IS-C1032R3 1 OF 5 1 2 Installation Instructions 3.5” MX Pendant - Surface Mounted IMPORTANT SAFETY INSTRUCTIONS Read all installation instructions before installing. It is important to save these instructions. Only install and connect LED module with power disconnected at the circuit breaker. Hot plugging, or connecting the module with power on, could damage the LEDs and is not covered by warranty. Observe and follow all label information and instructions regarding dry, damp and wet location listings, proper Intense LED module, warnings of installation near combustible materials and/or insulation. Be sure to connect ground wire to prevent electric shock or other potential hazards. The product must be installed in a manner consistent with the intended use and in compliance with the national electrical codes and local codes by a person familiar with the construction and operation of the product and the hazards involved. WARNING: Use only Intense Lighting trims listed for use with this fixture. Use of trims other than those listed by Intense Lighting is a violation of N.E.C 110-3(B) and voids all warranties. WARNING Risk of electrical shock. Disconnect power before servicing or installing luminaire. ! WARNING Risk of injury or damage. Luminaire will fail if not installed properly. Follow installation instructions. ! WARNING Risk of injury. Wear safety glasses and gloves during installation and servicing. Allow ample time to cool before handling. ! ATTACH MOUNTING BRACKET TO JUNCTION BOX: 1. Attach mounting bracket to 4 inch junction box with mud cover riser by two 8-32 fasteners (supplied by others) 2. Make sure connecting wires come through center clearance area on bracket for wire connections Mounting Bracket 8-32 Fasteners SURFACE FIXTURE INSTALLATION 1. Temporarily secure fixture close enough to mounting bracket for wiring 2. Make electrical connections 3. Connect ground wire from universal mounting bracket to green (ground) supply wire and ground wire from fixture, white wire from cylinder to white (neutral) supply wire and black wire from cylinder to black (hot) supply wire. Use UL listed connectors or wire nuts (by others) to make the connections. Connect dimming wires if applicable, see pages 4-5 3 SURFACE FIXTURE INSTALLATION (CONT.) 1. Push excess wires through center clearance area of mounting bracket 2. Lift fixture against mounting bracket at keyed slots and once sprung back engaged fixture with clockwise turn 3. Make sure gap between ceiling and fixture is even to ensure fixture is fully installed 4. (FOR WET LOCATION APPLICATIONS ONLY) Apply silicone all around between ceiling and fixture to ensure fixture is sealed. Center Clearance Area of Mounting Bracket INSTRUCTIONS L/M-01062020 P-1 INSTRUCTIONS L/M-01062020 P-1 INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883 For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321. © 2020 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Upload: others

Post on 18-Mar-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INSTRUCTIONS - Intense LightingIS-C1032R3 1 OF 5 1 2 Installation Instructions 3.5” MX Pendant - Surface Mounted IMPORTANT SAFETY INSTRUCTIONS – Read all installation instructions

IS-C1032R31 OF 5

1 2

Installation Instructions3.5” MX Pendant - Surface Mounted

IMPORTANT SAFETY INSTRUCTIONS – Read all installation instructions before installing. It is important to save these instructions. – Only install and connect LED module with power disconnected at the circuit breaker. Hot plugging, or connecting the module with power

on, could damage the LEDs and is not covered by warranty. – Observe and follow all label information and instructions regarding dry, damp and wet location listings, proper Intense LED module,

warnings of installation near combustible materials and/or insulation. – Be sure to connect ground wire to prevent electric shock or other potential hazards. – The product must be installed in a manner consistent with the intended use and in compliance with the national electrical codes and local

codes by a person familiar with the construction and operation of the product and the hazards involved. – WARNING: Use only Intense Lighting trims listed for use with this fixture. Use of trims other than those listed by Intense Lighting is a

violation of N.E.C 110-3(B) and voids all warranties.

WARNING

Risk of electrical shock. Disconnect power before servicing or installing luminaire.

!

WARNING

Risk of injury or damage. Luminaire will fail if not installed properly. Follow

installation instructions.

!

WARNING

Risk of injury. Wear safety glasses and gloves during installation and servicing.

Allow ample time to cool before handling.

!

