VITOLIGNO 300-P Type VL3B Boiler for wood pellets VIESMANN Datasheet For part no. and prices: see pricelist VITOLIGNO 300-P Pellet boiler 4 to 48 kW File in: Vitotec folder, register 12 5822 413 GB 8/2007

Upload: lynhi

Post on 15-Sep-2018

225 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

VITOLIGNO 300-P Type VL3B

Boiler for wood pellets

VIESMANN

DatasheetFor part no. and prices: see pricelist

VITOLIGNO 300-PPellet boiler4 to 48 kW

Filein:

Vitotecfolder,register12

5822 413 GB 8/2007

Page 2: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

The Vitoligno 300-P pellet boiler with three-pass principle fromViessmann sets new standards for heating with wood pelletswhere convenience, efficiency and safety are concerned. Devel-oped and built by Viessmann.Wide modulation range: The Vitoligno 300-P makes its casethrough efficiency and economical operation. For low energyhouses or buildings with a higher energy demand: With an outputrange from 4 to 48 kW and a high modulation ratio (1:3), it offers atailor-made solution for any heat demand and every aspiration.High efficiency: With its efficiency of up to 95% and its low fluegas temperatures from 125 to 135 °C, the Vitoligno 300-P com-mands one of the leading positions in the market. Combustion isconstantly monitored by a Lambda probe and a temperature sen-sor. This safeguards the permanently high efficiency and insensi-tivity to fluctuating pellet qualities. The large water content of theVitoligno 300-P makes thermal process protection superfluous.

Efficient partial load operation with Variopass: The three-passprinciple reduces the flow velocity of the hot gas in the first pass.In the second pass it directs the floating particles into the ash boxand expels almost dust free hot gas through the third pass.The new Variopass design principle matches the heating surfaceto the current operating state. A special mechanism automaticallyreduces the heating surfaces of the second and third hot gas fluein partial load operation, thereby assuring a very high utilisationlevel in all operating phases.Return temperature raising facility: The new Vitoligno 300-P oper-ates with low return temperatures. Reliability and a long servicelife are assured by the internal return temperature raising facility.An external return temperature raising facility is only required inheating systems with heating water buffer cylinder.

5822413GB

2 VIESMANN VITOLIGNO 300-P

Product information

Page 3: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

A Highly effective thermal insulationB Secondary heating surfacesC Automatic cleaning of the heating surfacesD Variopass; flue gas temperature regulated subject to outputE Internal return temperature raising facilityF Vitotronic 300G Integral ash boxH Combustion chamber made from high temperature-resistant

ceramicsK Tipping grateL Drop chuteM Connection flange for the pellet supply

& Fully automatic pellet boiler& Continuous matching of the output to the heat demand; subjectto the operating state down to 30 %

& Variopass design for matching the heating surfaces to the oper-ating conditions

& Fully automatic pellet charging (with appropriate accessoriesfrom various storage systems)

& Pellet hopper with large capacity (vacuum system version)thanks to optimum space utilisation

& Interval ignition& Large ash box requires emptying only twice per annum (subjectto operating mode and fuel quality)

& Long service life and high operational reliability through integralreturn temperature raising facility

& Automatic heat exchanger cleaning and combustion chamberash removal (no motor required for ash removal)

& Minimum emissions through three-pass design& Easy operation through digital control unit with menu-guidedplain text prompts

& Compact dimensions for easier handling& Public subsidies [check local regulations]: All guidelines relatingto subsidies are met [in Germany]

5822413GB

VITOLIGNO 300-P VIESMANN 3

Benefits at a glance

Page 4: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

Specification

Rated output range kW 4 to 12 6 to 18 8 to 24 11 to 32 13 to 40 16 to 48Flow temperature– permissible °C 95 95 95 95 95 95– maximum °C 75 75 75 75 75 75– minimum °C 60 60 60 60 60 60Minimum return tempera-ture

°C 35 35 35 35 35 35

Permissible operatingpressureBoiler bar 3 3 3 3 3 3CE designation CEin accordance with theMachinery DirectiveBoiler class toDIN EN 303-5

3 3 3 3 3 3

Total dimensionsTotal length k mm 1065 1065 1065 1185 1185 1185Total width e mm 685 685 685 785 785 785Total height b mm 1485 1485 1485 1710 1710 1710– Handling dimensions incl.shipping protection

mm 915 x765 x 1630

915 x765 x 1630

915 x765 x 1630

1014 x865 x 1861

1014 x865 x 1861

1014 x865 x 1861

– Handling dimensionsexcl. shipping protection

mm 797 x629 x 1407

797 x629 x 1407

797 x629 x 1407

899 x730 x 1631

899 x730 x 1631

899 x730 x 1631

Total weight– Boiler incl. thermal insula-tion and pellet hopper

kg 466 466 466 602 602 602

– Boiler incl. thermal insula-tion and connection unit

375 375 375 502 502 502

Transport weight– Boiler excl. shipping pro-tection and pellet hopper

kg 303 303 303 414 414 414

Max. power consumption– during ignition W 350 350 350 350 350 350– during heating operation W 120 130 130 140 140 140– Pellet supply

