Order by phone 01342 826836 Order on-line www.ecomcat.co.uk Order by fax 01342 826771 Website www.jencons.co.uk Pumps Introduction Take a look at our latest products on www.ecomcat.co.uk 747 Introduction to Vacuum Pumps Vacuum pumps are designed to pump air or gases at pressures below atmospheric pressure. Working at below atmospheric pressure facilitates many tasks and research activities in laboratories. These range from simple filtration to complex distillation and many others. Due to their high flow, deep vacuum capability oil-sealed rotary vane pumps have traditionally been very popular in laboratories as they are capable of handling most pumping requirements. However, due to the fact that vapour will condense in the pump, careful selection of traps, accessories and diligent maintenance is required to ensure trouble-free use. Not all tasks or experiments within the laboratory need high flow and deep vacuum and there are alternative pumping technologies that may be more suitable. Please talk to our Technical Office on 01342 826836 if you require assistance. Oil sealed rotary vane pumps Best suited to applications that require high flow rates and pressures below 1 mbar. Traps and accessories are always required. Talk to our Technical Office if you require assistance. Diaphragm pumps These are oil-free pumping mechanisms available in two forms, one for pumping air and one for pumping chemicals. A typical use of a chemical version would be for rotary evaporation. Piston pumps These are oil-free pumping mechanisms that generally have a higher compression ratio than diaphragm pumps, and provide good flow characteristic when used in such applications as filtration, cell harvesting and vacuum oven drying. Not suitable where aggressive vapours or solvents are involved. Scroll pumps A sophisticated oil-free design that gives high flow rates and deep vacuum of the same order as rotary vane pumps. Your application may require the use of a chemical trap. Safety & Health Please consult your Safety Officer regarding the location of your pump and the management of exhaust fumes, especially if handling aggressive chemicals. Pump selection - our rule of thumb guide for you. If you are in any doubt please contact our Technical Office on 01342 826836 for assistance. 1. Select appropriate approximate vacuum for the application 2. Is chemical resistance required (yes or no)? 3. Select flow rate if appropriate. Approx flow rate should be 1–2 times the volume to be evacuated (litres per min) except for filtration, where there the system is not gas tight, use x4. Examples: a. Rotary evaporation of 5L flask plus condenser plus tubing (probable 12L in total), therefore =12x2=24L/min pump flow rate: b. Vacuum oven of 50L capacity 50x2=100 L/min pump flow rate: c. Filtration of 4x1L flasks on manifold plus tubing (probable 5L in total), therefore 5x4=20L/min pump flow rate. 4. Do not ignore features for ease of handling i.e. catchpot, gauge etc 5. Add accessories to increase pump life Application Approx vacuum required Notes Filtration 100~300 mbar ———— Desiccation 100~300 mbar ———— Aspiration 100~300 mbar ———— Cell harvesting 100~300 mbar ———— Rotary evaporators 10 mbar 80% solvents Rotary evaporators 2 mbar 95%+ solvents Gel dryers 50 mbar Too deep vacuum or too high flow rate cracks gels Centrifugal evaporators 10 mbar 80% solvents Centrifugal evaporators 2 mbar 95%+ solvents Freeze dryers 0.1 mbar ———— Vacuum manifolds 2 mbar ———— Vacuum ovens 10 mbar ———— Glove boxes 10 mbar ———— Transfer chambers 10 mbar ———— Bigger is not better as too large a vacuum pump tends to increase the likelihood of condensable vapours bypassing the cold trap and migrating into vacuum pump oil. For instance, a -55°C system condenser will not condense out Acetonitrile vapour causing vapour to condense in oil. Welch Rietschle Thomas Rotary Vane Pump Edwards Scroll Pump KNF Mini Pumps Vacuubrand Diaphragm Pump Ilmvac Diaphragm Pump

Upload: others

Post on 14-Mar-2020

12 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

PumpsIntroduction

Take a look at our latest products on www.ecomcat.co.uk 747

Introduction to Vacuum PumpsVacuum pumps are designed to pump air or gases at pressures below atmospheric pressure. Working atbelow atmospheric pressure facilitates many tasks and research activities in laboratories. These rangefrom simple filtration to complex distillation and many others.

Due to their high flow, deep vacuum capability oil-sealed rotary vane pumps have traditionally been verypopular in laboratories as they are capable of handling most pumping requirements. However, due to thefact that vapour will condense in the pump, careful selection of traps, accessories and diligentmaintenance is required to ensure trouble-free use.

Not all tasks or experiments within the laboratory need high flow and deep vacuum and there arealternative pumping technologies that may be more suitable. Please talk to our Technical Office on01342 826836 if you require assistance.

Oil sealed rotary vane pumpsBest suited to applications that require high flow rates and pressures below 1 mbar. Traps and accessoriesare always required. Talk to our Technical Office if you require assistance.

Diaphragm pumpsThese are oil-free pumping mechanisms available in two forms, one for pumping air and one forpumping chemicals. A typical use of a chemical version would be for rotary evaporation.

Piston pumpsThese are oil-free pumping mechanisms that generally have a higher compression ratio than diaphragmpumps, and provide good flow characteristic when used in such applications as filtration, cell harvestingand vacuum oven drying. Not suitable where aggressive vapours or solvents are involved.

Scroll pumpsA sophisticated oil-free design that gives high flow rates and deep vacuum of the same order as rotaryvane pumps. Your application may require the use of a chemical trap.

Safety & HealthPlease consult your Safety Officer regarding the location of your pump and the management of exhaustfumes, especially if handling aggressive chemicals.

Pump selection - our rule of thumb guide for you. If you are in any doubt please contact our TechnicalOffice on 01342 826836 for assistance.

1. Select appropriate approximate vacuum for the application

2. Is chemical resistance required (yes or no)?

3. Select flow rate if appropriate. Approx flow rate should be 1–2 times the volume to be evacuated (litres per min) except for filtration, where there the system is not gas tight, use x4.Examples: a. Rotary evaporation of 5L flask plus condenser plus tubing (probable 12L in total),

therefore =12x2=24L/min pump flow rate:b. Vacuum oven of 50L capacity 50x2=100 L/min pump flow rate: c. Filtration of 4x1L flasks on manifold plus tubing (probable 5L in total), therefore

5x4=20L/min pump flow rate.

4. Do not ignore features for ease of handling i.e. catchpot, gauge etc

5. Add accessories to increase pump life

Application Approx vacuum required Notes Filtration 100~300 mbar ————Desiccation 100~300 mbar ————Aspiration 100~300 mbar ————Cell harvesting 100~300 mbar ————Rotary evaporators 10 mbar 80% solventsRotary evaporators 2 mbar 95%+ solventsGel dryers 50 mbar Too deep vacuum or too high flow rate cracks gelsCentrifugal evaporators 10 mbar 80% solventsCentrifugal evaporators 2 mbar 95%+ solventsFreeze dryers 0.1 mbar ————Vacuum manifolds 2 mbar ————Vacuum ovens 10 mbar ————Glove boxes 10 mbar ————Transfer chambers 10 mbar ————

Bigger is not better as too large a vacuum pump tends to increase the likelihood of condensable vapours bypassingthe cold trap and migrating into vacuum pump oil. For instance, a -55°C system condenser will not condense outAcetonitrile vapour causing vapour to condense in oil.

Welch RietschleThomas RotaryVane Pump

Edwards Scroll Pump

KNF Mini Pumps

Vacuubrand Diaphragm Pump

Ilmvac Diaphragm Pump

Page 2: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

Pumps

748 Take a look at our latest products on www.ecomcat.co.uk

521-003 Mityvac, Hand-operated Vacuum PumpsHand-held, durable vacuum pumps. Quick and easy to use, with only one hand required to operate andrelease vacuum. External vacuum release valve eliminates need to disengage pump from the line. Nozzlefits standard 6mm i.d. tubing. Both models have a pump rate of 16cm3/stroke and attain a vacuum of upto 409cm3 of mercury in a few seconds. Models have PVC body.

Cat. No. Description Price

521-003 Standard Mityvac vacuum pump with gauge POA

521-004 Standard Mityvac vacuum pump without gauge POA

Traditional Water Jet PumpMade from a modern non-flammable plastic material that has better corrosion resistance than stainlesssteel. It is resistant to a broad range of solvents, mineral and organic acids and alkalis, with very fewexceptions.

Cat. No. Description Price

520-003 Traditional water jet pump POA

Azlon, Water Jet PumpA high performance, polypropylene water jet pump. The side arm tapers from 7 to 12mm.

