s2 internal hex implant

44
S2 Internal Hex Implant

Upload: jacob-azulay

Post on 17-Mar-2016

233 views

Category:

Documents


7 download

DESCRIPTION

Dentalis S2 Internal Hex Implant

TRANSCRIPT

Page 1: S2 Internal Hex Implant

S2

Internal

Hex

Implant

Page 2: S2 Internal Hex Implant

For USA Only: Federal Law restricts this device to sale by or the order of licensed dentist or physician

Dentalis Bio Solutions USA9650 E 148th StNoblesville, 46060Indiana, USAPhone: 317-214-7076

For more info please refer to WWW.dentalis.us or to your local distributor

Dentalis Bio Solution complies withISO 13485, ISO 14001 and Council Directive 93/42/EEC

Canadian Medical Devices Regulation.

Page 3: S2 Internal Hex Implant

All rights reserved. No Part of this publication may be reproduced, transcribed, stored in an electric retrieval system and translated into any language or computer language without the prior written consent of the Dentalis Bio Solution R&D.

Who we areDentalis BioSolutions R&D is focused on becoming a leader in the application of nanotechnology, bioinorganic materials with wider functionalities “intelligent” bone substitutes life sciences. We strive to become the new industry standard for detection of molecular protein-Hormone-growth factor interactions.

Dentalis R&D department is a unique combination of individual parts.We have assembled multi-disciplinary teams of scientists with diverseresearch and technical knowledge and life experiences.

Our project teams are made of organic chemists, biologists, physicists, biochemists, and materials science engineers working side by side toward common goals.

Our product development specialize in a wide range of fields, focusing on orthopedic and dental implant, research of Surface Science and Technology encompasses both analysis and modification of surfaces.

Our offerDentalis offers an extensive variety of bone and tissue level implantsfor all indication and bone types, which satisfies every clinician and selected treatment concept, such as one and two stage surgical,immediately or delayed loading protocol, solutions for a wide clinical situations from the basic to the most complex with wide range of length implants from 20 mm to 6.5 mm, wide & short implant, Narrow implant Ø 3 mm diameter designed specifically for limited spaces in the esthetic zone and limited ridge.

All Dentalis implant are made from Titanium Alloy [Ti-6Al-4V] whichis biocompatible medical grade. The surface of All Dentalis implant is roughened by biocompatible material (HA) and is free from any contamination (Aluminum oxide and acid traces).

Our beliefWe believe that creativity and innovation in orthopedics implant anddentistry requires vision and commitment to patient quality of life. We are convinced that this focus must permeate and inspire everythingwe do, every day.

Our commitmentWe are devoted to continue on providing high quality, groundbreaking oral healthcare solutions that create value for dental professionals and enhance their patients’ quality of life

Dentalis follows the most strict international quality standards, complying with ISO 13485:2003 quality management system for :Design, development & manufacture of Orthopedics, Bone Screw,Dental implant, Plates and other medical instrument.T

he P

erf

ect

Matc

h ™

Page 4: S2 Internal Hex Implant

Disclaimer of LiabilityDentalis implants is a part of an overall concept and may only be used in conjunction with the associated original components and instruments according to Dentalis instructions and recommendations.Use of any non- Dentalis products in conjunction with Dentalis implants will avoid any warranty Or any other obligation, expressed or implied, of Dentalis.Instructions as to application of our products take place verbally, in writing, by electronic media or in hands-on training corresponding to state of the art at the time of introduction of the product.

The user of Dentalis product has the duty to determine whether or not any product is suitable for the particular patient and circumstances. Dentalis disclaims any liability, express or implied, and shall have no responsibility for any direct, indirect, punitive or other damage, aris-ing out of or in connection with any errors in professional judgment or practice in the use or installation of Dentalis products.

Please noteThe descriptions given are insufficient to allow immediate use of the Dentalis dental Implant Systems. Guidance in the handling of this instrument by a doctor experience in their use is strongly recommended.Unit per packageUnless stated otherwise, there is one unit in each package.

AvailabilityNot all product listed in this brochure are available in all countries.

Validity Upon publication of this brochure, all previous versions are superseded.

Caution As a general rule, our product must be secured against aspiration when used intra-orally.

Copyright and trademarksAll rights reserved. Dentalis documents may not be reprinted No Part of this publication may be reproduced, transcribed, stored in an electric retrieval system and translated into any language or computer language without the prior written consent of the Dentalis Bio Solution R&D, Dentalis- Dental implants system, Versatile implant, T1, S2, D2, Micro Cortical thread, BAS surface are registered trademarks .Some products may not be regulatory cleared/released for sale in all markets and not all may have been licensed in accordance with Canadian law. Please contact the local Dentalis sales office for current product range and availability.

Valid from 1 January 2013 until publication of new catalog.Note:In order to improve readability, Dentalis Bio Solutions does not use ™ or ® in the running text. By doing so, however, Dentalis does not waive any right to the trademark or registered mark and nothing here in shall be construed to the contrary.The following third-party trademarks apply:Ankylos® is a trademark of Dentsply Friadent Group, Astra Tech® of Astra Tech Group, Bredent™ of Bredent GmbH & Co. KG, Camlog® of Camlog Biotechnologies Group, Dolder® and Dalbo® of Cendres+Metaux SA, Lifecore® Biomedical Restore of Lifecore Biomedical Group, Locator® of Zest Anchors Inc, Sterngold® Implamed of Sterngold Group, Straumann® of Institut Straumann AG, Telio® CAD and IPS e.max® CAD of Ivoclar Vivadent AG, 3i® of Biomet Group, Thommen® of Thommen Medical AG, and Zimmer® Dental of Zimmer Group.

Dentalis Bio Solution complies withISO 13485, ISO 14001 and Council Directive 93/42/EEC

Canadian Medical Devices Regulation.