Vacuum system W 1960 1960 1960 1960 1960 1960Auger system W 120 120 120 120 120 120

Content boiler water l 100 100 100 180 180 180Boiler connectionsBoiler flow and return plus G 1½" 1½" 1½" 1½" 1½" 1½"Safety connection (safetyvalve)Safety return and drain R ¾" ¾" ¾" ¾" ¾" ¾"Flue gas*1average temperature (gross)*2)– at upper output °C 125 125 125 125 125 125– at partial load (33% of theupper output)

°C 70 70 70 70 70 70

Mass flow rate– at upper output kg/h 20 27 33 49 61 73– at partial load (33% of theupper output)

kg/h 9 10 12 17 22 30

CO2 content in the flue gas % 12 12 12 12 12 12Flue outlet 7 mm 130 130 130 150 150 150Required draught Pa 5 5 5 5 5 5

mbar 0.05 0.05 0.05 0.05 0.05 0.05Boiler efficiency– at full load % 94.5 94.4 94.7 94.3 94.6 94.2– at partial load % 95.3 95.7 96.6 95.4 95.3 95.8

5822413GB

4 VIESMANN VITOLIGNO 300-P

*1Values for calculating the size of the flue system to DIN EN 13384, based on 12.0% CO2.*2Actual flue gas temperature as average gross value per EN 304 at 20 °C combustion air temperature.

Specification

Page 5: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

A Pellet hopper for pellet supply via vacuum systemB Connection unit for pellet supply via augerAGA Flue gas connectionE R ¾" drain and diaphragm expansion vessel

KR Boiler return G 1½"KV Boiler flow G 1½"SA Safety connection (safety valve) G 1½"

Rated output range kW 4 to 126 to 188 to 24

11 to 3213 to 4016 to 48

a mm 1590 1815b mm 1485 1710c mm 1414 1639d mm 676 777e mm 685 785f mm 452 452g mm 1458 1683h mm 1600 1825k mm 1065 1185l mm 1323 1547m mm 828 930n mm 1016 1241o mm 520 618p mm 218 232

Dim. a: Total height with the control unit in operating positionHeights: Details incl. adjustable feet height 30 mm

5822413GB

VITOLIGNO 300-P VIESMANN 5

Specification (cont.)

Page 6: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

Positioning

Clearances for pellet supply via vacuum system

A BoilerB Pellet hopper

Clearances for pellet supply via auger

A BoilerB Connection unit auger

Rated output range kW 4 to 12 6 to 18 8 to 24 11 to 32 13 to 40 16 to 48Dimension a mm min. 700 min. 800Dimension b min. 1500 min. 1700

NoteThe minimum clearance between the wall and the r.h. side of theboiler is required for maintenance purposes.

Positioning& Avoid air contamination through halogenated hydrocarbons (e.g. as in sprays, paints, solvents and cleaning agents)

& Avoid very dusty conditions& Avoid high levels of humidity& Protect against frost and ensure good ventilation

Otherwise, the system may suffer faults and damage.In rooms where air contamination through halogenated hydro-carbons may occur, such as hairdressing salons, printing shops,chemical cleaners, laboratories etc., install the boiler only if ade-quate measures can be taken to provide a supply of uncontami-nated combustion air.If in doubt, please contact us.If these instructions are not observed, any consequential lossesdirectly related to any of these causes are excluded from our war-ranty.

5822413GB

6 VIESMANN VITOLIGNO 300-P

Specification (cont.)

Page 7: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

Pressure drop on the heating water side

A Rated output ranges: 4-12, 6-18 and 8-24 kWB Rated output ranges: 11-32, 13-40 and 16-48 kW

Specification, Vitotronic 300, type FW1

Design and function

Modular designThe control unit is integrated into the Vitoligno 300-P. It comprisesa standard unit, electronic modules and a programming unit.

Standard unit:& Standby switch& Emissions test switch& Optolink laptop interface& High limit safety cut-outDIN STB 116904

& Operation and fault displays& Wiring chamber– Connection of external equipment via a system plug– Connection of three-phase consumers via additional contac-tors

Programming unit:& Push buttons& Illuminated display with plain text prompts& Digital time switch& Adjustment and display of temperatures and codes& Fault message display

Functions& Weather-compensated control of the boiler water and/or flowtemperature

& Electronic maximum and minimum temperature limit& Control of two heating circuits with mixer or one heating circuitwith mixer and one solar circuit

& Option to regulate a heating water buffer cylinder& Demand-dependent heating circuit pump and burner OFF con-trol

& Adjustment of a variable heating limit5822413GB

VITOLIGNO 300-P VIESMANN 7

Specification (cont.)

Page 8: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

& Anti-seizing pump protection& Integral diagnostic system& Service display& Adaptive cylinder temperature control unit with priority control(heating circuit pumps OFF, mixer closed)

& Auxiliary function for DHW heating (short-term heating to ahigher temperature)

& Screed drying, for underfloor heating systems& Control of a solar circuit as alternative to the second mixer cir-cuit.

