kg karting - test iso 5011:2000 - filtro hr22-d12 ......2013/03/15 · po_inc flow rate...
TRANSCRIPT
Commessa interna:Internal reference:
RichiedenteCustomer
Ente/Società (Dept/Firm): KG s.a.s. di Pierluigi Giacoletto & C. Sig. (Mr.): Davide Gaggianesi
Indirizzo (Address):Rapporto di prova inviato a:Report sent to:
Firma esecutore prove:Signature of test executor:
Firma Responsabile Laboratorio:Signature of Laboratory Manager:
Data ricevimento campioni:Date of test samples receipt:
Data esecuzione prove:Date of test execution:
Località esecuzione prove:Site of test execution:
Scopo delle prove:Purpose if test:
Norme/specifiche tecniche:Standard/Technical specifications:
Eventuali scostamenti, aggiunte o limitazioni:
Possible differences, additions or limitations:
Assembly: \Paper type: \
\
I risultati del presente rapporto di prova si riferiscono esclusivamente al campione sottoposto a prova.
The test results contained in this Test report relate to the tested samples only.E' ammessa la riproduzione integrale del presente Rapporto di prova da parte del Richiedente; la riproduzione parziale dev'essere autorizzata per iscritto dal Laboratorio.
The integral reproduction of the present Test report is allowed; the partial reproduction must be authorized in wrìting by the Laboratory.
KG KARTING - Test ISO 5011:2000 - Filtro HR22-d12 - Modello APE1 - Omologazione n°
3/SA/18 - Report n° 13/026 Data: 13/03/2013
\
2 Condizioni di prova:
Test conditions:vedere pag. n°3
689-13
1 Campioni / identificazione
Test unit / identification
1791-13
Davide Gaggianesi
ISO 5011:2000
13/03/2013
Massimo Ellena
Ivano Ottino
13/03/2013
Laboratorio Texa - Via S. Gribaudo 22/A 10036 Chivasso (To) - Italy
Texa code:
Filter element:The methods of sampling and transport of items are provided by the customer
KG s.a.s. di Pierluigi Giacoletto & C.Model/Type n°:Manufacturer:
Filtro HR22-d12 Modello APE1 - Omologazione n° 3/SA/18
Viale America, 1 - 10081 Castellamonte, (TO) ITALY
Validazione
Note of test method: /
LAB N° 1202
RP-026-13-KG Karting-Test according to ISO5011 filter HR22-d12.xls Pag.1/4
Applied method for Efficiency calculation:
A) Final filter method Efficiency
B) Direct method Efficiency
Sample mounted on test equipment
ESITO CONFORME: l'efficienza in massa finale 95,50% (o filtration
performance µ) è superiore al valore limite di accettabilità del 85% (µ ≥
85% è il requisito indicato al §8.8.4 Appendix 1 (I) del Reglement
d'Homologation CIK-FIA 2013)
The test equipment used is subjected to calibration plan according to Texa Quality System
Test system for ISO 5011- cod. ATT115
Pressure drop e Dust/Efficiency test vedere pag. n°3
4 Commenti generali:
General comments:
Ei=((mDi-(mFi-mFi-1))/mDi)*100 with
mDi=total dust fed; mFi=final filter weight; mFi-1=final filter weight at
the previous step
Ei=((mUi-mUi-1)/mDi)*100 with
mDi=total dust fed; mUi=filter under test final weight; mUi-1=filter
under test weight at the previous step
3 Risultati di prova:
Test results:
KG KARTING - Test ISO 5011:2000 - Filtro HR22-d12 - Modello APE1 - Omologazione n°
3/SA/18 - Report n° 13/026 Data: 13/03/2013
5 Impianto di prova:
Test equipment:
X
LAB N° 1202
