BEEN LOOKING FOR THAT ADVANCED SERVER POWER MONITORING SYSTEM? Now you can get it in your current system, in a new system, and in PDI’s comprehensive WaveStar® system. PDI’s JComm® Branch Monitoring System is now available to monitor and integrate all your server power functions. No matter whose equipment you have. Of course, we believe our PDUs and RPPs are the best, but if you’d rather not spec power strips at a higher cost, PDI’s JComm® BCMS brings it all together. PDI can now offer four different ways to retrofit into your existing data center. PDI’s JComm® BCMS: Avoids overloads Provides realtime data for managing server loads Keeps watch of system performance of PDUs and RPPs BCMS Split Core works with energized systems BCMS Solid Core is used on PDI equipment or can be ordered as OEM-added equipment A complete WaveStar® STS-PDU-RPP system can effectively bring all of PDI’s advantages together and look at all downstream BCMS devices JCOMM ® BCMS FROM PDI INTEGRATED BRANCH CIRCUIT MONITORING SYSTEM MADE FOR EVERYONE For More Information Use your QR Reader jcomm ® rpp with jcomm ® wavestar ® rpp jcomm ® jcomm ® wavestar ® pdu pdu with jcomm ® pdi bcms hub 1 4 2 3 WHERE CAN YOU ADD JCOMM ® BCMS? UNDER FLOOR EXISTING RPP EXISTING PDU ON A WALL 1 2 3 4

Upload: others

Post on 13-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INTEGRATED BRANCH CIRCUIT MONITORING SYSTEM MADE …criticaleg.com/wp-content/uploads/2017/06/PDI-Branch-Circuit... · • A complete WaveStar® STS-PDU-RPP system can effectively

BEEN LOOKING FOR THAT ADVANCED SERVER POWER MONITORING SYSTEM? Now you can get it in your current system, in a new system, and in PDI’s comprehensive

WaveStar® system.

PDI’s JComm® Branch Monitoring System is now available to monitor and integrate all your

server power functions. No matter whose equipment you have. Of course, we believe our

PDUs and RPPs are the best, but if you’d rather not spec power strips at a higher cost, PDI’s

JComm® BCMS brings it all together.

PDI can now offer four different ways to retrofit into your existing data center. PDI’s

JComm® BCMS:

• Avoids overloads

• Provides realtime data for managing server loads

• Keeps watch of system performance of PDUs and RPPs

• BCMS Split Core works with energized systems

• BCMS Solid Core is used on PDI equipment or can be ordered as OEM-added equipment

• A complete WaveStar® STS-PDU-RPP system can effectively bring all of PDI’s advantages

together and look at all downstream BCMS devices

JCOMM® BCMS FROM PDI

INTEGRATED BRANCH CIRCUIT MONITORING SYSTEM MADE FOR EVERYONE

For M

ore

Info

rmat

ion

Use

your

QR

Read

er

jcomm ® rpp w ith jcomm ®

wave star ® rpp

jcomm ®

jcomm ®

wave star ® pdu

pdu w ith jcomm ®

pd ibcmshub

1

4 23WHERE CAN YOU ADD JCOMM® BCMS?

UNDER FLOOR

EXISTING RPP

EXISTING PDU

ON A WALL

1

2

3

4

Page 2: INTEGRATED BRANCH CIRCUIT MONITORING SYSTEM MADE …criticaleg.com/wp-content/uploads/2017/06/PDI-Branch-Circuit... · • A complete WaveStar® STS-PDU-RPP system can effectively

BEYOND THE JCOMM TM BCMS SYSTEM

Power Distribution, Inc. | 4200 Oakleys Court | Richmond, VA 23223

800.225.4838 | 804.737.1703 fax | web site: www.pdicorp.com

©PDI 06/12

Or our integrated WaveStar® STS hub containing the best in a switch, PDU and RPP technology and a completely online monitoring system.

• GraphicdisplayofallBCMScards.

• CanbeusedasahubforotherBCMSdevices.

• Easyscrollingandinformationcapturewithlargescreendisplay.

• Snapshotofpanelboards,showsloads,loadtrending,andmore.

• ReportonandmanageyourserverloadslocallythroughBCMS.

• Install as factory-installed device or add to existing units in the field.

• Can be retrofitted into any manufacturer’s equipment.

you can also gain control of your system locally with PDI’s WaveStar® Monitor:

WaveStar ® pdupdu w ith jcomm ®

WaveStar ® s w itch

WaveStar ® r pprpp w ith jcomm ®

WaveStar ® r ppWaveStar ® r pp

jcomm ®

jcomm ®

jcomm ®

pd ibcms

hub

WaveStar® Graphics Monitor

•WaveStar® BCMS monitor

• OnescreengathersinfofromRPPs,PDUsandswitches

• IntegratesalldownstreamBCMSdevicesintoonehub

• MinimizedBuildingManagementSystemaddresses

• AccessvialocalmonitororremotelythroughSNMP,

Modbus®, or modem