is 4049-2 (1996): formed ends for tanks and pressure

14
Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public. इंटरनेट मानक !ान $ एक न’ भारत का +नम-णSatyanarayan Gangaram Pitroda “Invent a New India Using Knowledge” प0रा1 को छोड न’ 5 तरफJawaharlal Nehru “Step Out From the Old to the New” जान1 का अ+धकार, जी1 का अ+धकारMazdoor Kisan Shakti Sangathan “The Right to Information, The Right to Live” !ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता ह Bharthari—Nītiśatakam “Knowledge is such a treasure which cannot be stolen” IS 4049-2 (1996): Formed ends for tanks and pressure vessels, Part 2: Based on inside diameter basis [MED 17: Chemical Engineering Plants and Related Equipment]

Upload: others

Post on 23-Dec-2021

7 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: IS 4049-2 (1996): Formed ends for tanks and pressure

Disclosure to Promote the Right To Information

Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public.

इंटरनेट मानक

“!ान $ एक न' भारत का +नम-ण”Satyanarayan Gangaram Pitroda

“Invent a New India Using Knowledge”

“प0रा1 को छोड न' 5 तरफ”Jawaharlal Nehru

“Step Out From the Old to the New”

“जान1 का अ+धकार, जी1 का अ+धकार”Mazdoor Kisan Shakti Sangathan

“The Right to Information, The Right to Live”

“!ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता है”Bhartṛhari—Nītiśatakam

“Knowledge is such a treasure which cannot be stolen”

“Invent a New India Using Knowledge”

है”ह”ह

IS 4049-2 (1996): Formed ends for tanks and pressurevessels, Part 2: Based on inside diameter basis [MED 17:Chemical Engineering Plants and Related Equipment]

Page 2: IS 4049-2 (1996): Formed ends for tanks and pressure
Page 3: IS 4049-2 (1996): Formed ends for tanks and pressure
Page 4: IS 4049-2 (1996): Formed ends for tanks and pressure

IS 4049 (Part 2) : 1996(Reaffirmed 2001 )

(Tf&fT~ )

Indian Standard

FORMED ENDS FOR TANKS ANDPRESSURE VESSELS - SPECIFICATION

PART 2 INSIDE DIAMETER BASIS

( First Revision)

First Reprint MAY 2006

res 23.020.10; 23.020.30

© BIS 1996

BUREAU OF INDIAN STANDARDSMANAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARG

NEW DELHI 110002

REAFFI61MEO

Z006

October 1996 Price Group 3

Page 5: IS 4049-2 (1996): Formed ends for tanks and pressure

AMENDMENT NO.1 JULY 2006TO

IS 4049 (PART 2) : 1996 FORMED ENDS FOR TANKSAND PRESSURE VESSELS - SPECIFICATION

PART 2 INSIDE DIAMETER BASIS

( First Revision)

(Page 1, clause 4.3 ) - Substitute following for the existing clause:

'4.3 Length of the Straight Flange - The length of the straight flange shallnot be less than three times the end thickness with a minimum of 38 rom, unlessotherwise agreed to between the manufacturer and the purchaser. '

(ME 17)

Reprography Unit, BIS, New Delhi, India

Page 6: IS 4049-2 (1996): Formed ends for tanks and pressure
Page 7: IS 4049-2 (1996): Formed ends for tanks and pressure

Chemical Engineering Plants and Related Equipment Sectional Committee, HMD 17

FOREWORD

This Indian Standard (Part 2) (First Revision) was adopted by the Bureau of Indian Standards, after thedraft finalized by the Chemical Engineering Plants and Related Equipment Sectional Committee had beenapproved by the Heavy Mechanical Engineering Division Council.

This standard was first published in 1979. This revision of the standard is being brought out to bringit in line with the latest practices being followed in the country. The important modifications being:

a) length of the straight flange revised from 20 rom minimum to 38 mm minimum;

b) tolerance on circularity, that is the difference between the maximum and minimum diameterincreased; and

c) provision of shallow dished and flanged ends having knuckle radius of 6 percent withdrawn.