The requirements of DIN EN 12831 for the heating load calcula-tion are met. To reduce the heat-up load, the reduced room tem-perature will be raised in case of low outside temperatures. Theflow temperature will be raised for a limited time to reduce theheat-up time after a setback period.According to the Energy Savings Order [Germany], the tempera-ture in each room must be individually controlled, e.g. throughthermostatic radiator valves.

Control characteristics& Boiler control unit:PI characteristics with modulating operation

& Heating circuit control unit:PI characteristics with three-point output

& Thermostat for limiting the max. boiler water temperature:85 °C

& Adjusting the high limit safety cut-out:95 °C

& Heating curve setting range:– Slope: 0.2 to 3.5– Level: -13 to 40 K– Max. limit: 20 to 130 °C– Min. limit: 1 to 127 °C– Differential temperature for a heating circuit with mixer: 0 to40 K

& Range of the set DHW temperature10 to 60 °C, may be changed to 10 to 75 °C

Boiler coding cardFor matching to the boiler (integrated).

Time switchDigital time switch& Individual and 7-day program& Automatic summer/winter time changeover& Automatic function for DHW heating and DHW circulation pump& Time, day and standard switching times for central heating,DHW heating and the DHW circulation pump are factory-set

& Switching times are individually programmable, i.e. up to fourswitching periods per day

Shortest switching interval: 10 minutesPower backup: 14 days

Setting heating programsThe heating system frost protection (see frost protection function)applies to all heating programs.The heating programs are selected via menus. The following heat-ing programs can be selected:& Heating and DHW& DHW only& Standby modeExternal heating program changeover

Summer mode("DHW only")The burner starts only when the DHW cylinder needs reheating(controlled by the cylinder thermostat).The respective lower boiler water temperature of each boiler ismaintained.

Frost protection& The frost protection function will be started when the outsidetemperature drops below approx. +1 °C.With the frost protection activated, the heating circuit pumps areswitched ON and the boiler water is heated to the set value forreduced mode, but is held at least to the lower temperature limitof approx. 20 °C (the lower temperature is maintained for boilerswith lower temperature limit).

& The frost protection function will be switched OFF, when the out-side temperature exceeds approx. +3 °C, i.e. the heating circuitpump and burner will be switched OFF.

Adjusting the heating curves (slope and level)The Vitotronic 300, type FW1 controls the boiler water tempera-ture and the flow temperature of the heating circuits with mixer inweather-compensated mode. The boiler water temperature isautomatically boosted by between 0 and 40 K higher than the cur-rently required set flow temperature (delivered condition 8 K).The flow temperature required to reach a specific room tempera-ture depends on the heating system and the thermal insulation ofthe building to be heated.Adjusting both heating curves matches the boiler water tempera-ture and the flow temperature to these operating conditions.The upper boiler water temperature is limited by the electronictemperature limiter and the electronic maximum temperature limit.

Boiler water temperature sensor

SpecificationLead length 1.6 m, fully wiredProtection IP 32 to EN 60529; safe-

guard through appropriatedesign and installation

Permissible ambient temperature– during operation 0 to +130 °C– during storage and transport -20 to +70 °C

5822413GB

8 VIESMANN VITOLIGNO 300-P

Specification, Vitotronic 300, type FW1 (cont.)

Page 9: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

Outside temperature sensorInstallation location:& North or north-western wall of the building& 2 to 2.5 m above the ground, for multi-storey buildings in theupper half of the second floor

Connection:& 2-core lead, length up to 35 m with a cross-section of 1.5 mm2

(copper).& Never route this lead immediately next to 230/400 V cables

SpecificationProtection IP 43 to EN 60529;

safeguard through appro-priate design and instal-lation

Permissible ambient temperature dur-ing operation, storage and transport -40 to +70 °C

Cylinder temperature sensor

SpecificationLead length 5.8 m, fully wiredProtection IP 32 to EN 60529; safe-

guard through appropriatedesign and installation

Permissible ambient temperature– during operation 0 to +90 °C– during storage and transport -20 to +70 °C

Specification, Vitotronic 300, type FW1

Rated voltage 230 V~Rated frequency 50 HzRated current 6 APower consumption 142 W (arithmetical

average)Protection class IProtection IP 20 D to EN 60529;

safeguard throughappropriate designand installation

Function Type 1B to EN 60 730-1

Permissible ambient temperature– during operation 0 to +40 °C

Installation in livingspaces or boiler rooms(standard ambientconditions)

– during storage and transport -20 to +65 °CRated capacity of the relay outputssÖ Heating circuit pumps 4(2) A, 230 V~*1sA Cylinder primary pump 4(2) A, 230 V~*1sK DHW circulation pump 4(2) A, 230 V~*1gS Mixer motor 0.2(0.1) A, 230 V~*1gÖ Central fault message 4(2) A, 230 V~sF Solar circuit pump 4(2) A 0.230 V~sL Boiler circuit pump 0.75 A, 230 V~Total max. 6 A, 230 V~

Accessories for the Vitotronic 300, type FW1

Extension kit for a heating circuit with mixer

Part no. 7267 627Components:& Mixer motor with connecting cable& Plug for the heating circuit pump and flow temperature sensor(contact temperature sensor)

The mixer motor is mounted directly onto the Viessmann mixerDN 20 to 50 and R ½" to 1¼".

