This should coincide with the winter period. The correct seasoning (at least 2 years) provides fuel with an excellent yield that is not very pollutant. It must be kept in covered, well-aired places, already cut appropriately into pieces suitable for the furnace of the heating cooker/heating stove. Wood is divided into softwood and hardwood on the basis of the weight in kg of one cubic metre of material. Softwood that weighs about 300-350 kg/m3 is fir, pine, poplar, European alder, chestnut, willow, while hardwood that weighs about 350-400 kg/m3 is beech, ash, hornbeam, acacia and oak. Softwood ignites easily, is consumed quickly and develops a long flame and is used in ovens that require a long flame pass. Hardwood is more compact, the combustion is slower with a short flame, it lasts longer and is more suitable for domestic central heating. The wood to be burned for heating purposes has different features according to the plant variety from which it is obtained. Not all woods are the same and the features regarding the drying time and the calorific value vary from plant to plant. The calorific value depends on the level of humidity and its density. Top quality woods are beech, ash, hornbeam and acacia. Avoid resinous woods in general as they could compromise the life of the heating cooker/heating stove. Resinous woods have a rather sooty combustion and therefore, the flue and heating cooker/heating stove must be cleaned more frequently.

The calorific value of the different types of wood depends greatly on their humidity and consequently the power of the heating cooker/heating stove is directly affected by the type of wood used, on

56

average a well-seasoned wood has a calorific value of 3200 kcal/kg. Calorific value of wood based on its humidity level:

The CALORIFIC VALUE of the wood is the amount of heat yielded during combustion, referring to the unit quantity of the material burned. The calorific value of a wood type depends on the presence of lignin (6000 Kcal/Kg), or cellulose (4000 Kcal/Kg) as well as the amount of resin (8500 Kcal/Kg). The calorific value per unit of weight ( = absolute) is highest in Conifers

Absolute calorific value of conifers: 4700 Kcal/Kg

Absolute calorific value of broad-leaved species: 4350 Kcal/Kg.

On the other hand the SPECIFIC WEIGHT of the “broad-leaved species” is greater; therefore with equal volumes introduced into the heating cooker/heating stove, both the weight and amount of heat available for combustion are greater; in practice the relative calorific value is higher (referring to a unit of volume). Example: the calorific value of the white fir is practically the same as that of the oak, but the oak has a specific weight that is twice that of the fir. Therefore half the volume of oak must be introduced into the heating cooker/heating stove in order to have the same "heat" obtained from the fir.

% humidity Calorific value kcal/kg

15% 3490

20% 3250

25% 3010

30% 2780

35% 2450

40% 2300

57

*Calorific value (Kcal/Kg)

**Specific weight (Kg/m3)

WHITE FIR 4650 440

RED FIR 4857 450

MAPLE 4607 740

BIRCH 4968 650

HOP HORNBEAM 4640 820

CHESTNUT 4599 580

OAK 4648 900

CYPRESS 5920 620

BEECH 4617 750

ASH 5350 720

HOLM OAK / 960

LARCH 4050 660

EUROPEAN ALDER 4700 530

MANNA ASH / 760

SYCAMORE / 690

CYPRESS POPLAR 4130 500

FALSE ACACIA 4500 790

DOWNY OAK 4631 880

* theoretical absolute value ** wood seasoned in the air; residual humidity 12-15 %

58

TROUBLESHOOTING INSUFFICIENT DRAUGHT. DIFFICULT FLUE GAS EVACUATION. FLUE GAS ESCAPING INTO THE ROOM.

ELEMENTS TO CHECK ORIGIN

External air vent Inexistent;

Shutter closed;

Accidental obstruction;

Insufficient cross section.

Air vent (pipe) Insufficient cross section.

Combustion air damper Closed or badly adjusted.

Smoke damper Closed or badly adjusted.

Wood Excessive humidity.

Flue Hood fitting/flue gas channel

Insufficient cross section;

Insufficient height;

Accidental obstructions;

Periodical cleaning not performed;

Heat insulation or insulation insufficient or inexistent;

Use of unsuitable materials;

Heat insulation or insulation absent or insufficient;

Inadequate cross section (square or rectangular) or incorrect dimensioning;

Narrowing or presence of obstacles to the flow of flue gas;

Accidental obstructions;

Infiltrations of parasite air due to the use of materials not impermeable to gas and liquids;

Insufficient height.