Page 5: S2 Internal Hex Implant

contentsExplanation of the symbol 1

BAS Surface 2-3

S2 – Screw Implant 3-8 S2 Narrow implant 3 mm 4-5 S2 Standart Platform 6-8

Healing Abutment 14-15

Screw Type & Cemented Rehabilitation 16-43

Temporary Abutment 16 Plastic structure for casting 17 Non Hex Abutment 18 Straight Abutment 18-19 Zirconium Abutment 20 Angled Abutment 21 Anti-Rotation Aestheic Abutmen 22 Straight adaptor 23

Overdenture 24-26 Ball Attachment Abutment 24-25 Angular Ball Attachment Abutment Locator Abutment 26

Implant impression Transfer Analog & Transfer 27-28

Surgical Kits, Tools, Surgial Drllis 30-30

Drivers & Tools 31 Drills -External Irrigation 34-35 Drills- Conical 36 Ceramic Drill 36 Counter Sink 37 Trephine Burs 37 Sinus Kit 38 Paralel Pin 38 Osteotomes Kit 39 Professional Implantology Tools 40

Page 6: S2 Internal Hex Implant

1

Extra Important when using Dentalis ImplantsWe strongly recommend that practitioners, new as well as experience implant user, always go through special training before undertaking a new treatment method.A training model and two dummy implants are also delivered with the surgical kit. Dentalis Bio Solution provides wide range of courses for various levels of knowledge.

Dentalis Bio Solutions USA, 9650 E 148th St, Noblesville, 46060, Indiana, USA

All products are subject to change without notice.Some products may not be available in all markets

Please contact your local Dentalis Office for current product assortment and availabilty

Explanation of the symbols on labels and instructions for use

Attention,refer to instructions for use

Dentalis products carry the CE mark andfulfill the requirment of the medical Decices Directive 93/42 EEC

Use Before expiry date

Do not use if package is damaged

Protect from exaposre to light or heat

Lot / batch number/codeCatalogue number

Sterlilzed using gamma irradiation

Temperature limitation

Caution:Federal (USA)law restricts thisproduct to sale directly to, or on the order of a licened dentist

Single Use Do not re-sterilize.

Manufaturer Date of manufactre

GOST is the valid quality certificationsystem in Russian Federation.

non-sterile

xxxx identify the notified body ofmanufacturer

Keep away from sunlight

Page 7: S2 Internal Hex Implant

2

BAS™ SurfaceBio Active Surface

Introduction: Implant success is dependent on the osseointegration process.Successful osseointegration of bone growth around an implant is dependent on substrate properties, including surface morphology, chemical composition and surface energy.Dentalis’s dental implant innovation was developed and tested in three essential research levels and has the advantages to enhanceimmediate and successful osseointegration. Dentalis’s new implants encompass unique and advanced implant macrotopography.Dentalis’s implant’s chemical composition is well characterized.Dentalis’s implant surface was produced with specific micron scale surface structures.Dentalis’s implants were examined and established under in vitro cell culture studies and in vivo conditions. In vitro findings have established that these specific surface structures enhanced osteoblast attachment, proliferation, differentiation, and mineralization. In vivo studies have confirmed the osteogenic effect of microstructureson Ti substrates. These surfaces improved bone to implant contact (BIC) in comparison with smooth surfaced implants, and this was correlated with greater removal torque strength.These observations suggest that Dentalis implants, inspired bybone biology, will improve your clinical performance and outcome.

For more info about BAS ™ Surface and the Scientific Research Documentation In vitro & In vivo experiments please contact yourlocal distributor.T

he P

erf

ect

Matc

h ™

Page 8: S2 Internal Hex Implant

3

Roughness analysis Dentalis Surface roughness is achieved from grit-blasting using a unique combination of the HA particles (soluble) with different size of grains. This process provide the surface itsoptimal structural roughness and enables the incorporation of biocompatibleparticles such as HA and TCP.

BAS ™ surface

Determination of Ra valuesRoughness was measured with an average roughness (Ra), the most commonly used parameter for describing roughness, was calculated in microns. The rough surfaces produced by grit-blasting had irregular geometries with Ra value of 3.0 μm, which isconsidered optimal for the osseointegration process.

Biological Response - In Vitro Study Dentalis’s implant surface is the result of comprehensive scientific research.The surface characteristics of dental implants to optimize the biological response. Research on Dentalis surface examine the next properties: Alkaline phosphatase as an early marker of differentiation and reaches its highest levels as mineralization is initiated.Osteocalcin is a late marker of differentiation and increases as mineral is deposited.Prostaglandin E2 is required for osteoblast activity and prostaglandins mediate cell responseto surface structure.Most of the transforming growth factor beta-1 secreted by MG63 cells on microstructured Ti surfaces is stored in latent form, and the amount is sensitive to surface structure. These growth factors stimulate matrix synthesis and differentiation of osteoblasts and also inhibit osteoclasts.

In vivo :studies have confirmed the osteogenic effect of microstructures on Ti substrates. These surfaces improved bone to implant contact (BIC) in comparison with smooth surfacedimplants, and this was correlated with greater removal torque strength.These observations suggest that Dentalis implants, inspired by bone biology, will improve your clinical performance and outcome.

For more info about BAS ™ Surface and the Scientific Research DocumentationIn vitro & In vivo experiments please contact your local distributor.

Scanning Electronic Microscopy (SEM) of implant surface Dentalis surface, the roughening process produces a larger and cleaner surface.

Page 9: S2 Internal Hex Implant

4

Prod

uct i

llust

ratio

ns a

re n

ot sc

ale

The S2 Implant Narrow Platform

The New S2 Ø 3 and Ø 3.3 mm diameter is designed specifically for limited spaces in the Esthetic zone and is placed easily with 2.0 and 2.5mm drills.

This type of implants merging the latest technologies designed and surface treatment to provide excellent treatment in challenging medical situations.

Dentalis S2 implants 3mm design to offers restorative flexibility in narrow spaces. The Ø 3mm threadform shown to be effective when immediately loaded.

S2 can be use to Treat small spaces with confidence. The small diameter of the Dentalis implant is specially designed for the placement of single-unit maxillary lateral incisors, as well as mandibular and central incisors.

Placing small diameter implants is confident, Our implants material provides high strengthand improved assurance when placing Narrow diameter implants, while the BAS™ surface accelerates the osseointegration Process, provide short time healing and helps deliverpredictability in implant treatment.

S2 offer Variety of possibilities treatments options, Variety ranging prosthetic options with internal hex connection including screw retained and cement-retained restorations and variety possibilities of implant-level or abutment level impression workflow.