5822413GB

VITOLIGNO 300-P VIESMANN 9

*1Total max. 4 A, 230 V~.

Specification, Vitotronic 300, type FW1 (cont.)

Page 10: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

Mixer motor

SpecificationCable length 4.2 m, fully wiredRated voltage 230 V~Rated frequency 50 HzPower consumption 4 WProtection class IIProtection IP 42 to EN 60529; safe-

guard through appropri-ate design andinstallation

Permissible ambient temperature– during operation 0 to +40 °C– during storage and transport -20 to +65 °C

Torque 3 NmRuntime for 90 °∢ 120 s

Flow temperature sensor (contact temperature sensor)

SpecificationLead length 5.8 m, fully wiredProtection IP 32 to EN 60529; safe-

guard through appropri-ate design andinstallation

Permissible ambient temperature– during operation 0 to +120 °C– during storage and transport -20 to +70 °C

Mixer motor for flanged mixers

& Part no. 9522 487DN 40 and 50, without system plug and connecting cable

& Part no. Z004344DN 65 to 100, without system plug and connecting cable

For specification, see the "Mixer and mixer motors" datasheet inthis folder.

Contact temperature sensor

Part no. 7267 633For capturing the flow and return temperature.

Specification

Lead length 5.8 m, fully wiredProtection IP 32 to EN 60529; safe-

guard through appropri-ate design andinstallation

Permissible ambient temperature– during operation 0 to +120 °C– during storage and transport -20 to +70 °C

5822413GB

10 VIESMANN VITOLIGNO 300-P

Accessories for the Vitotronic 300, type FW1 (cont.)

Page 11: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

Immersion temperature sensor

With sensor well R½" x 100 mmPart no. 7267 632For capturing the flow and return temperature.

Specification

Lead length 3.8 m, fully wiredProtection IP 32 to EN 60529; safe-

guard through appropri-ate design andinstallation

Permissible ambient temperature– during operation 0 to +90 °C– during storage and transport -20 to +70 °C

Plugs for sensors

Part no. 7268 274(3 pce.)

Immersion thermostat

Part no. 7151 728May be used as a maximum temperature limiter for underfloorheating systems.The temperature limiter is installed into the heating flow andswitches the heating circuit pump OFF in case of excessive flowtemperature.

Specification

Cable length 4.2 m, fully wiredSetting range 30 to 80 °CSwitching differential max. 11 KBreaking capacity 6(1.5) A 250 V~Setting scale inside the casingStainless steel sensor well R ½" x 200 mmDIN reg. no. DIN TR 77703

orDIN TR 96803orDIN TR 110302

Contact thermostat

Part no. 7151 729May be used as a maximum temperature limiter for underfloorheating systems (only in conjunction with metallic pipes).The temperature limiter is installed into the heating flow andswitches the heating circuit pump OFF in case of excessive flowtemperature.

5822413GB

VITOLIGNO 300-P VIESMANN 11

Accessories for the Vitotronic 300, type FW1 (cont.)

Page 12: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

Specification

Cable length 4.2 m, fully wiredSetting range 30 to 80 °CSwitching differential max. 14 KBreaking capacity 6(1.5) A 250V~Setting scale inside the casing

DIN reg. no. DIN TR 77703orDIN TR 96803orDIN TR 110302

Solar components

Part no. 7267 700comprising:

Collector temperature sensorwith Rast 5 system plug (supplied separately) for connectioninside the device.On-site extension of the connecting cable:& 2-core lead, length up to 60 m with a cross-section of 1.5 mm2

(copper)& Never route this lead immediately next to 230/400 V cables

Lead length 2.5 mProtection IP 32 to EN 60529; safe-

guard through appropri-ate design andinstallation

Sensor type Pt500Permissible ambient temperature– during operation -20 to +180 °C– during storage and transport -20 to +70 °C

Cylinder temperature sensorwith Rast 5 system plug for connection inside the device.On-site lead extension:& 2-core lead, length up to 60 m with a cross-section of 1.5 mm2

(copper)& Never route this lead immediately next to 230/400 V cables

Lead length 5.8 mProtection IP 32 to EN 60529; safe-

guard through appropri-ate design andinstallation

Sensor type Pt500Permissible ambient temperature– during operation 0 to +90 °C– during storage and transport -20 to +70 °C

For systems with DHW cylinders from Viessmann, the cylindertemperature sensor is installed directly into the sensor well of theelbow threaded into the heating water return.