Chimney Outlet height in reflow zone;

Close to or adjoining other chimneys;

Vicinity of obstacles, both natural and artificial;

Obstruction ( e.g.: birds nests);

Inadequate chimney pot shape;

Insufficient emission cross section.

59

CONDENSATE ESCAPING THROUGH THE MASONRY.

ELEMENTS TO CHECK ORIGIN

Flue gas channel Flue Condensate tray

Use of inadequate material;

Absence of or incorrect installation of the dedicated condensate collector with drain connected to the disposal system.

SELF-COMBUSTION INSIDE THE FLUE.

ELEMENTS TO CHECK ORIGIN

Hood fitting/flue gas channel Flue gas channel Flue

Periodical cleaning not performed.

WATER INSIDE THE HEATING COOKER/HEATING STOVE.

ELEMENTS TO CHECK ORIGIN

Flue Chimney

In the event of the total or partial absence of a chimney, the flue has not been installed parallel to the appliance;

Inadequate chimney.

Pump thermostat Pump start-up at temperatures that are too low (condensate is created).

THE OVEN AND HOB DO NOT HEAT UP.

ELEMENTS TO CHECK ORIGIN

Smoke damper Closed or badly adjusted.

Oven regulator Closed or badly adjusted.

Combustion air damper Closed or badly adjusted.

See “INSUFFICIENT DRAUGHT” page 58

See “The oven and hob" page 43

To prevent flue gas from escaping when loading wood, close the ash drawer and its air inlets completely and fully open the smoke damper.

60

USEFUL ADVICE

1. The temperature of the thermostat that controls the pump must never, for any reason, be set below 55°C, to prevent the formation of condensate that could corrode the internal boiler.

2. To give priority to DHW ( KP top/TSP top models only), set “DHW mode” (see page 32) and burn thin pieces of dry wood in order to increase the flame. After use of the DHW, lower the thermostat to 55-60 °C.

3. Open the smoke dampers completely before loading the wood. 4. When necessary, "move" the wood using the fire hook supplied or

by adjusting the grille raising lever (heating cooker only) in order to revive the flame.

5. To provide some humidity in the room where the heating cooker/heating stove is installed, just place a pan filled with water on the cast iron hob.

6. Never empty water into the heating cooker/heating stove so as not to compromise its operating life.

THE MANUFACTURER ACCEPTS NO LIABILITY FOR PROBLEMS DERIVING FROM THE FAILURE TO APPLY THE STANDARDS CONTAINED IN THIS MANUAL.

61

NOTES

________________________________

________________________________

________________________________

________________________________

________________________________

________________________________

________________________________

________________________________

________________________________

________________________________

________________________________

________________________________

________________________________

________________________________

________________________________

________________________________

________________________________

________________________________

62

WARRANTY CERTIFICATE

KLOVER s.r.l. guarantees the quality of materials, good construction and functionality of the heating cooker/heating

stove for the duration of 5 years, under the following conditions:

Any heating cooker/heating stove which, at the unquestionable discretion of the manufacturer, has material or construction faults will be repaired or replaced; with the exclusion of all costs for interventions required in situ, transport, refitting (hydraulic disassembly, assembly operations, any masonry and any other intervention necessary) and accessory materials;

The warranty excludes the ceramic glass and ceramic-majolica coverings, because as they are very fragile to blows, they can be damaged even accidentally, all the gaskets, the cast iron hob, the control board, all electric components and everything that is not part of the boiler or not produced by ourselves;

Incorrect installation carried out by unqualified personnel, tampering, failure to comply with the instructions contained in this manual and those regarding “workmanlike installation” shall void any warranty rights; the same applies to damages deriving from external factors. In any event, any compensation for direct or indirect damages is excluded, regardless of the nature and cause of these damages.

For appliances that require intervention in situ, the user must pay “a contribution for transfer expenses” in force at the date of the intervention. Within the first month of the warranty the repairs in situ will be performed free of charge, except for interventions not covered by the warranty as previously specified, which are the total responsibility of the user;

Please bear in mind that the goods travel under the customer’s responsibility, even if delivered carriage free, therefore we shall not be held liable for any damages due to loading and unloading operations, accidental knocks, storage in unsuitable places, etc.

The warranty is only considered valid if the attached card is returned within 10 days from the date of purchase fully filled-in;

The competent law court for settling any disputes is the Court of Verona.

63

64