jensen rainwater harvesting system (jrwh) · 2020. 5. 29. · oth er s, u nlw ipc f d. a b s ea l...
TRANSCRIPT
PROFILE VIEW
NOT TO SCALE
PLAN VIEW
NOT TO SCALE
PLAN VIEW3
TOP LEFT ISOMETRIC VIEW w/ SECTION
NOT TO SCALE
Rainw
ater H
arvesting Assem
bly.idw
SHEET:
REV:
1 OF 2
4/7/2020
MODIFIED:CREATED:
PART NUMBER: DRAWN BY:
DESCRIPTION:
JENSEN RAINWATER HARVESTING SYSTEM (JRWH)
521 DUNN CIRCLE, SPARKS, NV 89431
www.jensenwaterresources.com
(855) 468-5600
Rainwater Harvesting Assembly
T. Handke
©2018 Jensen Precast - All rights reserved.
All materials appearing as Jensen Precast documents and the like are
proprietary work product and are protected under
U.S. copyright and other laws.
Unless in conjunction with business conducted with Jensen Precast, any
use of Jensen Precast work product without express, written consent is
prohibited, and recipient is prohibited from distributing any and all work
product to non-approved third parties under penalty of civil action.
TITLE SHEET
DISCLAIMERS, INCLUDING BUT NOT LIMITED TO:
1.) All elevations have been provided by others, and have not been verified by Jensen Precast. Contractor to verify all dimensions and elevations
in field prior to installation.
2.) These layout drawings are intended to show overall system design only. All concrete component thicknesses, dimensions, and joint
orientations may vary across Jensen Precast's manufacturing facilities. Contractor to confirm all thicknesses, dimensions, and joint orientations
prior to installation.
3.) System design criteria has been provided to Jensen Precast. Others are responsible for verification that system meets intended application.
4.) Foundation, subgrade, and backfill to be designed by others.
JENSEN RAINWATER HARVESTING SYSTEM (JRWH)
PROFILE VIEW
NOT TO SCALE
PLAN VIEW
NOT TO SCALE
Rainw
ater H
arvesting Assem
bly.idw
INLET
OVERFLOW
POINT OF CONNECTION
POINT OF CONNECTION
OVERFLOW
FINISHED GRADE
INLET
REDUNDANT OFF
PUMP OFF
PUMP ON
SHEET:
REV:
2 OF 2
4/7/2020
MODIFIED:CREATED:
PART NUMBER: DRAWN BY:
DESCRIPTION:
JENSEN RAINWATER HARVESTING SYSTEM (JRWH)
521 DUNN CIRCLE, SPARKS, NV 89431
www.jensenwaterresources.com
(855) 468-5600
Rainwater Harvesting Assembly
T. Handke
©2018 Jensen Precast - All rights reserved.
All materials appearing as Jensen Precast documents and the like are
proprietary work product and are protected under
U.S. copyright and other laws.
Unless in conjunction with business conducted with Jensen Precast, any
use of Jensen Precast work product without express, written consent is
prohibited, and recipient is prohibited from distributing any and all work
product to non-approved third parties under penalty of civil action.
PLAN & PROFILE
DISCLAIMERS, INCLUDING BUT NOT LIMITED TO:
1.) All elevations have been provided by others, and have not been verified by Jensen Precast. Contractor to verify all dimensions and elevations
in field prior to installation.
2.) These layout drawings are intended to show overall system design only. All concrete component thicknesses, dimensions, and joint
orientations may vary across Jensen Precast's manufacturing facilities. Contractor to confirm all thicknesses, dimensions, and joint orientations
prior to installation.
3.) System design criteria has been provided to Jensen Precast. Others are responsible for verification that system meets intended application.
4.) Foundation, subgrade, and backfill to be designed by others.
QTY COMPONENT DESCRIPTION
1
4-IN (100-MM) TURBINE EFFLUENT PUMP
3 FLOAT SWITCH W/ SLIDING COLLAR
1
DISCHARGE PLUMBING ASSEMBLY (TYP. 1" - 2" DIA.)
1
XX" DIA. INLET PIPE STUB (INSTALLED BY OTHERS)
AS REQ'D. 30" DIA. GRADE RINGS
2
30" DIA. CAST IRON RING & COVER (TYP.)
MATERIALS LIST - PROVIDED WITH UNIT :
ØXX" INLET PIPE
JENSEN RAINWATER HARVESTING SYSTEM (JRWH)
INLINE CISTERN w/ TYPICAL RAINWATER HARVESTING PUMP PACKAGE
TANK SIZES
AVAILABLE
500 GAL
750 GAL
1000 GAL
1200 GAL
1500 GAL
2000 GAL
2500 GAL
3000 GAL
TANK DESIGNED FOR H-20 TRAFFIC WHEEL LOAD
WITH DRY SOIL CONDITIONS (WATER TABLE
BELOW TANK). 3' OF EARTH COVER MAXIMUM.
