Intelligent Transformer AVR
EDM
※ Application:
Feature:
Big range high/low voltage protect device
Start over voltage protection
Humanized anti-mistake circuit design
Intelligent logic voltage regulation design
Innovative panel design
Electronic double-circuit On/Off design
Double over-current protection design
Separated voltage regulation design
Self-detecting function
Instant tripping protection device
Module design
Phase loss protection
Dip-switch protection setting Short circuit protection
Grinding Machine WEDM Integrated ProcessingMachine
Milling Machine AI ComponentInserting Machine
Specially for transformer & voltage regulation equipment
PS-B series
Specialized design of voltage regulator and voltage transformation, changing from 3 phase 380V to 3 phase 220V at capacity between 12 and 15 KVA. The equipment is most suitable for matching with precision machine for export. Control and mechanism of PS series Intelligent model has the function of voltage transformation, voltage regulation, warning and protection.
Double OverloadProtection Device Top Grade NFBMulti-Function Main
Control PCB
Including 3 phasetime-series inching,self detection, multiplelayer big range settingand high / low voltageprotection.
In addition to NFB,there is devicepreventing outputoverload andincorporated withbypass protectionfunction
Incorporated with topgrade NF type High-Voltage resistance No-Fuse Breaker withprecise overloadtripping function
Specific LampIndicator, Include
Fools Proof
Solid Input/ OutputProtection
Output and input wiresare wired from middleand up to left and rightand fixed with cablefastener to form firmwiring.
Individual indicator for each of 3 phase andhigh / low voltage andnormal indicators,including fools proofdouble circuit switchforming a mosthumanized design
Model & Specification:
Model No. (PS-B)
Capacity
Input Voltage
Input Range
Output Voltage
Output Accuracy
Waveform Distortion
Frequency
Response Time
Dimension WxHxD (cm)
Environment
312NY 315NY 315YNY
12KVA
312YNY
12KVA15KVA 15KVA
Phase FailureProtection
Indicators
Overload
Bypass
Short Circuit
High Voltage
Low Voltage
Power
Voltage
Abnormal
3ψ4W 220/380V
3ψ4W 127/220V
3ψ3W 380V
3ψ3W 220V
±15%
≦1%
50/60Hz±5%
<0.1 second
No distortion
0.95~1
≧98%
150% for 10 seconds
Standard Feature (input and output double protection)
Standard Feature
Standard Feature
Standard Feature
Standard Feature
Standard Feature (can be Various / Multi / Big range pre-set and LED displayed)
Standard Feature (can be Various / Multi / Big range pre-set and LED displayed)
Standard Feature (can be Various / Multi / Big range pre-set and LED displayed)
Standard Feature
Temperature: 0℃~45℃ Humidity: 0%~95% RH (Non-Condensing)
36x63x58
Power Factor
Efficiency
Overload