■ Suitable for most laboratory water pressures ■ Complete with integral non-return valve ■ Will operate effectively (half vacuum) at a flow rate of 7 litres per minute ■ Will produce maximum vacuum of 20-25mmHg at a flow rate of

17 litres per minute ■ Available with or without pressure gauge (0–30mmHg)

Cat. No. Description Inlet tube O.D., mm Price

520-001 Water jet pump 16 POA

520-002 Water jet pump with vacuum gauge 16 POA

Boxer 3300P Compact Air and Gas PumpThe Boxer 3300P is the ideal laboratory pump for a wide range of applications. The high performance tosize ratio of this model offers a useful solution wherever suction or pressure applications are required.

The unit is based on the well established Boxer 3000 range of pumps. It has been specially designed asa flat package to compliment any laboratory shelf, and can be operated in any orientation.

The pump operates on 12V DC and being a low voltage pump, is safe to operate in most laboratoryenvironments. The unit is supplied with a switch mode power supply. This power supply can be used inany supply voltage from 110V to 240V. Air flow can be adjusted via the selectable voltage switch on theremote power supply.

The 3300P pump can be easily fitted with the filter and silencer which are offered as economical, semi-disposable accessories.

■ Contamination- and metal-free path ■ Wetted parts manufactured in polypropylene and nitrile ■ Maintenance free ■ Safe, low voltage supply (12V DC) ■ Quiet operation ■ Flow control via selectable supply voltage

SpecificationMaximum flow rate, m3/hr (L/min) 1.2 (20)Maximum vacuum, mbar 400Maximum pressure, mbar 650Dimensions (hxwxd), mm 61x155x222Weight (including power supply), kg 1.7Electrics 230V AC to 110V AC

Cat. No. Description Price

521-019 Boxer 3300P Compact air and gas pump supplied with POApower adaptor and a range of plugs

521-020 Air filter and silencer POA

520-003

520-002 520-001

520-002

521-019 shown with 521-020New

Page 3: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

PumpsCharles Austen

Take a look at our latest products on www.ecomcat.co.uk 749

Capex 8C Diaphragm Vacuum Pump/CompressorThe Capex 8C is ideal for continuous duty as either a vacuum pump or compressor. It has a compact yetrugged aluminium case with a flush-folding carry handle and built in cable tidy. It incorporates unique “T-slot” rails for quick and easy mounting of retrofittable accessories such as collection flasks and vapour traps.

■ Portable with flush-folding carry handle■ Suitable for applications such as vacuum and pressure assisted filtration and sampling

SpecificationFlow rate, m3/h (L/min) 0.48 (8.0)Maximum vacuum, mbar 240Maximum pressure, bar 2.0Dimensions (hxwxl), mm 214x137x282*Weight, kg 3.75

Cat. No. Description Price

521-061 Capex 8C diaphragm vacuum pump/compressor POA

* includes the cable tidy and connectors

Dymax 5, Diaphragm Vacuum Pump/CompressorDesigned and manufactured with the laboratory user in mind, the Dymax 5 incorporates low noise levels,splash proof switch and plug-in mains lead. It is ideal for supplying air in microbiology experiments andfor sampling a wide range of gases.

Vacuum Tweezer Option Supplied with a hand piece and set of suction probes, this accessory is ideal for handling a small delicateobject as fine as gold leaf. The integral, washable filter also makes it useful for precision cleaning.

SpecificationMaximum free flow rate, m3/h (L/min) 0.3 (5.0) Dimensions (hxwxl), mm 125x151x210Maximum vacuum, mbar 500 Weight, kg 2.1Maximum pressure, bar 0.8 Standards IEC 1010Speed, rpm 2800

Cat. No. Description Price

521-063 Dymax 5 cased pump POA

521-064 Dymax 5 cased pump with vacuum tweezer kit POA

Innovac, Chemically Resistant Diaphragm Vacuum PumpsThis range of dry vacuum pumps offer class leading performance with chemical resistance to virtuallyall corrosive gases and solvent vapours. Housed in a tough alloy case featuring unique “T-slot” rails forquick easy mounting of all necessary attachments such as vacuum gauges, vapour traps or condensers.The flush-folding carry handle provides stowage for the pump’s service tool and conceals a handy hourmeter, which can monitor process times.

SpecificationModel Innovac 20 Innovac 40Maximum free flow rate, m3/h (L/min) 1.2 (20) 2.3 (38)Maximum vacuum, mbar 8.0 8.0Maximum pressure, bar 1.0 1.0Speed, rpm 1400 1400Dimensions (hxwxl), mm 214x136x331 214x136x393Weight, kg 8.5 11.6Standards IEC 1010 IEC 1010

Cat. No. Description Price

521-102 Innovac 20 chemically resistant vacuum pump POA

521-103 Innovac 40 chemically resistant vacuum pump POA

■ Contamination-free vacuum■ Advanced reliability with exceptionally long

running life■ Fully corrosion resistant with all wetted parts

constructed entirely from PTFE and Kemrez®

■ Applications include benchtop use for filtration, rotary evaporation, gel drying and vacuum distillation

■ Vacuum down to 8mbar

■ Contamination-free pumping of air and gas■ Ideal for continuous duty month after month■ Easy to maintain

■ Up to 5.0L/min flow■ Vacuum down to 500mbar■ Quiet operation

521-061

521-103 521-102

New

521-063 New

521-064 New

Page 4: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukFluid Aspiration

Pumps

750 Take a look at our latest products on www.ecomcat.co.uk

Ilmvac, BIOVAC 102, Fluid Aspiration SystemThe new BIOVAC 102 is a portable vacuum aspiration system with integrated, chemically resistant,diaphragm pump that is ideally suited for the safe aspiration of biological supernatants as well asremnants of chemical or medical experiments. All elements of the liquid pathway are chemically inert,allowing a wide range of reagents to be used and for sterilisation by Virkon.

It is easy to remove small amounts of excess liquids from object slides, petri dishes, well plates etc,through various kinds of pipettes which are inserted into the pipette carrier of the hand piece. The largeintegrated catch pot is isolated automatically, as soon as the maximum filling level is reached.

Between the catch pot and the pump, there is a filter holder in which diaphragm filters of up to 0.22 µm can be inserted allowing bacteria and viruses to be handled safely. The catch pot and thediaphragm pump are connected via fast locking couplings with integral bi-directional isolation valve.The chemically resistant diaphragm pump employed in the BIOVAC has a long life (10,000 runninghours) and can be operated by means of a foot switch.

■ 2-litre autoclavable glass catch-pot ■ Automatically isolates when full ■ Lid with integrated fine filter casing with quick release bayonet joint ■ Bacteriological filter pore size of 0.22 µm ■ Hose connection via quick fit coupling with bi-directional shut-off valve ■ Hand piece with multi option pipette carrier ■ Chemically resistant diaphragm pump operated via a foot switch ■ 2 year warranty and very low servicing costs

BIOVAC 102 - Stand alone fluid aspiration system, ready for use, comprising: Diaphragm pump, glasscatch-pot, hand set, foot switch and carry handle.

Specification Flow rate, m3/hr (L/min ) 12Ultimate pressure, mbar <100Dimensions (wxdxh), mm 330x170x370Weight, kg 8Electrical supply 230V, 50/60Hz

Cat. No. Description Price

521-187 BIOVAC 102 Fluid aspiration system POA

For details on accessories, including maintenance kits, please contact our Technical Office on 01342 826836.

KNF, Liquiport Diaphragm PumpsNew, multi-purpose pumps ideal for aspiration or transferring liquids. The flow rate can be adjusted manually(S models) or remotely (RC models). The standard head material for this pump is chemically resistantpolypropylene (PP). However, for applications using highly aggressive chemicals, the Liquiport pump isavailable with a PVDF or PTFE head. Please contact our Technical Office for details on 01342 826836.

