introduction to biosensors
DESCRIPTION
Introduction to Biosensors. Prof. Xingwei Wang. 1. Brain Storm. What do you think of biosensor?. 2. Brain Storm. What do you think of biosensor?. -- Detection of anthrax biological threat?. -- Glucose meters?. -- QCM?. -- Food safety?. -- Biology? Engineering?. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/1.jpg)
11
Introduction to Introduction to BiosensorsBiosensors
Prof. Xingwei WangProf. Xingwei Wang
![Page 2: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/2.jpg)
22
Brain StormBrain Storm
What do you think of biosensor?What do you think of biosensor?
![Page 3: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/3.jpg)
33
Brain StormBrain Storm
What do you think of biosensor?What do you think of biosensor?
![Page 4: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/4.jpg)
44
Significance & Great DemandsSignificance & Great Demands
Food safety
Public Health Pathology
Criminology
Civil defense
Environmental Monitoring
![Page 5: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/5.jpg)
55
Brief HistoryBrief History 1956, Prof. Clark, Father of biosensor concept, Invention of the oxygen 1956, Prof. Clark, Father of biosensor concept, Invention of the oxygen
electrodeelectrode 1962, First description of a biosensor1962, First description of a biosensor 1972/5, First commercial biosensor: Yellow Springs Instruments glucose 1972/5, First commercial biosensor: Yellow Springs Instruments glucose
biosensorbiosensor 1975, First immunosensor1975, First immunosensor 1980, First fibre optic pH sensor for 1980, First fibre optic pH sensor for in vivoin vivo blood gases blood gases 1983, First surface plasmon resonance (SPR) immunosensor1983, First surface plasmon resonance (SPR) immunosensor 1987, Launch of the MediSense ExacTech™ blood glucose biosensor1987, Launch of the MediSense ExacTech™ blood glucose biosensor 1990, Launch of the Pharmacia BIACore SPR-based biosensor system1990, Launch of the Pharmacia BIACore SPR-based biosensor system 1992, i-STAT launches hand-held blood analyser1992, i-STAT launches hand-held blood analyser 1996, Abbott acquires MediSense for $867 million1996, Abbott acquires MediSense for $867 million 1998, Launch of LifeScan FastTake blood glucose biosensor1998, Launch of LifeScan FastTake blood glucose biosensor 1998, Merger of Roche and Boehringer Mannheim to form Roche 1998, Merger of Roche and Boehringer Mannheim to form Roche
DiagnosticsDiagnostics 2001, LifeScan purchases Inverness Medical's glucose testing business for 2001, LifeScan purchases Inverness Medical's glucose testing business for
$1.3billion$1.3billion
![Page 6: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/6.jpg)
66
What is a BiosensorWhat is a Biosensor
A device that uses biological components e.g. A device that uses biological components e.g. enzymes to indicate the amount of a enzymes to indicate the amount of a biomaterialbiomaterial
Trace biomaterial?
– Unnecessary (Eg. Metal ion, etc.)
Quantitative results?
– Unnecessary (Eg., Pregnancy test)
![Page 7: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/7.jpg)
77
ComponentsComponents
Bio Recognition Element
Enzymes; Antibodies; Receptors; Whole cells...
Electrochemical
Optical
Transducer
Signal Output
Requires: Sample Immobilization
Requires:Simple read out and data interpretation;Easy to use;Quick response.