* Small diameter implants are not recommended for use in the molar region.* Thread form shown to be effective when immediately loaded.* Fatigue strength according to ISO 14801 For more info please contact your local distributor

Impl

ants

Page 10: S2 Internal Hex Implant

5

Ø 2

Ø 2

.5

Ø 2

.8

S2Ø 3.0

Drill Speed (RPM)900-1200

900-1200

800-1000

500-700

Drill Diameter (mm) Ø 1.8 Ø 2 Ø 2.5 Ø 2.8

Recommendation :to reduce the pressure in the bone around the implant neck:Bone Type D1 use the last drill up to 1/3 depth.Bone Type D2-3 use the last drill to the depth of the cortex.Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 3.0Ø in soft bone (D4) use the 2.5 Ø drill as a final drill just for the cortex.

S2 – Screw ImplantBody Diameter Ø 3mm Apical Diameter 2.8 mm

Minimum Ridge Width 5.0 mm

Minimum Mesial / Distal Space 6.0 mm

Micro & Mini Ring 3 mm | NP-Narrow Platform

No Machined Collar Height Length mm 10 11.5 13 16

Cat. No. 113010 113011 113013 113016

Healing Abutment Narrow Platform

L:2,3,4,5Page : 14

Cover ScrewInclude with all implants.Use the Hand Driver-tightenwith the 1.25mm- 050”Hex Driver.

Straight Abutment Page :18

Angled Abutment 15° Narrow Platform

Page :21

Ball Attachment Narrow Platform

Page :24L:2,3,4,5

HD- 1 Hex Driver Narrow Platform

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.

Page 11: S2 Internal Hex Implant

6

S2 – Screw ImplantBody Diameter Ø 3.3mm Apical Diameter 3.0 mm

Minimum Ridge Width 5.3 mm

Minimum Mesial / Distal Space 6.3 mm

Micro & Mini Ring 3 mm | NP-Narrow Platform

No Machined Collar Height Length mm 10 11.5 13 16

Cat. No. 113310 113311 113313 113316

Ø 2

Ø 2

.5

Ø 2

.8

Ø 3

.2

S2Ø 3.3

Drill Speed (RPM)900-1200

900-1200

800-1000

500-700

400-700

Drill Diameter (mm) Ø 1.8 Ø 2 Ø 2.5 Ø 2.8 Ø 3.2

Recommendation :to reduce the pressure in the bone around the implant neck:Bone Type D1 use the last drill up to 1/3 depth.Bone Type D2-3 use the last drill to the depth of the cortex.Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 3.3Ø in soft bone (D4) use the 2.8 Ø drill as a final drill just for the cortex.

Cover ScrewInclude with all implants.Use the Hand Driver-tightenwith the 1.25mm- 050”Hex Driver.

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.

Page 12: S2 Internal Hex Implant

7

Page 13: S2 Internal Hex Implant

8

S2Dentalis S2™ is a two-pieces implants, slightly tapered with more pronounced apical taper allowing for under prepartion. with his desined S2 is recommenended for all bone typs, S2 can achive high primary stability in soft bone, and he is excellent for bone type 1 and 2 .

S2 has Dual thread and Dual spiral channels With his designed S2 provide shorten drilling protocols, it is self driling, self tapping and self condensing bone .

S2 has the advantage to preserving the marginal bone with:

Horizontal grooves produced by micro-machiningimpedes epithelial down growth on titanium implants.

Micro threads provide enhanced initial stability and increases contact area to crestal bone, which willenhance osseointegration at the crestal bone level.

Platform switching enables good adaptation of the gingival tissues to the abutment and prevents cervical bone resorption.

with variety of length from 6.5 mm to 18 mm and range of Diamter from 3 mm to 6 mm S2 can provide clinical solutionfrom the basic to the most challenge situation.

Page 14: S2 Internal Hex Implant

9

S2 Implant range Standard Platform

Implants

S2 – Screw ImplantBody Diameter Ø 3.75mm Apical Diameter 2.8 mm

Minimum Ridge Width 5.25 mm

Minimum Mesial / Distal Space 6.25 mm

Micro & Mini Ring 3 mm | SP-Standard Platform

No Machined Collar Height | Platform SwitchingLength mm 6.5 08 10 11.5 13 16

Cat. No. - 113708 113710 113711 113713 113716

Drill Speed (RPM)900-1200

900-1200

800-1000

500-700

400-700

400-600

Drill Diameter (mm) Ø 1.8 Ø 2 Ø 2.5 Ø 2.8 Ø 3.2 Ø 3.6

Recommendation :to reduce the pressure in the bone around the implant neck:Bone Type D1 use the last drill up to 1/3 depth.Bone Type D2-3 use the last drill to the depth of the cortex.Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 3.75Ø in soft bone (D4) use the 3.2 Ø drill as a final drill just for the cortex.

Ø 2

Ø 3

.2

Ø 3

.6

Ø 2

.5

Ø 2

.8

S2Ø 3.75

Cover ScrewInclude with all implants.Usethe Hand Driver-tighten withthe 1.25mm- 050” Hex Driver.

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.

Page 15: S2 Internal Hex Implant

10

For U

SA O

nly:

Fed

eral

Law

rest

ricts

this

devi

ce to

sale

by

or th

e or

der o

f lic

ense

d de

ntist

or p

hysic

ian

Impl

ants

S2 – Screw ImplantBody Diameter Ø 4.2mm Apical Diameter 3.2 mm

Minimum Ridge Width 5.75 mm

Minimum Mesial / Distal Space 6.75 mm

Micro & Mini Ring 3 mm | SP-Standard Platform

No Machined Collar Height | Platform SwitchingLength mm 6.5 08 10 11.5 13 16 18

Cat. No. 114206 114208 114210 114211 114213 114216 114218

Drill Speed (RPM)900-1200

900-1200

800-1000

500-700

400-700

400-600

400-600

Drill Diameter (mm) Ø 1.8 Ø 2 Ø 2.5 Ø 2.8 Ø 3.2 Ø 3.6 Ø 4.1

Recommendation :to reduce the pressure in the bone around the implant neck:Bone Type D1 use the last drill up to 1/3 depth.Bone Type D2-3 use the last drill to the depth of the cortex.Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 4.2 Ø in soft bone (D4) use the 3.6 Ø drill as a final drill just for the cortex.