SpecificationsModel NF100 KT.18 S NF1.100 KT.18 RC NF300 KT.18 S NF1.300 KT.18 RCFlow rate, l/min 0.2-1.3 0.2-1.3 0.5-3.0 0.5-3.0Max suction head, mWg 4 4 3 3Max pressure head, mWg 10 60 10 60Dimensions (mm) 130x99x177 130x99x177 160x104x188 160x104x188Weight, kg 1 1 1.5 1.5

Cat. No. Description Price

521-015 NF100 KT.18 S Liquiport diaphragm pump, manual control POA

521-016 NF1.100 KT.18 RC Liquiport diaphragm pump, manual and external control POA

521-017 NF300 KT.18 S Liquiport diaphragm pump, manual control POA

521-018 NF1.300 KT.18 RC Liquiport diaphragm pump, manual and external control POA

■ Flow range from 0.2 to 3l/min ■ Self-priming ■ Can be run dry ■ Minimal maintenance and long life

■ IP65 motor protection class ■ Excellent chemical resistance ■ Very quiet operation ■ Mains supply 100-230V 50/60Hz 1PH

521-187New

521-015New

Page 5: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

PumpsFluid Aspiration

Take a look at our latest products on www.ecomcat.co.uk 751

Vacuubrand, BioChem-VacuuCenter, Fluid Aspiration SystemsSimple, safe and easy to use vacuum aspiration system, specifically designed for fluid aspiration frombulk samples to microplates in chemistry, biochemistry, biology and medicine.Automatically controlled, low maintenance, high performance vacuum pump with condensate catchpoton exhaust provides vacuum automatically on demand for single and multiple workstations, with noneed for foot pedal or start / stop switch. This ready-to-use unit comes complete with an ambidextrous,ergonomically designed hand control, which accepts all common pipettes and tips, and a large 4 litreautoclavable collection bottle (with additional port for second hand control) and biohazard filter. It isalso available without pump (BVC01) for connection to existing vacuum systems.

BVC21 - Stand alone fluid aspiration system, ready for use unit comprising vacuum pump, vacuumcontrol, collection bottle/filter, hand set.

BVC01 - Fluid aspiration system without pump for connection to existing vacuum system

■ High performance vacuum pump (BVC21 only)■ For up to two workstations■ Appropriate chemical resistance■ Large capacity reservoir■ Easy to use

Specifications Model BVC21 BVC01Dimensions (lxwxh), mm 520x300x500 300x250x500Weight, kg 11.0 4.0Electrical supply 230V, 50/60Hz 230V, 50/60Hz

Cat. No. Description Price

521-179 BVC21 Stand alone fluid aspiration system POA

521-180 BVC01 Fluid aspiration system without pump POA

Accessories

Cat. No. Description Price

521-181 Additional hand control with hose POA

521-183 Additional container, 4L autoclavable POA

521-182 Quick coupling for flexible hose connecting hand control and container POA

521-186 Spare hose for hand control, 2m POA

521-184 Spare protection filter with mounting tube POA

521-185 Elbow hose connection for hand control and container POA

Welch Rietschle Thomas, Fluid Aspiration SystemThis dry vacuum aspiration system is specifically designed for fluid aspiration from bulk samples tomicroplates in biochemistry, biology, chemistry and medicine. This ready to run unit is supplied completewith autoclavable collection vessel, footswitch, pipette holder, 1.8m tubing, vacuum regulator and gauge.

SpecificationFlow rate, m3/hr (L/min) 34 (2)Maxiumum vacuum, mbar 560Capacity – plastic autoclavable bottle, ml 1200Tubing required, I.D., mm 6.35Dimensions (wxdxh), mm 375x210x255Weight, kg 4.9

Cat. No. Description Price

691-057 Model 2515 Fluid aspiration system POA

Please note: 100 and 115V versions are available. Please contact our Technical Office on 01342 826836.

For replacement silicone pipette holder and tubing, please contact our Technical Office on 01342 826836.

■ Cost effective ■ Quiet operation ■ Accepts common pipette tips

521-179

521-180

691-057

Page 6: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukFluid Aspiration

Pumps

752 Take a look at our latest products on www.ecomcat.co.uk

521-400 UNIJET Aspirator PumpsUseful for centrifugal concentrators, gel dryers, vacuum ovens, filtration etc. A UNIJET aspirator pump ismore sturdy and needs much less maintenance than an oil-lubricated vacuum pump. Harmful aerosolslike acids, alcohol etc. are absorbed in the bath water, which can be buffered if necessary.

All UNIJET models feature:

■ An energy saving and environmentally safe vacuum system■ A strong vacuum created by pumping water through two or four Teflon® Venturi jets■ Teflon® jets offer excellent chemical resistance ■ Extremely quiet operation ■ No oil needed■ Analogue vacuum gauge■ Easy to clean and drain

UNIJET I Non Refrigerated Aspirator Pumps The UNIJET I aspirator pumps have a bath volume of 8 litres and are available with vacuum pressurecontrol and 4 jet pumps, or without vacuum pressure control and 2 jet pumps.

SpecificationsModel UNIJET I, 2 jets UNIJET I, 4 jets

without vacuum pressure control with vacuum pressure controlBath material clear plastic plasticAir flow, L/min 28 35Bath volume, litres 8 8Dimensions (wxdxh), mm 250x370x400 250x370x400Weight, kg 8.5 8.5Power consumption, W 160 160

Cat. No. Description Price

521-400 UNIJET I aspiration pump with 2 jets without vacuum pressure control. POASupplied with non refrigerated water bath, analogue vacuum gauge.

521-401 UNIJET I aspiration pump with 4 jets with vacuum pressure control. POASupplied with non refrigerated water bath, analogue vacuum gauge.

UNIJET II and UNIJET IV Refrigerated Aspirator Pumps The UNIJET II and IV pumps are designed for absorbing larger quantities of solvents, especially incombination with rotary evaporators. They have a built-in cooling system to chill the water bath and toeliminate normal heat-up caused by pump operation. Cold water has a high capacity to absorb aerosolswhich are released by the samples. The vacuum that is generated depends on the temperature of the water:The lower the temperature, the higher the vacuum; at +4°C a vacuum pressure of ca. 4mbar is attainable.

The UNIJET II and IV aspirator pumps have a bath volume of 10 litres and are available with vacuumpressure control and 4 jet pumps (UNIJET IV) or without vacuum pressure control and 2 jet pumps (UNIJETII). Both models feature Fuzzy Logic functionality.

SpecificationsModel UNIJET II, 2 jets without vacuum UNIJET IV, 4 jets with vacuum

pressure control pressure controlBath material stainless steel stainless steelAir flow, L/min 35 95Residual pressure @4°C, mbar 4 4Bath volume, litres 10 10Dimensions (wxdxh), mm 326x438x638 326x438x638Weight, kg 38 38Power consumption, W 500 500

Cat. No. Description Price

521-402 UNIJET II aspiration pump with 2 jets without vacuum pressure control. POASupplied with 10 litre refrigerated water bath, digital display for temperature, vacuum gauge and dual vacuum pipe.

521-403 UNIJET IV aspiration pump with 4 jets with vacuum pressure control. POASupplied with 10 litre refrigerated water bath, digital display for temperature, vacuum gauge and dual vacuum pipe.

New

521-403New

Page 7: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

PumpsWelch Rietschle Thomas

Take a look at our latest products on www.ecomcat.co.uk 753

691-056

691-041GelMaster™ Gel Dryer Vacuum SystemThe Welch Rietschle Thomas GelMaster™ is a patented vacuum system with roomtemperature vapour trap and vacuum system integrated into a single, high-efficiency,low-maintenance unit.

The vapour trap reduces the overall vapour load enabling a compact, high-efficiencydiaphragm pump to be the primary vacuum force.

Trapped fluids accumulate in the collector over 10 to 15 gel drying runs (and it is justas efficient on the last run as on the first). When the fluid reaches the red zone in thefluid-level sight glass, simply open a valve and drain the collected fluid. The system isthen ready to dry more gels. The trapping fluid can then be re-used over and overagain, since it does not mix with the condensate.

The diaphragm pump delivers a powerful, non-fluctuating vacuum for fast,smooth drying.

■ Complete system for gel dryers ■ Controlled evaporation rate to ensure crack-free gels ■ Fast and quiet operation

SpecificationsCondensed vapour capacity, litres 1.5Inlet port 10mm ID hose nippleDimensions (wxdxh), mm 286x394x365Weight, kg 15.2

Cat. No. Description Price

691-041 GelMaster™ gel dryer vacuum system, supplied complete POAand ready-to-use with 1.7m of PVC vacuum tubing, in-line stopcock, hose clamps, detachable power cord and 1 litre of trapping medium

Please note: 100 and 115V versions are available. Please contact our Technical Office on01342 826836.

High Performance, Dry Vacuum General Utility PumpsWelch Rietschle Thomas dry piston pumps are ideal replacements for oil sealed pumpsfor general utility applications such as drying and degassing. These compact pumpsare built for extended service life and are supplied with accessories for ease of use.Carrying handle, suction-cup feet, power cord, ‘on/ off’ switch, regulator, gauge andtrap are included. Suitable for use with:

■ Vacuum ovens■ Transfer lines ■ Glove box transfer chambers

SpecificationsModel 2561 2581Flow rate, m3/hr (L/min) 3.0 (50) 4.9 (83)Ultimate vacuum, mbar 4 4Maximum pressure, mbar 6.7 6.7Motor, HP 1⁄3

1⁄3

Tubing required, I.D., mm 10 10Dimensions (lxwxh), mm 439x165x267 432x191x305Weight, kg 9.7 13.4

Cat. No. 691-055 691-056

Price POA POA

Please note: 100 and 115V versions are available. Please contact our Technical Office on 01342826836.