![Page 8: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/8.jpg)
88
Performance FactorsPerformance Factors
Sensitivity: Concentration; weightSensitivity: Concentration; weight Specificity/Selectivity: discriminate between Specificity/Selectivity: discriminate between
substratessubstrates Speed: Bench->Chip->Real TimeSpeed: Bench->Chip->Real Time Accuracy: False signalAccuracy: False signal CostCost Easy to useEasy to use Life timeLife time
![Page 9: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/9.jpg)
99
Biosensing for MacromoleculesBiosensing for Macromolecules
Steps:Steps: ImmobilizationImmobilization MixingMixing Washing the non-specific bindingsWashing the non-specific bindings Signal transductionSignal transduction
Markers:Markers: EnzymesEnzymes Fluorescence tagsFluorescence tags Radioactive tagsRadioactive tags
Molecular:Molecular: Waston-Crick Base Waston-Crick Base
pairingpairing Antibody-Antigen Antibody-Antigen
bindingbinding
![Page 10: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/10.jpg)
1010
ImmunosensorImmunosensor
Antibody can be againstAntibody can be against BacteriaBacteria Complex carbohydratesComplex carbohydrates Smaller organic moleculesSmaller organic molecules
![Page 11: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/11.jpg)
1111
DNA Complementary ChainsDNA Complementary Chains
Four nitrogen basesFour nitrogen bases Complementary chainsComplementary chains
C
G
A
T
C G
A T
![Page 12: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/12.jpg)
1212
Six StepsSix Steps1)1) Select the single-stranded capture DNA sequenceSelect the single-stranded capture DNA sequence
2)2) Attach the capture DNA strand to a probeAttach the capture DNA strand to a probe
3)3) Introduce the samples to be identified to the probesIntroduce the samples to be identified to the probes
4)4) Hybridization will occur if the sample is Hybridization will occur if the sample is complementary with the capture sequence on the complementary with the capture sequence on the probeprobe
5)5) Wash away the remaining unattached samplesWash away the remaining unattached samples
6)6) JudgmentJudgment
![Page 13: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/13.jpg)
1313
TransducerTransducer
Electrochemical (Potentiometric, Electrochemical (Potentiometric, Voltammetric, Amperometry, Conductimetric)Voltammetric, Amperometry, Conductimetric)
Optical (Fluorescence, Absorbance, Light Optical (Fluorescence, Absorbance, Light scattering, Refractive index)scattering, Refractive index)
Mechanical, Thermal, Piezoelectric, MagneticMechanical, Thermal, Piezoelectric, Magnetic
![Page 14: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/14.jpg)
1414
Glucose SensorGlucose Sensor
http://www.ul.ie/elements/Issue6/Biosensors-%20Elements.htm
![Page 15: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/15.jpg)
1515
MicrocantileversMicrocantilevers
From http://www.ornl.gov/info/ornlreview/rev29_3/text/biosens.htm
![Page 16: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/16.jpg)
1616
Medical TelesensorMedical Telesensor
From http://www.ornl.gov/info/ornlreview/rev29_3/text/biosens.htm
• Military: Locate wounded soldiers•Domestic: Intensive patients
• An array of chips to monitor body functions•Wireless transmission
![Page 17: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/17.jpg)
1818
Broad Potential ApplicationsBroad Potential Applications
(Picture from www.primordial.com/.../Hardware_Soldier_w640.png)
Warfighter Physiological Status Monitoring (WPSM): remote triage of injured SoldiersHeart rate, breaths taken, skin temperature and ballistic impactFoster-Miller (Waltham, Mass.) Putting these sensors on a belt that's sewn into a shirt
![Page 18: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/18.jpg)
1919
BenefitsBenefits
Industry Military
Academia
Biosensor
![Page 19: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/19.jpg)
2020
Challenges and TrendChallenges and Trend
CostCost SensitivitySensitivity SelectivitySelectivity SpeedSpeed Small?Small? Ease to use?Ease to use?
CheapCheap SensitiveSensitive SelectiveSelective SpeedSpeed PortablePortable SimpleSimple IntegratedIntegrated Mass producedMass produced Multiple analytesMultiple analytes
![Page 20: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/20.jpg)
2121
Multidisciplinary NatureMultidisciplinary Nature
Biosensor Chemistry
Biology
PhysicsInstrumentation
Electronics
Optics
Market
![Page 21: Introduction to Biosensors](https://reader033.vdocument.in/reader033/viewer/2022061400/5681392b550346895da0d2d0/html5/thumbnails/21.jpg)
2222
Worldwide Biosensor Vendor Market, Worldwide Biosensor Vendor Market, 20032003