Installing Flexi BTS modules in the BS- 241 II Service Shelter 0900d80580548a7f

Upload: mike-farrugia

Post on 15-Apr-2016

213 views

Category:

Documents


0 download

DESCRIPTION

Module installation in BS241 cabinets

TRANSCRIPT

Installing Flexi BTS modules in the BS-241 II Service Shelter

0900d80580548a7f

20900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d80580548a7f

The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.

The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.

Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.

This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.

The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.

Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.

Copyright © Nokia Siemens Networks 2009/6/26. All rights reserved

f Important Notice on Product Safety Elevated voltages are inevitably present at specific points in this electrical equipment. Some of the parts may also have elevated operating temperatures.

Non-observance of these conditions and the safety instructions can result in personal injury or in property damage.

Therefore, only trained and qualified personnel may install and maintain the system.

The system complies with the standard EN 60950 / IEC 60950. All equipment connected has to comply with the applicable safety standards.

The same text in German:

Wichtiger Hinweis zur Produktsicherheit

In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter Span-nung. Einige Teile können auch eine hohe Betriebstemperatur aufweisen.

Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Körperverlet-zungen und Sachschäden führen.

Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die Anlagen installiert und wartet.

Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.

0900d80580548a7f 3

Installing Flexi BTS modules in the BS-241 II Service Shelter

Id:0900d80580548a7f

Table of ContentsThis document has 54 pages.

1 Introduction to the installation of Flexi BTS in a BS-241 II Service Shelter . 7

2 Preparing BS-241 II Service Shelter for Flexi BTS module installation before shutdown. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

3 Switching off the Node B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

4 Preparing BS-241 II Service Shelter for Flexi BTS module installation after shutdown. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

5 Preparing Flexi BTS modules for BS-241 II Service Shelter installation. . . 27

6 Installing the Flexi rack inside BS-241 II Service Shelter . . . . . . . . . . . . . . 38

7 Installing Flexi BTS modules in BS-241 II Service Shelter. . . . . . . . . . . . . 43

8 Installing the batteries. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

9 Cabling Flexi BTS modules in BS-241 II Service Shelter . . . . . . . . . . . . . . 47

10 Appendix A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

40900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d80580548a7f

List of FiguresFigure 1 Overview of the BS-241 II Service Shelter before Flexi BTS installation . 8Figure 2 Disconnecting the grounding cable from the inside of the plinth front plate.

9Figure 3 Ten nuts that are holding the filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Figure 4 Removing the filter from the door.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Figure 5 Installing the adapter plate.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Figure 6 Turning off the two switches located above the batteries. . . . . . . . . . . . 13Figure 7 Fuses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Figure 8 DC breaker.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Figure 9 Fan breakers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Figure 10 AC power switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Figure 11 Unplugging the cables from the batteries . . . . . . . . . . . . . . . . . . . . . . . . 17Figure 12 Unscrewing the power adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Figure 13 Six nuts that are holding the battery rack.. . . . . . . . . . . . . . . . . . . . . . . . 19Figure 14 Removing the battery rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Figure 15 Installing the gasket to the rear wall of the cabinet. . . . . . . . . . . . . . . . . 20Figure 16 Unplug the power cord.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Figure 17 Old bottom plate without the heater. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Figure 18 Seven screws that are holding the cable entry. . . . . . . . . . . . . . . . . . . . 22Figure 19 Eight screws that are holding the bottom plate. . . . . . . . . . . . . . . . . . . . 23Figure 20 New bottom plate with all the parts installed. . . . . . . . . . . . . . . . . . . . . . 23Figure 21 Fixing the bottom plate.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Figure 22 Fixing the heater. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Figure 23 Plugging the power cord to the heater. . . . . . . . . . . . . . . . . . . . . . . . . . . 26Figure 24 Removing the fan screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Figure 25 Arrow marking on the fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Figure 26 Flipping the fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Figure 27 Fixing the fan screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Figure 28 Gluing the sticker to the fan carrier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Figure 29 Gluing the sticker to the fan handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Figure 30 Removing the fan carrier. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Figure 31 Removing the fan screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Figure 32 Arrow marking on the fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Figure 33 Flipping the fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Figure 34 Fixing the fan screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Figure 35 Fan screws properly fixed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Figure 36 Gluing the sticker to the fan carrier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Figure 37 Gluing the sticker to the fan handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Figure 38 Stripping the Flexi BTS module casing . . . . . . . . . . . . . . . . . . . . . . . . . . 36Figure 39 Fixing cage nuts to the Flexi rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Figure 40 Routing the fan cables behind the fixing bar. . . . . . . . . . . . . . . . . . . . . . 38Figure 41 Connecting the fan cables to the AD panel. . . . . . . . . . . . . . . . . . . . . . . 39Figure 42 Installing the Flexi rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Figure 43 Fixing the side plate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Figure 44 Installed the Flexi rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Figure 45 Inserting fans to Flexi racks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