Page 8: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukWelch Rietschle Thomas

Pumps

754 Take a look at our latest products on www.ecomcat.co.uk

691-048 Automated Self-Cleaning, Dry Vacuum System for RotaryEvaporation, Concentration, Distillation and Similar ApplicationsThis self-cleaning dry vacuum system gives an oil-free vacuum using a two-stage diaphragm pump. WithPTFE used on all wetted surfaces, including the diaphragm, the pump is built to resist aggressive chemicalvapours and has an extended service life.

■ Oil-free system for rotary evaporators ■ Vacuum regulator ■ Resistant to corrosion with PTFE construction ■ Self-cleaning purge extends pump life but does not interfere with vacuum ■ Patented valve design ensures fast, effective pumping ■ Vent switch to minimise vapour condensation in pump

The glass inlet separator helps protect the pump from ingesting liquids or particles. The gas ballast orvent switch acts to minimise vapour condensation when pumping heavy vapour loads. Vacuumregulation is accomplished with an adjustable bleed valve.

Any particles, water or condensed vapour that may have been ingested into the pump are purged whenit is shut off. The self-cleaning purge automatically turns on for 2 minutes after turning off the pump. Anexhaust separator catches any liquid or particles during the purge cycle.

SpecificationsModel 2023 2027Vacuum, mbar 10 2Flow rate, m3/hr (L/min) 1.62 (27) 1.62 (27)Gauge dial digitalMotor, HP 1⁄5

1⁄5

Tubing required I.D., mm 7 7Dimensions (lxwxh), mm 324x203x292 324x203x292Weight, kg 12.7 12.7

Cat. No. Description Price

691-048 Model 2023 automated dry vacuum system supplied with power cable and POAoperating manual with applications advice

691-049 Model 2027 automated dry vacuum system supplied with power cable and POAoperating manual with applications advice

Self-Draining Teflon Pumps for Rotary Evaporation,Concentration and DistillationThese two stage oil-free, fully corrosion resistant pumps are suitable for demanding applicationsincluding working with TFA, HCI, formic and acetic acid. A patented high flow valve system allows thesepumps to supply fast, repeatable vacuum.

SpecificationsModel 2021 2031Ultimate vacuum, mbar 2.7 2.7Flow rate, m3/h (L/min) 1.1 (18) 1.6 (27)Motor, HP 1⁄5

1⁄5

Tubing required, I.D., mm 7 7Dimensions (lxwxd), mm 254x254x175 254x254x175Weight, kg 9.1 9.1

Cat. No. Description Price

691-050 Model 2021 self-draining teflon pump supplied with power cable and silencer POA

691-051 Model 2031 self-draining teflon pump supplied with power cable and silencer POA

Please note: 100 and 115V versions are available. Please contact our Technical Office on 01342 826836.

■ Oil-free■ High flow valve technology

■ Fast, repeatable vacuum ■ Quiet operation

New

691-049New

691-051New

Page 9: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

PumpsWelch Rietschle Thomas

Take a look at our latest products on www.ecomcat.co.uk 755

691-042Dry, Dual-Function Vacuum and Pressure Pump for Filtration and AspirationWelch Rietschle Thomas dry-piston vacuum pumps are ideal for air sampling, pressure/ vacuum filtration,water aeration, flame photometers etc. The units are built for continuous-duty operation with low noiseand a service life that exceeds diaphragm pumps.

Regulators and gauges make it easy to meet your vacuum and pressure requirements. Discharge air isfiltered and noise is muffled with a filter. A moisture trap keeps water from being accidentally drawninto the unit.

All wetted aluminium parts are treated for corrosion protection from moisture. All other wetted parts arestainless steel. The motor is thermally protected. Carrying handle, suction-cup feet, power cord, ‘on/off’ switch, regulator, gauges and traps are included.

NB; These pumps are not recommended for pumping acid, base or organic vapours.

SpecificationsModel 2522 2534 2546Flow rate, m3/hr (L/min) 1.1 (18) 1.7 (28) 2.3 (38)Maximum continuous pressure, bar 2 2 2Maximum vacuum, mbar 133 90 80Typical filter funnel capacity 1-2 1-4 1-6Motor, HP 1⁄8

1⁄81⁄8

Tubing required, ID., mm 7 7 7Dimensions (lxwxh), mm 205x224x254 205x224x254 205x224x254Weight, kg 5.3 5.3 5.3

Cat. No. Description Price

691-042 Model 2522 dry dual-function vacuum and pressure pump POA

691-052 Model 2534 dry dual-function vacuum and pressure pump POA

691-053 Model 2546 dry dual-function vacuum and pressure pump POA

Please note: 100 and 115V versions are available. Please contact our Technical Office on 01342 826836.

Dry Vacuum System for Cell HarvestingThe Dry Vacuum System provides high throughput flow which allows up to 256 sample systems to behandled. With high flow at low pressure the system will handle even particularly sticky or viscoussubstances. Carrying handle, suction-cup feet, power cord, ‘on/ off’ switch, regulator, gauge and trap areincluded.

SpecificationsModel 2585 2567Well system 256 96Flow rate, m3/hr (L/min) 10.2 (168) 4.9 (83)Ultimate vacuum, mbar 80 80Maximum pressure, bar 1 1Motor, HP 1⁄3

1⁄3

Tubing required, I.D., mm 10 10Dimensions (lxwxh), mm 282x234x279 150x254x254Weight, kg 11.6 7.5

Cat. No. Description Price

691-039 Model 2585 Dry Vacuum System POA

691-054 Model 2567 Dry Vacuum System POA

Please note: 100 and 115V versions are available. Please contact our Technical Office on 01342 826836.

Aspiration of buffer solutions during cell harvesting is permitted, but do not allow liquids to be ingested into thepump. Not recommended for pumping acid, base, organic vapours or gases.

■ Oil-free pumping technology is virtuallymaintenance-free

■ Compact size takes up little bench space■ Quiet operation

■ Attached inlet trap to prevent accidentalingestion of liquid

■ Vacuum gauge allows verification of vacuum level

■ Pressure regulator ■ Vacuum regulator■ Oil-free system delivers clean air■ Corrosion protection from moisture

■ Continuous-duty operation■ Quiet operation ■ Compact

New

691-054 New

Page 10: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukWelch Rietschle Thomas

Pumps

756 Take a look at our latest products on www.ecomcat.co.uk

691-035

691-047

691-036

691-037

W-Series Rotary Vane Vacuum PumpsThe W-Series pumps from Welch Rietschle Thomas are oil-lubricated, rotary vane high-vacuum pumpssuitable for use with freeze dryers, centrifugal concentrators and vacuum ovens.

Model 8917-80 is supplied with a built-in large capacity acid neutralisation filter which will lead to anextended service interval. The acid neutralisation filter is designed for use with TFA, TFA by-productsand acetonitrile.

■ Cool running - special interstage fan delivers improved seal life, reliability and lengthens the timebetween oil changes

■ Cool surface temperature - maximum 20°C rise above ambient ■ Easy oil-change valve - with a simple turn, spent oil is neatly directed into a beaker for inspection

or a bottle for recycling. A tube can be attached for remote collection. ■ Unibarb hose connections to eliminate need for expensive clamps and flanges ■ Quiet operation ■ Compact ■ Extended service interval for model 8917-80

SpecificationsModel 8907 8912 8917 8917-80Ultimate vacuum gas 1.3x10-4 1.3x10-4 1.3x10-4 1.3x10-4

ballast closed, mbarUltimate vacuum gas 80 60 40 40ballast (fully open), mbarFlow rate, m3/hr (L/min) 3.4 (56) 5.2 (86) 8.4 (138) 8.4 (138)Nominal pumping 3.2 (53) 4.8 (80) 7.6 (125) 7.6 (125)speed, m3/hr (L/min)Motor, HP 1⁄3

1⁄31⁄3

1⁄3

Pump speed, rpm 1425 1425 1425 1425Inlet connection Unibarb Unibarb Unibarb UnibarbTubing required, I.D., mm 11, 20 11, 20 11, 20 11, 20Oil capacity, litres 1.15 1.08 1.38 2.5Noise level , dB(A) <50 <50 <50 <50Surface temperature rise, °C 20 20 20 20Dimensions (wxdxh), mm 165x471x243 165x471x243 165x471x243 292x471x243Weight, kg 18 18 22 24.4