SYSTEM SHOWN IS LEVEL CONTROLLED; TIMED OR DEMAND
CONTROLLED OPTIONS ARE AVAILABLE
ALTERNATE CISTERN & PUMPING CONFIGURATIONS ARE AVAILABLE
CONTACT JENSEN WATER RESOURCES FOR DESIGN ASSISTANCE
(855) 468-5600 | www.jensenwaterresources.com
TYPICAL RWH PUMP PACKAGE COMPONENTS:
LOW FLOW SUBMERSIBLE PUMP WITH POWER CABLE
• PVC DISCHARGE ASSEMBLY WITH CHECK VALVE & UNION
• MECHANICAL FLOAT ASSEMBLY
OPTIONAL CONTROLS FEATURES INCLUDE BUT ARE NOT LIMITED TO:
• AUDIBLE AND VISIBLE ALARMS
• DATA COMMUNICATION
• VALVE SWITCHING FOR ALTERNATE SUPPLY UNDER PROGRAMMABLE CONDITIONS
MATERIALS NOTES:
CISTERN PIPE OPENINGS PROVIDED BY JENSEN PRECAST. PIPE AND CONDUIT
OPENINGS THROUGH GRADE RINGS/RISERS TO BE CORED IN FIELD BY OTHERS.
ALL PIPE MATERIAL NOT SHOWN ON THIS DETAIL SHALL BE PROVIDED BY
OTHERS, UNLESS OTHERWISE SPECIFIED. ALL PIPE PENETRATIONS TO BE
SEALED IN FIELD BY OTHERS, UNLESS OTHERWISE SPECIFIED.
CISTERN INSTALLATION (INCLUDING BUT NOT LIMITED TO: TANK SETTING,
PLUMBING CONNECTIONS, SUBGRADE AND BACKFILL, ETC.) SHALL BE
PERFORMED BY CONTRACTOR.
BURY DEPTH
30"Ø CAST IRON
RING & COVER (TYP.)
JENSEN RAINWATER
HARVESTING (RWH)
CISTERN
PVC DISCHARGE ASSEMBLY
w/ CHECK VALVE & UNION
PUMP HOUSING
FLOAT ASSEMBLY
PUMP INTAKE
SUBMERSIBLE PUMP
30"Ø CAST IRON
RING & COVER (TYP.)
30"Ø GRADE RINGS
AVAILABLE IN 3", 6" &
12" HEIGHTS (TYP.)
PUMP
SUBMERGENCE
SYSTEM CHARACTERISTICS
END USE OR APPLICATION TYPE
REQUIRED FLOW RATE (GPM)
REQUIRED PRESSURE (PSI)
POINT OF CONNECTION ELEVATION (FT)
CONTROL PANEL & CONDUIT
INSTALLATION BY OTHERS
Project Name: Date:
Project Location: Target Construction Date: City State
Your Name: Email:
Company Name: Phone:
○ PROJECT TYPE: ○ HARVESTED WATER ‐ END USE: (Check all that apply)
Residential Landscape Irrigation System (Sprinkler)
Commercial Landscape Irrigation System (Drip)
Public Works Gray Water (Toilet Supply)
Other: Fire Water
Potable Water Source
○ RWH CISTERN SELECTION: Other:
AREA/FOOTPRINT CONSTRAINTS:
Maximum Length: (ft) ○ RWH PUMPING DESIGN PARAMETERS:
Maximum Width: (ft) Simplex Duplex
Maximum Height: (ft) DEMAND‐SIDE DISTRIBUTION CHARACTERISTICS
ACTIVE STORAGE REQUIREMENTS: Required Pressure: (lb/in2)
Required Storage Volume: (gallons) Required Flowrate: (ft3/s)
Required Freeboard: (ft) Maximum Discharge Pipe Elevation: (ft)
RWH CISTERN ELEVATIONS: Point of Connection Elevation: (ft)
Finished Grade/Rim Elevation: (ft)
○ RWH PIPE DATA:
SYSTEM COMPONENTS AND ELEVATIONS:
Overflow Pipe Size: " (Inside Dimension) Pipe Material: Invert Elevation: (ft)
Inlet Pipe Size: " (Inside Dimension) Pipe Material: Invert Elevation: (ft)
Pump Discharge Pipe Size: " (Inside Dimension) Pipe Material:
Additional Pipe connections to cistern (if applicable):
Pipe Size: " (Inside Dimension) Pipe Material: Invert Elevation: (ft)
Pipe Size: " (Inside Dimension) Pipe Material: Invert Elevation: (ft)
Pipe Size: " (Inside Dimension) Pipe Material: Invert Elevation: (ft)
○ CUSTOMER COMMENTS / ADDITIONAL REQUIREMENTS:
SITE SPECIFIC QUESTIONNAIRE
JENSEN RAINWATER HARVESTING SYSTEM (JRWH)
Description
Description
Description
For design assistance related to the sizing and selection of rainwater harvesting system components, please contact
JENSEN WATER RESOURCES
(855) 468‐5600 ○ [email protected] ○ www.jensenwaterresources.com
( )