instruction manual - clever
TRANSCRIPT
INSTRUCTIONMANUAL
BLACK LABEL CLEVERSPA UNIVERSAL IM_VERSION 1.indd 1 18/10/2019 15:01
Safety Instructions 02 - 03
Black Label CleverSpa® Parts Checklist 05
Before you set up Black Label CleverSpa® 06 - 07
Setting up Black Label CleverSpa® 08 - 09
Operating your Black Label CleverSpa® / CleverLink App Setup 10
Maintenance & Repair of Black Label CleverSpa® 11
Cleaning & Storing away Black Label CleverSpa® 12
Troubleshooting 13
Returns 14
Warranty 15
02
CONTENTS
SAFETY INSTRUCTIONS - READ CAREFULLY!When installing and using this electrical equipment, there are basic safety precautions that should always be followed:
• Applianceshouldbesuppliedthrougharesidualcurrentdevice(RCD/GFCItype)witharatedtrippingcurrentnotexceeding30mA.
• Electricinstallationsshouldfulfiltherequirementsoflocalstandards.Earthedappliancesmustbepermanentlyconnectedtofixedwiring.
• Anydamagetoelectricalcableshouldbereplacedbyacompetentpartyimmediatelybeforefurtheruse.
• It’srecommendednottouseanextensioncordtoconnecttheCleverSpa®toelectricalsupply.
• RISK OF ELECTRIC SHOCK.Neveroperateanyexternal/additionalelectricalappliancewhenintheCleverSpa®orwhenyourbodyiswet.KeepelectricalappliancesawayfromtheCleverSpa®.
• RISK OF ACCIDENTAL DROWNING.ChildrenareforbiddenfromusingtheCleverSpa®unlesstheyaresupervisedatalltimesbyaresponsibleadult.
• Forhealthandsafetyreasons,wedonotrecommendchildrenunder8yearsolduseourhottubs.Forchildren8years+werecommendthetemperaturebesetnohigherthan37°C.
• Whennotinuse,covershouldbefittedandlockedtohelpretainheat.ThisalsopreventsunsupervisedchildrenaccessingtheCleverSpa®.
• ShowerbeforeusingyourCleverSpa®.Cosmeticproducts,lotionsetconskincandegrade waterquality.
• DonotswitchonifthereisanypossibilitythatwaterintheCleverSpa®orcontrolsystemisfrozen.
• PetsshouldbekeptawayfromyourCleverSpa®atalltimes.
• Soakinginhotwaterduringpregnancycancausedamagetotheunbornfoetus.Ifyouhaveanyspecificconcernspleaseconsultyourdoctorbeforecontinuingtouseyourhottub.
• Useofalcohol,drugsormedicationbeforeorduringuseofyourCleverSpa®canincreaseriskofdrowning.
BLACK LABEL CLEVERSPA UNIVERSAL IM_VERSION 1.indd 2 18/10/2019 15:01
03
SAFETY INSTRUCTIONS
WARNING - PLEASE READ CAREFULLY!Do not operate pump and heating system whilst the CleverSpa® is empty.
This can damage the system and void your warranty.
• Thosewithhistoryofheartdisease,low/highbloodpressure,circulatorysystemproblemsordiabetesshouldconsultadoctorbeforeusingCleverSpa®.PeopleusingmedicationshouldconsulttheirdoctorbeforeusingtheCleverSpa®.Somemedicationsmaycausedrowsiness,whilstothermedicationmayaffectheartrate,bloodpressureandcirculationduringuse.
• WaterinaCleverSpa®shouldneverexceed42°C (107°F).Operatingtemperaturesbetween38-40OC (100-104°F)areconsideredsafeforahealthyadult.Lowertemperaturesarerecommendedforyoungerchildren,andwhenuseexceeds10continuousminutes.
• Amaxtemperatureof42OCcanbeprogrammedforthewater-Oncecoverisremoved,watertemperaturewillautomaticallydropasheatisreleasedthroughevaporation.Theadditional2OCcompensatesforheatlossthatmayoccur.Onceyouarereadytouse,reducemaximumtemperaturetorecommended38-40OC(100-104°F)andensurethattemperaturereadingisnogreaterthan40OC.
