intended use - pennsylvania state university · 0 909090 888888 848484 1 848178 827977 767473 2...

6
Example: 2PM3N G B 3 32 18LD 120 GEB Series 2PM3N Paramax 3" deep cell parabolic, 2' wide Air function A Air supply/return (slots in side trim) H Heat removal (through lamp cavity, dampers available) B No air function D Dual function supply/return/ removal ORDERING INFORMATION Voltage 120, 277, 347, MVOLT 2 Others available. 2PM3N Options 1/3 One 3-lamp ballast 1/4 One 4-lamp ballast GEB Electronic ballast, <20% THD GEB10IS Electronic ballast, <10% THD, Instant Start GEB10RS Electronic ballast, <10% THD, Rapid Start EL Emergency battery pack (nominal 300 lumens; see Fluorescent Battery Packs tab) LST Tandem fixture pairs (shared ballasts) PWS1836 6' prewire, 3/8" dia., 18-gauge, 3 wires GLR Internal fast-blow fuse GMF Internal slow-blow fuse LP__ Lamped; specify lamp type and color CRE Flanged trim for continuous row mounting (end) CRM Flanged trim for continuous row mounting (middle) ACS Air closure strips (A and D models only) HRD Heat-removal dampers APB Air-pattern control blades (A and D models only) 3 PAF Painted after fabrication (white enamel) 3 2R Two reflector channel covers 4 JP Palletized and stretch-wrapped (G and MT trim only) CSA CSA Certified NOM NOM Certified Lamp type 32 32W T8 (48") 40 40W T12 (48") Number of lamps 2, 3, 4 Not included. Louver finish LD Low iridescent anodized diffuse silver ND Achroma TM non-iridescent diffuse silver LS Low iridescent anodized specular silver 3 C Diffuse gold anodized (champagne) 3 W White enamel 3 Number of cells 1 12 , 16 , 18 , 24, 32 Trim type G Grid F Overlapping flange MT Modular fit-in ST Screw slot NOTES: 1 Typical cell configuration determined by lamp quantity unless specified otherwise. 2 MVOLT available with GEB10IS only. 3 Consult factory for housing depth. 4 Available with 3-lamp 18 or 24 cell only. FEATURES & SPECIFICATIONS INTENDED USE High performance deep-cell parabolic luminaires for superior light control, visual comfort and light cutoff in open area applications. ATTRIBUTES Designed for optimal performance with T8 lamps and electronic ballasts. Choice of low iridescent diffuse or specular louver finishes. Also available with Achroma TM non-iridescent louver finish. CONSTRUCTION Black reveal provides floating louver appearance, conceals optional air- supply slots. Integral T-bar safety clips hold T-bar securely; no fasteners required to install. Overlapping flange and modular ceiling trims factory-installed with stan- dard swing-gate hangers or field convertible with optional trim and hang- ers. T-hinges die-formed for maximum strength. Latches spring-loaded, concealed in reveal. Optional heat-removal dampers and air closure strips to control airflow. Housing formed from cold-rolled steel. Louvers formed from anodized alu- minum. No asbestos is used in this product. FINISH Five-stage iron-phosphate pretreatment ensures superior paint adhesion and rust resistance. Painted parts finished with high-gloss, baked white enamel. ELECTRICAL SYSTEM Thermally-protected, resetting, Class P, HPF, non-PCB, UL Listed, CSA certi- fied ballast is standard. Energy saving and electronic ballasts are sound rated A. Luminaire is suitable for damp locations. AWM, TFN or THHN wire used throughout, rated for required temperatures. LISTING UL Listed (standard). CSA Certified or NOM Certified (see Options). WARRANTY Guaranteed for one year against mechanical defects in manufacture. Specifications subject to change without notice. Catalog Number Notes Type PARAMAX PARAMAX PARAMAX PARAMAX PARAMAX ® Parabolic Troffer Parabolic Troffer Parabolic Troffer Parabolic Troffer Parabolic Troffer 2PM3N 2'x4' 3" Deep Louver Specifications Length: 24 (609) Width: 48 (1218) Depth: 5-1/4 (133) Weight: 35 lbs (15.9 kg) All dimensions are inches (millimeters). 24 (609) 5-1/4 (133) 48 (1218) PAR-130 Sheet #: PM3N-2x4 Fluorescent