Formed ends are used as end closures for pressure vessels, receivers and similar equipments. IS 2825:1969'Code for unfired pressure vessels' specifies anyone of the following shapes for the ends:

a) Hemispherical,

b) Semi-ellipsoidal,

c) Dished and flanged, and

d) Conical.

In this specification only semi-ellipsoidal,dished and flanged ends are covered. The code for unfired pressurevessels (IS 2825:1969) also permits deeper or slightly shallower semi-ellipsoidal ends and dished and flangedends deeper than those specified in this standard. But these shapes are considered 'special' and have not,therefore, been included.

The formed ends are designated either on outside diameter basis or inside diameter basis. The Part 1of this standard covers formed ends on outside diameter basis while this Part 2 of the standard coversformed ends on inside diameter basis.

The information to be supplied by the purchaser to the manufacturer along with the enquiry or order isgiven in Annex A.

For the purpose of deciding whether a particular requirement of this standard is complied with, the finalvalue, observed or calculated, expressing the result of a test or analysis, shall be rounded off in accordancewith IS 2:1960 'Rules for rounding off numerical values (revised)'. The number of significant places retainedin the rounded off value should be the same as that of the specified value in this standard.

Page 8: IS 4049-2 (1996): Formed ends for tanks and pressure

IS 4049 (part 2) 1996

Indian StandardFORMED ENDS FOR TANKS AND

PRESSURE VESSELS - SPECIFICATIONPART 2 INSIDE DIAMETER BASIS

(First Revision)1 SCOPE

This standard (Part 2) specifies the profile dimensionsand technical delivery conditions of dished andflanged, pressed or spun ends designed on the basisof inside diameter commonly used as end closuresof pressure vessels, receivers, tanks and similarequipments.

1.1 Where the ends have reinforced or flanged-inmanholes, it is recommended that they are made tothe same geometric shape as the plain ends.

2 REFERENCE

This standard makes reference to IS 2825:1969 'Codefor unfired pressure vessels' which is a necessaryadjunct to this standard.

3 TYPES OF ENDS

3.1 The ends shall conform to one of the followingshapes.

3.1.1 Deep dished and flanged ends with an internalheightof dishing hi approximately equal to one-quarterof the inside flange diameter D. for pressure vessels,either

a) of semi-ellipsoidal shape with the innercontour of a true ellipse having an axis ratioof2: I with inside diameter as given in Table 1

or

b) of torispherical shape (see Table 1).

3.1.2 Dished and flanged ends with an internal heightof dishing h. slightly less than one-fifth of the insideflange diameter D, suitable for pressure vessels (seeTable 2).

3.1.3 Shallow dished and flanged ends for tanks andother non-pressure vessels (see Table 3).

NOlES

1 IS 2825: 1969 specifies that in the case of dished and flangedends, the inside radius of dishing (Knuckle radius) shall preferablybe not less than 10 percent of the inside diameter and in no caseless than 6 percent of the inside diameter or three times the thicknesswhichever is more.

2 In the case of ends of partial spherical form. the Internal heightof dishIng hi and external height of dishing ho can be determinedas follows:

h, =R1 - (R, - DJ.. x (R, + DI..- 2 r,)2 2

ho = R.- (Ro - f!) x (Ro + l!.. .- 2 r)2 2

where

D, inner diameter of dished end,

Do outer diameter of dished end.

Ro outer crown radius.

R, Inner crown radius.

ro outer knuckle radius. and

rl

inner knuckle radius.

4 DIMENSIONS

4.1 Flange and Dishing Diameter

The inside diameter, the inside crown radius andinside knuckleradius shall conform to the requirementsof Tables 1, 2 and 3.

4.2 Thickness

4.2.1 Minimum thickness is the thickness measuredat the thinnest point after manufacture of the dishedends. Nominal thickness is the thickness of the plateused in manufacturing of the dished end.