ATTACH MOUNTING BRACKET TO JUNCTION BOX:1. Attach mounting bracket to 4 inch junction box with mud cover riser by two 8-32

fasteners (supplied by others)2. Make sure connecting wires come through center clearance area on bracket for wire

connections

Mounting Bracket

8-32 Fasteners

SURFACE FIXTURE INSTALLATION1. Temporarily secure fixture close

enough to mounting bracket for wiring

2. Make electrical connections3. Connect ground wire from universal

mounting bracket to green (ground) supply wire and ground wire from fixture, white wire from cylinder to white (neutral) supply wire and black wire from cylinder to black (hot) supply wire. Use UL listed connectors or wire nuts (by others) to make the connections. Connect dimming wires if applicable, see pages 4-5

3SURFACE FIXTURE INSTALLATION (CONT.)1. Push excess wires through center

clearance area of mounting bracket2. Lift fixture against mounting bracket at

keyed slots and once sprung back engaged fixture with clockwise turn

3. Make sure gap between ceiling and fixture is even to ensure fixture is fully installed

4. (FOR WET LOCATION APPLICATIONS ONLY) Apply silicone all around between ceiling and fixture to ensure fixture is sealed.

Center Clearance Area of Mounting Bracket

INSTRUCTIONS L/M-01062020 P-1 INSTRUCTIONS L/M-01062020 P-1

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2020 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Page 2: INSTRUCTIONS - Intense LightingIS-C1032R3 1 OF 5 1 2 Installation Instructions 3.5” MX Pendant - Surface Mounted IMPORTANT SAFETY INSTRUCTIONS – Read all installation instructions

Installation Instructions3.5” MX Pendant - Remote Driver & Accessories

IS-C1032R32 OF 5

Release Cap

Accessories

Accessory Holder

Accessory Holder’s Retaining Clip

Module

ACCESSORY HOLDER:1. Rotate release cap by turning counter clockwise.2. Install accessories into accessory holder and replace accessory holder’s retaining clip.3. Place accessory holder and accessory flush against optic and replace release cap.

OPTIC REPLACEMENT:1. Remove trim, then remove module from channel and disconnect quick connect.2. Rotate release cap by turning counter clockwise.3. Set cap and retainer ring aside and change optics.4. Align optic pins to slots in module.

Release Cap

Retainer Ring

Optic

ModuleOptic Slots

1 2

Remote Driver Housing Installation

Accessory & Optics Installation

REMOTE BOX INSTALLATION1. Remove two 8-32 fasteners and save to reinstall cover plate2. Remove cover plate3. Remove required knockouts and run conduit to junction box fixture is attached to

(**maximum 50 feet length from fixture”)

Remote Box

Cover Plate

Two 8-32 Fasteners Supllied With Housing

REMOTE BOX INSTALLATION1. Run connecting wires for LED driver class 2 by local and national electrical regulations,

minumun 18 awg wire and at maximum 50 feet length2. Attach remote box at two 1/4” holes on 6 inch centers with frame in installation

hardware (supplied by others)3. Make electrical connections (See Page 2, Step 2)4. Reinstall cover plate with supplied 8-32 hardware, insure wires are clear of box edges

not pinched or damaged when cover is screwed down

NOTE: ***NOT RATED FOR THROUGH WIRING***

Suppliesby others

Ground Fastener

LED Driver Cover Supplies

by others

Frame In Installation Hardware (Supplied By Others)Two Ø1/4” Holes On 6 Inch Center

INSTRUCTIONS L/M-01062020 P-2

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2020 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Page 3: INSTRUCTIONS - Intense LightingIS-C1032R3 1 OF 5 1 2 Installation Instructions 3.5” MX Pendant - Surface Mounted IMPORTANT SAFETY INSTRUCTIONS – Read all installation instructions

IS-C1032R33 OF 5

Installation Instructions3.5” MX Pendant - Surface Mounted

1

2b

Fixture Maintenance

MAINTENANCE STEP (DRIVER ACCESS)1. Remove four M3 x 10mm flat head fasteners

DRIVER REPLACEMENT: DRIVER TYPE 2:

Driver Plate

M3 Nut

M3 x 10mmFlat Head

M3 Pan Head

Small, Side Feed Driver

2aDRIVER REPLACEMENT: DRIVER TYPE 1:

M3 x 10mmFlat Head

8-32 Nut

Driver Plate

Bottom Feed Driver

M3 X 10mm Flat Head

INSTRUCTIONS L/M-01062020 P-3

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2020 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

INSTRUCTIONS L/M-01062020 P-3

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2020 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Page 4: INSTRUCTIONS - Intense LightingIS-C1032R3 1 OF 5 1 2 Installation Instructions 3.5” MX Pendant - Surface Mounted IMPORTANT SAFETY INSTRUCTIONS – Read all installation instructions

IS-C1032R34 OF 5

Installation Instructions3.5” MX Pendant - Dimming Compatibility

DMX512 RDM DIMMING ■ 120V or 277V ■ Dims down to 0.1% light output ■ RDM channel programmable

LED LIGHT ENGINE

DMX512 IN

120 OR 277V INPUT

DRIVER

ORANGE (DMX -)

BROWN (DMX GROUND)

ORANGE/WHITE (DMX +)