Upload: others

Post on 27-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INTENDED USE - Pennsylvania State University · 0 909090 888888 848484 1 848178 827977 767473 2 777268 767167 686562 3 716560 706459 615754 4 665852 645752 555147 5 615246 595146

Example: 2PM3N G B 3 32 18LD 120 GEB

Series

2PM3N Paramax3" deepcellparabolic,2' wide

Air function

A Air supply/return(slots in side trim)

H Heat removal(through lampcavity, dampersavailable)

B No air functionD Dual function

supply/return/removal

ORDERING INFORMATION

Voltage

120, 277, 347,MVOLT2

Othersavailable.

2PM3N

Options

1/3 One 3-lamp ballast1/4 One 4-lamp ballast

GEB Electronic ballast, <20% THDGEB10IS Electronic ballast, <10% THD, Instant Start

GEB10RS Electronic ballast, <10% THD, Rapid StartEL Emergency battery pack (nominal 300 lumens; see

Fluorescent Battery Packs tab)LST Tandem fixture pairs (shared ballasts)

PWS1836 6' prewire, 3/8" dia., 18-gauge, 3 wiresGLR Internal fast-blow fuse

GMF Internal slow-blow fuseLP__ Lamped; specify lamp type and color

CRE Flanged trim for continuous row mounting (end)CRM Flanged trim for continuous row mounting (middle)ACS Air closure strips (A and D models only)HRD Heat-removal dampersAPB Air-pattern control blades (A and D models only)3

PAF Painted after fabrication (white enamel)3

2R Two reflector channel covers4

JP Palletized and stretch-wrapped (G and MT trim only)CSA CSA Certified

NOM NOM Certified

Lamp type

32 32W T8 (48")40 40W T12 (48")

Numberof lamps

2, 3, 4Not included.

Louver finish

LD Low iridescentanodizeddiffuse silver

ND AchromaTM

non-iridescentdiffuse silver

LS Low iridescentanodizedspecular silver3

C Diffuse goldanodized(champagne)3

W White enamel3

Numberof cells 1

12 , 16 , 18 ,24, 32

Trim type

G GridF Overlapping

flangeMT Modular fit-inST Screw slot

NOTES:1 Typical cell configuration determined

by lamp quantity unless specifiedotherwise.

2 MVOLT available with GEB10IS only.3 Consult factory for housing depth.4 Available with 3-lamp 18 or 24 cell

only.

FEATURES & SPECIFICATIONSINTENDED USE

High performance deep-cell parabolic luminaires for superior light control,visual comfort and light cutoff in open area applications.ATTRIBUTESDesigned for optimal performance with T8 lamps and electronic ballasts.Choice of low iridescent diffuse or specular louver finishes. Also available withAchromaTM non-iridescent louver finish.CONSTRUCTION

Black reveal provides floating louver appearance, conceals optional air-supply slots.Integral T-bar safety clips hold T-bar securely; no fasteners required toinstall.Overlapping flange and modular ceiling trims factory-installed with stan-dard swing-gate hangers or field convertible with optional trim and hang-ers. T-hinges die-formed for maximum strength. Latches spring-loaded,concealed in reveal.Optional heat-removal dampers and air closure strips to control airflow.Housing formed from cold-rolled steel. Louvers formed from anodized alu-minum. No asbestos is used in this product.FINISH

Five-stage iron-phosphate pretreatment ensures superior paint adhesionand rust resistance. Painted parts finished with high-gloss, baked whiteenamel.ELECTRICAL SYSTEM

Thermally-protected, resetting, Class P, HPF, non-PCB, UL Listed, CSA certi-fied ballast is standard. Energy saving and electronic ballasts are soundrated A.Luminaire is suitable for damp locations. AWM, TFN or THHN wire usedthroughout, rated for required temperatures.LISTING

UL Listed (standard). CSA Certified or NOM Certified (see Options).WARRANTY

Guaranteed for one year against mechanical defects in manufacture.Specifications subject to change without notice.

