keyscan programming worksheets
DESCRIPTION
Help to plan the programming of a Keyscan System VII access control system, the form guide the person on what kind of info is requested before you start to beguin your system configuarationTRANSCRIPT
Programming Worksheets
Site Information
Reader Information
Time Zone Construction
Time Zone Assignment
Auxiliary Input Names
Supervised Input Names – SI #1 – 32
Supervised Input Names – SI #33 – 64
Auxiliary Output Assignments
Door Group Access Information
Elevator Group Access information – Floors # 1 – 8
Elevator Group Access information – Floors # 9 – 16
Elevator Group Access Information – Floors # 17 – 24
Card Holder Enrollment
Elevator Setup
Rev. 02/02
Site Information
Site Name:
(maximum 30 characters)
Site ID:
(maximum 8 characters)
Address:
Contact Information:
Emergency Information:
Unit Type Unit ID
(maximum 6 characters)
Serial Number
(From ACU EPROM)
Rev. 02/02
Reader Information
Site ID:
Unit ID:
Door # Reader Name Output # and Door Name AP Door Mode
Door Mode: • 1 = Request to Exit. Unlocks and shunts door contact. • 2 = Request to Exit. Shunts door contact only. • 3 = Free Egress. Door held open alarms only.
AP • AP = Anti-pass back for controlled enter/exit environment with IN/OUT reader use.
Rev. 02/02
Time Zone Construction
Site ID
Time Zone # Time Zone Name: Unit ID
Mon Tues Wed Thurs Fri Sat Sun Hol
Start : : : : : : : :
Stop : : : : : : : :
Start : : : : : : : :
Stop : : : : : : : :
Global Time Zone First Person In
Site ID
Time Zone # Time Zone Name: Unit ID
Mon Tues Wed Thurs Fri Sat Sun Hol
Start : : : : : : : :
Stop : : : : : : : :
Start : : : : : : : :
Stop : : : : : : : :
Global Time Zone First Person In
Site ID
Time Zone # Time Zone Name: Unit ID
Mon Tues Wed Thurs Fri Sat Sun Hol
Start : : : : : : : :
Stop : : : : : : : :
Start : : : : : : : :
Stop : : : : : : : :
Global Time Zone First Person In
Rev. 02/02
Time Zone Assignment
Site ID
Unit ID
TZ # Doors/Floors Auxiliary Inputs Auxiliary Outputs
Supervisory Inputs
Reader/Keypad Operation
1 DR1 =
Zone On =
Zone Off =
2 DR1 =
Zone On =
Zone Off =
3 DR1 =
Zone On =
Zone Off =
4 DR1 =
Zone On =
Zone Off =
5 DR1 =
Zone On =
Zone Off =
6 DR1 =
Zone On =
Zone Off =
7 DR1 =
Zone On =
Zone Off =
8 DR1 =
Zone On =
Zone Off =
Reader/Keypad Operation Assign a time zone (DR# = time zone #) and specify the mode of access with respect to cards and keypads when the time zone is on (Zone = On) and when the time zone is off (Zone = Off) using the following legend: • Card Only = C • Card and/or Keypad = C/K • Card and Keypad = C&K
Rev. 02/02
Auxiliary Input Names
Site ID
Unit ID
Auxiliary Input Auxiliary Name
AI # 1
AI # 2
AI # 3
AI # 4
AI # 5
AI # 6
AI # 7
AI # 8
AI # 9 – AI # 16 are only available on CA 4000 and CA 8000 ACU models.
AI # 9
AI # 10
AI # 11
AI # 12
AI # 13
AI # 14
AI # 15
AI # 16
Rev. 02/02
Supervised Input Names Supervised Inputs are only available on CA 4000 and CA 8000 ACU models.
Site ID
Unit ID
Supervised Input Supervised Input Name
SI # 1
SI # 2
SI # 3
SI # 4
SI # 5
SI # 6
SI # 7
SI # 8
SI # 9
SI # 10
SI # 11
SI # 12
SI # 13
SI # 14
SI # 15
SI # 16
SI # 17
SI # 18
SI # 19
SI # 20
SI # 21
SI # 22
SI # 23
SI # 24
SI # 25
SI # 26
SI # 27
SI # 28
SI # 29
SI # 30
SI # 31
SI # 32
Rev. 02/02
Supervised Input Names Supervised Inputs are only available on CA 4000 and CA 8000 ACU models.