0900d80580548a7f 5

Installing Flexi BTS modules in the BS-241 II Service Shelter

Id:0900d80580548a7f

Figure 46 Position of the cage nuts for the battery rack. . . . . . . . . . . . . . . . . . . . . 44Figure 47 Baterries placed on the battery rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Figure 48 Fixing the power adapter to the battery rack.. . . . . . . . . . . . . . . . . . . . . 46Figure 49 Taking the rings off the 75 Ohm transmission cables. . . . . . . . . . . . . . . 47Figure 50 Fixing the 120 Ohm cable to the transmission plate. . . . . . . . . . . . . . . . 49Figure 51 Fixing the cables to the cable tie plate. . . . . . . . . . . . . . . . . . . . . . . . . . 50Figure 52 Fixed transmision plate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51Figure 53 Route the antenna jumper cables through the cabling plate and mark them

for peeling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51Figure 54 Peel the antena jumper cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52Figure 55 Fixing the cable entry to the bottom plate. . . . . . . . . . . . . . . . . . . . . . . . 52Figure 56 Installing the plinth front plate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

60900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d80580548a7f

0900d80580548a7f 7

Installing Flexi BTS modules in the BS-241 II Service Shelter

Introduction to the installation of Flexi BTS in a BS-241II Service Shelter

Id:0900d80580548993

1 Introduction to the installation of Flexi BTS in a BS-241 II Service ShelterThis document provides instructions on how to install a Flexi BTS in a BS-241 II Service Shelter. The batteries (or other equipment) on the bottom of the BS-241cabinet is dis-assembled and replaced with an outdoor installation kit (FMUG), which consists a rack to which Flexi BTS modules are installed. The batteries are reinstalled at the upper part of the BS-241 II Service Shelter, above the Flexi BTS modules. There is space for a maximum of two 3U modules in the rack.

For supported Flexi WCDMA BTS configurations, see Appendix Flexi WCDMA BTS configurations in the Cabling Flexi WCDMA BTS and Creating Configurations document in Nokia Siemens Networks WCDMA RAN System Library.

The on-site activities include preparing the site and equipment, switching off the Node B, disassembling the unnecessary components, and installing and cabling Flexi BTS modules.

Before you start

• Refer to Flexi WCDMA BTS Installation Site Requirements for detailed information on installation prerequisites.

• Check all necessary hardware delivery contents. For the FMUG delivery, see Appendix Contents of the outdoor installation kit (FMUG) delivery.

• Check the antenna jumper cables to make sure that they are sufficiently long.

See the following figure for an overview of the BS-241 II Service Shelter.

80900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d80580548993

Introduction to the installation of Flexi BTS in a BS-241 II Service Shelter

Figure 1 Overview of the BS-241 II Service Shelter before Flexi BTS installation

0900d80580548a7f 9

Installing Flexi BTS modules in the BS-241 II Service Shelter

Preparing BS-241 II Service Shelter for Flexi BTS mod-ule installation before shutdown

Id:0900d805805489b7

2 Preparing BS-241 II Service Shelter for Flexi BTS module installation before shutdownSteps

1 Remove the plinth front plateDisconnect the grounding cable from the inside of the plinth front plate.

Figure 2 Disconnecting the grounding cable from the inside of the plinth front plate.