Catalog Number

Notes Type

PARAMAXPARAMAXPARAMAXPARAMAXPARAMAX® Parabolic Troffer Parabolic Troffer Parabolic Troffer Parabolic Troffer Parabolic Troffer

2PM3N 2'x4'

3" Deep Louver

Specifications

Length: 24 (609)Width: 48 (1218)Depth: 5-1/4 (133)Weight: 35 lbs (15.9 kg)

All dimensions are inches (millimeters).

24(609)

5-1/4 (133)

48(1218)

PAR-130Sheet #: PM3N-2x4Fluorescent

Page 2: INTENDED USE - Pennsylvania State University · 0 909090 888888 848484 1 848178 827977 767473 2 777268 767167 686562 3 716560 706459 615754 4 665852 645752 555147 5 615246 595146

DIMENSIONS

PHOTOMETRICSCalculated using the zonal cavity method in accordance with IESNA LM41procedures. Floor reflectances are 20%. Lamp configurations shown are typical.Full photometric data on these and other configurations available upon request.

NOTE:1 Recommended rough-in dimensions for F trim fixtures 24"x48"

(Tolerance is +1/4", -O”). Swing-gate range 1-7/16" to 3-7/16", span23-1/2" to 26-7/16".

2PM3N 3 32 18LDReport LTL 6347 – Lumens per lamp = 2900S/MH (along) 1.3 (across) 1.6Coefficient of UtilizationCeiling 80% 70% 50%Wall 70% 50% 30% 70% 50% 30% 50% 30% 10%

0 90 90 90 88 88 88 84 84 841 84 81 78 82 79 77 76 74 732 77 72 68 76 71 67 68 65 623 71 65 60 70 64 59 61 57 544 66 58 52 64 57 52 55 51 475 61 52 46 59 51 46 50 45 416 56 47 41 55 47 41 45 40 367 52 43 37 51 42 37 41 36 328 49 39 33 48 39 33 38 33 299 46 36 30 45 36 30 35 30 26

10 43 33 28 42 33 27 32 27 24

Zonal Lumens SummaryZone Lumens %Lamp %Fixture

0-30 2132 24.5 32.50-40 3711 42.7 56.60-60 6142 70.6 93.70-90 6552 75.3 100.0

90-180 0 0 00-180 6552 75.3 100.0

MOUNTING DATA

AppropriateCeiling Type Trim Type

Exposed grid tee GConcealed grid tee G, STConcealed Z-spline F, MTMetal pan (consult factory) MTScrew slot (consult factory) STAcoustical tile, plaster or plasterboard Fon rigid support parallel to lamps

Continuous row mounting of flanged units requires CRE and CRM trimoptions (see options).

2PM3N 2'x4' 3" Louver Family

2PM3N 2 32 12LDReport LTL 6369 – Lumens per lamp = 2900S/MH (along) 1.3 (across) 1.5Coefficient of UtilizationCeiling 80% 70% 50%Wall 70% 50% 30% 70% 50% 30% 50% 30% 10%

0 91 91 91 89 89 89 85 85 851 85 82 79 83 80 77 77 75 732 78 72 68 76 71 67 68 65 623 71 64 58 69 63 58 61 56 534 65 57 51 64 56 50 54 49 455 60 51 44 59 50 44 48 43 396 55 46 39 54 45 39 44 38 347 51 41 35 50 41 35 40 34 308 48 38 31 46 37 31 36 31 279 44 34 28 43 34 28 33 28 24

10 41 32 26 41 31 25 30 25 22

Zonal Lumens SummaryZone Lumens %Lamp %Fixture

0-30 1256 21.7 28.40-40 2133 36.8 48.20-60 4074 70.3 92.00-90 4428 76.3 100.0

90-180 0 0 00-180 4428 76.3 100.0

2PM3N 4 32 32LDReport LTL 6366 – Lumens per lamp = 2900S/MH (along) 1.2 (across) 1.3Coefficient of UtilizationCeiling 80% 70% 50%Wall 70% 50% 30% 70% 50% 30% 50% 30% 10%

