intermedium • endodontic ruler filesterilizable in autoclave Östby frame- angelus frame for...

2
STERILIZABLE IN AUTOCLAVE ÖSTBY FRAME- ANGELUS FRAME FOR ABSOLUTE ISOLATION Indication Rubber dam support Advantages • Non-deformable points: fabricated in high performance polymer performance • Anatomical shape: fits patient’s face Presentation Ref. 350 • Östby Frame - Angelus - 1 unit RUBBER DAM SHEET RUBBER DAM SHEET FOR ABSOLUTE ISOLATION Indication Absolute isolation Advantages • High tensile strength • Uniform latex with no streaks • Scented ( tui-frui) • The only with ligatures Presentation Ref. 360 • Rubber Dam Sheets – 26 units SILICONE STOP STOPS FABRICATED WITH SILICONE Indication • For working length determination in files during endodontic procedures Advantages • Hospital grade silicone: sterilizable in autoclave and dry heat • Pre-perforated in center: to direct file insertion Presentation Ref. 700 • Silicone Stops - 100 units FREE 12 LIGATURES ENDOMETRIC SUPPORT FOR ENDODONTIC FILES Indication • For the support of files during endodontic procedures Advantages • Resistant to contact with chemicals: fabricated in high performance polymer • Availability of refills Presentations Ref. 800 • Endometric - 1 support + 30 fabric supports Ref. 802 • Refill for Endometric - 50 units STERILIZABLE IN AUTOCLAVE AnD DRy hEAt IntermedIum • CALIBRATING GAUGE RULER FOR GUTTA-PERCHA POINTS Indications • Calibration of standardized gua-percha points • Preparation of intermediate sizes of gua-percha points Advantages • CE Mark: certification of quality Presentation Ref. 854 • Intermedium termoplastic - 1 unit CAlIbRAtIon AnD PREPARAtIon oF IntERmEDIAtE PoIntS ENDODONTIC ruler • MILLIMETRIC ENDODONTIC RULER Indication • For measurement in Endodontics Advantages • CE Mark: certification of quality • Lightness: fabricated in high performance polymer • Resistant to contact with chemicals Presentation Ref. 850 • Endodontic ruler - 1 unit STERILIZABLE IN AUTOCLAVE AnD DRy hEAt RUlERS AnD ACCESSoRIES

Upload: phamdien

Post on 29-Dec-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: IntermedIum • enDoDontic ruler fileSterilizable in autoclave Östby Frame- angelus Frame For absolute isolation indication • rubber dam support advantages • Non-deformable points:

Sterilizable in autoclave

Östby Frame- angelusFrame For absolute isolationindication •rubber dam support

advantages•Non-deformablepoints: fabricated in high

performance polymer performance•Anatomicalshape:fits patient’s face

PresentationRef.350•ÖstbyFrame-Angelus-1unit

rubber Dam sheetrubber Dam sheet For absolute isolationindication •absolute isolation

advantages•Hightensilestrength•Uniformlatexwithnostreaks• Scented(tutti-frutti)• Theonlywithligatures

PresentationRef.360•RubberDamSheets–26 units

silicone stopstoPs FabricateD with siliconeindication •Forworkinglengthdeterminationinfilesduring

endodontic procedures

advantages•Hospitalgradesilicone:sterilizable in autoclave

and dry heat• Pre-perforatedincenter:to direct file insertion

PresentationRef.700•SiliconeStops-100units

FREE12 liGatureS

enDometricsuPPort For enDoDontic Filesindication •Forthesupportoffilesduringendodontic

procedures

advantages•Resistanttocontactwithchemicals:

fabricated in high performance polymer•Availabilityofrefills

PresentationsRef.800•Endometric-1support+30fabricsupportsRef.802•RefillforEndometric-50units

Sterilizable in autoclave AnDDRyhEAt

IntermedIum • calibratingGauGe ruler For Gutta-Percha Pointsindications •Calibrationofstandardizedgutta-perchapoints•Preparationofintermediatesizesofgutta-percha

points

advantages•CEMark:certification of quality

PresentationRef.854•Intermediumtermoplastic-1unit

CAlIbRAtIonAnDPREPARAtIonoF

IntERmEDIAtEPoIntS

enDoDontic ruler • millimetricenDoDontic rulerindication•FormeasurementinEndodontics

advantages•CEMark:certification of quality• Lightness:fabricated in high performance

polymer•Resistanttocontactwithchemicals

PresentationRef.850•Endodonticruler-1unit

Sterilizable in autoclave AnDDRyhEAt

RUlERSAnDACCESSoRIES

Page 2: IntermedIum • enDoDontic ruler fileSterilizable in autoclave Östby Frame- angelus Frame For absolute isolation indication • rubber dam support advantages • Non-deformable points:

•v

1 2 3

mta - angelusreParative cementindications •treatment of perforations ( root canal and furcation)•Sealing of internal resorption and communicating internal resorption•reverse filling in periapical surgery•Directpulpcappingandpulpotomy(permanentanddeciduous

teeth)•apexification and apexigenesis•intracoronal sealing prior to internal bleaching of root canal treated

teeth•Apicalplugpriortorootcanalfillingincaseofwideapex

advantages•Releaseofcalcium:enhances formation of mineralized tissues;

provides biological sealing of perforations and total repair of damaged periradicular tissues.•Onlydentalmaterialcapableofinducingneoformationofperiradicularcementu•Friendlytohumidenvironment:does not lose properties due to

moisture of oral tissues•Highalcalinity: bactericidal•Lowsolubility:does not disintegrate•Biocompatibletooraltissues•Adequatecompressivestrength•Moreradiopaquethandentinandbone•Shortersettingtimethansimilarcements

PresentationsRef.820•mtA-Angelus7applications(gray)1gofmtA-Angelus-3mlofdistilledwater-01scoopRef.821•mtA-Angelus14applications(gray)2gofmtA-Angelus-3mlofdistilledwater-01scoopRef.822•mtA-AngelusWhite7applications1gofmtA-AngelusWhite-3mlofdistilledwater-01scoopRef.824•mtA-AngelusWhite2applications0.28gofmtA-AngelusWhite-3mlofdistilledwater

clinical casesradiographs gently provided by:*Prof.Dr.Clóvism.bramante.**Prof.Dr.RicardoAffonsobernardes.***Prof.Dr.EudesGondin.****Prof.Dr.DaniloShimabuko.*****Prof.Dr.marcosJacobovitz.

•Apexification/Apexigenesis****

Prof.Dr.RobertohollandStudyconcludedinAugust2001

Formation oF calciFication barriermicrographsobserve calcite granulation (arrow) inside the dentin tubules and mta angelus (m) inside tube. Polarized light (80X).

under sem, basophile areas (arrow) showing calcification and connective tissue with few inflammatory cells of the chronic type (1oo X).it can be concluded that the results were similar to previous tests with other mtas.

mta - angelus was placed inside dentin tubes, which were implanted in subcutaneous connective tissue of rats from 7 to 30 days. the samples were removed and prepared without decalcification.

mta Fillapexmta-baseD enDoDontic sealerindication•Forthefillingofrootcanal

vantagens•Paste/pastesystem:easy to use•Applicatortips:easy to apply•Excellentflow:provides filling of accessory

canals•Adequateworkingtime:35minutes•Adequatesettingtime:130minutes•Highradiopacity:greatradiographicview•Lowsolubility: maintenance of filling

integrity and better sealing•Easyremovalincaseofnecessarycanalreentry

PresentationsRef.828•mtAFillapex12g+mixingpad+20automixtips+5multi-UsetipsRef.827•mtAFillapexrefill4g+5automixtips

multi-use tipsaPPlicator tiPsindications•irrigation and suction•Insertion/aplicationofmedicamentsin

root canals advantages•Plastic:do not corrode; atraumatic•Flexible:adjustable to root canal curvatures •Extremelythin:easily reach root canal tip (0,014”)•Universalattachment:adapt to all types of

syringes PresentationRef807•20units

Properties MTAFillapex

Pelliclethickness 39,6µm

Flow 27,66mm(averagediameter)

radiopacity (optical density) 77%

Solubility 0,1%

testsbyPIVA,E.-biomaterialsDepartment–PelotasFederalUniversityAccordingtoInternationalStandardISo6876

SettinG time: 15mInUtES

FIRStPAStE/PAStEmtA-bASED

root canal Sealer

•Rootcanalperforation**

•Furcationperforation**

universal attachment

Precise adaptation

•Pulpotomy*

•Resorption*****

•Directpulpcapping*

•Reverserootfilling***

EnDoDontICSCEmEntS

aPPlicator tiPS

new product

new product