nobel active internal hex implant

34
Gerald A. Niznick DMD, MSD 1 NobelActive Internal Hex Implant with Long Lead-in Bevel Nobel Marketing Claims this is the “Implant of the Future”

Upload: maxisurgeon

Post on 09-Dec-2014

2.218 views

Category:

Documents


1 download

DESCRIPTION

 

TRANSCRIPT

Page 1: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 1

NobelActive Internal Hex Implant with Long Lead-in Bevel Nobel Marketing Claims this is the “Implant of the Future”

Page 2: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 2

NobelActive Internal Hex Implant – Modified Alpha Bio Implant Nobel Marketing Claims this is the “Implant of the Future”

Alpha Bio Israeli Implant with 45Deg.

Bevel and Internal Hex

Page 3: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 3

Screw-Vent Internal Hex/bevelNiznick Patent 1986

NobelActive is a Conglomeration of Common Features that work individually but not necessarily in combination

Astra 11Deg. Bevel

Osstem’s double Threads over entire length. NobelActive transition of sharp to flat threads not contusive for self-tapping insertion in dense bone

Oraltronics’ Pitt-Easy

Implant with Deep Apical Threads but

threads consistent over entire

length

NobelActive hex too deep to allow for 8mm implant length

45 Deg. Bevel Bevel with proven 20 year history of stability

Page 4: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 4

1.5mm High External Hex 3.5mm Morse Taper Post

NobelActive External -With External Locking Taper ConnectionNobel Marketing Claims this is the “Implant of the Future”

Page 5: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 5

NobelActive External - 5mm high tapered post requires parallelism Miter Implant with External Post – Evolved quickly to Internal Socket (Bicon)

Driskell Patent 1985: Tapered Post on Implant

“Locking taper concept – impacting the female taper of the implant head with the male counterpart on the root structure.”

Driskell Patent 1988: Tapered Socket in Implant

Locking Taper Concept “The head member has … a tapered rod

or socket for connection to the root”

“Those who cannot remember the past are condemned to repeat it” QUOTATION: George Santayana (1863–1952), U.S. philosopher,

Page 6: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 6

NobelDirect Bone Loss

Articles and Regulatory Problems

NobelPerfect $600 Implant Claiming to be

Solution for “Black Hole”

esthetic Problem

Tapered Groovy with diminishing

apical threads and no cutting

groove

NobelActive Niznick 1986 Internal Hex, Pitt-Easy deep apical threads, Osstem double threads, Alpha

Bio Clone

Nobel Biocare’s History of “Innovation” for Innovation Sake Are Nobel’s Exiting Implants the “Implants of the Past?

Page 7: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 7

A Camel is a Horse Designed by a Committee

NobelActive Internal

NobelActive External

Page 8: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 8

Research: 1 Poster + 2 “Ongoing” Nobel Company Studies

Page 9: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 9

NobelActive (TiUnite) and Alpha Bio’s SFB (SLA) Implants BUT Nobel claims 98.3% Alpha Bio study applies to its new implant

ABOVE: Nobel Claims NobelActive success of “98.3% for up to 4 years” BELOW: Alpha Bio’s Catalog Claims same 98.3% success “after more than 5 years” but the surface is SLA (sand blasted with large grit followed by acid etching) like Straumann’s Surface

Page 10: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 10

Nobel Claims NobelActive Functions like “Corkscrew” Close Evaluation indicates they should have left it in the bottle

Page 11: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 11

Nobel Biocare’s NobelActive Marketing Claims

1. “bone-condensing – expands indication range and gives even higher initial stability.”

2. “self-drilling”3. “ability to change

direction during surgery”4. “unique press-fit

connection of abutment – 5. -removes risk of excess

cement”6. NobelActive Internal and

External implants don’t cut through bone like

1. Higher than What – Replace? Increased stability achieved by spreading bone whereas deep threads cut bone

2. Self-threading – like any screw in soft bone.

3. Path of implant insertion should be established during surgery, not during implant insertion. That is what guide pins and end-cutting drills are for.

4. Nothing unique about press-fit connection. Miter Implant (1980) had external tapered post – evolved to internal press-fit connection of Bicon

5. If cement is a risk, why does NobelActive Internal have a screw-retained connection?

6. Why does NobelActive have spiral cutting grooves if not to “cut through bone like conventional (self-tapping) implants”?

NobelActive Marketing Claims Questionable Validity of Marketing Claims

conventional implants, they press through it like a corkscrew

Page 12: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 12

1. It is not a “one-piece implant – requires an abutment.

2. Does not have 2-piece flexibility – Can not use angled heads greater than 12 degrees, ball, screw-receiving or ceramic abutments. Require parallel placement of implants for bridges.