0 80 80 80 78 78 78 74 74 741 75 72 70 73 71 69 68 66 652 69 65 61 68 64 60 61 59 563 64 58 54 63 57 53 55 52 494 59 52 47 58 52 47 50 46 435 55 47 42 54 47 42 45 41 386 51 43 38 50 42 37 41 37 337 47 39 34 46 39 34 38 33 308 44 36 31 43 35 30 35 30 279 41 33 28 40 33 28 32 27 24

10 39 30 25 38 30 25 29 25 22

Zonal Lumens SummaryZone Lumens %Lamp %Fixture

0-30 2791 24.1 35.90-40 4592 39.6 59.10-60 7443 64.2 95.70-90 7775 67.0 100.0

90-180 0 0 00-180 7775 67.0 100.0

Energy (Calculated in accordance with NEMA standard LE-5)

ANNUAL LAMP LAMP BALLASTLER.FP ENERGY COST* DESCRIPTION LUMENS FACTOR WATTS

62 (LD louver) $3.87 (2) 32WT8 2850 .88 6260 (ND louver) $4.00 (2) 32WT8 2850 .88 6266 (LD louver) $3.64 (3) 32WT8 2850 .88 8662 (ND louver) $3.87 (3) 32WT8 2850 .88 8661 (LD louver) $3.96 (4) 32WT8 2850 .88 111* Comparative yearly lighting energy cost per 1000 lumens

* 2-13/16 end blade depth2-11/16 width blade depth

Sheet #: PM3N-2x4

Lithonia LightingAcuity Lighting Group, Inc.FluorescentOne Lithonia Way, Conyers, GA 30012Phone: 800-858-7763 Fax: 770-929-8789In Canada: 1100 50th Ave., Lachine, Quebec H8T 2V3www.lithonia.com©1997 Acuity Lighting Group, Inc., 5/02 Pm3n-2X4.p65

Appendix V-1

Page 3: INTENDED USE - Pennsylvania State University · 0 909090 888888 848484 1 848178 827977 767473 2 777268 767167 686562 3 716560 706459 615754 4 665852 645752 555147 5 615246 595146

Type Catalog number

..................................... ...................................................................................................................

..................................... ...................................................................................................................

Optimax® Parabolic Light Control System

PMO 2'x4'2 Lamps 18 Cells

PMO 2x4 18

FEATURES• Full family of light controlling parabolic luminaires designed to

control screen glare in VDT open office environments.• Meets IES RP-1 minimum luminance criteria for office lighting

systems in VDT applications.• Choice of diffuse or specular louvers utilize the latest develop-

ments in louver finishing for minimized louver iridescence. Idealfor use with triphosphor lamps.

• Black reveal provides floating louver appearance, conceals op-tional air-supply slots.

• Overlapping flange and modular ceiling trims factory-installedwith standard swing-gate hangers or field convertible withoptional trim and hanger kits.

• Optional heat-removal dampers and air-pattern controlblades allow airflow control.

• T-hinges die-formed for maximum strength. Latches spring-loaded, concealed in reveal.

• Guaranteed for one year against mechanical defects inmanufacture.

SPECIFICATIONSBALLAST — Thermally-protected, resetting, Class P, HPF,

non-PCB, UL listed, CSA certified ballast is standard. Energy-saving and electronic ballasts are sound rated A. Standardcombinations are CBM approved and conform to UL 935.

WIRING & ELECTRICAL — Fixture conforms to UL 1570 and issuitable for damp locations. AWM, TFN or THHN wire usedthroughout, rated for required temperatures.

MATERIALS — Housing formed from cold-rolled steel. Louversformed from anodized aluminum. No asbestos is used in thisproduct.

FINISH — Five-stage iron-phosphate pretreatment ensures supe-rior paint adhesion and rust resistance. Painted parts finishedwith high-gloss, baked white enamel.

LISTING — UL listed and labeled. Listed and labeled to complywith Canadian Standards and Mexican Standards (see options).

Specifications subject to change without notice.

PHOTOMETRICSCalculated using the zonal cavity method in accordance with IESNA LM41 procedure. Floor reflectances are 20%.Lamp configurations shown are typical. Full photometric data on these and other configurations available upon request.