2 Replace the membrane filter from the door.

1. Unscrew the ten nuts that are holding the filter and save them.

100900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d805805489b7

Preparing BS-241 II Service Shelter for Flexi BTS mod-ule installation before shutdown

Figure 3 Ten nuts that are holding the filter.2. Remove the filter from the door.

0900d80580548a7f 11

Installing Flexi BTS modules in the BS-241 II Service Shelter

Preparing BS-241 II Service Shelter for Flexi BTS mod-ule installation before shutdown

Id:0900d805805489b7

Figure 4 Removing the filter from the door.3. Install the adapter plate with new filter using the ten nuts from the door filter.

120900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d805805489b7

Preparing BS-241 II Service Shelter for Flexi BTS mod-ule installation before shutdown

Figure 5 Installing the adapter plate.

0900d80580548a7f 13

Installing Flexi BTS modules in the BS-241 II Service Shelter

Switching off the Node B

Id:0900d805805489d7

3 Switching off the Node B

Steps

1 Turn off the two switches located above the batteries.

Figure 6 Turning off the two switches located above the batteries.

2 Turn off the fuses.

!Follow all applicable national regulations to ensure the safety of personel and to prevent damage to the equipment.

!There is a hazardous energy level present even if the batteries are switched off. Take care when handling the batteries.

140900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d805805489d7

Switching off the Node B

Figure 7 Fuses.

3 Turn off the DC and Fan breakers.

Figure 8 DC breaker.

0900d80580548a7f 15

Installing Flexi BTS modules in the BS-241 II Service Shelter

Switching off the Node B

Id:0900d805805489d7

Figure 9 Fan breakers.

4 Switch off the AC power, if applicable.

Figure 10 AC power switch

160900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d805805489d7

Switching off the Node B

5 Verify that there is no voltage at the input and that the batteries have been discon-nected.Use a multi meter to check the voltage

0900d80580548a7f 17

Installing Flexi BTS modules in the BS-241 II Service Shelter

Preparing BS-241 II Service Shelter for Flexi BTS mod-ule installation after shutdown

Id:0900d805805489d5

4 Preparing BS-241 II Service Shelter for Flexi BTS module installation after shutdowng A minimum height of a 51 cm is required to install the rack for two 3U height Flexi

modules. If there is enough space in the BS-241 II Service Shelter already, there is no need to uninstall or remove the equipment.

Steps

1 Remove the batteries and the battery rack

1 Unplug the cables from the batteries.

Figure 11 Unplugging the cables from the batteries

2 Unscrew the power adapter.

!Be careful to use only electrical isolated tools and remeber to isolate the unplugged batterry cables.

180900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d805805489d5

Preparing BS-241 II Service Shelter for Flexi BTS mod-ule installation after shutdown

Figure 12 Unscrewing the power adapter.

3 Take the batteries out.

4 Unscrew the six nuts on the both sides that are holding the battery rack.

0900d80580548a7f 19

Installing Flexi BTS modules in the BS-241 II Service Shelter

Preparing BS-241 II Service Shelter for Flexi BTS mod-ule installation after shutdown

Id:0900d805805489d5

Figure 13 Six nuts that are holding the battery rack.

5 Remove the battery rack.

200900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d805805489d5

Preparing BS-241 II Service Shelter for Flexi BTS mod-ule installation after shutdown

Figure 14 Removing the battery rack.

6 Remove air blocking plates from cabinet rear wall.

7 Install gaskets to cabinet rear wall around air outlet.

g Note that upper gasket must cover the highest row of the square holes.

Figure 15 Installing the gasket to the rear wall of the cabinet.

0900d80580548a7f 21

Installing Flexi BTS modules in the BS-241 II Service Shelter

Preparing BS-241 II Service Shelter for Flexi BTS mod-ule installation after shutdown

Id:0900d805805489d5

8 Remove the side plate from the left side of the fixing bar, by unscrewing two screws and save them.

2 Remove the heater

1 Unplug the power cord from the heater.

Figure 16 Unplug the power cord.