Ø 4

.1

S2Ø 4.2

Ø 2

Ø 3

.2

Ø 3

.6

Ø 2

.5

Ø 2

.8

Cover ScrewInclude with all implants.Usethe Hand Driver-tighten withthe 1.25mm- 050” Hex Driver.

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.

Page 16: S2 Internal Hex Implant

11

S2 – Screw ImplantBody Diameter Ø 4.7mm Apical Diameter 3.2 mm

Minimum Ridge Width 5.75 mm

Minimum Mesial / Distal Space 6.75 mm

Micro & Mini Ring 3 mm | SP-Standard Platform

No Machined Collar Height | Platform SwitchingLength mm 6.5 08 10 11.5 13 16

Cat. No. 114706 114708 114710 114711 114213 114216

Drill Speed (RPM)900-1200

900-1200

800-1000

500-700

400-700

400-600

400-600

300-500

Drill Diameter (mm) Ø 1.8 Ø 2 Ø 2.5 Ø 2.8 Ø 3.2 Ø 3.6 Ø 4.1 Ø 4.6

Recommendation :to reduce the pressure in the bone around the implant neck:Bone Type D1 use the last drill up to 1/3 depth.Bone Type D2-3 use the last drill to the depth of the cortex.Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 4.7Ø in soft bone (D4) use the 4.1 Ø drill as a final drill just for the cortex.

Ø 2

Ø 3

.2

Ø 3

.6

Ø 4

.1

Ø 4

.6

Ø 2

.5

Ø 2

.8

S2Ø 4.7

Cover ScrewInclude with all implants.Usethe Hand Driver-tighten withthe 1.25mm- 050” Hex Driver.

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.

Page 17: S2 Internal Hex Implant

12

S2 – Screw ImplantBody Diameter Ø 5.0mm Apical Diameter 3.2 mm

Minimum Ridge Width 5.75 mm

Minimum Mesial / Distal Space 6.75 mm

Micro & Mini Ring 3 mm | SP-Standard Platform

Machined Collar Height 0.5mm | Platform SwitchingLength mm 6.5 08 10 11.5 13 16

Cat. No. 115006 115008 115010 115011 115013 115016

Drill Speed (RPM)900-1200

900-1200

800-1000

500-700

400-700

400-600

400-600

300-500

Drill Diameter (mm) Ø 1.8 Ø 2 Ø 2.5 Ø 2.8 Ø 3.2 Ø 3.6 Ø 4.1 Ø 4.6

Recommendation :to reduce the pressure in the bone around the implant neck:Bone Type D1 use the last drill up to 1/3 depth.Bone Type D2-3 use the last drill to the depth of the cortex.Bone Type D4 use the one before last drill desirable to the depth of the cortex For example:Implant diameter 5.0Ø in soft bone (D4) use the 4.6 Ø drill as a final drill just for the cortex.

Ø 4

.1

Ø 4

.6

Ø 4

.8/ 5

.8

S2Ø 5

Ø 2

Ø 3

.2

Ø 3

.6

Ø 2

.5

Ø 2

.8

Cover ScrewInclude with all implants.Usethe Hand Driver-tighten withthe 1.25mm- 050” Hex Driver.

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.

Page 18: S2 Internal Hex Implant

13

S2 – Screw ImplantBody Diameter Ø 6.0mm Apical Diameter 3.2 mm

Minimum Ridge Width 5.75 mm

Minimum Mesial / Distal Space 6.75 mm

Micro & Mini Ring 3 mm | SP-Standard Platform

Machined Collar Height 0.5mm | Platform SwitchingLength mm 6.5 08 10 11.5 13 16

Cat. No. 116006 116008 116010 116011 116013 116016

The

Drill

ing

sequ

rnce

is d

emon

trat

ed b

y a

13 m

m im

plan

t

Drill Speed (RPM)900-1200

900-1200

800-1000

500-700

400-700

400-600

400-600

300-500

300-500

Drill Diameter (mm) Ø 1.8 Ø 2 Ø 2.5 Ø 2.8 Ø 3.2 Ø 3.6 Ø 4.1 Ø 4.6 Ø 05.2

Implants

Recommendation :Bone Type D1 use the last drill up to 1/3 depth.Bone Type D2-3 use the last drill to the depth of the cortex.Bone Type D4 use the one before last drill desirable to thedepth of the cortex For example : Implant diameter 3.75Ø insoft bone (D4) use the 3.2 Ø drill as a final drill just for the cortex.

Ø 4

.8/ 5

.8

Ø 5

.8

Ø 2

Ø 2

.5

Ø 2

.8

Ø 3

.2

Ø 3

.6

Ø 4

.1

Ø 4

.6

Ø 5

.2

S2Ø 6

Cover ScrewInclude with all implants.Usethe Hand Driver-tighten withthe 1.25mm- 050” Hex Driver.

Procedure recommended by Dentalis implants cannot replace the judgment and the experience ot the surgeon.

Page 19: S2 Internal Hex Implant

14

Indication of use Healing AbutmentThe Healing Abutment is specially designed to avoid bone grow on platform and to developing soft tissue emergence with Narrow, Regular, Wide Emergence or simple solutionsinternal system prosthetic components, by that to prepare for the specially designed bridge impression coping and remains in the jaw until soft tissue (the gums) heal. To be used as a transmucosal extraction extension secures to the implant during healing of intra-oral soft tissue following insertion of the implant to the bone or after second stage surgery.For esthetic result use appropriate Healing caps type, selected height a function of the thickness of the gums. Select the emergence profile that best suits the site being restored. The profile should match the transfer and abutment to be used Select the cuff height so that the top of the component protrudes slightly above the surrounding thickness tissue gums. The options are from 2mm to 7mm.

