lab tests 1.3 weatherford scaling tests - a beseth...

18
1.3 Weatherford Scaling Tests Date: 2005 Country: US Keywords: Limescale, Oil Industry Filename: LabTest Weatherford.pdf Weatherford International are a large company providing products and services to the oilfield industry. Laboratory tests were performed in order to determine if Hydroflow could be used to prevent scaling in oil wells. Weath- erford have since purchased a license to manufacture the technology and have exclusive rights to treating limescale in “up-stream” oil and gas field applications. Method of Testing Water was passed through narrow tubes and simultaneously heated. The pressure due to blockages was measured and the tubes examined by eye. The water contained ions that cause both barium sulphate scale and cal- cium carbonate scale (limescale). Tube of different diameter were used and the flow rate was altered. Figure 1.3: The scaling of an untreated pipe (left) compared to a pipe treated with Hydropath (right) (page 10). Results Without treatment, the pipe became blocked in just seven minutes (test 1A, page 4). The blockage was solid and it took a high pressure to clear it (page 4). The Hydropath unit used was shown to cause the scale to form in suspension rather than on the surfaces of the tubes. In tests 1 and 2, the 8 c Hydropath Holdings Ltd. Lab Tests

Upload: vanxuyen

Post on 02-Apr-2018

224 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Lab Tests 1.3 Weatherford Scaling Tests - a Beseth LPCjerseywatersolutions.com/.../2011/09/LabTest-Weatherford-SCALING.pdf · 1.3 Weatherford Scaling Tests Date: 2005 Country: US

1.3 Weatherford Scaling Tests

Date: 2005Country: USKeywords: Limescale, Oil IndustryFilename: LabTest Weatherford.pdf

Weatherford International are a large company providing products andservices to the oilfield industry. Laboratory tests were performed in order todetermine if Hydroflow could be used to prevent scaling in oil wells. Weath-erford have since purchased a license to manufacture the technology andhave exclusive rights to treating limescale in “up-stream” oil and gas fieldapplications.

Method of TestingWater was passed through narrow tubes and simultaneously heated. Thepressure due to blockages was measured and the tubes examined by eye.The water contained ions that cause both barium sulphate scale and cal-cium carbonate scale (limescale). Tube of different diameter were used andthe flow rate was altered.

Figure 1.3: The scaling of an untreated pipe (left) compared to a pipe treatedwith Hydropath (right) (page 10).

ResultsWithout treatment, the pipe became blocked in just seven minutes (test1A, page 4). The blockage was solid and it took a high pressure to clear it(page 4). The Hydropath unit used was shown to cause the scale to form insuspension rather than on the surfaces of the tubes. In tests 1 and 2, the

8 c© Hydropath Holdings Ltd.

Lab Tests

Page 2: Lab Tests 1.3 Weatherford Scaling Tests - a Beseth LPCjerseywatersolutions.com/.../2011/09/LabTest-Weatherford-SCALING.pdf · 1.3 Weatherford Scaling Tests Date: 2005 Country: US

tubes used for testing were very narrow and the water had a very low flowrate, so a small pressure increase can be seen in the treated system until thewater washes away the precipitate (page 5). Test 3 used a 1

4 inch tube witha higher flow rate.

The difference in the amount of scale formed on the pipes with andwithout Hydropath was observed visually. Not only was there significantlymore scale on the untreated system, but it could easily be seen that thescale was hard and required manual scraping, unlike tin the treated system,where the deposits were soft, powder-like and easily brushed away.

9 c© Hydropath Holdings Ltd.

Lab Tests

Page 3: Lab Tests 1.3 Weatherford Scaling Tests - a Beseth LPCjerseywatersolutions.com/.../2011/09/LabTest-Weatherford-SCALING.pdf · 1.3 Weatherford Scaling Tests Date: 2005 Country: US

WEATHERFORD INTERNATIONAL INC.

CLEARWELL SCALE INHIBITION RESEARCH STUDY

Prepared for

Prepared by

Hycal Energy Research Laboratories Ltd.