2 Unscrew the two screws on the both sides that are holding the heater and save them.

3 Remove the heater.

Figure 17 Old bottom plate without the heater.

3 Replacing bottom plate

g Note that replacing bottom plate is needed only if original bottom plate cannot support all cables.

220900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d805805489d5

Preparing BS-241 II Service Shelter for Flexi BTS mod-ule installation after shutdown

1 Remove all the parts from the bottom plate.

g Note that all connections (especially AC connections) should be marked for the correct connection points. Person who does the installation must be qualified for that work.

2 Unscrew the seven screws that are holding the cable entry and save them.

Figure 18 Seven screws that are holding the cable entry.

3 Remove the cable entry and save it.

4 Remove cables from the cable entry.

5 Unscrew eight screws that are holding the bottom plate and save them.

0900d80580548a7f 23

Installing Flexi BTS modules in the BS-241 II Service Shelter

Preparing BS-241 II Service Shelter for Flexi BTS mod-ule installation after shutdown

Id:0900d805805489d5

Figure 19 Eight screws that are holding the bottom plate.

6 Install all the the parts back on the new bottom plate according to figure below..

Fix the cables on the back of bottom plate by cables ties.

Re-use the EMI gasket from the old bottom plate for the new one.

Figure 20 New bottom plate with all the parts installed.

7 Install the new bottom plate.

8 Use the eight screws from the old bottom plate to fix the new bottom plate.

240900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d805805489d5

Preparing BS-241 II Service Shelter for Flexi BTS mod-ule installation after shutdown

Figure 21 Fixing the bottom plate.

0900d80580548a7f 25

Installing Flexi BTS modules in the BS-241 II Service Shelter

Preparing BS-241 II Service Shelter for Flexi BTS mod-ule installation after shutdown

Id:0900d805805489d5

4 Install the heater

1 Use the two screws to fix the heater on the second slot from the bottom of the fixing bar.

Figure 22 Fixing the heater.

2 Plug the power cord to the heater.

260900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d805805489d5

Preparing BS-241 II Service Shelter for Flexi BTS mod-ule installation after shutdown

Figure 23 Plugging the power cord to the heater.

0900d80580548a7f 27

Installing Flexi BTS modules in the BS-241 II Service Shelter

Preparing Flexi BTS modules for BS-241 II ServiceShelter installation.

Id:0900d805805489d6

5 Preparing Flexi BTS modules for BS-241 II Service Shelter installation.Changing the fan air flow direction for a plastic fan carrier

PurposeThe air flow direction of the Flexi BTS modules must be changed before installing the modules to a BS-241cabinet. The plastic fan carrier does not need to be removed but instead the fans can be flipped while the fan carrier remains in place.

To shorten the BTS downtime, this procedure can be performed in advance.

Steps

1 Remove the module core from the casing.

2 Remove the fan screws (four on each fan).

Figure 24 Removing the fan screws

3 Flip the fans upside down.Pay attention to the arrow markings on the fans. They show the air flow direction. Make sure that the arrows are pointing towards the back of the module.

280900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d805805489d6

Preparing Flexi BTS modules for BS-241 II Service Shelter installation.

Figure 25 Arrow marking on the fan

Figure 26 Flipping the fans

0900d80580548a7f 29

Installing Flexi BTS modules in the BS-241 II Service Shelter

Preparing Flexi BTS modules for BS-241 II ServiceShelter installation.

Id:0900d805805489d6

4 Fix the screws back in place.The tightening torque is 1 Nm.

Figure 27 Fixing the fan screws

5 Glue the sticker included in the delivery to its place.

Figure 28 Gluing the sticker to the fan carrier

300900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d805805489d6

Preparing Flexi BTS modules for BS-241 II Service Shelter installation.

Figure 29 Gluing the sticker to the fan handle

Keep the spare stickers in the site documentation folder.

Changing the fan air flow direction for a sheet metal fan carrier

PurposeThe air flow direction of the Flexi BTS modules must be changed before installing the modules to a NB 441/881 cabinet.