4.2.2 The minimum thickness shall be supplied bythe purchaser based on internal/external pressure andother design loading inclusive of corrosion/erosionallowance as per IS 2825: 1969. For non-pressurevessels and tanks, the minimum thickness shall be asagreedto between the purchaser and the manufacturer.

4.3 Length of the Straight Flange

Minimum length of the straight flange shall be threetimes the end thickness but need not exceed 38 mmexcept when necessary to provide required length oftaper.

4.4 Tolerances

The ends shall be true to shape within the limitsspecified in 4.4.1 to 4.4.4 below, unless more stringenttolerances are specified by the purchaser.

4.4.1 Circumference

The inside circumference of the straight flange ofthe finished end shall not depart from thecircumference calculated from the inside diameter bymore than the values given below:

Inside diameter upto ± 5 mmand including 400 mm

Inside diameter over ± 0.25 percent400 mm

Page 9: IS 4049-2 (1996): Formed ends for tanks and pressure

IS 4049 (Part 2) : 1996

4.4.2 Circularity

The difference between the maximum and theminimum inside diameters of the straight flange shallnot exceed one percent of inside diameter and shallin no case be greater than D1 + 2500

200

4.4.3 Thickness

From the point where the crown radius R. joins theknuckle radius r. and at the point where the knuckleradius rj joins the straight portion of the flange end,a gradual thinning is permissible up to maximum of10percent of the nominal thickness or 2 rom whicheveris higher. A similar gradual thinning is permissiblefor ends of semi-ellipsoidal shape. Due to gatheringof material, the thickness in the straight portion ofthe flange may increase. This shall not exceed 15percent of the nominal thickness of the plate.Thickness of the thinnest point of dished end shallnot be less than the minimum thickness specified bythe purchaser.

NOTE - Where dished ends are provided with flanges inmanholes. the thinning is permissible up to a maximum of 40percent of the nominal thickness on the major axis and 15percent of the nominal thickness on the minor axis.

4.4.4 J>rollle

The inside depth of dishing h. shall. not be less thanthe theoretical depth nor shall this depth exceed bymore than 1.25 percent of the inside diameter D, ofthe dished end.

S MATERIAL

The material of construction shall be carbon steelor low alloy or high alloy steel or non-ferrous metal.The exact specification shall be specified by thepurchaser in his order.

6 TECHNICAL DELIVERY CONDITIONS

The following details regarding technical deliveryconditions for dished ends shall be included.

6.1 Heat-Treated Conditions

The dished ends shall be delivered in heat-treatedcondition depending upon the process of dishing,temperature of dishing and the material specification.Heat treated condition of dished end is a subject ofagreement between the manufacturer and thepurchaser.

6.2 Workmanship

6.2.1· Descaling shall be carried out to measure thedimensions and to carry out visual inspection. Dishedends shall be free from any injurious defects.

6.2.2 Projection, depressions or elongated groovesusually developed during dishing are permissible solong as these depressions are not sharp and theirdepth is within the tolerance limits specified on theplate. Sharp grooves, laminations and other surfacecracks shall be completely removed by grinding orany other suitable method.

2

6.2.3 Where depressions exceed the tolerance limitsspecified on the plate, such depressions shall beremoved by grinding or by welding with thepermission of the purchaser by an approved weldingprocedure. Hammering of surface defects is notpermitted.

6.2.4 The heat treatment and radiography requirementsshall be in accordance with IS 2825:1969.

6.3 Testing of Dished Ends for Material Quality

To ensure that the material properties are not impairedduring the manufacture of dished ends, samples takenfrom dished ends after the final heat treatment shallbe subjected to mechanical test for tensile strength,impact strength where necessary (for low temperatureapplication) and bend tests as specified in the relevantspecification for the plate material. The location oftest plates is subject to agreement between themanufacturer and the purchaser and may be one ofthe following:

a) Extended portion cut out from the straightflange.

b) Opening cut out for nozzles

c) Separate test plates from the same melt andheat number subjected to simulation similarto the. dished ends.