March 11, 2005 Services performed by Hycal for this report are conducted in a manner consistent with recognized engineering standards and principles. Engineering judgement has been applied in developing the conclusions and/or recommendations contained in this report. Hycal accepts no liability for the use of the data, conclusions or recommendations provided. Hycal File #: N901RE (2005)

Page 4: Lab Tests 1.3 Weatherford Scaling Tests - a Beseth LPCjerseywatersolutions.com/.../2011/09/LabTest-Weatherford-SCALING.pdf · 1.3 Weatherford Scaling Tests Date: 2005 Country: US

Weatherford International Inc. Clearwell Scale Inhibition Research Study

Hycal File #: N901RE (2005)

i

TABLE OF CONTENTS Page TABLE OF CONTENTS i List of Appendices ii SUMMARY 1 Study Objective 1 Conclusions 1 DISCUSSION 3 Test 1: Dynamic Tube Block Test Using ⅛” Tubing Coils and Barium

Sulfate Scaling Brines 3 Test 1A: Untreated 3 Test 1B: Hydropath Treated System 5 Test 2: ¼” Tube Block Test Using Barium Sulfate and Scaling Brines 6 Test 2A: Untreated with ¼” Tubing 6 Test 2B: Treated with ¼” Tubing 8 Test 3: ¼” Tube Block Test at High Flow Rates Using Incompatible Barium Sulfate and Calcium Carbonate Brines 8 Test 3A: Untreated System 8 Test 3B: ¼” High Flow Rate Treated with Hydropath Unit 10

DESCRIPTION OF EQUIPMENT 11 Pressure Measurement 11 Temperature Control 11

Tony Ma General Manager Weatherford – Hycal Laboratories Calgary, Canada

Page 5: Lab Tests 1.3 Weatherford Scaling Tests - a Beseth LPCjerseywatersolutions.com/.../2011/09/LabTest-Weatherford-SCALING.pdf · 1.3 Weatherford Scaling Tests Date: 2005 Country: US

Weatherford International Inc. Clearwell Scale Inhibition Research Study

Hycal File #: N901RE (2005)

ii

List of Appendices APPENDIX A: Brine Compositions APPENDIX B: Clearwell Technical Data

Page 6: Lab Tests 1.3 Weatherford Scaling Tests - a Beseth LPCjerseywatersolutions.com/.../2011/09/LabTest-Weatherford-SCALING.pdf · 1.3 Weatherford Scaling Tests Date: 2005 Country: US

Weatherford International Inc. Clearwell Scale Inhibition Research Study

Hycal File #: N901RE (2005)

1

SUMMARY

Study Objective

At the request of Mr. Stuart Ferguson of Weatherford International Inc. (Weatherford),

Hycal Energy Research Laboratories Ltd. (Hycal) conducted a laboratory study to investigate the

viability of a technology known as Clearwell Hydropath scale inhibition. The objective of this

study was to evaluate the Clearwell Hydropath scale inhibition unit to determine if the unit

prevented scale on pipe walls for field applications. Weatherford is considering licensing or

acquiring the technology to provide as a service to its clients. The unit is designed to create an

electrical field around tubing. This electrical field in turn creates seed crystals held in suspension

in the aqueous phase. These seed crystals act as sights for other crystals to attach and grow

rather than attaching to the tubing walls to create scale. As the crystals grow, they are carried in

suspension in the aqueous phase (see Appendix B for Clearwell technical data).

Conclusions

The following conclusions are provided to enhance understanding of the laboratory data

and offer additional insight relative to Hycal's experience with laboratory and field processes.

They represent our interpretation as to possible mechanisms and physical phenomena that may

be occurring within the laboratory models that have been studied.

These laboratory experiments are micro-scale representations of the field scenario;

however, macro-scale phenomena may override behaviour exhibited in the laboratory. A more

thorough development of these conclusions is presented in the "Discussion" section.

1. A tube block experiment was designed to create an environment for the potential of barium sulfate scale using incompatible brines with a salinity of 90,000 ppm.

2. The system was heated to 50°C and run atmospheric pressure. 3. The results indicate that use of the Clearwell Hydropath technology reduces the tendency

of scale formation on tubing walls by the formation of seed crystals creating adhesion sights while in suspension in an aqueous phase.

Page 7: Lab Tests 1.3 Weatherford Scaling Tests - a Beseth LPCjerseywatersolutions.com/.../2011/09/LabTest-Weatherford-SCALING.pdf · 1.3 Weatherford Scaling Tests Date: 2005 Country: US

Weatherford International Inc. Clearwell Scale Inhibition Research Study

Hycal File #: N901RE (2005)

2

4. See “Discussion” section for a detailed description of the experimental sequence. 5. The manufacturers also claim that the unit can inhibit corrosion and bacteria. It is

recommended that a separate study be commissioned to investigate these claims. 6. We recommend that the Clearwell Hydropath unit be field tested to verify the laboratory

results.