2PMO GB 2 32 18LSReport LTL 6028 – Lumens per lamp = 2900S/MH (along) 1.2 S/MH (across) 1.3Coefficient of UtilizationCeiling 80% 70% 50%Wall 70% 50% 30% 70% 50% 30% 50% 30% 10%

0 80 80 80 78 78 78 75 75 751 76 74 72 74 72 71 70 68 672 72 68 65 70 67 64 65 62 603 67 62 59 66 61 58 60 57 544 63 57 53 62 56 53 55 52 495 59 52 48 58 52 47 50 47 446 55 48 43 54 48 43 47 43 407 51 44 39 50 43 39 42 38 358 47 40 35 46 39 35 38 34 319 44 36 31 43 35 31 35 30 27

10 41 33 28 40 32 28 32 27 24

Zonal Lumens SummaryZone Lumens %Lamp %Fixture

0-30 1675 28.9 43.0 0-40 2728 47.0 70.0 0-60 3896 67.2 100.0 0-90 3898 67.2 100.0

90-180 0 0 00-180 3898 67.2 100.0

ENERGY• Luminaire Efficacy Rating (LER) and Annual Energy Cost/1000

Lumens:2-lamp LER.FP (LS louver) = 54. Annual energy cost = $4.44.Based on 32W T8 lamps, 2850 lumen lamp and electronic bal-last with ballast factor = .88 and input watts = 62.

Calculated in accordance with NEMA standard LE-5.

Luminance Summary - cd/m2

Angle 0 45 90

45 1839 3096 358255 76 832 57465 0 0 075 0 0 085 0 0 0

Page 4: INTENDED USE - Pennsylvania State University · 0 909090 888888 848484 1 848178 827977 767473 2 777268 767167 686562 3 716560 706459 615754 4 665852 645752 555147 5 615246 595146

© 1995 Lithonia Lighting, Rev. 5/00PMO 2X4 18.p65

PMO 2'x4' 2 Lamps 18 Cell, Optimax

MOUNTING DATA DIMENSIONS

AppropriateCeiling Type Trim Type

Exposed grid tee GConcealed grid tee G, STConcealed Z-spline F, MTMetal pan (consult factory) MTScrew slot (consult factory) STAcoustical tile, plaster, or plasterboard F

on rigid support parallel to lamps

NOTES:1 Recommended rough-in dimensions for F trim fixtures 24"x48" (Tolerance

is +1/4", -O”). Swing-gate range 1" to 3-1/4", span 23-1/2" to 26-5/16".

Inches (millimeters). Subject to change without notice.

PMO 2X4 18

Example: 2PMO G B 2 32 18LD 120 GEBORDERING INFORMATION

2PMO

Series

2PMO OptimaxLightControlSystem,2' wide

Air function

A Air supply/return (slotsin side trim)

H Heat removal (throughlamp cavity, dampersavailable)

D Combination A & HB Static (no air function,

matching appearance)

Lamp type

32 32W T8 (48")40 40W T12 (48")

Louver finish

LD Low iridescentdiffuse silver

LS Low iridescentspecular silver

Trim type

G GridF Overlapping

flangedMT Modular fit-inST Screw slot

Numberof lamps

2Not included.

Numberof cells

18 2 rows of 9

Options

GEB Electronic ballast, <20% THDGEB10IS Electronic ballast, <10% THD, Instant Start

GEB10RS Electronic ballast, <10% THD, Rapid StartEL Emergency battery pack (nominal 300 lumens)

PWS1836 6' prewire, 3/8" dia., 18-gauge, 3 wiresLST Tandem fixture pairs (shared ballasts)GLR Internal fast-blow fuse

GMF Internal slow-blow fuseLP__ Lamped, specify lamp type and color

CRE Flanged trim for continuous row mounting (end)CRM Flanged trim for continuous row mounting (middle)HRD Heat-removal dampersAPB Air-pattern control blades (A and D models only)PAF Painted after fabrication (white enamel)

JP10 Palletized and stretch-wrapped withoutindividual cartons (10 per), G and MT trim only

CSA Listed and labeled to comply with CanadianStandards

NOM Listed and labeled to comply with MexicanStandards

Voltage

120, 277, 347,MVOLT 1

Othersavailable.