Cat. No. Description Price

691-033 Model 8907 high-vacuum pump supplied with unibarb inlet fitting, POApower cable and 1L oil

691-034 Model 8912 high-vacuum pump supplied with unibarb inlet fitting, POApower cable and 1L oil

691-035 Model 8917 high-vacuum pump supplied with unibarb inlet fitting, POApower cable and 1L oil

691-047 Model 8917C-80 high-vacuum pump supplied as above, but also with POAbuilt-in large capacity acid neutralisation filter

Accessories

691-037 Exhaust oil recycler. Designed for pumping continuously at high pressure for POAprolonged periods

691-036 Exhaust filter. Designed for intermittent deep vacuum use POA

691-043 Dry ice/liquid nitrogen trap POA

691-045 Molecular sieve trap POA

691-046 Replacement filter element for 691-036 POA

691-038 5 litre Directorr Premium vacuum pump oil POA

New

Page 11: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

PumpsEdwards

Take a look at our latest products on www.ecomcat.co.uk 757

520-022

520-022 DETAIL

691-021

691-020

RV Series Rotary Vacuum PumpsThe RV series pumps are unique in their capability to deliver high or low throughputs with high ultimatevacuum, which combined with ultra-low noise levels makes them ideal for a wide range of applicationsand environments. They also feature a fast acting inlet valve to seal the pump for suck-back protection.The pumps are easy to install, use and maintain. All the controls are clearly marked and have large fingergrips for ease of use. Inlet and outlet are both fitted with standard NW25 flanges. Supplied with 1 litreof Ultragrade 19 oil. Power cord is required but not included with the pumps. For Health and Safetyrequirements an oil mist filter is required (see below).

SpecificationsModel RV3 RV5 RV8Pumping speed, m3/h (L/min) 3.3 (55) 5.1 (85) 8.5 (140)Displacement, m3h–1 3.7 5.8 9.7Ultimate vacuum, mbar 2x10–3 2x10–3 2x10–3

Noise, dB(A) 48 48 48Max. water vapourpumping rate gh–1 220 220 220Oil capacity, L 0.7 0.7 0.75 Dimensions (wxdxh), mm 158x430x224 158x430x225 158x470x261Weight, kg 21.6 21.5 26.0

Cat. No. 520-022 520-023 520-024

Price POA POA POA

Accessories

Cat. No. Description Price

520-028 Power cord, IEC socket, 2m long with 3 pin plug POA

520-014 Ultragrade 19 mineral oil, 4L POA

Speedivac 2 Vacuum PumpGeneral purpose single stage laboratory pump. For 220–240V, 50Hz single phase supply. Supplied withUltragrade 19 oil, non-return valve and inlet/outlet nozzles. For Health and Safety requirements an oilmist filter is required.

SpecificationsPumping speed, m3/h (L/min) 2.3 (38)Displacement, m3/h (L/min) 2.7 (45)Ultimate vacuum, mbar

Without gas ballast 1.3x10–1

With gas ballast 6Vacuum inlet, mm 11 or 15 nozzleOutlet, mm 12Oil capacity, L 0.5 Weight, kg 12.5

Cat. No. Description Price

691-021 Speedivac 2, vacuum pump POA

520-014 Ultragrade 19 mineral oil, 4L POA

EMF Series Oil Mist Filters■ Protection from oil mist emissions as required by COSHH and Health and Safety regulations

(EMF filters have 99.999% efficiency)■ Suitable for rotary pumps up to (330L/min)■ Unique odour element to neutralise oily smells■ The white bottom half of the body is translucent, allowing the oil level to be monitored■ For safety, if the oil element becomes blocked, an integral pressure relief valve will open

Cat. No. Description Price

691-020 EMF10, oil mist filter complete with KF25 connections 3⁄4in. BSP to KF25 adaptor, POAcentring ring with ‘O’ ring and clamp. Fits RV3, 5 and 8

691-019 EMF3, oil mist filter supplied complete as above but fits Speedivac 2 POA

Page 12: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukEdwards

Pumps

758 Take a look at our latest products on www.ecomcat.co.uk

XDS and XDS-C Dry Vacuum Scroll PumpsCompletely dry, lubricant-free vacuum pumps with vapour handling. The innovative XDS and XDS-C drypumps were designed by BOC Edwards to provide vacuum totally free of lubricants. Bearings are isolatedfrom the vacuum environment by a patented bearing shield. Uniquely, by using a scroll mechanism thereare no bearings, bearing purges, grease or oil under vacuum. Controllable gas ballast is standard andmakes the XDS and XDS-C suitable for pumping condensed vapours.

These pumps are portable, air-cooled and cost effective. Power consumption is very low and, typically,no other utilities are required. Low vibration and noise levels make them ideal for laboratory use. TheXDS pumps are not supplied with a power cord.

A carefully selected and tested combination of chemically resistant materials makes the XDS-C series idealfor a wide range of laboratory wet chemistry applications.

Typical applications for XDS-C pumps: gel drying, rotary evaporation, centrifugal concentration andother applications where condensable vapour are pumped.

Typical applications for XDS pumps: scanning electron microscopes, ion implanters (beamline and endstations), sputtering, turbomolecular pump backing and general clean pumping applications.

■ Totally dry, lubricant-free vacuum ■ 3-position gas ballast selector - Pumps in excess of 200 gh–1 water vapour■ Ease of maintenance - No oil to buy, change or dispose of, no re-greasing of bearings, no special

tool kits or jigs for service, simple supply voltage selection■ Dual voltage/frequency

SpecificationsModel XDS5 XDS10 XDS5-C XDS10-CDisplacement50Hz, m3/h (L/min) 5.7 (94) 11.3 (186) 5.7 (94) 11.3 (186)60Hz, m3/h (L/min) 6.7 (111) 13.4 (221) 6.7 (111) 13.4 (221)

Peak pumping speed50Hz, m3/h (L/min) 4.8 (94) 9.3 (153) 4.8 (79) 9.3 (153)60Hz, m3/h (L/min) 6.0 (99) 11.1 (183) 6.0 (99) 11.1 (183)

Ultimate vacuum 0.07 0.07 0.9 0.9(total pressure), mbarWater vapour handling, gh-1

gas ballast low/ high flow 70/>200 70/>200 70/>200 70/>200Motor supply voltage50Hz/ 60Hz 1 phase 110 or 220–240V/115–120 or 230–240V (all models)50Hz/ 60Hz 3 phase 200–220 or 380–415V/200–230 or 460V (all models)

Power, kW 0.3 0.3 0.3 0.3Operating temperature, °C (°F) 10 to 40 (50 to 104), (all models)Noise level, dB(A) 55 55 55 55Vibration, mms-1 (rms) <1.5 <1.5 <1.5 <1.5Water vapour handling, gh-1

gas ballast low/ high flow 70/>200 70/>200 70/>200 70/>200Exhaust and inlet connection 25NW 25NW 25NW 25NWDimensions (lxwxh), mm 427x249x288 (all models)Weight, kg 23 24.5 23 24.5

1 phase vacuum pumps 520-034 520-036 520-038 520-040

Price POA POA POA POA

3 phase vacuum pumps 520-035 520-037 520-039 520-041

Price POA POA POA POA

Accessories

Cat. No. Description Price

520-028 Power cord, IEC socket, 2m long with 3 pin plug POA

520-025 Aluminium rifled nozzle POA

520-042 Centring ring with ‘O’ ring POA

520-043 Hinged clamp POA

A new model, the XDS35i is also available, this has a peak pumping speed of 35m3/h. Please contact our TechnicalOffice on 01342 826836 for details.

520-036

520-040

Page 13: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

LABORATORY PUMPS AND SYSTEMS

For more details on these and any other products from KNFlab®

Please contact:

Jencons-PLS Technical Office on 01342 826 836

First class pumps for first class science

WE’VE JUSTMADE HIS DAY!

DELIGHTEDNO PUMPS TO FIX

SHHHHHHH!!!!!!!

Page 14: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukKNF

Pumps

760 Take a look at our latest products on www.ecomcat.co.uk

521-057

521-201

521-206

521-204

521-093

521-029 to 521-031

Mini Vacuum Pumps/CompressorsIdeal for general use around the laboratory/educational establishments.