Page 8: Lab Tests 1.3 Weatherford Scaling Tests - a Beseth LPCjerseywatersolutions.com/.../2011/09/LabTest-Weatherford-SCALING.pdf · 1.3 Weatherford Scaling Tests Date: 2005 Country: US

Weatherford International Inc. Clearwell Scale Inhibition Research Study

Hycal File #: N901RE (2005)

3

DISCUSSION

Test 1: Dynamic Tube Block Test Using ⅛” Tubing Coils/Barium Sulfate Scaling Brines

Test 1A: Untreated

Test 1 was performed at 50°C using the following apparatus:

Set-up Outside Oven Set-up in Oven

Page 9: Lab Tests 1.3 Weatherford Scaling Tests - a Beseth LPCjerseywatersolutions.com/.../2011/09/LabTest-Weatherford-SCALING.pdf · 1.3 Weatherford Scaling Tests Date: 2005 Country: US

Weatherford International Inc. Clearwell Scale Inhibition Research Study

Hycal File #: N901RE (2005)

4

Test 1A was performed using a heated injection coil of each incompatible brine (see

Appendix A for compositions) into a mixing zone followed by a ⅛ “ diameter heated tube block

coil. Pressure differential was measured across the tube block coil to monitor the effect as scale

formed to block the tube. Another coil was set up outside the oven, downstream of the first coil.

Pressure differential was also monitored on the second coil. The entire system was calibrated

with de-ionized water to obtain a baseline pressure differential. The baseline pressure

differential across the entire system was 0.2 psig.

Each brine was housed in a large capacity transfer vessel and injected using a positive

displacement pump. The brines were injected simultaneously into individual heated injection

coils and mixed at a junction just upstream of the heated tube block coil. The flow rates used

were 50 mL/hour for each brine, for a combined rate of 100 mL/hour. This rate is approximately

equivalent to 2 bbl/day of flow through a 2” diameter pipe. This is considered a very low flow

rate.

The first test was not treated with the Hydropath unit and pressure build-up was observed

in seven minutes, resulting in plugging of the system with barium sulfate scale (see pressure

profile of the upstream heated coil below). It should be noted that the test was attempted twice.

There was a packed static mixer in-line initially which plugged. The static mixer was removed

and the test was restarted. It took a total of 1100 psig pressure using distilled water to flow

through the plug once it was established.

Weatherford TB Test - Coil1/dP2 - Feb4/05 - Unprotected System

020406080

100120140160180200

14:00 15:00 16:00 17:00

Time

Pres

sure

(psi

g) (3) Pump stoped from 14:55 to 15:25 static mixer removed

(2) Test started at 14:12(5) Pump re-started

at 15:25

Page 10: Lab Tests 1.3 Weatherford Scaling Tests - a Beseth LPCjerseywatersolutions.com/.../2011/09/LabTest-Weatherford-SCALING.pdf · 1.3 Weatherford Scaling Tests Date: 2005 Country: US

Weatherford International Inc. Clearwell Scale Inhibition Research Study

Hycal File #: N901RE (2005)

5

Test 1B: Hydropath Treated System

This test was run identically to the untreated test with the exception that the Clearwell

Hydropath unit was placed in line between the tube block coil inside the oven and the tube block

coil outside the oven (see photo below).

The results of this experiment showed that pressure began building after 45 minutes of

flow. This pressure build-up continued for another 90 minutes. The system was opened at the

mixing junction to remove build-up of precipitate. The flow continued for a period of time until

plugging was observed. The plug broke free at approximately 100 psig and pressure began

building until the plug broke free again. This cycle continued for an hour. The Hydropath unit

was turned off and flow continued to see if the scale would form and plug the system off

completely. This did not occur after 90 minutes (see pressure profile below).