6.4 For high alloy steel (austenitic steels in particular,dished end subjected to hot forminglheat treatment)requirement of intergranular corrosion test to checkfor carbide precipitation is to be carried out, whereverspecified and agreed upon between the purchaser andthe supplier.

6.S In case of dished end manufactured by spinningprocess, the dished end is to be subjected to dyepenetrant examination on the outside surface ofknuckle region. If desired before by the purchaserit may be carried out on inside surface knuckle regionalso.

7 MARKING

7.1 The dished ends shall be marked with thefollowing:

a) Inside diameter,b) Type of dished end,c) Minimum thickness,d) Material of construction, ande) Identification of the source of manufacturer.

7.2 BIS Certification Marking

The dished ends may also be marked with the StandardMark.

7.2.1 The use of the Standard Mark is governed bythe provisions of the Bureau ofIndian Standards Act,1986 and the Rules and Regulations made thereunder.The details ofconditions under which the licence forthe use of the Standard Mark may be granted tomanufacturers or producers may be obtained {romthe Bureau of Indian Standards.

Page 10: IS 4049-2 (1996): Formed ends for tanks and pressure

IS 4049 (part 2) 1996

Table 1 Dimensions for Deep Dished and Flanged Ends (Torispherical)(Clauses 3.1.1 and 4.1)

All dimensions in millimetres.

¢D;

Inside Crown Inside Length ofDiameter Radius Knuckle Straight

D, R I Radius Flanger, S,

(I) (2) (3) (4)

400 320 60

500 40() 80

600 480 100

700 560 125

800 640 125

900 720 150

'1 000 800 150

I 100 880 175

I 200 960 200

I 300 1 040 200

I 400 I 120 250

I 500 I 200 250

I 600 1 280 250

I 700 I 360 300

I 800 1 440 300

1 900 I 520 300

2 000 J 600 300 See 4.3

2 100 1 680 350

2 200 1 760 350

2 300 1 840 350

2 400 1 920 400

2 600 2080 400

2800 2240 450

3000 2400 450

3 200 2560 500

3 400 2640 600

3600 2 880 600

3 800 3040 600

4000 3 200 600

4 250 3400 700

4500 3600 700

4 750 3800 800

5000 4 000 800

N01E - As sizes below 400 correspond to pipe caps, the dimensions shall conform to the outside diameters of pipes.

3

Page 11: IS 4049-2 (1996): Formed ends for tanks and pressure

IS 4049 (part 2) : 1996

Table 2 Dimensions for Dished and Flanged Ends (Torispherical)(Clauses 3.1.2 and 4.1)

All dimensions in millimetres.

¢Di

Inside Crown Inside Length ofDiameter Radius Knuckle Straight

D1 R. Radius FlangeT1 Sf

(I) (2) (3) (4)

400 400 40500 500 50600 600 60700 700 75800 800 80900 900 100

1000 1000 1001 100 1 100 1251 200 1200 1251 300 1300 150

1.400 1400 1501 500 1 500 1501600 1600 1751 700 1 700 1751800 I 800 200I 900 I 900 2002000 2000 200 See 4.3

2 100 2 100 2502200 2200 2502300 2300 2502400 2400 2502600 2600 3002800 2800 3003000 3000 3003200 3200 3503400 3400 3503600 3600 4003800 3800 400

4000 4000 4004250 4250 450

4500 4500 4504 750 4750 5005000 5.000 500

NOlE- As sizes below 400 correspond to pipe caps, the dimensions shall conform to the outside diameters of pipes.

4

Page 12: IS 4049-2 (1996): Formed ends for tanks and pressure

IS 4049 (Part 2) : 1996

Table 3 Dimensions for Shallow Dished and Flanged Ends for Tanks and Non-pressure Vessels(Clauses 3.1.3 and 4.1)

All dimensions in millimetres.