• ImmediatelygetoutofyourCleverSpa®ifyoufeeluncomfortableorsleepy.
• DonotturnCleverSpa®onwhenitisempty.Thiscouldcauseirreparabledamagetopumpsystemwhichwouldnullifyanywarrantyperiod.
• Toavoiddamagingyourpump&heatingsystemduringcolderweather,yourCleverSpa®isfittedwith365 FreezeGuardTechnology.Setthetemperatureto5OC,andthiswillpreventanywaterinthesystemfromfreezing.
• Alwaysaddchemicalstojugofwatertoavoidstrongfumesorviolentreactionsthatmayresultinahazardouschemicalspray.
• Toavoidaccidentalresettingofthermalcut-out,thisappliancemustnotbesuppliedthroughanexternalswitchingdevice,suchasatimer,orconnectedtoacircuitthatisregularlyswitchedonandoffbytheutility.
• WARNING:Adequatedrainagehastobeprovidedtodealwithoverflowofwater.
• IMPORTANT:Forset-up/installation,thesurfacemustbesmooth,flat,levelandcapableofevenlysupportingtheweightoftheCleverSpa®,wateranduserse.g.6PersonSquareCleverSpa®filledweight:980kg(approx)pluscombinedweightofoccupants.
It is the responsibility of the CleverSpa® owner to assure integrity of the site at all times.
BLACK LABEL CLEVERSPA UNIVERSAL IM_VERSION 1.indd 3 18/10/2019 15:01
04
BLACK LABEL CLEVERSPA UNIVERSAL IM_VERSION 1.indd 4 18/10/2019 15:01
05
Please check all parts are present in your box before first use.To order new or missing parts please visit: clevercompany.com
BLACK LABEL CLEVERSPA® PARTS CHECKLIST
EXTERNAL PUMP/HEATER UNIT
(B)
BLACK LABEL CLEVERSPA® (A)
HAND PUMP PRESSURE GAUGE
(E)
HIGH PRESSURE INFLATION HOSE
(F)
REPAIR PATCHES
(M)
DRAINAGE PLUG (K)
FILTER PROTECTOR COVER
(L)
VALVE WRENCH
(N)
FILTER CARTRIDGE
(G)
CLIP-ON TOP COVER
(H)
SAFETY LOCKING CLIP KEYS
(I)
PVC GROUNDSHEET
(J)
HOSES/ CONNECTORS X3
(D)
DUAL ACTION HIGH PRESSURE HAND PUMP
(C)
PRODUCT SPECIFICATION
Capacity
Water Capacity to ‘Max’ line (approx.)
Actual Water Flow (approx.)
Inflated Size (approx.)
Product Weight (approx.)
Filled Weight (approx.)
No. of Air Jets
Pump Voltage
Maximum Temperature
Temperature Rise (approx.)
Rated Power Input for Heating
Rated Power Input for Bubbling
Rated Current (Combined)
Heating / Filtering
Bubbling
180CM CIRCULAR
Up to 7 People
1020L
1,325L/H
180 x 65cm
28.75kgs
1050kgs
140
220-240V–50Hz
42°C (107°F)
1.5-2°C/hr
1800W
600W
10.4A
7.8A
2.6A
BLACK LABEL CLEVERSPA UNIVERSAL IM_VERSION 1.indd 5 18/10/2019 15:02
06
BEFORE YOU SET UP BLACK LABEL CLEVERSPA®
If your WiFi signal is poor all over your garden, please contact your internet provider for further assistance.
Before setting up your CleverSpa® with CleverLink - find a strong WiFi signal
DISTANCE FROM HOUSE
1. You must have solid support foundation where you install your CleverSpa®. When setting up, ensure there are no sharp objects that could damage the CleverSpa® and the location is level so the CleverSpa® sits properly.
2. During filling, emptying or when in use, water may spill out. You should install it near to a drainage point that is able to accept the total volume of water.
3. Do not leave the surface of the CleverSpa® exposed to direct sunlight for long periods of time as this may affect the strength of the welds.