BLACK

WHITE

GREENBLACK - NEGATIVE

RED - POSITIVE

FORWARD / REVERSE PHASE DIMMING ■ 120V only ■ See chart below for minimum dimming levels ■ Consult dimming manufacturer for installation instructions

DRIVER120V INPUT

FROM DIMMER

BLACK - NEGATIVE

LED LIGHT ENGINE

RED - POSITIVEBLACK

WHITE

GREEN

COMPATIBLE DIMMERS MX MODULE DIMS DOWN TOProduct Part Number(s) Type L0 L1 L2 L3Leviton IPE04 Reverse 8% 6% 8% 8%Leviton IPI06-1LZ Forward - 1% 1% 1%Leviton 6633-P Forward 1% 1% 1% -Lutron DVELV300P Reverse 8% 6% 9% 9%Lutron DVCL-153P Forward 1% 1% 1% 1%Lutron S600P Forward 3% 1% 2% 2%Cooper DLC03P Forward - 1% 1% 2%Cooper DAL06P Forward - 1% 1% 1%

DRIVERINPUT

GREY (-)

0-10V DIMMER

BLACK - NEGATIVE

LED LIGHT ENGINE

RED - POSITIVE

VIOLET (+)

BLACK

WHITE

GREEN

0-10V DIMMING ■ 120V/277V ■ Dims down to 1% or 0.1% light output ■ Consult dimming manufacturer for installation instructions and power packs

COMPATIBLE DIMMERSManufacturer Part Number(s)HUNT PS-010-IV-120V, PS-010-WH-120V, PS-010-3W-IV-120, PS-010-3W-WH-120V, PS-010-IV-277V, PS-010-WH-277V, PS-010-3W-IV-277V, PS-010-3W-WH-277V, FD-010: PS-IFC-010-IV, PS-IFC-010-WH-120/277V, FD-010: PS-IFC-010-3W-IV, PS-IFC-010-3W-WH-120/277V, FD-010-120V, FD-010-277VLeviton Leviton Centura Fluorescent Control System, IllumaTech™ IP7 Series, DPSPE-212Lightolier ZP600FAM120, MP1500FAM120, V2000FAMULithonia LEQ BC, LEQ LVBC, SLD LVBC, SQ1DCLutron DVTV, NTFTVSynergy ISD BC 120/277

INSTRUCTIONS L/M-01062020 P-4

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2020 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

INSTRUCTIONS L/M-01062020 P-4

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2020 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

Page 5: INSTRUCTIONS - Intense LightingIS-C1032R3 1 OF 5 1 2 Installation Instructions 3.5” MX Pendant - Surface Mounted IMPORTANT SAFETY INSTRUCTIONS – Read all installation instructions

IS-C1032R35 OF 5

Installation Instructions3.5” MX Pendant - Dimming Compatibility

LUTRON ECOSYSTEM® DIMMING - 120V or 277V - Dims down to 1% - Consult dimming manufacturer for installation instructions

COMPATIBLE DIMMERSProduct Part Number(s)EcoSystem CS-1L-WM, CS-2L-WM, CS-1L-CM, CS-2L-CM, EcoSystem ESN, Grafik Eye QS with EcoSystem, Quantum

DRIVER

ECO SYSTEM CONTROL

(BY OTHERS)

ECO SYS BUS

BLACK - NEGATIVE

LED LIGHT ENGINE

RED - POSITIVE

VIOLET (E1)

VIOLET (E2)

BLACK

WHITE

GREEN

DRIVER

3-WIRE CONTROL

(BY OTHERS)BLACK - NEGATIVE

LED LIGHT ENGINE

RED - POSITIVEBLACK

WHITE

GREENORANGE

LUTRON HI-LUME® DIMMING - 120V or 277V - Dims down to 1% - Consult dimming manufacturer for installation instructions

COMPATIBLE DIMMERSAYF-103P, AYF-103P-277, DVF-103, DVF-103P-277, DVSCF-103P, DVSCF-103P-277, HQRD-F6AN-DV, LXF-103PL, LXF-103PL-277, NF-10, NF-103P, NF-103P-277, NF-10-277, NTF-10, NTF-103P, NTF-103P-277, NTF-10-277, RRD-F6AN-DV, SF-12P-277-3, SF-103P, MAF-6AM, MAF-6AM-277, MSCF-6AM, MCSF-6AM-277, MRF2-F6AN-DV, SF-10P, SF-12P-277, SPSF-6A, SPSF-6A-277, SPSF-6AM, SPSF-6AM-277, VF-10, VTF-6AM

INSTRUCTIONS L/M-01062020 P-5

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2020 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.

INSTRUCTIONS L/M-01062020 P-5

INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2020 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.