SpecificationsModel N86 KN.18 N86 KT.18 N811 KN.18 N811 KT.18Flow rate, m3/h (L/min) 0.36 (6) 0.33 (5.5) 0.69 (11.5) 0.69 (11.5)Vacuum, mbar 100 160 240 290Pressure, bar 2.4 2.5 2 2Diaphragm EPDM PTFE coated EPDM PTFE coatedDimensions (wxdxh), mm 90x164x141 90x164x141 90x187x157 90x187x157Weight, kg 1.9 1.9 2.5 2.5

Cat. No. 521-057 521-200 521-201 521-202

Price POA POA POA POA

SpecificationsModel N816.3 KN.18 N816.3 KT.18 N816.1.2 KN.18 N816.1.2 KT.18Flow rate, m3/h (L/min) 0.96 (16) 0.96 (16) 1.8 (30) 1.8 (30)Vacuum, mbar 15 20 100 160Pressure, bar 0.5 0.5 0.5 0.5Diaphragm EPDM PTFE coated EPDM PTFE coatedDimensions (wxdxh), mm 90x361x141 90x361x141 90x361x141 90x361x141Weight, kg 3.95 3.95 3.95 3.95

Cat. No. 521-203 521-204 521-205 521-206

Price POA POA POA POA

Laboport Vacuum PumpsPTFE, corrosion resistant, diaphragm, oil-free The Laboport series provides a powerful alternative to water jet pumps, operating without water. Theytherefore save water and reduce environmental pollution. They also reduce operating costs dramatically.The pumps provide a constant vacuum, independent of water pressure and temperature. With theexception of N840.1.2FT.18 and N842.3FT.18, these pumps are single-head designs.

SpecificationsModel N810 FT.18 N820 FT.18 N840 FT.18 N810.3 FT.18Flow rate, m3/h (L/min) 0.6 (10) 1.2 (20) 2 (34) 0.6 (10)Vacuum, mbar abs ≤100 ≤100 ≤100 ≤8Pressure, bar 1.0 1.0 1.0 1.0Dimensions (wxdxh), mm 256x146x187 268x159x207 297x171x226 281x140x187Weight, kg 5.9 7.1 10.3 6.9

Cat. No. 521-053 521-054 521-055 521-029

Price POA POA POA POA

SpecificationsModel N820.3 FT.18 N840.3 FT.18 N842.3 FT.18 N840.1.2 FT.18Flow rate, m3/h (L/min) 1.2 (20) 2 (34) 2 (34) 3.6 (60)Vacuum, mbar abs ≤8 ≤8 ≤2 ≤90Pressure, bar 1.0 1.0 1.0 1.0Dimensions (wxdxh), mm 312x154x207 341x166x226 341x167x223 341x160x226Weight, kg 9.3 12.6 13.4 12.6

Cat. No. 521-030 521-031 521-093 521-091

Price POA POA POA POA

■ Simple to operate and maintenance free■ Motors run cool, even when running continuously■ Extremely quiet and smooth running■ Contamination free pumping of air, gases

and vapours

■ High tolerance of both vapour and condensate■ Integrated, flush-fitting handle for easy carrying■ Wide range of accessories available including

traps and condenser

■ Compact and portable■ Easy operation■ Maintenance-free

■ Vacuum down to 15mbar■ Flowrate 5.5 to 30L/min■ Chemical resistant (KT versions)

Page 15: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

PumpsKNF

Take a look at our latest products on www.ecomcat.co.uk 761

Self-Drying, Continuous-Cleaning Vacuum PumpsCorrosion resistant, diaphragm, oil-freeKNF’s innovative Laboport Self Drying Diaphragm Vacuum Pumps are ideal for applications wheresaturated vapours are being evacuated. This usually causes liquids to collect in the pump, as encounteredwith vacuum ovens, rotary evaporators and gel dryers. Unless removed from the pump they increaseprocessing time and reduce efficiency and pump life. The Laboport Self Drying Pumps cycle every fewminutes, removing accumulated moisture instantly without disturbing the vacuum process.

The unique self-drying process removes accumulated condensate from the pump and restores efficiencywhilst the pump is operating. During the cycle the drying system solenoid opens, permitting air to enterthe evacuated pump head. As a result of the increase in pressure in the pump head, the inlet valve of thefirst stage pump head closes, thus preserving the vacuum level within the evacuated chamber. Bycontrast, the outlet valve, and both valves of the second stage pump head, open automatically causingcondensation to be expelled at high speed. The solenoid valve closes again and the pump now evacuatesthe chamber at full capacity. The drying operation is precisely controlled by an adjustable electronic timer,and set as required.

KNF Laboport pumps feature chemically resistant materials (e.g. PTFE, FFPM) in contact with the gasstream. There are no metal parts to corrode. KNF’s moulded structural diaphragm and multiport designensure reliable vacuum performance.

SpecificationsModel N820.3 FT.40.18 N840.3 FT.40.18 N842.3 FT.40.18 N860.3 FT.40.18Flow rate, m3/h (L/min)* 1.2 (20) 2 (34) 2 (34) 3.6 (60)Vacuum, mBar abs ≤10 ≤10 ≤4 ≤4Pressure, bar 1.0 1.0 1.0 1.0Dimensions (wxdxh), mm 312x177x220 341x189x239 341x189x242 331x291x278.5Weight, kg 9.6 12.9 13.7 14.8

Cat. No. 521-090 521-092 521-094 521-095

Price POA POA POA POA

* Flow rate at atm. pressure

Diaphragm Vacuum and Pressure PumpsOil-free General purpose laboratory pumps for single or multi flask filtration, pressure filtration and vacuum ovenswith non-aggressive media and other general laboratory uses. Models N 022 AN.18 and N 035 AN.18 areoil-free vacuum pumps or compressors. Model N 035.3 AN.18 is an oil-free higher vacuum pump only. Allpumps are fitted with rubber feet, carrying handles, on-off switch and mains lead with moulded 13 amp plug.

SpecificationsModel N 022 AN.18 N 035 AN.18 N 035.3 AN.18Flow rate, m3/h (L/min) 0.9 (15) 1.8 (30) 1.8 (30)Vacuum, mBar 100 100 13Compression, bar 4 4 ————Dimensions (wxdxh), mm 203x103x194 265x143x254 294x250x222Weight, kg 4 8.2 11.3Electrical supply 240V/50Hz/60W 240V/50Hz/220W 240V/50Hz/300W

Cat. No. 521-021 521-022 521-024

Price POA POA POA

Accessories

Cat. No. Description For model Price Cat. No. Description For model Price

521-025 Spare kit N 022 AN.18 POA 521-028 Spare kit N 035.3 AN.18 POA

521-026 Spare kit N 035 AN.18 POA

■ Drying system operates independently ofpumping procedure

■ Fast, efficient evacuation of saturatedvapours

■ Drying operation can be adjusted to suit anindividual process

■ Excellent gas-tightness with PTFE-coateddiaphragm

■ High suction, small size■ Portable with retractable handle■ Maintenance-free and reliable operation■ Quiet and smooth running■ High vapour and condensate tolerance■ Contamination-free pumping of air, gases

and vapours

521-090521-094 521-092

521-022

521-024

521-021

Page 16: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukVacuubrand

Pumps

762 Take a look at our latest products on www.ecomcat.co.uk

Diaphragm PumpsVacuubrand diaphragm pumps are totally oil free, mechanical vacuum pumps. Two basic versions are available:

Standard versionThe materials of the wetted parts are made of aluminium, FPM (e.g. Viton®) and polyamide. This isadequate for less aggressive gases and vapours.

Chemistry versionAll wetted parts of the chemistry version are made of chemically resistant fluorinated plastic materials, e.g.PTFE-sandwich diaphragms or ECTFE (e.g., Halar®) clamping discs with stainless steel core. This makes theChemistry version ideal for rotary evaporation, distillation, vacuum concentration, gel drying etc.

Vacuubrand diaphragm pumps offer high flow rates at low vacuum, excellent reliability and vacuumstability. They are inexpensive and simple to service and maintain. All units are supplied with on/offswitch, mains cable with plug and instructions. The Chemistry versions are also supplied with gas ballast.

Specifications for Standard PumpsModel ME2 ME4 ME4R ME8Maximum flow rate, m3/h (L/min) 1.9 (31) 3.7 (61) 3.6 (56) 6.5 (108)Ultimate vacuum, mbar <80 <80 <100 <80Maximum pressure (bar abs) 2 4 4 2Dimensions (lxwxh), mm 275x173x175 266x235x175 226x235x175 315x235x200Weight, kg 6.3 10.1 11.0 15.5Electrical supply 230V, 50/60Hz 230V, 50/60Hz 230V, 50/60Hz 230V, 50/60Hz

Cat. No. 521-104 521-105 521-101 521-106

Price POA POA POA POA

Specifications for Chemistry Version PumpsModel ME2C MZ2C MD1C MD4CMaximum flow rate, m3/h (L/min) 1.7 (28) 1.7 (28) 1.0 (16) 3.0 (50)Ultimate vacuum, mbar 80 9 2 2Maximum pressure (bar abs) 2 2 1.1 1.1Dimensions (lxwxh), mm 258x173x178 266x241x170 303x165x215 315x241x176Weight, kg 6.6 10.5 6.5 16.2Electrical supply 230V, 50/60Hz 230V, 50/60Hz 230V, 50/60Hz 230V, 50/60Hz

Cat. No. 521-088 521-107 521-108 521-176

Price POA POA POA POA

For accessories see page 765.