Before setting up outdoors1. Floor must be able to withstand
weight of the CleverSpa® + occupants.
2. Floor should be a non-slip, level surface.
3. Suitable drainage is essential when installing your CleverSpa® indoors.
Carefully consider the placement of your hot tub before installation.
Before setting up indoors
42
WIFI STRENGTHSTRONG
42
WIFI STRENGTHFAIR
42
WIFI STRENGTHWEAK
WIFI STRENGTHSTRONG
BLACK LABEL CLEVERSPA UNIVERSAL IM_VERSION 1.indd 6 18/10/2019 15:02
07
BLACK LABEL CLEVERSPA UNIVERSAL IM_VERSION 1.indd 7 18/10/2019 15:02
08
SETTING UP BLACK LABEL CLEVERSPA®
8
Inflationtakes2minutes(approx).Note:DrainageOutlet(T) shouldbepositionedonoutsideofthehottub.
Usedualactionhandpump(C) toinflate.(Air pressure 7PSI).
7
Onceinflatedturnanti-clockwisetoreleaseinflationhose
andreplacevalvecap(W).
9
J
1
Laygroundsheet (J) onaflat,evensurface,clearofsharpobjects.
UnpackCleverSpa® (A)ongroundsheet.
2
Removeprotectiveplasticfromclips&connectors.
3
AssembleHandPump(C),PressureGauge(E)&Hose(F).
Insertandtwistuntillocked.
5
LocateInflationValve.Removevalvecap(W).Connecthose(F)
turningclockwisetolock.Central button MUST be up.
6
(P)InflationValve,(Q)AirjetConnector,(S)WaterInlet,(R)WaterOutlet(T)DrainageOutlet.
PR
S
Q
T
4
Alignhoseswithrespectiveconnectorsandscrewintoplace.
Plugin,switchon.
11
Unpackexternalunit(B)screw3xhoses(D)ontoexternalunit
inordershown.
10
2
3
1
Inner features: WaterCirculationOutlet(U)FilterConnector(V)DrainagePlug(K).
U
V
K
12
CENTRAL BUTTONPOSITION
83
W
F
BLACK LABEL CLEVERSPA UNIVERSAL IM_VERSION 1.indd 8 18/10/2019 15:02
SETTING UP BLACK LABEL CLEVERSPA®
ScrewFilterCartridge(G) ontoFilterConnector(V).
AddFilterProtectorCover(L) ontoFilterCartridge(G).
G
Addwatertolevel.Nohigherthan‘MAX’level.
Clip-onTopCover(H)toretaintheheat.
Settemperatureoncontrolpanel.See page 10 for full operating instructions.
DoublelockclipswithSafetyLockingKeys (I).
V
09
M
1513
1716
14
18
W
P
N
Overtimeinflationvalve(P)maybecomeloose.Usesuppliedvalvewrench(N)totighten,maintainingairseal.
FOLLOW THE STEPS 19 & 20 BELOW:
IMPORTANT: WHILST USING THE WRENCH - DO NOT LOOSEN VALVE AS IT WILL FAIL.
TIGHTENING INFLATION VALVE
19 20
BLACK LABEL CLEVERSPA UNIVERSAL IM_VERSION 1.indd 9 18/10/2019 15:02
10
OPERATING YOUR BLACK LABEL CLEVERSPA®
SETTING THE TEMPERATURE
Press‘SET TEMP/LOCK’andthenumbersondisplayscreenwillstarttoflash.Increase/decreasetemperaturebypressing‘TEMP UP’ or‘TEMP DOWN’.
Choosedesiredtemperature,press‘SET TEMP/LOCK’againtoconfirm.Temperaturescanbesetbetweentherangeof5°C to 42°C.
(See safety instructions for recommended operating temperatures).
INFLATE/AIR JETS
Press‘INFLATE/AIR JETS’tostartairjets-aredlightwillappear.Pressagainandairjetswillstopworking-redlightwillgoout.
Airjetsstopautomaticallyafter20minutes.Toreset,waitfor10minutesandpress‘INFLATE/AIR JETS.Airjetscanbestopped/startedanytimeduringtheir20minutecycle.