Rast 5 system plugfor the solar heating circuit pump

KM BUS distributor

Part no. 7415 028For the connection of 2 to 9 devices to the Vitotronic KM BUS.

Specification

Lead length 3.0 m, fully wiredProtection IP 32 to EN 60529;

safeguard through appro-priate design and instal-lation

Permissible ambient temperature– during operation 0 to +40 °C– during storage and transport ‐20 to +65 °C

Notes regarding room temperature hook-up (RS function) for remote control units

Never activate the RS function for underfloor heating circuits(inertia).In heating systems with a heating circuit without mixer and heatingcircuits with mixer, the RS function must only affect the heating cir-cuits with mixer.

Notes regarding the Vitotrol 200 and 300

For every heating circuit in a heating system, one Vitotrol 200 orone Vitotrol 300 can be deployed.

NoteObserve the following part numbers.

5822413GB

12 VIESMANN VITOLIGNO 300-P

Accessories for the Vitotronic 300, type FW1 (cont.)

Page 13: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

Vitotrol 200

Part no. 7450 017KM BUS subscriberThe Vitotrol 200 remote control regulates the heating program forone heating circuit and the required set room temperature in stan-dard mode, from any room in the house.The Vitotrol 200 is equipped with backlit heating program selec-tion keys as well as a party and economy key.The fault display shows faults on the control unit.WS function:Installation anywhere in the building.RS function:Installation in the main living room on an internal wall oppositeradiators. Never install inside shelf units, recesses, immediatelyby a door or heat source (e.g. direct sunlight, fireplace, TV set,etc.).The integral room temperature sensor captures the actual roomtemperature and effects any necessary correction of the flow tem-perature as well as a rapid heat-up at the start of the heatingoperation (if appropriately programmed).Connection:& 2-core lead, length max. 50 m (even if connecting severalremote control units)

& Never route this lead immediately next to 230/400 V cables& LV plug part of the standard delivery

SpecificationPower supply via KM BUSPower consumption 0.2 WProtection class IIIProtection level IP 30 to EN 60529;

safeguard through appro-priate design and instal-lation

Permissible ambient temperature– during operation 0 to +40 °C– during storage and transport −20 to +65 °CSet room temperature range 10 to 30 °C

adjustable from3 to 23 °C or17 to 37 °C

The set room temperature for reduced mode is adjusted at thecontrol unit.

Vitotrol 300

Part no. 7248 907KM BUS subscriberThe Vitotrol 300 remote control regulates the required set roomtemperature for one heating circuit in standard and reduced mode,the heating program and the switching times for central heating,DHW heating and the DHW circulation pump.The Vitotrol 300 provides an illuminated display as well as illumi-nated heating program keys, a party and economy key, automaticsummer/winter time changeover, keys for holiday program, dayand time.WS function:Installation at any point in the building.RS function:Installation in the main living room on an internal wall oppositeradiators. Never install inside shelf units, niches, immediately by adoor or heat source (e.g. direct sunlight, fireplace, TV set, etc.).The integral room temperature sensor captures the actual roomtemperature and effects any necessary correction of the flow tem-perature as well as a rapid heat-up at the start of the heatingoperation (if suitably encoded).Connection:& 2-core lead, length max. 50 m (even if connecting severalremote control units)

& Never route this lead immediately next to 230/400 V cables& LV plug as standard delivery

SpecificationPower supply via KM BUSPower consumption 0.5 WProtection class IIIProtection IP 30 to EN 60529;

safeguard through appro-priate design and instal-lation

Permissible ambient temperature– during operation 0 to +40 °C– during storage and transport -20 to +65 °CSet room temperature range– for standard mode 10 to 30 °C

adjustable to3 to 23 °C or17 to 37 °C

– for reduced mode 3 to 37 °C

5822413GB

VITOLIGNO 300-P VIESMANN 13

Accessories for the Vitotronic 300, type FW1 (cont.)

Page 14: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

Room temperature sensor

Part no. 7408 012Separate room temperature sensor as supplement to the Vitotrol200 and 300; to be used if the Vitotrol 200 or 300 cannot beinstalled inside the main living room or in a suitable position wherethe unit can capture and adjust the temperature.Installation in the main living room on an internal wall oppositeradiators. Never install inside shelf units, recesses, immediatelyby a door or heat source (e.g. direct sunlight, fireplace, TV set,etc.).Connect the room temperature sensor to the Vitotrol 200 or 300.Connection:& 2-core lead with a cross-section of 1.5 mm2 (copper)& Lead length from the remote control up to 30 m& Never route this lead immediately next to 230/400 V cables

SpecificationProtection class IIIProtection level IP 30 to EN 60529;

safeguard through appro-priate design and instal-lation

Permissible ambient temperature– during operation 0 to +40 °C– during storage and transport −20 to +65 °C

Vitohome 300

Part no. Z005 395Home centre for the wireless individual room temperature controlsystem of central heating systems with radiators and/or underfloorheating.& Increased individual room comfort& Saving heating and power costs& Easy commissioning and easy to retrofit& Complete operation for DHW and central heating

For further information, see "Vitohome 300" datasheet.