Inside CroWD Inside Length ofDiameter Radius Knuckle Straight

D. R. Radius Flange

'1 S,

(i) .(2) (3) (4)

900 950 50

1000 1200 50

I 100 1400 50

I 200 I 500 50

I 300 1700 50

i 400 1700 50

I 500 I 800 50

I 600 2000 50

I 700 2200 50

I 800 2400 50

I 900 2600 50

2000 2800 50

2 100 3000 50

2·200 3300 50 See 4.3

2300 3300 50

2400 3300 50

2600 3300 50

2 800 3500 50

3000 3600 50

3200 4000 50

3400 4000 50

3600 5000 SO

3 800 5000 50

4000 5000 50

4 250 5500 50

4500 5500 50

4750 5500 50

5000 5500 60

5

Page 13: IS 4049-2 (1996): Formed ends for tanks and pressure

IS 4049 (Part 2) 1996

ANNEX A(Foreword)

INFORMATION TO BE SUPPLIED BY THE PURCHASER

A·I The purchaser shall supply the followinginformation to the manufacturer with the enquiry ororder:

a) Type of dished end required;

b) Inside diameter in millimetres;

c) Material of construction of the dished end;

d) Method of heat treatment;

e) Minimum and nominal thickness of the dishedend;

6

f) Radiography and any other non-destructivetesting, if required;

g) Length of straight flange;h) Whether the flange is to be machined and

weld preparation required;j) Special requirements for the welded joints

in a dished end made from more than oneplate;

k) Inspection or survey requirements; andm) Manhole or any connection details, if required.

Page 14: IS 4049-2 (1996): Formed ends for tanks and pressure

Bureau of Indian Standards

BlS is a statutory institution established under the Bureau of Indian Standards Act, 1986 to promoteharmonious development of the activities of standardization, marking and quality certification of goodsand attending to connected matters in the country.

Copyright

BIS has the copyright of all its publications. No part of these publications may be reproduced in anyform without the prior permission in writing of BIS. This does not preclude the free use, in course ofimplementing the standard, of necessary details, such as symbols 'and sizes, type or grade designations.Enquiries relating to copyright be addressed to the Director (Publications), BIS.

Review of Indian Standards

Amendments are issued to standards as the need arises on the basis of comments. Standards are alsoreviewed periodically; a standard along with amendments is reaffirmed when such review indicates thatno changes are needed; if the review indicates that changes are needed, it is taken up for revision. Usersof Indian Standards should ascertain that they are in possession of the latest amendments or edition byreferring to the latest issue of 'BIS Catalogue' and 'Standards: Monthly Additions'.

This Indian Standard has been developed from Doc: No. HMD 17 (0067).

Amendments Issued Since Publication

Amendment No. Date-of Issue Text Affected

BUREAU OF INDIAN STANDARDSHeadquarters:

Manak Bhavan, 9 Bahadur ShallZafar Marg, New Delhi 110 002Telephones: 23230131,2323 3375, 2323 9402 Website: www.bis.org.in

Regional Offices:

Central: Manak Bhavan, 9 Bahadur Shah Zafar MargNEW DELHI 110 002

Telephones

{2323761723233841

Northern: SCO 335-336, Sector 34-A, CHANDIGARH 160022

Southern: C.I.T. Campus, IV Cross Road, CHENNAI 600 113

Western: Manakalaya, E9 MillC, Marol, Andheri (East)MUMBAI 400 093

Eastern: 1/14, C.LT. Scheme VII M, VLP. Road, KankurgachiKOLKATA 700 054 {

23378499:2337'856123378626,23379120

{2603843260

19285,

{2254 1216,2254 144222542519,22542315

{28n 9295, 2832 785828327891, 28327892

Branches: AHMEDABAD. BANGALORE. BHOPAL. BHUBANESHWAR. COIMBATQRE. FARIDABAD.GHAZIABAD. GUWAHATL HYDERABAD. JAIPUR. KANPUR. LUCKNOW. NAGPUR.NALAGARH. PATNA. PUNE. RAJKOT. THIRUVANANTHAPURAM. VISAKHAPATNAM.

Printed at Dee Kay Printers, New Delhi