Placement of the Healing abutment After radiographic verification, a healing abutment screw is then placed, after uncovery two stage surgical protocol. Or in lieu of a Cover screw in a single-stage (non submerged) protocol.Prior to seating the Healing Abutment, thoroughly irrigate the inside of the implant to remove blood and other debris. An antibacterial paste may be placed on the screw portion to decrease the risk of bacterial growth within the implant body during the healing phase. Following seating, irrigate the surgical site and adapt the soft tissue in normal surgical fashion.A gingivectomy or apically positioned flap technique may be used to reduce the soft tissue thickness and to decrease sulcular depth around the implant. All Dentalis® keys are design that the tip is con to grab the healing cap for easy carry the Cover Screw onto the implant and thread it into place. Use the Hand Driver-tighten (10-15 Ncm) with the 1.25mm- 050” Hex Driver. Dentalis implant is offering special tool for measuring the high level of the tissue for better esthetic result and wide range type of Healing abutment.Take precautions to prevent the Healing Abutment from being aspirated by the patient.Do not re-use Healing abutment.Material Titanium

Healing ProtocolsCover Screw Caps for two-stage protocolPurpose: Protects prosthetic-platform in two-stage (submerged) surgical protocols.Irrigate implants to remove blood and other debris, Remove Cover Cap from implant vial with 0.50”(1.25mm)Hex Driver, Hand- tighten(10-15 Ncm) utilizing 0.50”(1.25mm)Hex Driver An Antibacterial paste may be places on the end of the Cover Screw Cap to help decrease the risk of bacterial growth within the implant body during the healing phase.Following placement of the Cover Screw Cap, the surgical site should be irrigated and soft tissue adapted in a normal surgical fashion.Take precautions to prevent the Cover Screw Cap from being aspirated by the patient.Material Titanium

Page 20: S2 Internal Hex Implant

15

H

Healing abutment Regular Ø 4.7

H:2mm300402

H:3mm300403

H:5mm300405

H:7mm300407

Healing Abutment Esthetic

H:3mm300603

H:4mm300604

H:5mm300605

Cat. NO.

Healing Abutments For Narrow Platform Implant

H:2mm300102

H:3mm300103

H:4mm300104

H:5mm300105

Cat. NO.

H

Narrow Healing Abutment Standaed Platform

H:2mm300302

H:3mm300303

H:5mm300305

H:7mm300307

Cat. NO.

Wide Healing Abutment

Ø 4.5300500

Cat. NO.

Ø 3.5300800

Narrow Temporary Abutment

Hand-tighten (10-15Ncm)utilizing.0.50” (1.25mm) Hex Driver

K2S K2L Hand Driver

L : 09800912

L : 16801612

300202Tissue Measuring Post

Page 21: S2 Internal Hex Implant

16

The Plastic sleeve set available in 3 hardness levels, is connected

by a “click” to the abutment

Peek Temporary AbutmentFor fabrication of cement-or screw-retained provisional retorations ( up to 30days).made from Polymer with high performance, biocompatible thermoplastic designd for medical device application. The peek is an ideal substance for medical use in genraland dental use in particularpackaged with Abutment Screw. Final Torqe:30Ncm

Hard315001

Standard315002

Soft315003

Peek Temporary Angular Abutment 25°

PTA 25°-H:1314251

PTA 25°-H:2314252

PTA 25°-H:3314253

H:1mm310701

H:2mm310702

H:3mm310703

Cat. NO.

Peek Temporary Angular Abutment 15°

PTA 15°-H:1314151

PTA 15°-H:2314152

PTA 15°-H:3314153Cat.

NO.

Peek Temorary Straight Abutment

Temporary Abutment A temporary non-hex abutment for immediate loading, made of Titanium

LS:1mm300801

LS:2mm300802

LS:3mm300803

LS:4mm300804

LS:5mm300805

Cat. NO.

H

packaged with Abutment Screw.

Page 22: S2 Internal Hex Implant

17

Straight Antomic Plastic Sleeve

Plastic structure for casting Available with two options:with or without a external hex that need to go in the internal Hex of the implant. They are without internal threading.The sleeve without the hexagon can be use for multi-implant tasks. The sleeve with the External hex is planned to manufacture a structure on set a crown or bridge that fits onto the abutment or just single implant.

Plastic Sleeve

With Hex310215

No Hex310115

H:9mm310509

Cat. NO.

Packaged with Abutment Screw

H:1mm 310701

H:2mm310702

H:3mm310703

Cat. NO.

To close the Plastic Sleeve use Final Torqe :15Ncm

Angular Antomic Plastic Sleeve 25°

25° - H:1mm 314251

25° - H:2mm 314252

25° - H:3mm314253

Cat. NO.

H:15

H

Angular Antomic Plastic Sleeve 15°

15° - H:1mm 314151

15° - H:2mm 314152

15° - H:3mm 314153

Cat. NO.

H:Restorative Products

H

Height bucc mm 1, 2, 3

Page 23: S2 Internal Hex Implant

18To close the Abutment use Final Torqe :30Ncm

Rest

orati

ve P

rodu

cts

Non-Hex AbutmentThe use of non hex Abutment is for connecting two implants or more by using a permanent rod. The threaded type abutment has neither screw nor hex Can be use in permanent and final restoration. Use the Hand Driver-tighten with the 1.25mm- 050” Hex Driver.Made of Titanium Grade 5

Straight Abutment

L:13mm401313

L:9mm401309

Non-Hex Abutment With Upper HexNon-Hex Abutment

L:13mm400313

L:9mm400309

Cat. NO.

Straight Abutment for Narrow Platform

H:1mm400101

H:2mm400102

H:3mm400103

Cat. NO.

H:

L:Vertical height

Height bucc mm 1, 2, 3

Page 24: S2 Internal Hex Implant

19For more info please refer to WWW.dentalis.us

Straight Abutment

Restorative Products

To close the Abutment use Final Torqe :30Ncm

Straight Abutment Narrow Ø 3.5 mm

L:5mm400405

L:7mm400407

L:9mm400409

Cat. NO.

L

Cat. NO.

Straight Abutment Regular Ø 4.5 mm

H:1.5-L:9mm400509

H:1.5-L:12mm400512

H:1.5-L:15mm400515

L

H

Straight Abutment Wide

400609Cat. NO.

Straight Abutment for Emerged Profile

400610

Straight Abutment With Shoulder

TiN Coated [Ti-6Al-4V]

400801

H:9mm

L:9mm

H

Esthetic Straight Abutment

H:1mm400701

H:2mm400702

H:3mm400703

Cat. NO.