Buffer cylinder temperature sensor

Part no. 7267 634 (2 pce. required)For the operation of the Vitoligno 300-P with a heating water buffercylinder.

Specification

Lead length 5.8 m, fully wiredProtection IP 60 to EN 60529; safe-

guard through appropri-ate design andinstallation

Permissible ambient temperature– during operation 0 to +90 °C– during storage and transport -20 to +70 °C

5822413GB

14 VIESMANN VITOLIGNO 300-P

Accessories for the Vitotronic 300, type FW1 (cont.)

Page 15: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

Radio clock receiver

Part no. 7450 563For receiving the DCF 77 time signal (location: Mainflingen nearFrankfurt/Main).Radio controlled setting of time and date.Install on an outside wall, facing the transmitter. The receptionmay be reduced by metallic elements in the building structure, e.g.steel reinforced concrete, neighbouring buildings and sources ofelectro-magnetic interference, e.g. HV and public transport lines.Connection:& 2-core lead, length up to 35 m with a cross-section of 1.5 mm2

(copper)& Never route this lead immediately next to 230/400 V cables.

Function extension 0–10 V

Part no. 7174 718KM BUS subscriberIncluding cable (3.0 m long) and plugs fÖ and aVG.To default a set boiler water temperature via a 0–10 V input for atemperature range of 10 to 100 °C or 30 to 120 °C (0 to 1 V ≙ boil-er OFF)andto signal reduced mode and regulate a heating circuit pump to alower speed.

Specification

Rated voltage 230 V~Rated frequency 50 HzPower consumption 1 WRated breaking capacity of the relayoutput

4(2) A 230 V

Protection IP 30 to EN 60529; safe-guard through appropri-ate design andinstallation

Permissible ambient temperature– during operation 0 to +40 °C– during storage and transport -20 to +65 °C

Vitocom 100, type GSM

& Without SIM cardPart no. Z004594

& With contract SIM card for the operation of the Vitocom 100 viamobile phonePart no. Z004615

NoteFor further information regarding the conditions of contract, seethe Viessmann pricelist.

Functions:& Remote switching via GSM mobile phone networks& Remote scanning via GSM mobile phone networks& Remote monitoring via SMS to 1 or 2 mobile phones& Remote monitoring of additional systems via digital input (230V)

Configuration:Mobile phones via SMS

Standard delivery:& Vitocom 100 (subject to order with or without SIM card)& Power supply cable with Euro plug (2.0 m long)& GSM aerial (3.0 m long), magnetic foot and adhesive pad& KM BUS cable (3.0 m long)

On-site requirements:Good reception for GSM communication of the selected mobilephone operator.Total length of all KM BUS subscriber cables up to 50 m.

SpecificationRated voltage 230 V ~Rated frequency 50 HzRated current 15 mAPower consumption 4 WProtection class IIProtection IP 41 to EN 60529; safe-

guard through appropriatedesign and installation

Function Type 1B to EN 60 730-1Permissible ambient temperature

5822413GB

VITOLIGNO 300-P VIESMANN 15

Accessories for the Vitotronic 300, type FW1 (cont.)

Page 16: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

– during operation 0 to +55 °CInstallation in living spacesor boiler rooms (standardambient conditions)

– during storage and transport -20 to +85 °COn-site connectionFault input DE 1 230 V~

Vitoligno 300-P accessories

Pellet supply from the pellet storage room to the boiler

Delivery via the auger supply system and a flexible auger

Complete system for delivery with an auger system compris-ing:& flexible supply auger, 3 or 4 m long& Auger supply system for different room depths and connectionto a flexible supply auger

System with flexible supply augerDepth 1.8 A comprising:

– 1 wall module auger system 0.64 m long 1– 1 auger module 1.14 m long 4– 3 panels 5– 1 flexible supply auger 6

Depth 2.3 m B comprising:– 1 wall module auger system 0.64 m long 1– 1 auger module 0.5 m long 2– 1 auger module 1.14 m long 4– 4 panels 5– 1 flexible supply auger 6

Depth 2.9 m C comprising:– 1 wall module auger system 0.64 m long 1– 1 auger module 1.14 m long 3– 1 auger module 1.14 m long 4– 4 panels 5– 1 flexible supply auger 6

Depth 3.4 m D(max. room depth)

comprising:– 1 wall module auger system 0.64 m long 1– 1 auger module 0.5 m long 2– 1 auger module 1.14 m long 7– 1 auger module 1.14 m long 4– 5 panels 5– 1 flexible supply auger 6

5822413GB

16 VIESMANN VITOLIGNO 300-P

Accessories for the Vitotronic 300, type FW1 (cont.)

Page 17: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

NoteClear space for installation (depth) at least 100 mm between theauger supply system and the wall.