Weatherford TB Test - Coil1/dP2 - Feb5/05 - Protected System

0

20

40

60

80

100

120

140

160

180

200

9:00 10:00 11:00 12:00 13:00 14:00 15:00

Time

Pres

sure

(Psi

g)

(2) Pump started at 9:37

(3) Shut in at 11:18 to clear first foot of coil1

Turn off Clearw ell instrument at 13:22

(4) Pump re-started at 11:23

Page 11: Lab Tests 1.3 Weatherford Scaling Tests - a Beseth LPCjerseywatersolutions.com/.../2011/09/LabTest-Weatherford-SCALING.pdf · 1.3 Weatherford Scaling Tests Date: 2005 Country: US

Weatherford International Inc. Clearwell Scale Inhibition Research Study

Hycal File #: N901RE (2005)

6

The system was shut-in with the Hydropath unit turned off for 36 hours and then

restarted. This time the system plugged off completely. The conclusions that can be drawn from

this effect are that the entire flow loop, including the injection brines, were treated and resulted

in the seed crystal being formed. When the unit was first shut off, scale did not form due to a

lingering effect from the treatment. Only when the system was shut off for 36 hours was the

scale able to form as the seed crystals were no longer available in the system.

Weatherford TB Test - Coil1/dP2 - Feb7/05 - Unprotected System

0

100

200

300

400

500

600

700

800

900

1000

3:00 4:00 5:00 6:00 7:00 8:00 9:00 10:00 11:00 12:00 13:00

Time

Pres

sure

(psi

g)

Test re-started at 3:39

pump stoped from 5:07 to 7:57

Test 2: ¼” Tube Block Test Using Barium Sulfate Scaling Brines

Test 2A: Untreated with ¼” Tubing

This test was devised to the flow through a larger bore tubing so that the large seed

crystals could remain in suspension and flow through the system rather than plug off due to

settling in restrictions. The apparatus was exactly the same as the previous experiment with the

exception of the tube block coils and downstream lines which were all ¼” tubing rather than ⅛”.

Also, an observation coupon was placed in line just below the mixing junction so we could

observe the formation of scale during flow. The thought was that we could observe scale in the

untreated test and see no scale in the subsequent treated test. Below is a photograph of the

observation tubing in line. The tubing was machined by cutting a window using EDM

techniques.

Page 12: Lab Tests 1.3 Weatherford Scaling Tests - a Beseth LPCjerseywatersolutions.com/.../2011/09/LabTest-Weatherford-SCALING.pdf · 1.3 Weatherford Scaling Tests Date: 2005 Country: US

Weatherford International Inc. Clearwell Scale Inhibition Research Study

Hycal File #: N901RE (2005)

7

Observation Window In Line Close-up of Observation Window

This experiment showed pressure build-up after only 45 minutes of flow. This resulted in

the observation window plugging up with scale and precipitate in approximately three hours.

Flow was continued for 10 hours (see pressure profile below).

Weatherford TB Test - 1/4 Inch Tube - Feb14/15 - Unprotected System

0

500

1000

1500

2000

2500

0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00 10:00 11:00 12:00 13:00

Time (hrs)

Pres

sure

(psi

g)

Photo of Plugged Tubing

Precipitate in Window

Page 13: Lab Tests 1.3 Weatherford Scaling Tests - a Beseth LPCjerseywatersolutions.com/.../2011/09/LabTest-Weatherford-SCALING.pdf · 1.3 Weatherford Scaling Tests Date: 2005 Country: US

Weatherford International Inc. Clearwell Scale Inhibition Research Study

Hycal File #: N901RE (2005)

8

Test 2B: Treated with ¼” Tubing

The test was repeated with the Clearwell Hydropath unit in-line as in Test 1B with ⅛”

tubing, with the exception that ¼” diameter tubing was used. This time we observed similar

behaviour to the untreated test with a delay of about two hours. The system still plugged but it

was determined that the plugging was due more to the precipitation of solids because of low flow

rates and not the scaling of the tube walls (see comparison pressure profile below).

Weatherford TB Test - 1/4 Inch Tube - Pressure Profile

0

500

1000

1500

2000

2500

0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00 10:00 11:00 12:00 13:00 14:00

Time (hrs)

Pres

sure

(psi

g)

Unprotected

Protected

Test 3: ¼” Tube Block Test at High Flow Rates Using Incompatible Barium Sulfate and Calcium Carbonate Brines

Test 3A: Untreated System

This test was designed to incorporate the large diameter tubing coupled with a higher

flow rate to determine if settling in the system is a result of scaling or low flow rate. Also, the

brine was changed to include a calcium carbonate component in addition to the barium sulfate

scale used previously. The visual window was in place in this test.