Site ID
Unit ID
Supervised Input Supervised Input Name
SI # 33
SI # 34
SI # 35
SI # 36
SI # 37
SI # 38
SI # 39
SI # 40
SI # 41
SI # 42
SI # 43
SI # 44
SI # 45
SI # 46
SI # 47
SI # 48
SI # 49
SI # 50
SI # 51
SI # 52
SI # 53
SI # 54
SI # 55
SI # 56
SI # 57
SI # 58
SI # 59
SI # 60
SI # 61
SI # 62
SI # 63
SI # 64
Rev. 02/02
Auxiliary Output Assignments
Site ID
Unit ID
AO # Auxiliary Output Name AO # Auxiliary Output Name
AO # 1 AO # 2
AO # 3 AO # 4
AO # 5 AO # 6
*AO # 7 *AO # 8
Door Held Open
Door Forced Open
Auxiliary Inputs *Supervised Inputs
DR1= DR1= 1= *9= 1= 9= 17= 25=
DR2= DR2= 2= *10= 2= 10= 18= 26=
DR3= DR3= 3= *11= 3= 11= 19= 27=
DR4= DR4= 4= *12= 4= 12= 20= 28=
DR5= DR5= 5= *13= 5= 13= 21= 29=
DR6= DR6= 6= *14= 6= 14= 22= 30=
DR7= DR7= 7= *15= 7= 15= 23= 31=
DR8= DR8= 8= *16= 8= 16= 24= 32=
Invalid Code Alarm = Power Failure Alarm = Keypad Duress Output = * Only available on CA4000 and CA 8000 ACU models.
Rev. 02/02
Door Group Access Information
Site ID
Unit ID
Door #
1 2 3 4 5 6 7 8
Door Group Name Door Group Access Level
Door Access Levels • 24 Hour Access = 24HR • Time Zone Limited Access = TZ-### • No Access = N/A
Rev. 02/02
Elevator Group Access Information
Site ID
Unit ID
Elevator Bank
Elevator Floor #
1 2 3 4 5 6 7 8
Elevator Group Name Elevator Group Access Level
Elevator Access Levels • 24 Hour Access = 24HR • Time Zone Limited Access = TZ-### • No Access = N/A
Rev. 02/02
Elevator Group Access Information
Site ID
Unit ID
Elevator Bank
Elevator Floor #
9 10 11 12 13 14 15 16
Elevator Group Name Elevator Group Access Level
Elevator Access Levels • 24 Hour Access = 24HR • Time Zone Limited Access = TZ-### • No Access = N/A
Rev. 02/02
Elevator Group Access Information
Site ID
Unit ID
Elevator Bank
Elevator Floor #
17 18 19 20 21 22 23 24
Elevator Group Name Elevator Group Access Level
Elevator Access Levels • 24 Hour Access = 24HR • Time Zone Limited Access = TZ-### • No Access = N/A
Rev. 02/02
Cardholder Enrollment
Site ID
Unit ID
First Name Last Name Batch # Card # PIN Door Group Elevator Group
Telephone Ext. Fax # Email Address
Card Location
Parking Spot #
Car Plate Bar Code
Optional Cardholder Information
Field # 1 Field # 2 Field # 3 Field # 4 Field # 5
Field # 6 Field # 7 Field # 8 Field # 9 Field # 10
Rev. 02/02
Rev. 02/02
Elevator Setup
Site ID
Elevator Bank Name
Floor # Floor Name TZ # Floor # Floor Name TZ#
(OP) 1 (OP) 2
(OP) 3 (OP) 4
(OP) 5 (OP) 6
(OP) 7 (OP) 8
(OP) 9 (OP) 10
(OP) 11 (OP) 12
(OP) 13 (OP) 14
(OP) 15 (OP) 16
(OP) 17 (OP) 18
(OP) 19 (OP) 20
(OP) 21 (OP) 22
(OP) 23 (OP) 24
(OP) 25 (OP) 26
(OP) 27 (OP) 28
(OP) 29 (OP) 30
(OP) 31 (OP) 32
(OP) 33 (OP) 34
(OP) 35 (OP) 36
(OP) 37 (OP) 38
(OP) 39 (OP) 40