Air Jets will stop after 20 minutes to avoid internal pump over-heating.
CONNECTING YOUR CLEVERLINK APP
1.CheckthatyourCleverSpa®isinalocationwithstrongWiFicoverage(seepage06).
2.DownloadtheCleverLinkApponyourSmartdevice,fromtheAppStoreorGooglePlay.
3.Registeryouraccount.
4.FollowonscreeninstructionsregardinghowtopairCleverSpa®
toyourWiFi.
5.Youarereadytogo! *Internet access required.
FILTRATION SYSTEM
Press‘FILTER’,redlightwillappear,pumpwillstarttowork.Press‘FILTER’againtostoppump,redlightwillgoout.
Afterapprox.168hours,‘FC’willappearondisplayscreen(flashing),withawarningtone.Redlightwillbeliton‘FILTER’,pumpwill notbeoperational.Heatingsystemwillalsonotworkandredlightwillbeoff.
Tomakesurefiltrationsystemisoff,press‘FILTER’.‘FC’ondisplayscreenwilldisappearaswellaswarningtone.Watertemperaturewillbedisplayed,allfunctionswillreturntonormal.‘FC’andwarningtoneremindusertoreplacefilter.
‘FILTER CHANGE’
HEATER
Press‘HEATER’,redlightwillappear.Press‘HEATER’againandheatingsystemwillstop,redlightwillgoout.
Whenheatersystemison,filtersystemwillswitchonautomaticallytocirculatewater.Whentemperaturehasreached1°C abovepre-settemperature,heatingsystemwillstopworking,butlightwillremainon.Filterpumpwillcontinuetooperateevenwhenheaterisnotfunctioning.
Whenwaterfalls1°Cbelowpre-settemperature,heatingsystemwillautomaticallyheatwaterbackto1°C above selectedtemperature.Onceachieved,heaterwillstoptoallowtemperaturetosettleatpre-setvalue.
BLACK LABEL CLEVERSPA UNIVERSAL IM_VERSION 1.indd 10 18/10/2019 15:02
11
MAINTENANCE & REPAIR OF BLACK LABEL CLEVERSPA®
WATER LEVEL
Watershouldbefilledandmaintainedbetween‘Min’and‘Max’filllinesasindicatedoninnerwallofyourCleverSpa®
IMPORTANCE OF WATER TREATMENT
YouneedtoregularlymonitorandappropriatelytreatthewaterinyourCleverSpa®.
PEOPLE WITH THE FOLLOWING TRAITS ARE AT HIGHER RISK INCLUDING:
•Diabetes,lungandheartdisease•Smokersandheavydrinkers•Anyonewithanimpairedimmunesystem•Peoplesufferingfromchronicrespiratoryorkidneydisease.
Formoreinformationcontactyourdoctor.
WATER AND LEGIONNAIRES DISEASE?
Legionnaires’diseasecanbecontractedbyinhalingsmalldropletsofwater(calledaerosols),whicharesuspendedintheairandcontainthebacteria.CertainconditionsincreasetheriskofLegionellaif:
• Watertemperatureinallorsomepartsofthesystemisbetween20-45°C,whichissuitablefor growthofthebacteria.• Itispossibleforbreathablewaterdropletstobecreatedandwaterisstoredand/orre-circulated.• Therearedepositsthatcansupportbacterialgrowthprovidingasourceofnutrientsforthe organisme.g.rust,sludge,scale,organicmatterandbiofilms(fromthebody).
For more information visit: clevercompany.com/support/chemical-maintenance
CLEANING YOUR CLEVERSPA®
Detergentresidues,dissolvedsolidsfrombathingsuitsandchemicalswillgraduallyaccumulateinthewater.TocleanyourCleverSpa®,usesoapandwaterthenrinsethoroughly.
Please note:donotusehardbrushesorabrasivecleaners.
REPAIRING PUNCTURES IN YOUR CLEVERSPA®
IfyourCleverSpa®istorn/punctured,userepairpatches(M).Completelydryareatoberepaired,applystrongadhesivetorepairpatch(M)andthencoverthedamagedarea.Smooththesurfacetoremoveanyairbubbles.Leavetodryfor12hoursbeforeusingtheCleverSpa®.