Chemistry Diaphragm Pumping UnitsThe oil free chemistry diaphragm pumping units with condensate catchpots can be used in a wide rangeof applications for evaporation or pumping of corrosive gases. The special catchpot system improveslifetime and reliability and the exhaust waste vapour condenser (on +EK models only) offers highlyefficient solvent recovery.

All units are supplied with pump stand and inlet catchpot, on/off switch, mains cable with plug andinstructions. In addition, unit MZ2C+2AK is supplied with an exhaust catchpot, whereas unitsMZ2C+AK+EK, MD1C+AK+EK and MD4C+AK+EK are supplied with an exhaust condenser.

Specifications for Chemistry Version Pumping UnitsModel MZ2C+2AK MZ2C+AK+EK MD1C+AK+EK MD4C+AK+EKMaximum flow rate, m3/h (L/min) 1.7 (28) 1.7 (28) 1.0 (16) 3.0 (50)Ultimate vacuum, mbar 9 9 2 2Dimensions (lxwxh), mm 336x241x326 336x241x500 336x165x500 315x241x176Weight, kg 13.5 13.5 9.2 16.2Electrical supply 230V, 50/60Hz 230V, 50/60Hz 230V, 50/60Hz 230V, 50/60Hz

Cat. No. 521-109 521-110 521-111 521-112

Price POA POA POA POA

■ High performance■ Compact

■ Low noise■ Pollution free

■ Long lifetime

521-104

521-101

521-176

521-110

Page 17: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

PumpsVacuubrand

Take a look at our latest products on www.ecomcat.co.uk 763

Chemistry Pumping UnitsThe Vacuubrand laboratory pumping units generate totally oil free vacuum, maintain predeterminedvacuum, control exhaust vapour emissions and allow solvent recovery. The pumping unit components aremade of chemically resistant materials. Units PC510 and PC610 have one vacuum controller, units PC520and PC620 are supplied with two vacuum controllers.

All units are supplied with chemistry diaphragm pump on pump support, catchpot (inlet side) withisolation valve, vacuum controller, air admittance valve, exhaust waste vapour condenser and instructions.

Specifications for Chemistry Controlled Pumping UnitsModel PC510 PC520 PC610 PC620Maximum flow rate, m3/h (L/min) 1.7 (28) 1.7 (28) 3.0 (50) 6.5 (108)Ultimate vacuum, mbar 9 9 2 2Dimensions (lxwxh), mm 400x251x536 400x369x538 400x251x536 400x369x538Weight, kg 18.5 21 25.0 27.5Electrical supply 230V, 50/60Hz 230V, 50/60Hz 230V, 50/60Hz 230V, 50/60Hz

Cat. No. 521-113 521-114 521-115 521-116

Price POA POA POA POA

For accessories see page 765.

Chemistry Vario Pumping UnitsVario pumping units can precisely maintain a predetermined vacuum level or automatically find theoptimum vacuum/distillation level. They are ideal for rotary evaporators, with virtually 100% solventrecovery, enhanced lifetime and RS232 interface.

All units are supplied with chemistry diaphragm pump mounted on pump support, vacuum controllerCVC2000, catchpot inlet side, exhaust waste vapour condenser and instructions.

Specifications for Chemistry Vario Pumping UnitsModel PC2001 PC2003 PC2004 PC2010Maximum flow rate, m3/h (L/min) 1.5 (25) 1.9 (31) 3.8 (63) 8.2 (136)Ultimate vacuum, mbar 2 0.6 2 0.6Dimensions (lxwxh), mm 310x280x470 400x251x536 400x251x536 650x370x610Weight, kg 9.2 25.0 25.0 37.0Electrical supply 230V, 50/60Hz 230V, 50/60Hz 230V, 50/60Hz 230V, 50/60Hz

Cat. No. 521-117 521-118 521-119 521-120

Price POA POA POA POA

For accessories see page 765.

Chemistry Hybrid PumpChemistry Hybrid Pumps are ideal for fine vacuum chemistry applications such as freeze drying andmolecular distillations.

The oil sealed stages of the pump are constantly evacuated by a chemically resistant two stagediaphragm pump, thus avoiding harmful condensation within this sensitive part of the pump, whilstreducing the partial pressure of the gases and permanently distilling the oil.

All units are supplied with on/off switch, mains cable with plug and instructions.

Specifications for Chemistry Hybrid PumpModel RC5Maximum flow rate, m3/h (L/min) 5.6 (93)Vacuum (partial), mbar 4x10-4

Maximum pressure (total) mbar 2x10-3

Dimensions (lxwxh), mm 505x300x210Weight, kg 25.5Electrical supply 230V, 50/60Hz

Cat. No. Description Price

521-121 RC5 Chemistry Hybrid pump POA

For accessories see page 765.

521-113

521-117

521-121

Page 18: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukVacuubrand

Pumps

764 Take a look at our latest products on www.ecomcat.co.uk

Rotary Vane PumpsRotary vane pumps are designed for an ultimate vacuum in the range of 1 mbar to 10-1 (single-stage) or10-3 mbar (two-stage). The rotary vane pump series with integrated oil pump and highly effective gasballast system for improved water vapour tolerance, achieves a powerful combination of performanceand cost effectiveness. These compact and high performance pumps together with their modularaccessories can be used for a wide range of laboratory and process applications.

■ High conductance inlet - high pumping speed even at low vacuum ■ High vapour tolerance - for water and solvents with gas ballast of about 10% ■ Anti-corrosion design - plasma treated internal surfaces and oil shut-off device to prevent back

flow of gases ■ Quieter operation with longer service intervals - improved lubrication circuit and larger oil reservoir ■ Compact design - smaller dimensions and low weight ■ Reduced power consumption - improved motor design with immediate re-start after shutdown

SpecificationsModel RE2.5 RZ2.5 RE6 RZ6Maximum flow rate, m3/hr (L/min) 2.3/2.8 (47) 2.3/2.8 (47) 5.7/6.8 (113) 5.6 (113)Ultimate vacuum without gas ballast, mbar 3x10-1 2x10-3 1x10-1 2x10-3

Ultimate vacuum with gas ballast, mbar 8x10-1 1x10-2 6x10-1 1x10-2

Water vapour tolerance, mbar 40 40 40 40Water vapour capacity, gh-1 65 65 159 159Dimensions (lxwxh), mm 308x125x190 308x125x190 370x142x207 370x142x207Weight, kg 10.2 11.4 15.3 16.4Electrical supply 230V, 50/60Hz (all models)

Cat. No. 521-122 521-126 521-123 521-127

Price POA POA POA POA

SpecificationsModel RE9 RZ9 RE16 RZ16Maximum flow rate, m3/hr (L/min) 8.6/9.9 (165) 8.6 (165) 16.6/19.1 16.6/19.1

(318) (318)Ultimate vacuum without gas ballast, mbar 1x10-1 2x10-3 1x10-1 2x10-3

Ultimate vacuum with gas ballast, mbar 6x10-1 1x10-2 6x10-1 1x10-2

Water vapour tolerance, mbar 40 40 40 40Water vapour capacity, gh-1 246 246 474 474Dimensions (lxwxh), mm 460x152x232 460x152x232 505x152x232 545x152x232Weight, kg 22.1 24.6 25.2 29Electrical supply 230V, 50/60Hz (all models)

Cat. No. 521-124 521-128 521-125 521-129

Price POA POA POA POA

For accessories see page 765.

521-126New

521-127New

521-128New

Page 19: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

PumpsVacuubrand

Take a look at our latest products on www.ecomcat.co.uk 765

Pump AccessoriesInlet Separators and Oil Mist Filters

Inlet separator - to protect pump from particulate matter both in liquid and solid form.

Oil mist filter - prevents loss of oil to atmosphere and reduces condensate build up in pumps.

Cat. No. Description For Model Price

521-130 Inlet separator RE2.5/RZ2.5 POA

521-131 Inlet separator RE6/RZ6 POA

521-132 Inlet separator RE9/RZ9, RE16/RZ16 POA

521-177 Oil mist filter RE2.5/RZ2.5, RE6/RZ6 POA

521-178 Oil mist filter RE9/RZ9 RE16/RZ16 POA

Cold Traps GKF 1000i - glass cold trap with mirror insulated jacket, PTFE stopcock, sight strip and implosion protection.

