is ii active implant protocol
DESCRIPTION
IS II active implant protocolTRANSCRIPT
![Page 1: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/1.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II active
![Page 2: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/2.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeØ 4.5 10mm fixture will be placed
2
![Page 3: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/3.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeIncision
3
![Page 4: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/4.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II active
1,200 RPM, 30 ~ 45Ncm
Point Lindemann drilling withirrigation
4
![Page 5: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/5.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II active
1,200 RPM, 30 ~ 45Ncm
Point Lindemann drilling withirrigation
5
![Page 6: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/6.jpg)
D1 D1 : Ø1.2D2 : Ø2.5D2
7
1.3mm0
33.5mm
8.5 10 11.5 13 16.5
D R I L L I N GS E Q U E N C EG U I D E
IS-II activePoint Lindemann drill
Diameter Product nameØ2.5 LDS25
LDSØ
25
6
![Page 7: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/7.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activePositioning for the initial drilling
7
![Page 8: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/8.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II active
1,200 RPM, 30~45Ncm,10mm stopper
Initial drilling(Ø2.2)with irrigation
8
![Page 9: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/9.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II active
1,200 RPM, 30~45Ncm,10mm stopper
Initial drilling(Ø2.2)with irrigation
9
![Page 10: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/10.jpg)
0
33.5mm
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeInitial drill
Diameter Product nameØ2.2
Ø2.2
TSD22FTS
D22
F
7
1.3mm
8.5 10 11.5 13 16.5
10
![Page 11: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/11.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeØ 2.2 depth 10mm hole has appeared
11
![Page 12: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/12.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeChecking the depthwith depth gauge
12
![Page 13: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/13.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeChecking the path with a parallel pin
13
![Page 14: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/14.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeTaking radiography (X-ray)
14
![Page 15: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/15.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeRemoval of the parallel pin
15
![Page 16: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/16.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II active
1,200 RPM, 30~45Ncm,10mm stopper
Twist drilling(Ø2.9)with irrigation
16
![Page 17: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/17.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeØ 2.9 depth 10mm hole has appeared
17
![Page 18: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/18.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II active
1,200 RPM, 30~45Ncm,10mm stopper
Twist drilling(Ø3.4)with irrigation
18
![Page 19: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/19.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeØ 3.4 depth 10mm hole has appeared
19
![Page 20: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/20.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II active
1,200 RPM, 30~45Ncm,10mm stopper
Twist drilling(Ø3.9)with irrigation
20
![Page 21: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/21.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeØ 3.9 depth 10mm hole has appeared
21
![Page 22: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/22.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II active
50 RPM, 50Ncm
Profile tapping(Ø4.5) with irrigation
22
![Page 23: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/23.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeØ 4.5 Tapping has appeared
23
![Page 24: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/24.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II active
Ø 4.5 X 10mm, 25~30 RPM,35Ncm
Fixture placementwith contra angle
24
![Page 25: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/25.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II active
25
![Page 26: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/26.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II active
Initial fixation at the apex isexcellent to both immediate placement and immediateloading
Apex
26
![Page 27: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/27.jpg)
2525
Tighten slowly until it reaches 35Ncm
When Implant is being placed w i t h t o r q u e wrench, 35Ncm is suggested with irrigation
27
![Page 28: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/28.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeConnecting a coverscrew with Ø1.2 hexdriver (by hand)
28
![Page 29: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/29.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeSuture
29
![Page 30: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/30.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II active
1
2
1. Bioseal2. Powerful thread
2 Main Factors for primary fixation duringosseointegration
30
![Page 31: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/31.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II active
Bioseal increases marginal sealing of soft tissue therefore minimizes bone loss.
1.
Powerful thread also calledMagic thread, is specially designed to withstand occlusal and lateral forces.
2.
31
![Page 32: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/32.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeAfter osseointegration,remove the cover screwwith Ø1.2 hex driver(by hand)
32
![Page 33: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/33.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeConnectinga healing abutment
33
![Page 34: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/34.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeAfter soft tissue healing,remove the healingabutment withØ1.2 hex driver(by hand)
34
![Page 35: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/35.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeConnecting solidabutment withØ1.2 hex driver(by hand)
35
![Page 36: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/36.jpg)
Connectingtorque ratchet
36
![Page 37: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/37.jpg)
Tightening withtorque ratchet(Max. 35Ncm)
Tighten slowly until it reaches 35Ncm
37
![Page 38: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/38.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeSeating impression cap over the abutment
38
![Page 39: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/39.jpg)
Taking impression
39
![Page 40: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/40.jpg)
Impression capcomes out withimpression
40
![Page 41: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/41.jpg)
Insert abutmentlevel lab analoginto impression
41
![Page 42: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/42.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeSeating protectivecap over abutmentand fabricatingprovisional restoration
42
![Page 43: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/43.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeWhen finalprosthesis is ready,remove theprotective cap
43
![Page 44: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/44.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II activeCementing thefinal restoration
44
![Page 45: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/45.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II active
1. Bioseal2. Coronal Macro Thread3. S.L.A. Surface treatment
Characteristics of IS-II active Implant that has long-term stability
1
2
3
45
![Page 46: IS II active implant protocol](https://reader031.vdocument.in/reader031/viewer/2022020321/568bef4b1a28ab89338bacf1/html5/thumbnails/46.jpg)
D R I L L I N GS E Q U E N C EG U I D E
IS-II active
IS-II active implant is optimized for maintenance of primary stability with its powerful thread.Soft tissue healing process is predictable due toS.L.A surface treatment composed of macro andmicro pores which allow excellent biosealing.
S.L.A. Surface treatmentBioSeal (0.5mm) Coronal Macro Thread
2.1. 3.
46