For more information cleaning and repairing your hot tub visit: clevercompany.com/support/faqs/cleverspa-faqs
BLACK LABEL CLEVERSPA UNIVERSAL IM_VERSION 1.indd 11 18/10/2019 15:02
12
CLEANING & STORING AWAY BLACK LABEL CLEVERSPA®
HOW TO EMPTY YOUR CLEVERSPA®
1. SwitchoffCleverSpa®atelectricalmains.
2.Unscrewcapfromdrainageoutlet(T), locatednearpumpsystemoftheCleverSpa®.Ensuredrainageplug(K)isinsertedtopreventunexpecteddraining.
3. Removedrainageplug(K) fromoutletwithinfloorofCleverSpa®, sowatercanflowout.
4.Oncedraineduseaspongetoabsorbexcesswater.SwitchCleverSpa®on,allowingyoutooperateairjetfunctionforupto20minutes(onefullcycle)todrainwateranddryoutpipeline.Ifnotcompletelydryafterfirstcycle–repeat.
5.Whendraininghasfinished,replacedrainageplug(K)anddrainageoutletcap(T).
6.Disconnectthepump&heatingsystemanddrythoroughly.
STORING YOUR CLEVERSPA®
CompletelydrainwaterfromtheCleverSpa®,pumpandheatingsystem.CleverSpa®shouldbeplacedinbagprovidedandstoredinadryplace,raisedofffloorandawayfromextremetemperatures.
Please note:CorrectstorageisvitaltoextendthelifeofyourCleverSpa®.
HOW TO DEFLATE YOUR CLEVERSPA®
1. Remove filtercartridgeandfiltersock.
2. Locateinflationvalve.
3. Removevalvecap(W)bytwisting90°anti-clockwise.
4. Pressinflationvalve(P)down,twisting90°clockwisetolockinplace,releasingair.
5. Foldawaycarefullyremovingasmuchairaspossiblethroughopenvalve.
6. Whenfullydeflated,turninflationvalve(P) 90°anti-clockwisetoclose–buttonwillpopup.
7. Replacevalvecap(W)andturn90°clockwisetolock.
WARNING!Hot tub is under high pressure.
The air will release quickly, with force.
(P)(W)
(T)
BLACK LABEL CLEVERSPA UNIVERSAL IM_VERSION 1.indd 12 18/10/2019 15:02
13
TROUBLESHOOTING
SOME TIPS TO HELP YOU TO DIAGNOSE AND RECTIFY COMMON SOURCES OF TROUBLE:
PROBLEMS POTENTIAL CAUSES SOLUTIONS
A1 Airpumptoohot
A2 Somethingwrongwithpowerbox
A3 AirPumpincoolingmode
A1 Unplugsystem.Afterairpumphascooled,insertplugandpressairjetsbuttontoactivate
A2 Waitfor10Minutesandrestart
A3 CallCleverSpa®Aftersalesifdoesnotreset
A1 Temperatureissettoolow
A2 Dirtyfiltercartridge
A3 Improperwaterlevels
A4 Heatingelementfailure
A1 Settoahighertemperature(20-42°C) thancurrentwatertemperature
A2 Clean/replacefiltercartridge
A3 Addwatertospecifiedlevels
A4 CallCleverSpa®Aftersalesifdoesnotreset
A1 Dirtyfiltercartridge
A2 Somethingwrongwithpowerbox
A1 Clean/replacefiltercartridge
A2 CallCleverSpa®Aftersalesifitdoesnotreset
A3 Askaprofessionalelectriciantocheckhouseholdelectricalsupplyisfunctioningcorrectly
A1 Insufficientfilteringtime
A2 Dirtyfiltercartridge
A3 Improperwatermaintenance
A1 Increasefiltrationtime
A2 Clean/replacefiltercartridge
A3 Refertochemicalmanufacturer’sinstructions
A1 CleverSpa®istornorpunctured A1 Userepairpatchprovided
CONTROL PANEL ERROR CODES
Air jet system is not operating
Heating system does not operate
Filtering system does not operate / Rattling noise when switching filter on
CleverSpa® leakage
Water not clean
A1 ResidualwaterintheCleverSpa®willcontinuetobeheatedbyresidualtemperature
A2 Waterinletthroughfiltersystemmaybeblocked
A1 Unplugfrommainsandwait.Temperaturewillstarttoreduceandreturntonormal
A2 Cleantheinlet
A3 CallCleverSpa®Aftersalesifdoesnotreset
Display temperature is higher than 42oC, after stopping heating function
CORRECT DISPOSAL OF THIS PRODUCT ThismarkingindicatesthatthisproductshouldnotbedisposedwithotherhouseholdwastethroughouttheEU.Topreventpossibleharmtotheenvironment,orhumanhealthfromuncontrolledwastedisposal,recycleitresponsiblytopromotethesustainablereuseofmaterialresources.Toreturnyouruseddevice,pleaseusethereturnandcollectionsystemsorcontacttheretailerwheretheproductwaspurchased.Theycantakethisproductforenvironmentalsaferecycling.