Continuous row mounting of flanged units requires CRE and CRM trim options(see Options).

NOTES:1 MVOLT available with GEB10IS only.

Appendix V-1

Page 5: INTENDED USE - Pennsylvania State University · 0 909090 888888 848484 1 848178 827977 767473 2 777268 767167 686562 3 716560 706459 615754 4 665852 645752 555147 5 615246 595146

Type Catalog number

..................................... ...................................................................................................................

..................................... ...................................................................................................................

..................................... ...................................................................................................................

COMMERCIAL & INDUSTRIAL FLUORESCENT LIGHTING PMO 2x2 3LP 12

Optimax® Parabolic Light Control System

PMO 2'x2'3 Lamps12 Cells

PHOTOMETRICSCalculated using the zonal cavity method in accordance with IESNA LM41 procedures. Floor reflectances are 20%. Lampconfigurations shown are typical. Full photometric data on these and other configurations available upon request.

FEATURES• Full family of light controlling parabolic luminaires designed to

control screen glare in VDT open office environments.• Efficiently delivers appropriate illumination level for paper-based

tasks.• Models available to meet IES RP-1 preferred luminance criteria

for office lighting systems in VDT applications.• Choice of diffuse or specular louvers utilize the latest develop-

ments in louver finishing for minimized louver iridescence. Idealfor use with triphosphor lamps.

• Black reveal provides floating louver appearance, conceals op-tional air supply slots.

• Overlapping flange and modular ceiling trims factory installedwith standard swing-gate hangers or field convertible with op-tional trim and hanger kits.

• Optional heat-removal dampers and air-pattern control bladesallow airflow control.

• T-hinges die-formed for maximum strength. Latches spring-loaded, concealed in reveal.

• Guaranteed for one year against mechanical defects in manufac-ture.

SPECIFICATIONSBALLAST — Thermally protected, resetting, Class P, HPF, non-PCB,

UL listed, CSA certified ballast is standard. Energy-saving andelectronic ballasts are sound rated A. Standard combinations areCBM approved and conform to UL 935.

WIRING & ELECTRICAL — Fixture conforms to UL 1570 and is suit-able for damp locations. AWM, TFN or THHN wire used through-out, rated for required temperatures.

MATERIALS — Housing formed from cold-rolled steel. Louversformed from anodized aluminum. No asbestos is used in this prod-uct.

FINISH — Five-stage iron-phosphate pretreatment ensures supe-rior paint adhesion and rust resistance. Painted parts finishedwith high-gloss, baked white enamel.

LISTING — UL listed and labeled. Listed and labeled to comply withCanadian and Mexican Standards (see options).

Specifications subject to change without notice.

2PMO G B 3 U31 12LSReport LSI 7565S/MH (along) 1.2 (across) 1.5Coefficient of UtilizationCeiling 80% 70% 50%Wall 70% 50% 30% 70% 50% 30% 50% 30% 10%

1 68 66 65 67 65 64 63 61 602 64 61 59 63 60 58 58 56 543 60 56 53 59 55 52 54 51 494 57 52 48 56 51 48 50 47 445 53 47 43 52 47 43 46 42 406 50 44 39 49 43 39 42 39 367 46 40 36 46 39 35 39 35 328 43 36 32 42 36 32 35 31 299 40 33 29 39 32 28 32 28 2510 37 30 26 36 30 26 29 25 23

Zonal Lumens SummaryZone Lumens %Lamp %Fixture

0-30 2300 27.4 45.30-40 3708 44.2 73.00-60 5066 60.3 99.80-90 5074 60.4 100.0

90-180 0 0 00-180 5074 60.4 100.0

2PMO G B 3 CF40 12LSReport LSI 7534S/MH (along) 1.3 (across) 2.1Coefficient of UtilizationCeiling 80% 70% 50%Wall 70% 50% 30% 70% 50% 30% 50% 30% 10%