The flow rate was increased to 300 mL per hour on each of the two brines plus a 3000

mL/hour flow of distilled water for a total flow rate of 3600 mL/hour. This is equivalent to

approximately 70 bbl/day of flow through a 2” diameter pipe.

There was no pressure across the system to speak of (less than 1 psig). This indicated that

there was no plugging due to settling. The flow continued for a three-hour period when it

became obvious from visual observation in our windowed coupon that scale precipitation had

occurred. The system was dismantled and severe scale build-up on the walls of the tubing and in

Page 14: Lab Tests 1.3 Weatherford Scaling Tests - a Beseth LPCjerseywatersolutions.com/.../2011/09/LabTest-Weatherford-SCALING.pdf · 1.3 Weatherford Scaling Tests Date: 2005 Country: US

Weatherford International Inc. Clearwell Scale Inhibition Research Study

Hycal File #: N901RE (2005)

9

the injection end was observed (see photographs below). Once the scale had dried, it required

mechanical scraping to remove.

Injection End of Tubing Scale Build-up in Tubing

Page 15: Lab Tests 1.3 Weatherford Scaling Tests - a Beseth LPCjerseywatersolutions.com/.../2011/09/LabTest-Weatherford-SCALING.pdf · 1.3 Weatherford Scaling Tests Date: 2005 Country: US

Weatherford International Inc. Clearwell Scale Inhibition Research Study

Hycal File #: N901RE (2005)

10

Test 3B: ¼” High Flow Rate Treated with Hydropath Unit

The test was repeated with the Clearwell Hydropath unit in line. The flow was initiated

over a three-hour period to replicate the untreated test. Once again, there was very little pressure

differential even at the high flow rates. The test was discontinued after three hours and the

windowed test coupon was removed and dismantled. The difference in the injection end of the

tube and the pipe itself was dramatic. When the tubing was still wet, there did not appear to be

any residue or scale formation. Once the tubing dried, there was a thin film of precipitate but it

was easily brushed off, indicating that crystals were settling out of the brine film rather than

scaling.

Comparison of Untreated Tube (right) Untreated Tube (left) to Treated Tube (left) Treated Tube (right)

It is obvious from these photographs that tubing treated with the Clearwell Hydropath

unit is cleaner than the untreated tubing.

Page 16: Lab Tests 1.3 Weatherford Scaling Tests - a Beseth LPCjerseywatersolutions.com/.../2011/09/LabTest-Weatherford-SCALING.pdf · 1.3 Weatherford Scaling Tests Date: 2005 Country: US

Weatherford International Inc. Clearwell Scale Inhibition Research Study

Hycal File #: N901RE (2005)

11

DESCRIPTION OF EQUIPMENT

Pressure Measurement

Pressure differential is monitored using Yokogawa pressure transducers. The transducers

are mounted directly across the core and measure the pressure differential between the injection

and production ends. The pressure transducers have sensitivities ranging from 0 to 2 psig and 0

to 4000 psig and are rated as accurate to 0.01% of the full-scale value. The appropriate

transducer size is selected based upon the expected permeability and associated range of

accompanying differential pressures for a given core sample. The signal from the pressure

transducer appears on a multi-channel digital terminal from which the test operator records

pressure readings during the displacement processes. The signal can also be downloaded to a

computerized continuing data acquisition system for long-term runs.

Temperature Control

The core holder and associated injection fluids are contained in a temperature controlled

air bath to simulate reservoir temperature. The oven contains a circulating air system to

eliminate internal temperature gradients and can control at temperatures from 20 to 200°C with a

rated accuracy of ±1°C.

Page 17: Lab Tests 1.3 Weatherford Scaling Tests - a Beseth LPCjerseywatersolutions.com/.../2011/09/LabTest-Weatherford-SCALING.pdf · 1.3 Weatherford Scaling Tests Date: 2005 Country: US

Weatherford International Inc. Clearwell Scale Inhibition Research Study

Hycal File #: N901RE (2005)

APPENDIX A

Brine Compositions

Page 18: Lab Tests 1.3 Weatherford Scaling Tests - a Beseth LPCjerseywatersolutions.com/.../2011/09/LabTest-Weatherford-SCALING.pdf · 1.3 Weatherford Scaling Tests Date: 2005 Country: US

Weatherford International Inc. Clearwell Scale Inhibition Research Study

Hycal File #: N901RE (2005)

APPENDIX B

Clearwell Technical Data