Page 25: S2 Internal Hex Implant

20

Zirconium Anatomic AbutmentDesign for Ideal aesthetic solutions with Strong mechanical force. The shape of the anatomic abutment is planned also to reduce the technician’s working time. Made of Composed of 99.8% Zirconiumthat assists in achieving a strong and stable product.

K2S K2L

Hand Driver

To c

lose

the

Abut

men

t use

Fin

al To

rqe

:30N

cm

packaged with Abutment Screw.

Some products may not be available in all markets Please contact your local Dentalis Office for current product assortment and availabilty

Zirconuim Anatomic Abutment

H: 1mm L:9mm400901

H: 2mm,L:9mm400902

H: 3mm,L:9mm400903

Cat. NO.

Zirconuim Anatomic Angular Abutment 15°

15° - H :1415151

15° - H :2415152

15° - H :3415153

Cat. NO.

Zirconuim Anatomic Angular Abutment 25°

25°- H :1415251

25°- H :2415252

25°- H :3415253

Cat. NO.

L

H

Rest

orati

ve P

rodu

cts

H:Height bucc mm 1, 2, 3

Page 26: S2 Internal Hex Implant

21

Angled Abutment 15° for D2 Implant

412150 1-72 UNF700027

Cat. NO.

To close the Abutment use Final Torqe :30Ncm

Angled Abutment

Restorative Products

Angled Abutment 15° with Shoulder for Narrow Platform

H:1mm411151

H:2mm411152

H:3mm411153

Cat. NO.

L:9H

M 1.4700023

Angled Abutment Standard platform

10° 413101

15° 413150

15° 413151

25° 413259

30° 413309

35° 413359

Cat. NO.

Anatomic Angular Abutment 15°

Cat. No.

15° - H:1mm414151

15° - H:2mm414152

15° - H:3mm414153

Anatomic Angular Abutment 25°

25°- H:1mm414251

25°- H:2mm414252

25°- H:3mm414253

Page 27: S2 Internal Hex Implant

22For more info please refer to WWW.dentalis.us

AAA is short name, This abutment is design with two hex in the upper and bottom, A Plastic casting sleeve can be attached to the upper hex.The plastic sleeve are available with or without an internal hex that fitto the upper External hex of the abutment. This abutment can be suitable for single implant restoration, a screwretained bridge, and raising the height for performing various procedures, e.g., overdentures, bridges, bars and removabledentures.

Available in four heights: 1, 2, 3 and 4 mm.Made of Titanium Grade 5.

Cat. No.

With Hex501101

Without Hex501102

Plastic Casting Sleeve

Anti rotation Aesthetic Abutment

Rest

orati

ve P

rodu

cts

K2S K2L Hand Driver

L : 09800912

L : 16801612

H:1mm501101

H:2mm501102

H:3mm501103

H:4mm501104

Cat. No.

H

300201 300202 300203 300204Cat. No.

Page 28: S2 Internal Hex Implant

23

Restorative Products

To close the Abutment use Final Torqe :30Ncm

Straight adaptor A especially design to facilitate the installation of the overdenture system on nonparallel implants, this type of adaptor has an upper cone that can solve the lack of parallelism.The impression-taking is performed over the installed adaptorsThe overdentnure system is screwed to the cone.

Available in different heights

Made of Titanium Alloy [Ti-6Al-4V]

H:1mm502001

H:2mm502002

H:3mm502003

H:4mm502004

H:5mm502005

Cat. NO.

H

With Hex501101

Without Hex501102

L:3mm300203

Cat. NO.

Plastic Casting Sleeve Implant Analog for Narrow Platform

600013

Multi Unit Angular Adaptor

17° H:1.5 503171

30° H:1.5 503301

Cat. NO.

Page 29: S2 Internal Hex Implant

24

For m

ore

info

ple

ase

refe

r to

WW

W.d

enta

lis.u

sa

To close the Abutment use Final Torqe :30Ncm

The Ball Attachment abutment is use to supported implant retained overdentures. This type of abutment can connects a detachable prosthesis to an implant with theMetal Cap that is on the overdenture. It can provide solid stabilization, retention of the overdenture and tissue-supported with easy fast and reliable way. They are recommended for relatively parallel implants. The Ball Attachment abutments come with a Metal cap and silicon cap.Three 3 types of Silicon caps that are available in three level of hardness, 1-3, from the softest to the hardest. Ball Abutment may be use as indirect transfer impression.Ball Abutment Analogs on facing page are used for the production of a working cast.

The Ball Attachment It made of Titanium Grade 5. The Metal cap is made of stainless steel.

Ball Attachment Abutment

Ove

rden

ture

Ball Attachment for Nerrow Platform Ø 3mm-Code BAN

H:1mm451021

H:2mm451022

H:3mm451023

H:4mm451024

Cat. No.

H

Silicon Cap

Hard-SCH461001

Regular-SCR300102

Sofet-SCS461003 460000

Cat. No.

Metal Cup Protective Disk

300101

BAR-Ball Attachment for Regular platform Ø 3.5 mm

H:1mm452041

H:2mm452042

H:3mm452043

H:4mm452044

H:5mm452045

H:6mm452046

H:7mm452047

H:8mm452048

Cat. No.

H

Ball Attachment Analogs

600013Cat. No.

Used to represent the Ball Abutment Implant assembly in the working cast.Only used in conjunction with Ball Attachment Abutment

K2S K2L Hand Driver

L : 09800912

L : 16801612

Page 30: S2 Internal Hex Implant

25

Overdenture

Page 31: S2 Internal Hex Implant

26

Ove

rden

ture

D-Loc AbutmentDentalis Locator Attachments is intended for use with partial dentures or full overdentures with more than two implants. This attachment abutment type can increases the available opportunities for removable implant prosthetics, through it’s low vertical height profile, range of divergence, dual retention, and self-aligning ability.

This type of properties makes the Locator easy for patients to use, easily seat the overdenture without attaining accurate alignment of the attachment components. It is even possible to use them on implants with a divergence of up to 40º degrees. It also offers three options for the fabrication of a resilient attachment on an implant-supported cast alloy or milled titanium bar.

H:4mm470004

H:5mm470005

H:6mm470006

H:7mm470007

Cat. No.

Silicon Cap set (0-10°) Silicon Cap set (10°-20°)

0-10°-1471001

0-10°-2471002

0-10°-3471003

10°-20°-1471001

10°-20°-2472002

10°-20°-3472003

Cat. No.