To shorten the BTS downtime, this procedure can be performed in advance.

0900d80580548a7f 31

Installing Flexi BTS modules in the BS-241 II Service Shelter

Preparing Flexi BTS modules for BS-241 II ServiceShelter installation.

Id:0900d805805489d6

Steps

1 Remove the module core from the casing.

2 Remove the fan carrier

Figure 30 Removing the fan carrier

320900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d805805489d6

Preparing Flexi BTS modules for BS-241 II Service Shelter installation.

3 Remove the fan screws (four on each fan).

Figure 31 Removing the fan screws

4 Flip the fans upside down.Pay attention to the arrow markings on the fans. They show the air flow direction. Make sure that the arrows are pointing towards the back of the module.

0900d80580548a7f 33

Installing Flexi BTS modules in the BS-241 II Service Shelter

Preparing Flexi BTS modules for BS-241 II ServiceShelter installation.

Id:0900d805805489d6

Figure 32 Arrow marking on the fan

Figure 33 Flipping the fans

340900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d805805489d6

Preparing Flexi BTS modules for BS-241 II Service Shelter installation.

5 Fix the screws back in place.The tightening torque is 1 Nm.

Figure 34 Fixing the fan screws

Make sure that the screws go all the way to the bottom.

Figure 35 Fan screws properly fixed

6 Reinstall the fan carrier.Tighten to 2.2 Nm.

0900d80580548a7f 35

Installing Flexi BTS modules in the BS-241 II Service Shelter

Preparing Flexi BTS modules for BS-241 II ServiceShelter installation.

Id:0900d805805489d6

7 Glue the sticker included in the delivery to its place.

Figure 36 Gluing the sticker to the fan carrier

Figure 37 Gluing the sticker to the fan handle

Keep the spare stickers in the site documentation folder.

360900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d805805489d6

Preparing Flexi BTS modules for BS-241 II Service Shelter installation.

Preparing Flexi BTS modules for the BS-241 II Service Shelter installation.

PurposeTo shorten the BTS downtime, this procedure can be performed before switching off the Node B.

Steps

1 Remove the fixing studs from the Flexi BTS module casings.

Figure 38 Stripping the Flexi BTS module casing

2 Remove the cable support plates from the module casings.

3 Loosen the module core fixing screws.

4 Detach the cage nuts and support plates behind them from the module casings.

5 Remove fans before rack installation:

6 Prepare the rack for cabinet installation:

• Remove the bottommost cable grommets from the bottom of the rack. Pierce the grommets.

• Fix the cage nuts to the rack according to your configuration.

0900d80580548a7f 37

Installing Flexi BTS modules in the BS-241 II Service Shelter

Preparing Flexi BTS modules for BS-241 II ServiceShelter installation.

Id:0900d805805489d6

Figure 39 Fixing cage nuts to the Flexi rack.

380900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d80580548a7a

Installing the Flexi rack inside BS-241 II Service Shelter

6 Installing the Flexi rack inside BS-241 II Service ShelterBefore you startIf the temperature sensor is installed on the position sixteenth or lower from the bottom of the fixing bar, it needs to be relocated to position seventeenth or higher from the bottom of the right side of the fixing bar.

g Remove the fans from Flexi rack before the installation to improve installation speed.

Steps

1 Relocate the cage nuts to positions: fifth, tenth and fifteenth from the bottom on both sides of of the fixing bar.

Fix one additional cage nut on both sides. One to the fourth hole on the left and one to the eighteenth hole on the right.

2 Before installing Flexi rack to the BS-241 II Service Shelter, route the fan cables behind the fixing bar on the left side.

Figure 40 Routing the fan cables behind the fixing bar.

3 Remove two screws on the AD panel and pull it slighly out of the rack. Route the fan cables on the left side to the back of AD panel and connect them.

Push the AD panel back and fix it by two screws.

Fix the extra cable on the left side.

g If it is possible to remove the rear wall of the cabinet, then it is easier to route and fix the fan cables on rear side of AD panel.