Code Cause Solution
FC Whenfiltrationsystemhasworkedforapprox.168hours,‘FC’willappearondisplaywithawarningtone.Redlightwillstillbelitonfilter,pumpwillnotbeoperational.Heatingsystemwillnotwork,andredlightwillbeoutonheater.
SL/HL TemperatureIssue
SH WaterTemperatureSensorIssue
Checkfilterandchangeifnecessary.Oncedone,pressfilteragain.‘FC’errorcodewilldisappear,andwarningtonewillstop.Watertemperaturewillbedisplayed,allfunctionswillreturntonormal.
ContactCleverSpa®Aftersaleson+44 (0) 151 318 6163orvisit:clevercompany.com
ContactCleverSpa®Aftersaleson+44 (0) 151 318 6163orvisit:clevercompany.com
BLACK LABEL CLEVERSPA UNIVERSAL IM_VERSION 1.indd 13 18/10/2019 15:02
14
RETURNS
NEED TO RETURN YOUR CLEVERSPA®
? FOLLOW INSTRUCTIONS BELOW:
• Purchased from a UK retailer:CallCleverSpa®AftersalesTeam.Thiswillrequireproofofpurchase.
• Purchased from clevercompany.com:Ifpurchaseddirectlyfromourwebsite,contactusandwewillemailinstructionstoreturnproduct.Contactcanbemadebyemailortelephone-seewarrantyclaimssection.
Whenpostingitemsback,clearlymarkparcelwithordernumberandfullname.Shipunusedproduct,inoriginalpackaging,toaddressidentifiedinouremail.Keepreceipt(s)orordernumbersafe,youwillneeditasproofofpurchaseineventofafter-salesqueries.
POINTS TO NOTE:
• UnderDistanceSellingRegulations,asaconsumeryouhavetherighttocancelyourorderandreturngoodsifwearenotifiedwithinaperiodof14daysafterdeliveryofgoods.
• Youareresponsibleforshippingproductsbacktous.Useatraceableshippingmethod.
• Ifyouchoosetocancelyourorder,werequireyou,theconsumer,topaythecostofreturning theitemtous.
• Individualproductsmaybeexcludedfromthisguarantee.Checkproductdescriptionbefore youplaceorders.
• Wecan’ttakeresponsibilityforanymissingordamagedparcels-takecarewhenreturning orderstous.
Ifreturnisduetoaproductdefect,call+44 (0) 151 318 6163toinitiatereturn.
REFUNDS ON ITEMS PURCHASED THROUGH CLEVERCOMPANY.COM
Onceitemsarereceivedbyourwarehouse,theywillbeprocessedandarefundinitiated.Youraccountshouldbecreditedwithinamaximumof10businessdaysfromthetimeitemsarereceived.
DEFECTIVE ITEMS
Ifyouritemisdefectiveinanyway,consultourFAQsectionatclevercompany.comastheremaybeasimplesolutiontotheissue.Ifthisdoesnotresolvetheissue,pleasecallon+44 (0) 151 318 6163oremail:[email protected].