Delivery via auger supply system and vacuum system

Complete system for delivery with a vacuum system compris-ing:& Pellet supply and return air hose (7 50 mm), reel of 15 m& Auger supply system for different room depths and connectionto a vacuum system

System with flexible supply augerDepth 1.8 A comprising:

– 1 wall module auger system 0.64 m long 1– 1 auger module 1.14 m long 4– 1 pellet supply and return air hose 15 m long 5

Depth 2.3 m B comprising:– 1 wall module auger system 0.64 m long 1– 1 auger module 0.5 m long 2– 1 auger module 1.14 m long 4– 1 pellet supply and return air hose 15 m long 5

Depth 2.9 m C comprising:– 1 wall module auger system 0.64 m long 1– 1 auger module 1.14 m long 3– 1 auger module 1.14 m long 4– 1 pellet supply and return air hose 15 m long 5

Depth 3.4 m D(max. room depth)

comprising:– 1 wall module auger system 0.64 m long 1– 1 auger module 0.5 m long 2– 1 auger module 1.14 m long 3– 1 auger module 1.14 m long 4– 1 pellet supply and return air hose 15 m long 5

NoteClear space for installation (depth) at least 100 mm between theauger supply system and the wall.

Pellet storage room

Practical experience favours a rectangular footprint for the sto-rage room. Safeguard the easy accessibility of the fill and returnconnectors. The size of the required storage room depends on theheat demand of the building.

5822413GB

VITOLIGNO 300-P VIESMANN 17

Vitoligno 300-P accessories (cont.)

Page 18: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

A Deflector boards at the entrance to the storage roomB Delivery area, auger supply systemC DeflectorD Delivery to the flexible auger or the vacuum systemE min./max. length of the delivery area

F max. storage room lengthG Return air connectorH Delivery connectorK slanted panel to compensate for the different lengths of the

storage room/delivery area

Sectional view, pellet storage room

A Delivery connectorB Return air connectorC Air spaceD Slanted floor

E Empty spaceF Viessmann delivery systemG Available volume = ⅔ of the room

5822413GB

18 VIESMANN VITOLIGNO 300-P

Vitoligno 300-P accessories (cont.)

Page 19: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

Wall openings for the wall modules

Wall module for flexible auger

Wall module vacuum system

A Wall openingB Height of the upper edge with fitted motorC Height of the upper edge with motor removedD Top edge, finished floor

Pellet supply to the boiler

A min. hose lengthB Pellet delivery or connector at the pellet silo

A Pellet delivery or connector at the pellet silo

The boiler supply with flexible auger can either be connected tothe room delivery with auger supply system or to a pellet silo.The rotary:pivot adjuster at the pellet silo / the room delivery aswell as the drive unit of the flexible auger on the Vitoligno can beturned 180°.

5822413GB

VITOLIGNO 300-P VIESMANN 19

Vitoligno 300-P accessories (cont.)

Page 20: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

Pellet storage in a pellet silo

System with flexible auger

Complete system, pellet silo with delivery via flexible augercomprising:& flexible supply auger, 3 or 4 m long& Pellet silo for approx. 3.7 t pellets (type 21) or 5.3 t pellets (type25)

System with vacuum system

Complete system, pellet silo with delivery via vacuum systemcomprising:& Pellet supply and return air hose (reel of 15 m)& Pellet silo for approx. 4.3 t pellets (type 21) or 6.0 t pellets (type25)

Pellet silo

Pellet storage system as textile/metal combination for the storageof wood pellets (acc. to DINplus and Ö-Norm M7135, diameter 6;up to 30 mm in length).

The system is delivered in parts.5822413GB

20 VIESMANN VITOLIGNO 300-P

Vitoligno 300-P accessories (cont.)

Page 21: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

Pellet silo Dimension in mma b c d

Type 21 2100 2100 2200 700Type 25 2500 2500 2200 900

On-site requirements

A Max. load on the central support plate 3000 kgB Max. load per support plate 1500 kg

Pellet silo Dimension in mma b

Type 21 1050 2100Type 25 1250 2500

NoteParticularly with so-called "floating" screeds (unfinished concrete+ insulation layer + screed), there is a risk that they may not meetthe specified requirements.

Additional accessories

& Connection unit, return temperature raising facility for systemswith heating water buffer cylinder

& Safety equipment block& Heating circuit distribution& Three-way diverter valve

& Water level limiter& Boiler flue connection (required for stainless steel flues)& Anti-vibration joint (for installation into the flue)& Draught controller (for wall mounting)See pricelist.

Delivered condition

Steel boiler for wood pellets to DINplus and ÖNORM M7135; pel-let diameter 6 mm; up to 30 mm long.Boiler body (in shipping crate) with fitted thermal insulation mats,integral return temperature raising facility, combustion chamberdoor, ash door, ash box and integral control unit.1 carton with casing panels and cleaning device

1 carton with programming unit Vitotronic 300, type FW11 carton with vacuum fanBag with technical documentationSubject to order:1 pellet hopper1 connection unit for flexible auger

Vitotronic 300, type FW1

& Programming unit& Outside temperature sensor& Boiler water temperature sensor& Cylinder temperature sensor& Bag with technical documentation

Heating system with DHW cylinderOrder the circulation pump with check valve for cylinder tempera-ture control separately.

