komatsu instructions rev b.pdf

7
REV B Check and Repair instructions for ABB Motors Amendments to motor manual date: 16 .04. 2007 ABB Oy, A. Ziessler, 2007 1. Check Motor for tightness The motor can be checked for tightness with measured air pressure and air flow. Values for a proper tightness are as follows: 45 l/min air flow 10 mbar pressure During pressure check the motor must be complete mounted with all parts. 2. Cracks between cooler housing and cooler duct plates - The cooler inlet has to be checked for cracks and tightness. The seam between cooler housing and cooler duct mounting plate must be undamaged. Insufficient sealing on marked area - In case of insufficient condition, the loose seam has to be removed and cleaned with DUGR 5. The seam

Upload: jacklyn-ade-putra

Post on 13-Dec-2015

234 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Komatsu instructions REV B.pdf

REV B Check and Repair instructions for ABB Motors

Amendments to motor manual date: 16 .04. 2007

ABB Oy, A. Ziessler, 2007

1. Check Motor for tightness

The motor can be checked for tightness with measured air pressure and air flow. Values for a proper tightness are as follows: 45 l/min air flow 10 mbar pressure During pressure check the motor must be complete mounted with all parts.

2. Cracks between cooler housing and cooler duct plates - The cooler inlet has to be checked for cracks and

tightness. The seam between cooler housing and cooler duct mounting plate must be undamaged.

Insufficient sealing on marked area - In case of insufficient condition, the loose seam has to

be removed and cleaned with DUGR 5. The seam

Page 2: Komatsu instructions REV B.pdf

REV B Check and Repair instructions for ABB Motors

Amendments to motor manual date: 16 .04. 2007

ABB Oy, A. Ziessler, 2007

must be resealed with Loctite 9492.

Properly finished seam between plate and housing

3 Sealing between motor housing and cooler

- The sealing between motor housing and cooler must be checked for correct fit. The sealing must be continuous without any gaps.

Page 3: Komatsu instructions REV B.pdf

REV B Check and Repair instructions for ABB Motors

Amendments to motor manual date: 16 .04. 2007

ABB Oy, A. Ziessler, 2007

Proper fit of the sealing - The fastening of the cooler must be checked for

tightness. The mounting bolts must be tightened so that the cooler housing is connected to the metal sealing rails and the sealing is properly pressed.

Proper tightening of cooler unit - If the cooling unit is removed, the condition of the

sealing must be checked. The sealing must fit between the rails and must be undamaged. In case of damage, the complete seal must be replaced.

Page 4: Komatsu instructions REV B.pdf

REV B Check and Repair instructions for ABB Motors

Amendments to motor manual date: 16 .04. 2007

ABB Oy, A. Ziessler, 2007

The sealing is fitted and glued correctly, see connection point.

Correctly connected seal

4 General cleaning instructions The motor must not be cleaned with high pressured water. Risk of damaging the gaskets. - The air channels, the fan and the cooler ducts must be

cleaned regularly to avoid packing of dirt and to ensure sufficient cooling capacity. Clogged cooler ducts increases the risk of motor damages.

- The cleaning interval depends on the dust conditions

Page 5: Komatsu instructions REV B.pdf

REV B Check and Repair instructions for ABB Motors

Amendments to motor manual date: 16 .04. 2007

ABB Oy, A. Ziessler, 2007

but must not be less than one month. - The air ducts must be cleaned mechanically with

pressure air and e.g. a suitable brush.

Ensure that the air channels are clean.

Air channels with extreme dust contamination

Page 6: Komatsu instructions REV B.pdf

REV B Check and Repair instructions for ABB Motors

Amendments to motor manual date: 16 .04. 2007

ABB Oy, A. Ziessler, 2007

- The Fan must be cleaned mechanically. Cleaning with water is not allowed. Risk of residual unbalance caused by packed dirt.

External fan with extreme dust contamination

5 Unprotected connection points

- The motors must be checked for unprotected connection points. In motors production->2006, the connection holes might be present. These holes must be tightened.

The unprotected connection points must be tightened

6 Maintenance

Page 7: Komatsu instructions REV B.pdf

REV B Check and Repair instructions for ABB Motors

Amendments to motor manual date: 16 .04. 2007

ABB Oy, A. Ziessler, 2007

It is very important that the motor is maintained according to manufacturer’s instructions.

- Greasing interval of 1000h 100g/bearing.

Recommended grease is Mobilith SHC 100 (lithium complex base). The grease box must be cleaned from excess grease every 6 Moths.

- Monthly cleaning of the motor air channels and fan to ensure proper cooling capacity and preventing of vibrations in the fan.