lab code 200989-0 report of test...

3
USA: LightLab International Inc. Ph : +1 623-434-1499 24825 N. 16 th Avenue Fx : +1 623-434-1492 Suite 125 www.lightlabint.com Phoenix, AZ, 85085 (Issuing laboratory) Australasia & S.E.Asia: LightLab International Ph : +61 7 3283 7862 50 Recliffe Gardens Drive Fx : +61 7 3283 8751 Clontarf www.lightlab.com.au Queensland, 4019, Australia LightLab I N T E R N A T I O N A L Lab Code 200989-0 This document is issued in accordance with the accreditation requirements of NVLAP. The laboratory is accredited for compliance with ISO/IEC 17025. The results of the tests, calibrations and/or measurements included in this document are traceable to the SI system of units. Report of Test T15211-2-ISTM Product: Cat No. HE-ENV-180W-LHB-PS-UNV. Prepared for: Envirolux Energy Systems. This test report was issued by LightLab International without alterations or erasures. Page 1 of 3 RT

Upload: others

Post on 06-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Lab Code 200989-0 Report of Test T15211-2-ISTMenvirolux.net/wp-content/uploads/2015/12/In-SITU-HEAT-Test-T15211-2-ISTM-180...Test Report Number T15211-2-ISTM Photographs: Test Results:

USA: LightLab International Inc. Ph : +1 623-434-149924825 N. 16th Avenue Fx : +1 623-434-1492Suite 125 www.lightlabint.comPhoenix, AZ, 85085 (Issuing laboratory)

Australasia & S.E.Asia: LightLab International Ph : +61 7 3283 786250 Recliffe Gardens Drive Fx : +61 7 3283 8751Clontarf www.lightlab.com.auQueensland, 4019, Australia

LightLab I N T E R N A T I O N A L

Lab Code 200989-0

This document is issued in accordance with the accreditation requirements of NVLAP. The laboratory is accredited for compliance with ISO/IEC 17025.The results of the tests, calibrations and/or measurements included in this document are traceable to the SI system of units.

Report of Test

T15211-2-ISTM

Product: Cat No. HE-ENV-180W-LHB-PS-UNV.

Prepared for: Envirolux Energy Systems.

This test report was issued by LightLab International without alterations or erasures. Page 1 of 3 RT

Page 2: Lab Code 200989-0 Report of Test T15211-2-ISTMenvirolux.net/wp-content/uploads/2015/12/In-SITU-HEAT-Test-T15211-2-ISTM-180...Test Report Number T15211-2-ISTM Photographs: Test Results:

USA: LightLab International Inc. Ph : +1 623-434-149924825 N. 16th Avenue Fx : +1 623-434-1492Suite 125 www.lightlabint.comPhoenix, AZ, 85085 (Issuing laboratory)

Australasia & S.E.Asia: LightLab International Ph : +61 7 3283 786250 Recliffe Gardens Drive Fx : +61 7 3283 8751Clontarf www.lightlab.com.auQueensland, 4019, Australia

LightLab I N T E R N A T I O N A L

Lab Code 200989-0

This document is issued in accordance with the accreditation requirements of NVLAP. The laboratory is accredited for compliance with ISO/IEC 17025.The results of the tests, calibrations and/or measurements included in this document are traceable to the SI system of units.

Test Report Number T15211-2-ISTM

Client: Envirolux Energy Systems.

Contact: Terry Grover

Address: 1304 NE 154th Street.Vancouver, WA 98685.

Device(s) Tested: Linear LED Highbay.

Control Gear/Driver: Two AC Electronics Model# AC-98CD2.1APMX LED

Drivers.Nature of Tests: To determine the in-situ temperature of the specified LED Ts point and driver Tcpoint with the luminaire setup per UL1598-2008 while operating under standardlaboratory conditions.

Device Mounting: Suspended Ceiling

LED Test Point LED Thermocouple attachment point (Ts) specified by report number 委-14-04-VLP-0037-TP, issued July 20 2015, by Everlight Electronics, Taiwan.

Sample Selection: This laboratory has not exercised control over the selection of sample(s) beingtested. Testing is performed on the understanding that the significance of thereport is limited to the extent to which the sample(s) is representative ofproduction units.

Disclaimer: This report must not be used by the customer to claim product certification,approval or endorsement by NVLAP, NIST, or any agency of the FederalGovernment.

Procedure: In-situ temperature measurements were performed with the sample suspendedhorizontally on a simulated ceiling in a draft free enclosure. The supply voltageand frequency to the control gear was set according to the Manufacturer'sinstructions and the sample was operated for a minimum of 7.5 hours prior torecording measurements.

All measurements were performed in a controlled environment of 25 +/- 5 C.

This test report was issued by LightLab International without alterations or erasures. Page 2 of 3 RT

Page 3: Lab Code 200989-0 Report of Test T15211-2-ISTMenvirolux.net/wp-content/uploads/2015/12/In-SITU-HEAT-Test-T15211-2-ISTM-180...Test Report Number T15211-2-ISTM Photographs: Test Results:

USA: LightLab International Inc. Ph : +1 623-434-149924825 N. 16th Avenue Fx : +1 623-434-1492Suite 125 www.lightlabint.comPhoenix, AZ, 85085 (Issuing laboratory)

Australasia & S.E.Asia: LightLab International Ph : +61 7 3283 786250 Recliffe Gardens Drive Fx : +61 7 3283 8751Clontarf www.lightlab.com.auQueensland, 4019, Australia

LightLab I N T E R N A T I O N A L

Lab Code 200989-0

This document is issued in accordance with the accreditation requirements of NVLAP. The laboratory is accredited for compliance with ISO/IEC 17025.The results of the tests, calibrations and/or measurements included in this document are traceable to the SI system of units.

Test Report Number T15211-2-ISTM

Photographs:

Test Results:

Electrical Measurements

VoltageSupply 120 Vac

Temperature measurements

LED L170 (T/C 1) 54.2 ºCPower 199 W Driver Tc (T/C 3) 61.9 ºC

Above measurements have been normalized to a 25ºC ambient.Current 1.66 A ac Frequency 60 Hz Ambient 24.6 ºC

Power Factor 1.00Driver Output 2.12 A dc

Date of Test: 08/25/2015Date of Report: 08/27/2015

Tested By : ____________________Ben Southgate

Authorized Signatory : _____________________Ryder Tunney

ISTM Report Version V2-6

This test report was issued by LightLab International without alterations or erasures. Page 3 of 3

B Southgate

RT