1 71 70 68 70 68 67 66 64 632 67 64 61 66 63 60 61 59 573 63 59 56 62 58 55 56 54 524 60 54 50 58 54 50 52 49 475 56 50 46 55 49 45 48 44 426 52 46 42 51 45 41 44 41 387 49 42 38 48 42 37 41 37 348 45 38 34 44 38 34 37 33 309 42 35 30 41 34 30 34 30 2710 39 32 27 38 31 27 31 27 24

Zonal Lumens SummaryZone Lumens %Lamp %Fixture

0-30 2730 28.9 45.70-40 4495 47.6 75.20-60 5973 63.2 99.90-90 5978 63.3 100.0

90-180 0 0 00-180 5978 63.3 100.0

Luminance Summary - cd/m2

Angle Along 45 Across

45 7814 8833 364955 1654 1309 8065 8 8 875 0 0 085 0 0 0

Luminance Summary - cd/m2

Angle Along 45 Across

45 6831 7240 499755 1391 1672 9665 24 9 975 0 0 785 0 0 23

Page 6: INTENDED USE - Pennsylvania State University · 0 909090 888888 848484 1 848178 827977 767473 2 777268 767167 686562 3 716560 706459 615754 4 665852 645752 555147 5 615246 595146

© 1995 Lithonia Lighting, Rev. 6/00

PMO2X23.p65

COMMERCIAL & INDUSTRIAL FLUORESCENT LIGHTINGP.O. BOX A, CONYERS, GEORGIA 30012, TELEPHONE 770-922-9000, FAX 770-860-3106

PMO 2’x2’ 3 Lamps, Optimax

Example: 2PMO G B 3 17 12LD 120 GEB

MOUNTING DATA

Series

2PMO OptimaxLight ControlSystem, 2'wide

Air function

A Air supply/return (slotsin side trim)

H Heat removal(through lampcavity,dampersavailable)

D CombinationA & H

B Static (no airfunction,matchingappearance)

Numberof lamps

3Not included.

Trim type

G GridF Overlapping

flangedMT Modular fit-inST Screw slot

NOTES:

1 Recommended rough-in dimensions for F trim fixtures 24" x 24" (Tolerance is+1/4", -O”). Swing-gate range 1" to 4-3/16", span 23-1/2" to 26-5/16".

PMO 2x2 3LP 12

AppropriateCeiling Type Trim Type

Exposed grid tee GConcealed grid tee G, STConcealed Z-spline F, MTMetal pan (consult factory) MTScrew slot (consult factory) STAcoustical tile, plaster, or plasterboard Fon rigid support parallel to lamps

ORDERING INFORMATION

Louver finish

LD Low iridescentdiffuse silver

LS Low iridescentspecular silver

Numberof cells

12 3 rows of 4

Lamp type

17 17W T8 (24")20 20W TS T12 (24")

U31 31W T8U lamp (24")

CF40 40W RS CF (24")

Voltage

120, 277, 347,MVOLT1

Othersavailable.

Inches (millimeters). Subject to change without notice.

DIMENSIONS

Options

1/3 One 3-lamp ballastGEB Electronic ballasts, <20% THD

GEB10IS Electronic ballast, <10% THD, Instant StartGEB10RS Electronic ballast, <10% THD, Rapid Start

EL Emergency battery pack (nominal 300lumens; see Life Safety Section)

GLR Internal fast-blow fuseGMF Internal slow-blow fuse

PWS1836 6' prewire, 3/8" dia., 18-gauge, 3 wiresLP__ Lamped, specify lamp type and colorHRD Heat-removal dampersAPB Air-pattern control blades (A & D models

only)CRE Flanged trim for continuous row mounting

(end)CRM Flanged trim for continuous row mounting

(middle)PAF Painted after fabrication (white enamel)CSA Listed and labeled to comply with Canadian

StandardsNOM Listed and labeled to comply with Mexican

StandardsJP16 Palletized & stretch-wrapped (16 per), G

and MT trim only

Continuous row mounting of flanged units requiresCRE and CRM trim options (see Options).

NOTE:

1 MVOLT available with GEB10IS only.

2PMO 3

Appendix V-1