473002 473001

Protective Disk Metal Cap

Cat. No.

H:0mm 470000

H:1mm470001

H:2mm470002

H:3mm470003

Cat. No.

H

Page 32: S2 Internal Hex Implant

27

Analog & TransferFor the preparation of laboratory models. Impression Transfer (Impression copy). Hexagon Impression Transfer is made of stainless steel and available for Closed tray - round edges and short screw. Open tray - sharp edges and long screw.The function of an implant level impression is to exactly transfer to a laboratorymodel the position of the implant in relation to natural teeth or other implantsas well as the soft tissue contours. An Implant Level impression can be takes atdifferent stages during treatment and is dependent on Physician /operator preferences:At time of primary surgery – for one stage techniques, or to enable the delivery of a provisional crown at second stage surgery or at the second stage surgery.Impression Transfer closed-tray, transfer impression technique is designed to transfer the implant’s position and the soft tissue profile as well as the hex location, position, Indirect Transfers remain attached to the implants when the closed-tray impression is removed out from the mouth. The transfer hast to retrieve from the implant, mated to the related Implant Analog, and placed into its related impression hole. To fabricate a working cast containing a replica of the implant in the patient’s mouth, the impression is poured in dental stone. Implant-level open-tray, pick-up impression technique: Designed to position the transfer implant’s as well soft tissue profile and hex location, position, Direct Transfers are held firmly within the open-tray impression as it is removed from the mouth. Therefore, the central transfer screw should remove before the impression can be released out from the mouth. This transfer procedure requires a custom tray or modified stock tray with screwaccess holes in the areas occlusal to the implants. The Implant Analog is connected to the transfer embedded within the impression, then the impression is poured in dental stone to fabricate a working cast containing a replica of the implant in the patient’s mouth.Made of stainless steel.

Analog & Transfer

Analog for Narrow Platform

600003Cat. No.

Analog forRegular Platform

600030

Analog forVersatile One Piece

600023

Analog forD2 Implant

600013

Implant Analog for Anti rotation Abutment

600017

Analog for Ball Attachment

600016Cat. No.

Analog for One Piece Anatomic

600023

Implant Analog forStraight adaptor

600018

Page 33: S2 Internal Hex Implant

28

Clip TransferThis one piece product was design to simplified the method of impression it’s intend of use is for places with a limited intermaxillary space for a driver like theback teeth where the lack of space does not allow both the screw and the driverto fit in. Suitable for closed tray method with higher precision and for parallelimplants only. The Clip impression transfer is offering a quick impression with no affixing screw. It is not required to remove or to insert the transfer as it remains in the impression throughout the process.Note: The Clip Transfer doesn’t completely replace the use of standard transfer.

Transfer

Anal

og &

Tra

nsfe

r

Transfer Screw

H:9mm700035

H:15mm700036

Transfer , Impressionfor Regular Platform

H:9mm611209

H:15mm611315

Transfer , Impression for Narrow Platform

H:9mm610103

Cat. No.

Clip Transfer

H:9mm612409

H:15mm612415

Cat. No.

Page 34: S2 Internal Hex Implant

29

Page 35: S2 Internal Hex Implant

30

Surg

ical

Inst

rum

enta

tion

Surgical

Instrumentation

Page 36: S2 Internal Hex Implant

31

Surgical Instrumentation

For more info please refer to W

WW

.dentalis.usa

Dentalis Bio Solutions USA, 9650 E 148th St, Noblesville, 46060, Indiana, USA

Drivers & Tools

K1L - Long Hand Driver to close abutment for Narrow platform Hex Size : 0.9 L : 16 801509 Stainles

steel

K2S - Short Hand Driver to close abutment Hex Size : 1.2 L : 09 810912 Stainless

steel

K2L - Long Hand Driver to close abutment Hex Size : 1.2 L : 16 811612 Stainless

steel

K3S - Short Hand Driver to close abutment Hex Size :1.8 L : 09 820918 Stainless

steel

K3L - Long Hand Driver to close abutment Hex Size : 1.8 L : 16 821618 Stainless

steel

K4S - Short Hex Driver to close abutment with ratchet / Torque . Hex Size :1.2 L : 09 800912 Stainless

steel

K4L - Long Hex Driver to close abutment with ratchet / Torque. Hex Size :1.2 L : 16 801612 Stainless

steel

K5S - Short Hex Driver to close abutment with ratchet / Torque . Hex Size :1.8 L : 09 800918 Stainless

steel

K5L - Long Hex Driver to close abutment with ratchet / Torque . Hex Size :1.8 L : 16 801618 Stainless

steel

K6S - Short Hex Driver to Placing implants with internal Hex . Hex Size : 2.5 L : 09 800925 Stainless

steel

K6L - Long Hex Driver to Placing implants with internal Hex . Hex Size :2.5 L : 16 801625 Stainless

steel

K7 - Retrieving Screw- To release structure from implant. 830001 Stainless

steel

K8 - Short Adaptor inserting the implant using a hand piece 832420 Stainless

steel

K8 - Long Adaptor inserting the implant using a hand piece 832425 Stainless

steel

K9 - Adaptor For prosthetic accessories using a hand piece with torque 831221 Stainless

steel

900004 Stainlesssteel

L

Drill Extension

Page 37: S2 Internal Hex Implant

32

Dent

alis

Bio

Solu

tion

com

plie

s with

ISO

134

85 a

nd C

ounc

il Di

recti

ve 9

3/42

/EEC

Surg

ical

Inst

rum

enta

tion

* Internal irrigation drillis are available *

Ø2.5

6.5m

m

8mm

10m

m

11.5

mm

13m

m

16m

m

3.5mm

Twist drill Twist drill Twist drill Twist drill Twist drill Twist drill Twist drill Twist drill Twist drill

Ø 2.0mm911620

Ø 2.5mm911625

Ø 2.8mm901628

Ø 3.2mm901632

Ø 3.6mm901636

Ø 4.1mm901641

Ø 4.6mm901646

Ø 5.2mm901652

Ø 5.8mm901658

Cat. No.

Drills- External Irrigation

Start Drill

Ø 1.8 mm 900005

Pilot DrillOptional drill to guide succeeding with twist drills, e.g. suitable to facilitate soft bone situation Cat.