3. A one-piece implant eliminates “micro gap” but a precise-fitting internal connections maintain marginal integrity anyway. Nobel still sells external hex implants – less stable

1. “One piece implant

2. design with 2-piece flexibility”

3. locking tapered interface .. Eliminates bone level micro gap, micro-movement and the use of abutment screws.”

NobelActive External Claims Claims are not Valid

Page 13: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 13

Precision Manufacturing of Internal Connection Prevents both Micro-Movements and Micro-Gap

Abutment

ScrewPlant Implant

Screw Precision Fit

Cross-section of Abutment On ScrewPlant Implant

Page 14: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 14

Compare Fit of ScrewPlant from Implant Direct, and the Screw-Vent Clone from Alpha Bio, the Israeli Implant Company owned by NobelActive Developer

ScrewPlant – External Bevel Connection from Implant Direct

Alpha Bio, Israeli Company owned by Dr Fromovitch, NobelActive Developer

SBM to top

Blast Surface 3mm Short of the top Note Pitted Surface and Gap

Note Micro-threads and Sealed Margin

Page 15: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 15

Very deep threads apically cuts rather than compresses soft bone - any screw implant will self-tap in soft bone.

NobelActiveNo Taper to OD

of Threads

ScrewPlantGradual Taper for

Bone Expansion

Deep apical threads will not expand narrow ridge or compress soft bone

Soft Bone (Balsa) = 3.91 in/lbs Insertion TorqueHard Bone (Oak) = 6.35 in/lbs Insertion Torque

NobelActive™ ClaimThe product is easy to use and provides high initial stability and good outcomes. The Apical Threads are too aggressive for self-tapping insertion in Dense bone and are designed to cut threads in soft bone rather than expand and compress the bone for increased initial stability. Any Implant will self-tap in soft bone.

Page 16: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 16

Dense Bone Drill is 4.2mmD but Platform is 3.9mmDNobelActive Leaves Gap around neck of Implant in Dense Bone

Page 17: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 17

Dense Bone Drill is 4.6mmD but Platform is 3.9mmDNobelActive Leaves Gap around neck of Implant in Dense Bone

Page 18: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 18

Compare NobelActive External Hex with ScrewDirect One-Piece Implant

The Prosthetic Advantages are Obvious & Cost Savings Significant

NobelActive ExternalRequires Attachment of one

of these four abutments

ScrewDirect $150 incl. Snap Transfer & Cap

Page 19: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 19

Attach & Remove Long Friction Fit Head to NobelActive

Straight Friction-fit abutment too longHeads of Implant exposed above bone

Tried to remove abutment with Forceps

Page 20: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 20

Attach Two Short Friction Fit Heads to NobelActive using Mallet

Jack off abutment using Removal Screw Shorter Abutment attached to Implants

Shorter Abutment attached to Distal Implant Tap on Taper Lock Abutments with Mallet

Page 21: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 21

Need for parallelism is what dictates need to re-direct implantEstablish alignment with paralleling pins and end-cutting drills

Page 22: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 22

Preferred placement is angled between buccal and lingual platesStraight Post of NobelActive External requires vertical placement

Page 23: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 23

NobelActive vs RePlus Implant From Implant DirectWhy Change Drills and Platforms, just to change threads?

NobelActive

1. RePlus has Tri-Lobe Connection 2. Both have Platform switching

interface – of questionable value3. RePlus has even taper and even

depth to threads to allow insertion into an undersized socket for bone expansion,

4. NobelActive has no taper to outside threads and extreme taper to inside thread dimension

5. RePlus has Mini-threads whereas NobelActive has horizontal grooves.

6. RePlus major diameter is at top of implant whereas NobelActive 4.3 & 5.0 implants are narrower at top, leaving gap in dense bone

7. RePlus has double lead threads on body for faster insertion.

RePlus Implant

Page 24: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 24

ProActive with Tri-Lobe Connection and Platform SwitchingProjected Launch Date – January 2008

• Same taper to body as RePlus Implants allow insertion in undersized socket for expansion

• Flat-based deeper threads provide increased surface area for greater stability in soft bone

Page 25: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 25

ProActive Implant Provided on Fixture-Mount that is Transfer and can be shortened to Final, Platform Switching Abutment

Page 26: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 26

Get Connected to All-in-one Packaging, Simplified On-line Ordering and Unprecedented Low Prices

www.implantdirect.com

[email protected]. Jerry Niznick, President

Page 27: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 27

Page 28: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 28

Page 29: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 29

Page 30: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 30

Page 31: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 31

Page 32: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 32

Page 33: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 33

Page 34: Nobel Active Internal Hex Implant

Gerald A. Niznick DMD, MSD 34