Product Test Report (1 of 2) Controlled Temperature Hours HT-AL-40 (NHS) International Haotian Technology Co. Ltd. An ISO9001:2015 Company International Haotian Technology Co. Ltd. An ISO9001:2015 Company 1. Cold Chain Shipper: HT-AL40 (NHS) 2. Insulation: 30 mm Closed Cell XPS Foam 3. Type of test: Minimum user performance of 12 hours +2 to +8 Deg.C, in an ambient temperature of 16 Deg.C 4. Test Method: 1. Five pieces of HTBH285 IceBricks containing water + SAP (Self Absorbent Polymer) were placed in a freezer set at - 15 deg. C, for a period of 24 hrs. 2. A vaccine load consisting of 6 layers of packed vaccine vials was prepared and placed in a refrigerator set at 2 deg.C, for a period of 24 hours. Cold Space Dimensions: 34*26*31 (h) cms Layer Pack Dimensions: 26*26*20 (h) cms Number of Layers: 6 Vials per Layer: 100 Total Vials: 600 Mass per Layer: 383 grams Total Mass: 2300 grams Gross of Vaccine package 2.6 kg Volume Density of Vaccine Pack: 0.192 grams/cm 3 Ratio Cold Space Volume to Payload Volume: 2.03 1 X Class A RTD Temperature sensor was placed at the geometric centre of the top layer, and 1 x RTD sensor was placed at the geometric centre of the fourth layer. 3. The HTIceBricks were removed from the freezer and conditioned by laying flat in room temperature until the surface temperature reached 0 deg.C. 4. The HTIceBricks were placed in the pockets, an RTD Sensor placed centrally 50 mm below the top HTIceBrick, and the lid was closed and secured. 5. On the cold space temperature reaching +2 deg.C, the vaccine pack was removed from the refrigerator, and placed in the cold space 6. The RTD sensor leads were taken out through a rear corner of the lid, connected to a calibrated Laboratory Class Data Recorder, and the lid secured with the Velcro fixings. 7. The AL-40 (NHS) Cold Chain Box was was placed in a thermal test facility at an average ambient temperature of +23 o C. Cool Ice Box Company Ltd. 27 Broad St., South Melton, Devon EX36 3AQ, UK +44 800 051 6788 +33 553836230 1 of 3

Upload: others

Post on 17-Nov-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Product Test Report (1 of 2)

Controlled Temperature Hours HT-AL-40 (NHS)

International HaotianTechnology Co. Ltd.

An ISO9001:2015 Company

International HaotianTechnology Co. Ltd.

An ISO9001:2015 Company

1. Cold Chain Shipper: HT-AL40 (NHS)

2. Insulation: 30 mm Closed Cell XPS Foam

3. Type of test: Minimum user performance of 12 hours +2 to +8 Deg.C, in an ambient temperature of 16 Deg.C

4. Test Method:

1. Five pieces of HTBH285 IceBricks containing water + SAP (Self Absorbent Polymer) wereplaced in a freezer set at - 15 deg. C, for a period of 24 hrs.

2. A vaccine load consisting of 6 layers of packed vaccine vials was prepared and placed in a refrigerator set at 2 deg.C, for a period of 24 hours.

Cold Space Dimensions: 34*26*31 (h) cmsLayer Pack Dimensions: 26*26*20 (h) cmsNumber of Layers: 6Vials per Layer: 100Total Vials: 600Mass per Layer: 383 gramsTotal Mass: 2300 gramsGross of Vaccine package 2.6 kgVolume Density of Vaccine Pack: 0.192 grams/cm3

Ratio Cold Space Volume to Payload Volume: 2.03

1 X Class A RTD Temperature sensor was placed at the geometric centre of the toplayer, and 1 x RTD sensor was placed at the geometric centre of the fourth layer.

3. The HTIceBricks were removed from the freezer and conditioned by laying flat in room temperature until the surface temperature reached 0 deg.C.

4. The HTIceBricks were placed in the pockets, an RTD Sensor placed centrally 50 mm

below the top HTIceBrick, and the lid was closed and secured.

5. On the cold space temperature reaching +2 deg.C, the vaccine pack was removed from the refrigerator, and placed in the cold space

6. The RTD sensor leads were taken out through a rear corner of the lid, connected to a calibrated Laboratory Class Data Recorder, and the lid secured with the Velcro fixings.

7. The AL-40 (NHS) Cold Chain Box was was placed in a thermal test facility at an average ambient temperature of +23oC.

Cool Ice Box Company Ltd.27 Broad St., South Melton, Devon EX36 3AQ, UK

+44 800 051 6788 +33 5538362301 of 3

Tina
Textbox
Tina
New Stamp
Tina
Textbox
Tel: 0843 277 777
Tina
Textbox
Molton
Tina
Textbox

Product Test Report (1 of 2)

Controlled Temperature Hours HT-AL-40 (NHS)

International HaotianTechnology Co. Ltd.

An ISO9001:2015 Company

5. Test Results:

1. Test Period: 48 hours2. Ambient Temperature: 23 Deg.C3. Lowest Recorded Temperature: +2.00 Deg.C4. Close of Box to +8 Deg.C: 32.37 hrs.5. +2 Deg.C to +8 Deg.C: 32.37 hrs6. Grams SAP+Water/litre of cold space: 57 grams/litre

6. Conclusion

The cold life performance meets and exceeds the requirements, giving a large margin for safety in emergency situations, or higher ambient temperatures.

[Russell 2020-11-28]

ISO9001:2015

Cool Ice Box Company Ltd.27 Broad St., South Melton, Devon EX36 3AQ, UK

+44 800 051 6788 +33 5538362302 of 3

Tina
Textbox
Tina
New Stamp
Tina
Textbox
0843 277 7770
Tina
Textbox
Tina
Textbox
Molton
Tina
Textbox

Product Test Report (1 of 2)

Controlled Temperature Hours HT-AL-40 (NHS)

International HaotianTechnology Co. Ltd.

An ISO9001:2015 Company

AL-40 (NSH) Cold Chain Shipper as Tested

Cool Ice Box Company Ltd.27 Broad St., South Melton, Devon EX36 3AQ, UK

+44 800 051 6788 +33 5538362303 of 3

Thermal Performance Test Payload

Tina
Textbox
0843 277 7770
Tina
Textbox
Molton
Tina
Textbox
Tina
New Stamp
Tina
Textbox