No.

Guide DrillTo mark out and create the insertion point penetrating cortex to evaluate bone quantity and quality Cat.

No.900000

Drilling depthThe drilling depth is measured from the drill tip up to the indication line. the additional depth or tip height created by the point of the drill is 0.6 to 2.5 mm, depending on the diameter and type of drill.

2.0 mm 2.5 mm 2.8 mm 3.2 mm 3.6 mm 4.1 mm 4.6 mm 5.2 mm 5.8mm

+0.6 mm +0.7 mm +0.8 mm +0.9 mm +1. mm +1.2 mm +1.35 mm +1.6 mm +2.5mm

Page 38: S2 Internal Hex Implant

33

Surgical Instrumantetion

Long Drills External irrigationTwist drill Twist drill Twist drill Twist drill Twist drill Twist drill

Ø 2 mm902020

Ø 2.4 mm902024

Ø 2.8 mm902028

Ø 3.2 mm902032

Ø 3.6 mm902036

Ø 4.1 mm902041

Cat. No.

Short Drills External irrigation

Twist drill Twist drill Twist drill Twist drill Twist drill Twist drill Twist drill Twist drill

Ø 2 mm901120

Ø 2.5 mm901125

Ø 2.8 mm901128

Ø 3.2 mm901132

Ø 3.6 mm901136

Ø 4.1 mm901141

Ø 4.6 mm901146

Ø 5.2 mm901152

Cat. No.

6.5m

m

8mm

10m

m

11.5

mm

3.5mm

Ø 2.8

Ø 3.2

10m

m

11.5

mm

13m

m

16m

m

18m

m

20m

m

3.5mm

Page 39: S2 Internal Hex Implant

34

Surg

ical

Inst

rum

enta

tion

For m

ore

info

ple

ase

refe

r to

WW

W.d

enta

lis.u

sa

Ceramic Drills The innovative ceramic pilot drills are made high performance mix of Zirconia oxide andAlumina oxide. featuring an excellent cutting performance, reduce vibration, smooth operation, it offer the possibility of working without metal, thus offering biocompatible and antiallergenic operation, Corrosion free, wear resistance can be used between 50 to 100 drills .They are ideal suited for initial preparation of the implant site axis and depth high sharpness and optimal cutting efficiency, requires about half the torque of steel drills.

Ensures smooth and precise surgery Sharp tip blade-easy penetration Large chip spaceslaser marking BiocompatibleFree of metal

Ø 2 mm931620

Ø 2.4 mm931624

Ø 2.8mm931628

Cat. No.

6.5m

m

8mm

10m

m

11.5

mm

13m

m

16m

m

Conical Drill

Conical Drill

Conical Drill

Conical Drill

Conical Drill

Ø 2.4mm921622

Ø 3.6mm921628

Ø 4.2mm921637

Ø 4.7mm921640

Cat. No.

6.5m

m

8mm

10m

m

11.5

mm

13m

m

16m

m

Page 40: S2 Internal Hex Implant

35

Surgical Instrumentation

Counter Sink

Ø 3.75 mm902020

Ø 4.2 mm902024

Ø 4.7 mm902028

Ø 5.5 mm902032

Ø 6 mm902036

Ø 6.5 mm902041

Cat. No.

Purpose:Remove cortical bone at ridge crest to faclitate pressure-free seating of the implant collar*Site Specific Indicated when dense cortical bone is present at the crest* Rounded non-end cutting hubcenters drill in osteotomy*Used folowing the final width increasing drill for each implant

Trephine Bursfor harvesting bone and implant removal

Inner Ø 2mmOuter Ø 3mm

951630

Inner Ø 3mmOuter Ø 4mm

951640

Inner Ø 4mmOuter Ø 5mm

951650

Inner Ø 5mmOuter Ø 6mm

951660Cat. No.

6.5m

m

8mm

10m

m

11.5

mm

13m

m

16m

m

Page 41: S2 Internal Hex Implant

36

Sinus Kit

872028 872832 873236 873643 874348

882028 882832 883236 883643

Surg

ical

Inst

rum

enta

tion

Cat. No.

Straight Osteotomes Kit

2-2.8 Ø872028

2.8-3.2 Ø872832

3.2-3.6 Ø873236

3.6-4.3 Ø873643

4.3-4.8 Ø874348

Angular Osteotomes Kit

2-2.8 Ø882028

2.8-3.2 Ø882832

3.2-3.6 Ø883236

3.6-4.3 Ø883643

4.3-4.8 Ø884348

6.5m

m

8mm

10m

m11

.5m

m13

mm

4mm

Page 42: S2 Internal Hex Implant

37

Surgical Instrumentation

Straight Parallel

Pins(2 per kit )

15° Angled Parallel

Pins(2 per kit )

Parallel Pin KitPurpose:Evaluation of osteotomy position and angleProvided straight or a 15° or 25° angleUsed after Ø 2.0mm Starter Drill and Ø 2.5mm Depth Drill9mm shank for radiographic evaluation of proxmimty to adjacent anatomy Hub diameter is 4.0mm

25° Angled Parallel

Pins(2 per kit )

Tissue Measuring

Post

Professional Implantology ToolsRatchet WrenchRatchet TorqueMallet Handle

Depth Gauge Kit

Ø1.8 Ø2.4 Ø2.8 Ø3.2 Ø3.6 Ø4.1

861821 862421 862821 863221 863621 864121Cat. No.

6.5m

m

8mm

10m

m

11.5

mm

13m

m

Depth Gauge

Tissue Punch Driver

Page 43: S2 Internal Hex Implant

38

Dentalis Bio Solution complies withISO 13485, ISO 14001 and Council Directive 93/42/EEC

Canadian Medical Devices Regulation.

For USA Only: Federal Law restricts this device to sale by or the order of licensed dentist or physician

All products are subject to change without notice.Some products may not be available in all markets

Please contact your local Dentalis Office for current product assortment and availabilty

Page 44: S2 Internal Hex Implant

Dentalis Bio Solutions USA9650 E 148th St

Noblesville, 46060Indiana, USA

Phone: 317-214-7076 For more info please refer to WWW.dentalis.us or to your local distributor