0900d80580548a7f 39

Installing Flexi BTS modules in the BS-241 II Service Shelter

Installing the Flexi rack inside BS-241 II Service Shelter

Id:0900d80580548a7a

Figure 41 Connecting the fan cables to the AD panel.

4 Install the Flexi rack inside the BS-241 II Service Shelter, by placing the fitting claws on the position sixteenth from the bottom of the fixing bar.

Ensure that rack is correctly located. Cabinet rear wall air vents are located at rack fan exhaust.

400900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d80580548a7a

Installing the Flexi rack inside BS-241 II Service Shelter

Figure 42 Installing the Flexi rack.

5 Fix the side plate on positions fourth and fifteenth from the bottom of the left side of the fixing bar.

0900d80580548a7f 41

Installing Flexi BTS modules in the BS-241 II Service Shelter

Installing the Flexi rack inside BS-241 II Service Shelter

Id:0900d80580548a7a

Figure 43 Fixing the side plate.

6 Fix the Flexi rack with a long screwdriver (minimum 25 cm/9.8 in) on the positions of the cage nuts (fifth, tenth and fifteenth).

420900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d80580548a7a

Installing the Flexi rack inside BS-241 II Service Shelter

Figure 44 Installed the Flexi rack.

0900d80580548a7f 43

Installing Flexi BTS modules in the BS-241 II Service Shelter

Installing Flexi BTS modules in BS-241 II Service Shel-ter.

Id:0900d805805489eb

7 Installing Flexi BTS modules in BS-241 II Service Shelter.Installing Flexi BTS modules in the BS-241 II Service Shelter

Before you startIf applicable, remove the Flexi BTS module cable entries. They are not used in cabinet installations.

Steps

1 Reinstall the fans to the slots in the Flexi rack.

Figure 45 Inserting fans to Flexi racks

2 Install the module casings to the racks.

3 Connect the DC power cable from the suitable DC output of AD panel to the System Module.

4 Insert the module cores to the casings.

!Electrostatic discharge (ESD) might damage the modules. Wear an ESD wrist strap or use a corresponding method when handling the modules. The ESD wrist strap does not work before the cabinet is earthed (grounded).

440900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d805805489d3

Installing the batteries.

8 Installing the batteries.Only applicable if the batteries were removed see Preparing the BS-241 cabinet for Flexi BTS module installation after shutdown.

Steps

1 Relocate the cage nuts to positions twenty second, twenty sixth and thirtieth from the bottom of both sides of the fixing bar.

2 Install the battery rack on the position and fix itwith a long screwdriver (minimum 25 cm/9.8 in) on the positions of the cage nuts (twenty second, twenty sixth and thirtieth)

Figure 46 Position of the cage nuts for the battery rack.

0900d80580548a7f 45

Installing Flexi BTS modules in the BS-241 II Service Shelter

Installing the batteries.

Id:0900d805805489d3

3

Place the batteries back at the battery rack.

Figure 47 Baterries placed on the battery rack.

4 Fix the power adapter back back to the battery rack.

!Be careful to use only electrical isolated tools and remeber to isolate the unplugged batterry cables.

460900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d805805489d3

Installing the batteries.

Figure 48 Fixing the power adapter to the battery rack.

5 Make the battery connections according to manufacturers instructions.

0900d80580548a7f 47

Installing Flexi BTS modules in the BS-241 II Service Shelter

Cabling Flexi BTS modules in BS-241 II Service Shelter

Id:0900d805805489d2

9 Cabling Flexi BTS modules in BS-241 II Service ShelterBefore you startFor Flexi WCDMA BTS module cabling instructions, see the Cabling Flexi WCDMA BTS and Creating Configurations document in Nokia Siemens Networks WCDMA RAN System Library.

The transmission and antenna jumper cables are sensitive. Handle them with care.

FTCU installation

1 Take the rings off the 75 Ohm transmission cables and save them.

Figure 49 Taking the rings off the 75 Ohm transmission cables.