RP-026-13-KG Karting-Test according to ISO5011 filter HR22-d12.xls Pag.2/4
126
7,70
22,0
55,0
975
84,0 53,0
Test air flow: steady: X 57,0
variable: Min Temperature [°C]: 21,5
Dust type: ISO12103-1 A4 COARSE Max Temperature [°C]: 22,5
Batch n.: 10465C 975
Dust supplier: 975
1,000 50,00
Max dust fed [g]: 6,0 Capacity (at test terminal condition) [g]: 5,70
4,26 54,26
\ 95,50
Applied method: Test terminal condition:
Air feed pressure: > 1bar Number of used dust injctors: 2
Max Dp increase[mbar]:
Pressure drop before dust [mbar]: Pressure drop after dust [mbar]:
Full-life Efficiency [%]:
direct weighting see max Dp increase
Initial Efficiency [%]:
Barometric pressure before test [mbar]:
Barometric pressure after test [mbar]:
PRESSURE DROP VS MASS OF DUST FED / EFFICIENCY
Min. Rel. Humidity [%]:
Max Rel. Humidity [%]:
Rated Air flow [m3/h] :
Barometric pressure [mbar]:
Max air flow [m3/h]:
PRESSURE DROP OF CLEAN FILTER - TEXA cod. 689-13
KG KARTING - Test ISO 5011:2000 - Filtro HR22-d12 - Modello APE1 - Omologazione n°
3/SA/18 - Report n° 13/026 Data: 13/03/2013
Max Dp static - Restriction [mbar]:
Dust concentration [g/m³]:
PTI
Temperature [°C]:
Rel. Humidity [%]:
Pressure drop vs. mass of dust fed and efficiency
6,0g; 95,50%
0
10
20
30
40
50
60
0 10 20 30 40 50 60
Mass of dust fed [g]
Pre
ssur
e dr
op [
mba
r]
90,0
91,0
92,0
93,0
94,0
95,0
96,0
97,0
98,0
99,0
100,0
Eff
icie
ncy
[%]
Static pressure drop of clean filter + housing
0
2
4
6
8
10
0 10 20 30 40 50 60 70 80 90 100 110 120 130
Air flow [m3/h]
Pre
ssur
e dr
op [
mba
r]
LAB N° 1202
Restriction
84 m3/h4,26 mbar restriction
RP-026-13-KG Karting-Test according to ISO5011 filter HR22-d12.xls Pag.3/4
Uncertainty extensive: 1,05 mbarCoverage factor K: 2
Confidence level: 95%
Evaluation conducted on: 20/5/11 report: inc dp 14-11_cod 264 procedure:
Uncertainty extensive: 2,7 gCoverage factor K: 2
Confidence level: 95%
Evaluation conducted on: 24/5/11 report: inc M 23-11_cod257 procedure:
Evaluation conducted on: 18/4/11 report: inc M 07-11_cod420 procedure:
Efficiency
Uncertainty extensive: see Table 1Dust fed [g] 6,0 \ \
Coverage factor K: 2 E [%] 95,50 \ \
Confidence level: 95% U(E) [%] 2,10 \ \
Punto 1 Punto 2 Punto 3
Uncertainty extensive: 3,0 m3/h Venturi: VT2 s/n V08-0081-2 cod.: 271
Coverage factor K: 2
Confidence level: 95%
Evaluation conducted on: 21/4/11 report: inc flow rate 09-11-cod 271procedure:
TemperatureUncertainty extensive: 0,2 °C
Coverage factor K: 2
Confidence level: 95%
Evaluation conducted on: 19/5/11 report: inc T 12-11_cod262 procedure:PO_inc temp ISO5011-ed.01
Relative humidityUncertainty extensive: 0,7 %
Coverage factor K: 2
Confidence level: 95%
Evaluation conducted on: 19/5/11 report: inc RH 11-11_cod262 procedure:
KG KARTING - Test ISO 5011:2000 - Filtro HR22-d12 - Modello APE1 - Omologazione n°
3/SA/18 - Report n° 13/026 Data: 13/03/2013
INCERTEZZA DI MISURA - MEASUREMENT UNCERTAINTY
PO_Inc flow rate ISO5011-ed01
Dust capacity
Tab
le 1
Differential pressure
PO_Inc uso bilance ISO5011-ed01
PO_inc pressure drop ISO5011-ed.01
Air flow rate
PO_Inc uso bilance ISO5011-ed01
PO_inc UR ISO5011-ed.01
LAB N° 1202
RP-026-13-KG Karting-Test according to ISO5011 filter HR22-d12.xls Pag.4/4