Heating system incl. heating circuit with mixerAn extension kit (accessories) is required for each heating circuitwith mixer.

Heating system with underfloor heatingAn extension kit for one heating circuit with mixer is required forthe underfloor heating circuit.Install a temperature limiter into the flow of the underfloor heatingcircuit to limit the maximum temperature. Observe the require-ments of DIN 18560-2 [or local regulations].The underfloor heating circuit should not be regulated by a remotecontrol with room temperature hook-up.

Plastic pipework for radiatorsWe also recommend the installation of a temperature limiter tolimit the maximum temperature of plastic pipes in heating circuitswith radiators.

5822413GB

VITOLIGNO 300-P VIESMANN 21

Vitoligno 300-P accessories (cont.)

Page 22: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

Selection of rated output

When selecting a boiler size, the [German] Energy Savings Orderprescribes that the rated output according to EN 12831 orÖNORM M 7500 does not exceed the calculated heat demand.

Fuels

This boiler is only approved for the combustion of commercial,natural wood pellets (max. residual humidity 7 to 12%, diameter 6mm, length 5 to 30 mm acc. to DINplus or ÖNORM M 7135).Pellets must be transported and stored in absolute dry condition.

The following are unsuitable types of fuel:Fossil fuels and those containing sulphur, such as anthracite,coke as well as plastics, grain, chipboard, material soaked in flam-mable liquids, wood chips, sawdust, wood dust or wood and wastewood treated with plastics or wood preservatives.

Hydraulic connection

Never use solid fuel boilers in open heating systems to DIN EN12828. Instead, integrate these boilers in sealed systems to DINEN 12828 , as shown in the installation examples in the technicalguide.Only connect regulated heating circuits with mixer.

Systems without heating water buffer cylinders generally requireno return temperature raising facility, as the Vitoligno 300 isequipped with its own integral return temperature raising facility.Systems with a heating water buffer cylinder require both a shuntpump and a return temperature raising facility.

DHW heating

The DHW cylinder primary pump will only be started when theminimum boiler water temperature of 50 °C has been exceeded.

Safety equipment

The boiler should be equipped with a type-tested safety valve(subject to design) in accordance with DIN EN 12828 for DHWheating systems with a safety temperature of up to 110 °C.This valve must be identified in accordance with TRD 721, i.e.with

& "H" up to 3.0 bar permissible operating pressure and max.2700 kW rated output,

& "D/G/H" for all other operating conditions.

Low water indicator

DIN EN 12828 specifies the use of a low water indicator (availableas accessory).

Flue gas system

Connect the Vitoligno 300-P to highly insulated chimney stacks(thermal resistance class I to DIN 18160-1) or use suitable moist-ure-resistant flue gas systems that have Building Regulationsapproval.Install no more than one 90° bend in the flue pipe to safeguardoptimum combustion. Route the flue pipe into the chimney stackwith an incline (at least 10°, optimum inclination = 45°).Prevent any reductions and additional bends, otherwise the lowpressure inside the chimney may be insufficient for trouble-freeflue gas removal. The combustion could then be impaired.The flue pipe up to the entry into the chimney stack may be a up to3 m long. Insulate the flue pipe over the entire length with at least30 mm thick thermal insulation; the flue pipe must be sound.Install a draught limiter.

Flue gases must be routed from the chimney to the outside in amanner that prevents damage from the precipitation of vaporousflue gas components inside the chimney.Boiler and flue system must be matched to each other; this appliesparticularly to older systems that are being modernised. Preventchimney damage through the following steps (check with yourlocal flue gas inspector):Install a draught stabiliser into the chimney side, thermally insu-late the flue pipe, thermally insulate the chimney in unheatedattics or modernise the chimney.

Sound insulation

Never grout the flue pipe into the chimney to prevent sound trans-mission caused by the induced draught fan.An anti-vibration joint for fitting into the flue is available as acces-sory.

5822413GB

22 VIESMANN VITOLIGNO 300-P

Design information

Page 23: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

CE designation according to current EC Directives.

5822413GB

VITOLIGNO 300-P VIESMANN 23

Tested quality

Page 24: job 1..24 - C2 Energy Ltd NI & Eire · Flue outlet 7 mm 130 130 130 150 150 150 Required draught Pa 5 5 5 5 5 5 ... Specification, Vitotronic 300, type FW1 Design and function Modular

Viessmann Werke GmbH&Co KGD-35107 AllendorfTelephone: +49 6452 70-0Fax: +49 6452 70-2780www.viessmann.com

Subject to technical modifications.

Viessmann LimitedHortonwood 30, TelfordShropshire, TF1 7YP, GBTelephone: +44 1952 675000Fax: +44 1952 675040E-mail: [email protected] 5

822413GB

Printedonenvironmentally

friendly,

chlorine-freebleach

edpaper

24 VIESMANN VITOLIGNO 300-P