ISO 13655 MEASUREMENT CONDITIONS
What they are and where they apply
![Page 2: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/2.jpg)
ISO STANDARDS FOR THE PRINTING INDUSTRY
ISO 3664:2009• Viewing conditions• D50/2º
ISO 5 Series:2009• Densitometry
ISO 13655:2009• Spectral Measurement and
Colorimetric Computation for Graphic Arts Images
• M-Standards introduced
2
![Page 3: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/3.jpg)
WHY MEASURE?
• Process setup• Process control• Print specification• Spot colour matching• Reporting• Independent reference• Easy to share
Better agreement between visual assessment and measurements
• Process setup• Process control• Print specification• Spot color matching• Reporting• Independent reference• Easy to share
![Page 4: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/4.jpg)
ISO 3664:2009 – VIEWING CONDITIONS
Light source• Relative spectral power distribution must match CIE illuminant D50
• UV energy must meet CIE illuminant D50 (correlates to M1 within ISO 13655)
Two levels of light intensity conditions• P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux
• P2 Practical Appraisal: less critical comparisons e.g. hardcopy to softproof: 500 ± 125 Lux or exact illuminance adjustment of lightbooth to monitor
Further definitions• Homogenity
• Surrounding: neutral gray diffuse surface
• Viewing angle to avoid glare
![Page 5: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/5.jpg)
WHAT IS WRONG IN THIS SCENE?
5
![Page 6: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/6.jpg)
THIS IS MUCH BETTER!
6
![Page 7: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/7.jpg)
PAPER FLUORESCENCE (OBAS)
![Page 8: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/8.jpg)
DIFFERENT LIGHTING CREATES DIFFERENT RESULTS
8
Daylight D
50A –
Tungsten
TL84 –R
etail StoreU
V only
![Page 9: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/9.jpg)
M194
3
-12
M0L* 94
a* 2,5
b* -9
REFLECTANCE OF PAPER WITH OBA
Different UV Content in Light or Measurement Mode -> Different Result
9
0
25
50
75
100
400 500 600 700Wavelength in nm
Ref
lect
ance
in
%
M294
0,5
-4
D50 - old - new - UVCut
![Page 10: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/10.jpg)
M195
-0,5
0
M0L* 95
a* -0,5
b* 0
M295
-0,5
0
400 500 600 700Wavelength in nm
Ref
lect
ance
in
%
D50 - old - new - UVCut
REFLECTANCE OF PAPER WITHOUT OBA
Different UV Content in Light or Measurement Mode -> Same Result
10
0
25
50
75
100
![Page 11: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/11.jpg)
WHAT’S NEW IN MEASUREMENT – ISO 5 SERIES
Density and Colorimetry requirements harmonized• For Graphic Arts all illuminants defined in 13655 allowed
Spectral Calculation methods defined for Status Density
![Page 12: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/12.jpg)
ISO 13655: 2009/2017 – MEASUREMENT CONDITIONS
Specifies spectral measurement conditions for graphic arts• Measurement geometry
• 0°/45° or 45°/0°• Backing
• Black Backing: Matte black substrate visual density 1.5 ± 0.2• White Backing: Matte white substrate w/o OBA,
• 2009: L* between 92 and 96, C* below 3• 2017: C* below 3 and spectral curve defines reflectance (effectively lowering high end of L*)
• Provides a mathematical formula for substrate compensation• Applies to press characterization, pressroom control, proof-print verification
![Page 13: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/13.jpg)
ISO 13655: 2009/2017 – MEASUREMENT CONDITIONS
Specifies spectral measurement conditions for graphic arts• Measurement illumination conditions
• M0: Should be CIE Illuminant A (many legacy spectrophotometers)• undefined UV amount• covers unknown illuminants as well
• M1: CIE Illuminant D50, 1 for paper (OBA) only• Part 1 is D50 match use for all fluorescence (ink, papers, etc)• Part 2 Calculated UV response to emulate UV excitation of OBA‘s (for paper only)
• M2: UV cut• Little energy below 420 nm, continuous illumination above
• M3: Polarization Filter with UV cut equal to M2• Special use cases
M0,M11,M2, M3 M0,M12,M2
![Page 14: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/14.jpg)
M3 – POLARIZATION
Colour Assessment independent of the surface• Polarization reduces reflections caused by the surface reflection or bronzing • On method of density comparison between wet and dry inks.• It also removes UV equivalent to M2.• Is used in ISO 12647 for as an option for density process control.
Attention: There is no viewing condition that matches this measurement condition
![Page 15: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/15.jpg)
M’S THE GRAPHS
![Page 16: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/16.jpg)
WHAT IT REALLY MEANS
Paper brighteners (OBA’s)
![Page 17: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/17.jpg)
EFFECT OF INK COVERAGE
![Page 18: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/18.jpg)
THE RIGHT MEASUREMENT MODE TO HIT THE TARGET
![Page 19: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/19.jpg)
QUICK REVIEW
![Page 20: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/20.jpg)
M0 - INCANDESCENT OR UNDEFINED
![Page 21: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/21.jpg)
M1 - D50 OR SOMETHING LIKE IT
![Page 22: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/22.jpg)
M2 – UV CUT, UV EXCLUDED, UV…
![Page 23: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/23.jpg)
M3 – POLARIZED (AND UV CUT)
![Page 24: ISO 13655 MEASUREMENT CONDITIONS€¦ · • P1 Critical Comparison: e.g. two prints: illuminance 2000 ± 500 Lux • P2 Practical Appraisal: less critical comparisons e.g. hardcopy](https://reader035.vdocument.in/reader035/viewer/2022071507/6127851b3d59ea66ca401e74/html5/thumbnails/24.jpg)
THANK YOU!