2 Remove the plastic foil from the connecting area on the transmission plate.

480900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d805805489d2

Cabling Flexi BTS modules in BS-241 II Service Shelter

3 Route the end of the 75 Ohm transmission cables through transmission plate, and fix them on the other side with the rings.

FTCM installation

1 Remove the plastic foil from the connecting area on the transmission plate.

2 Remove the sheet metal “knock-out” from transmission plate by putting a screw driver on the hole in the middle of “knock-out” and twisting it slightly.

0900d80580548a7f 49

Installing Flexi BTS modules in the BS-241 II Service Shelter

Cabling Flexi BTS modules in BS-241 II Service Shelter

Id:0900d805805489d2

3 Fix the RJ45 cable adapter (120 Ohm cable) to the opened hole as shown in the figure below.

Figure 50 Fixing the 120 Ohm cable to the transmission plate.

4 Fix the installed cables to the cable tie plate.

500900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d805805489d2

Cabling Flexi BTS modules in BS-241 II Service Shelter

Figure 51 Fixing the cables to the cable tie plate.

5 Fix the transmission plate to the bottom plate, with the cables to the right side.

0900d80580548a7f 51

Installing Flexi BTS modules in the BS-241 II Service Shelter

Cabling Flexi BTS modules in BS-241 II Service Shelter

Id:0900d805805489d2

Figure 52 Fixed transmision plate.

Antenna cables installation

1 Route the antenna jumper cables through the cabling plate and mark them for peeling.

Figure 53 Route the antenna jumper cables through the cabling plate and mark them for peeling.

2 Take off the antenna jumper cables, and peel them.

520900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d805805489d2

Cabling Flexi BTS modules in BS-241 II Service Shelter

Figure 54 Peel the antena jumper cables.

3 Route the peeled antenna jumper cables through the cable entry and fix the cables to entry by cable ties.

Fix the cable entry to the bottom plate.

Figure 55 Fixing the cable entry to the bottom plate.

4 Install the plinth front plate cover and fix the grounding cable.

Figure 56 Installing the plinth front plate.

0900d80580548a7f 53

Installing Flexi BTS modules in the BS-241 II Service Shelter

Appendix A

Id:0900d80580548fbc

10 Appendix AA.1 AbbreviationsAC alternating current

BTS base transceiver station

DC direct current

ESD electrostatic discharge

FMUG outdoor installation kit

A.2 Contents of the outdoor installation kit (FMUG) delivery

• 1 x Rack Assembly • 1 x Bottom Plate Assembly • 1 x Transmission Plate Assembly (fixed to bottom plate) • 1 x Door Panel • 1 x Membrane Filter CF130162 (fixed to door panel) • 2 x Fan for NB Flexi GSM • 1 x Cable Binding Plate • Power Cable • 1 x Dummy panel • 2 x Rear Seal Long (8x20x455mm) • 2 x Rear Seal Side Short (8x20x120mm) • 15 x CABLE TIE 140x3,6mm • 6 x Cage nut M6 FOR 9,5x9,5mm HOLE • 1 x Handle Sticker Sheet • 1 x CE Label Covering Sticker

A.3 Installation check list

A.4 Installation tools

• Torque wrench for 7/16 DIN antenna cable connectors • Torx T8, T10, T15, T20, T30 (or T27, with minimum 23 cm (9.1 in) length) tip screw-

drivers • Set of flat blade screwdrivers (for alarm screw terminals; DC breakers, etc) • Side cutters

Installation phase Result

The delivery is complete and undamaged

All the necessery switches are on

The relevant stickers are in place

Flexi fans air flow direction is correct

The back wall is installed and fixed in place

The cabinet is grounded

The cable connector seals are firmly in place

540900d80580548a7f

Installing Flexi BTS modules in the BS-241 II ServiceShelter

Id:0900d80580548fbc

Appendix A

• Cable stripper • Crimping tool for RJ45 connectors (used for 120?E1 RJ48) • ESD wrist band and cable (for fan control PWB ) • 10 mm (3.9 in) socket wrench • Knife • Multi meter • Monkey wrench • Spanner 7-32 mm • Flashlight