114
HEAT RECOVERY
ADJUSTMENT CAN BE COMBINED WITH STANDARD CONTROLS
HH
AAAWWWWW
KPI Series E and HIndoor unit - enthalpy recovery system
System Free Ventilation
With the KPI cross flow heat recovery units it is possible - depending on the type of exchange pack - to perform enthalpic heat recovery (Series E) or of sensible heat recovery only (series H).This lets you reduce the power requirements of air conditioning systems where continuous ambient air renewal is required.Moreover, thanks to the new internal geometrical layout, which supports linear flow between ambient air intake and extraction ducts, installation in the field is easier and above all does not feature the typical duct crossing issues of standard models.KPI heat recovery units assure the environment has fresh, clean and pleasant air
using the combined control with the SYSTEM FREE conditioning system.
Celluloid exchange pack for series E Aluminium exchange pack for series H Horizontal or vertical installation for series E Horizontal installation H Nominal airflow from 250 to 3000m3/h Direct flow exchanger Power input harmonised with EuP Standards Lot 11 in force from 2013 Class M1 fire resistance Standard supplied G3 filters, F7 accessories Control by CO2 sensor (not supplied by
HITACHI) Maintaining the rooms in over-pressure
External heater control (not supplied by HITACHI) Switch-on delay Total compatibility with COMMERCIAL
and VRF SET FREE systems Control by means of PC-ART, PC-ARF,
PC-ARH controllers (accessories)
115
System Free Ventilation
(1) Static pressure with standard ventilation setting(2) Sound pressure level measured at 1.5 metres below the unit with acoustically insulated duct (measured in anechoic room)In the event of fresh outside air lower than -5°C (DB) an electrical heater must be installed (not supplied)
(1) Static pressure with standard ventilation setting(2) Sound pressure level measured at 1.5 metres below the unit with acoustically insulated duct (measured in anechoic room)In the event of fresh outside air lower than -5°C (DB) an electrical heater must be installed (not supplied)
KPI SERIES E TECHNICAL DATACODE KPI-252E3E KPI-502E3E KPI-802E3E KPI-1002E3E KPI-1502E3E KPI-2002E3E
Power Supply V-Hz 220V - 50Hz 220V - 50Hz 220V - 50Hz 220V - 50Hz 220V - 50Hz 220V - 50Hz
Nominal input power W 50 80 210 260 470 580
Air flow (L/M/H) m³/h 180/208/250 360/420/500 597/700/800 620/800/1000 970/1250/1500 1240/1560/2000
Static pressure (L/M/H) (1) Pa 30/40/60 47/50/77 55/75/100 50/80/120 60/90/132 60/84/135
Sound pressure (L/M/H) (2) dbA 24/26/27 27/28/30 30/31/32 30/32/35 33/35/37 35/38/39
Efficiency
thermal exchange % 75 75 75 78 78 78
enthalpy exchangecooling % 60 61 62 62 62.5 61.5
heating % 66 65 65 68 68 66.5
Type of exchanger celluloid
Dimensions HxLxD mm 270/900/750 330/1130/920 385/1210/1015 385/1600/1295 525/1800/1130 525/1800/1430
Duct diameter mm 150 200 250 300 355 355
Weight kg 34 46 51 79 97 106
List price € 1741 2,337 3,116 3,803 4,399 5,224
KPI SERIES H TECHNICAL DATACODE KPI-502H3E KPI-802H3E KPI-1002H3E KPI-1502H3E KPI-2002H3E
Power Supply V-Hz 220V - 50Hz 220V - 50Hz 220V - 50Hz 220V - 50Hz 220V - 50Hz
Nominal input power W 80 210 260 470 580
Air flow (L/M/H) m³/h 360/420/500 597/700/800 620/800/1000 970/1250/1500 1240/1560/2000
Static pressure (L/M/H) (1) Pa 47/50/77 55/75/100 50/80/120 60/90/132 60/84/135
Sound pressure (L/M/H) (2) dbA 30/31/33 33/34/35 33/35/38 35/36/40 38/41/42
Efficiency
thermal exchange % 53 50 50 49 48
enthalpy exchangecooling % 30 28 28 27 28
heating % 35 34 33 31 31
Type of exchanger aluminium
Dimensions HxLxD mm 330/1130/920 385/1210/1015 385/1600/1295 525/1800/1130 525/1800/1430
Duct diameter mm 200 250 300 355 355
Weight kg 50 55 85 101 110
PRICE € 2,337 3,116 3,803 4,399 5,224
Connectible with:
PC ARH PC ART PC ARF
Please refer to page 188 for the prices.