DAMAGED ITEMS
Purchased from a UK Retailer:Ifyoureceiveanorderfromtheretailerwithobviousshippingdamage-refusedelivery.Ifdeliveryhasbeenacceptedandthenshippingdamageisfound,followspecificinstructionsadvisedbytheretailer.
Purchased from clevercompany.com:Ifyoureceiveanorderwithobviousshippingdamage-refusedelivery.Ifyouhaveaccepteddeliveryandthenfindshippingdamage,pleasecallCleverCompanyusingcontactinformationincludedwithorder.
Savepackagingandpaperworkfortheorder.Ifyoudisposeofpackagingorattempttoreturnproductwithoutcontactingthesupplier,youmaydamageyourchancesofmakingaclaim.
LIMITS OF RESPONSIBILITY
CleverCompanyLimitedacceptnoresponsibilityformisuseoruserdamageand/orlossofpartsincurredduringoperationoruseoftheCleverSpa®.
BLACK LABEL CLEVERSPA UNIVERSAL IM_VERSION 1.indd 14 18/10/2019 15:02
15
WARRANTY
WarrantyrelatestoallCleverSpa®hottubsboughtinUKandcoversthefollowingareas:
• CleverSpa® Pump Heater: 12 months from date of purchase• CleverSpa® Cover & Liner: 6 months from date of purchase
Warranty is not transferable if the goods are resold after original purchase.
CleverSpa®isdesignedandmanufacturedfordomesticuseonly.TheWarrantydoesnotextendtoanycommercialbusinessesuse.
FREE EXTENDED WARRANTY
Ifyouregisterwithin28dayswewillextendyourwarrantyto:
• CleverSpa® Pump Heater: 18 months from date of purchase• CleverSpa® Cover & Liner: 9 months from date of purchase
REGISTERING YOUR WARRANTY
Visitclevercompany.com/support/warranty/ andcompletetheformwithin28daysofpurchase.Warrantywillstartfromdateofpurchasewhichmustbeverifiedbyproofofpurchase.
Forup-to-datetroubleshootingadvice,technicalinformationandFAQsvisitclevercompany.com.
WARRANTY CLAIMS
Beforemakingaclaim,wemaybeabletoansweryourquery,simplyvisitclevercompany.com/support/cleverspa-faqs.
IfFAQsdon’tsolvetheissueandyouneedtomakeaclaim,visitourwebsiteunderwarrantysection,orcontactAftersalesTeambyemailat:[email protected]
If you need to make immediate contact our Aftersales Team are available on +44 (0) 151 318 6163.
Monday – Thursday: 9.00amto5.00pm
Friday: 9.00amto4.00pm
BLACK LABEL CLEVERSPA UNIVERSAL IM_VERSION 1.indd 15 18/10/2019 15:02
IMPORTANT! Before using your CleverSpa®, please treat the water in accordance
with the chemical maintenance on: clevercompany.com
Clever Company Ltd.
UK Address: Oldgate, St.Michael’s Industrial Estate, Widnes, Cheshire, WA8 8TL.
European Address: Radarweg 29, 1043 NX Amsterdam, Netherlands.
Version: 01
General Enquiries, Returns, Spare Parts, Repairs & Chemical Advice
+44 (0) 151 318 6163 or visit: clevercompany.com
Read all chemical instructions carefully and use as directed by
the manufacturer. To purchase CleverSpa® Chemicals and for more advice on CleverSpa® maintenance, visit clevercompany.com
STABILISED CHLORINE GRANULES (500G) For Disinfecting Hot Tub Water
pH PLUS (500G) For Increasing pH Hot Tub Water
pH MINUS (500G) For Decreasing pH Hot Tub Water
FOAM REMOVER (500ML) Prevents & Removes Hot Tub Foam
DIP TEST (x25) For testing Chlorine, pH and total Alkalinity
Ensure your CleverSpa® is always working at its best, we recommend
our CleverSpa® Chemical Spa Starter kit:
BLACK LABEL CLEVERSPA UNIVERSAL IM_VERSION 1.indd 16 18/10/2019 15:02