SKF H - stainless steel cold trap offers excellent cooling properties, is easy to drain, disassemble and clean.

Cat. No. Description Connections For Model Price

521-133 GKF 1000i, glass Pump side – 22mm o.d. RE2.5/RZ2.5 POAPlant side – NS29/32 glass joint

521-134 SKF H 25, stainless steel NW25 RE6/RZ6 POA

521-135 SKF H 40, stainless steel NW40 RE9/RZ9, RE16/RZ16 POA

Chemically resistant gauges and controllers

Specifications for Gauges and ControllersModel DVR2 DVR5 VAP5 CVC211*Type Rough vacuum Rough vacuum Fine vacuum Rough vacuum

gauge gauge gauge controllerMeasuring range, mbar 1080 to 1 1100 to 0.1 1000 to 10-3 1300 to 1Uncertainty of measurement, mbar <±1 ±1 ±10% of <0.5% of range

indicated valueMeasuring principle Capacitive, Capacitive, Pirani Piezoresistive

independent independent (thermalof gas type of gas type conductivity)

Cat. No. 521-136 521-137 521-138 521-139

Price POA POA POA POA

* Operates in conjunction with Vacuubrand 24v magnetic solenoid valves, see cat item 521-175.

Service Kits

Cat. No. Description For Model Price

521-140 Service kit ME2 POA

521-141 Service kit ME4, ME4R POA

521-142 Service kit ME8 POA

521-143 Service kit ME2C POA

521-144 Service kit MZ2C POA

521-145 Service kit MD1C POA

521-146 Service kit RE2.5/RZ2.5, RE6/RZ6 POA

521-147 Service kit RE9/RZ9, RE16/RZ16 POA

521-148 Service kit RC5 POA

521-149 Service kit MD4C POA

521-132

521-177

521-133

521-178

521-137

Page 20: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukIlmvac

Pumps

766 Take a look at our latest products on www.ecomcat.co.uk

521-150 PK Series Rotary Vane Vacuum PumpsExtremely compact and quiet rotary vane type vacuum pumps. With high vapour tolerance and a rangeof solvent and acid handling accessories these pumps are ideal for freeze drying and general laboratoryapplications.

■ Compact design■ High tolerance to chemical processes■ Very quiet operation

Supplied with oil, mains lead and plug and gas ballast valve. Other models with various flow rates andultimate vacuums available.

Specifications Model PK2DC PK4Dp PK6Dp PK8DpFlow rate, m3/hr (L/min) 1.8 (30) 4.6 (76) 6.4 (106) 8.3 (138)Ultimate vacuum, mbar <1x10-3 <2x10-4 <2x10-4 <2x10-4

Water vapour tolerance, mbar 33 40 40 40Dimensions (wxdxh), mm 300x120x150 405x150x200 405x150x200 430x150x200Weight, kg 8 19 19 21.5Oil capacity, ml 250 500 500 650Electrical supply 230V, 50/60Hz (all models)

Cat. No. 521-150 521-152 521-300 521-154

Price POA POA POA POA

Accessories

Cat. No. Description Price

Oil mist removal filters

521-155 Oil mist filter for model PK2DC POA

521-301 Oil mist filter for models PK4/6/8Dp POA

521-302 Spare cartridge for oil mist filter 521-155 and 521-301 POA

Inlet filters

521-303 Inlet catch-pot for models PK4/6/8Dp. Collects liquids before the pump POA

521-304 Adsorption trap to prevent streaming in high vacuum applications. (All models) POA

521-305 Spare cartridge for trap 521-304 POA

External oil filters

521-306 Filter for physical applications, to filter particles of solid content POA

521-307 Spare cartridge for filter 521-306 POA

521-308 Filter for chemical applications to neutralise acids in the oil POA

521-309 Spare cartridge for filter 521-308 POA

Other models with various flow rates and ultimate vacuums are available. Please contact our Technical Office on01342 826836 for details.

DryRun10 Scroll Vacuum PumpFully chemically resistant scroll vacuum pump with high vapour tolerance for laboratory applicationsrequiring fine vacuum. Uniquely, only the scroll is under vacuum. PTFE surfaces and seals achieve classleading resistance to chemical processes. The vertical shaft design places the exhaust port at the lowestpoint in the pump allowing condensed solvents to run out of the pump.

■ PTFE wetted surfaces■ PTFE seals■ Vertical shaft design

Specification Flow rate, m3/hr (L/min) 10 (67)Ultimate vacuum, mbar 7x10-2

Water vapour tolerance, mbar 50Motor power, kW 0.55Dimensions (lxwxh), mm 470x320x440Connection DN25KFWeight, kg 30Electrical supply 230V, 50/60Hz

Cat. No. Description Price

521-310 DryRun 10 Scroll vacuum pump POA

New

521-152New

521-310New

Page 21: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

PumpsIlmvac

Take a look at our latest products on www.ecomcat.co.uk 767

512-312PK4DpX Rotary Vane Vacuum PumpGeneral purpose laboratory vacuum pump designed for high vapour tolerance and incorporating intakeseparator and exhaust side oil mist eliminator. The pump is pre-filled with oil (oil capacity: 500ml) andhosetail connections are also included to enable the pump to be used straight out of the box.

■ Compact design■ High tolerance to chemical processes■ Very quiet operation

Supplied with oil, mains lead and plug, inlet and outlet 12mm nozzles, exhaust mist filters and inletcatch-pot.

Specification Flow rate, m3/hr (L/min) 4.6 (76)Ultimate vacuum, mbar 2x10-4

Water vapour tolerance, mbar 40Motor power, kW 0.37Separator on intake side Glass catch-pot, nickelised aluminium connection, mounted to side of

pump bodyOil mist eliminator, exhaust side Glass catch-pot with coalescing filter media and over-pressure protec-

tion, nickelised aluminium connection, mounted to side of pump bodyConnections intake and outlet DN16KF flange supplied with 12mm hose nozzle, clamp and sealDimensions (wxdxh), mm 405x150x200Weight, kg 19Electrical supply 230V, 50/60Hz

Cat. No. Description Price

521-312 PK4DpK Two stage rotary vane pump POA

Accessories

Cat. No. Description Price

521-308 OPF40C Acid neutralising external oil filter POA

HBP100 Hold-Back-Pump for Vacuum DistillationThe HBP100 is a new and unique solution for solvent evaporation and condensation. It provides acomplete, automatically controlled vacuum pump and condenser unit at considerable capital cost savingsover conventional solutions.

Specification Pumping speed, L/min (m3/hr) 2.3 (40)Ultimate vacuum, mbar 10, self-regulatingVacuum connection hose nozzle DN10 for 10mm ID tubingExhaust connection clamping union for 6mm ID tubingWater connections clamping union for 6mm ID tubingSolvent collection vessel round flask 1000ml with S35 joint and clampNoise level <45 db(A)Electrical supply 230V/50HzProtection IP42Dimensions (wxdxh), mm 375x460x395Weight, kg 8.9

Cat. No. Description Price

521-166 HBP100 Hold Back Pump POA

Self-regulation Vacuum Level■ No vacuum or process controller required■ No process set-up required■ No solvent bumping■ No process or solvent knowledge required

Near 100% Solvent Containment■ Environmentally sound■ Safe for bench-top operation■ Separate and re-use solvents

Simple and Flexible Set-up■ Fewer system components■ Provides a single box solution for many

applications■ Integrates with and enhances existing

equipment for a wider range of applications

Small Footprint■ Save valuable bench or fume-cupboard space■ Site in back of fume cupboard and operate

via the remote control provided

521-166 New

Page 22: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukIlmvac

Pumps

768 Take a look at our latest products on www.ecomcat.co.uk

MPC-Series, Full PTFE Construction Diaphragm PumpsA highly cost efficient range of PTFE diaphragm pumps. The diaphragm and all parts coming into contactwith the vapours are PTFE or PTFE-compounds. Supplied ready for use with a 2 year warranty.

■ All wetted parts made from PTFE materials ■ Suitable for pumping solvent and acid vapours ■ Optimised for high flow rate and stable final vacuum ■ Long lasting, self cleaning valves made of PEEK ■ Low noise and vibration ■ Drive and bearing isolated from air cooling stream ■ 8mm hose tails (options on request) ■ 10,000 hour service interval and 2 year warranty ■ Low cost spares and easy servicing ■ Applications include: distillation, non-aqueous filtration, gel drying, rotary evaporators,

centrifugal evaporations

Supplied with carry handle, mains lead and plug, gas ballast valve, exhaust silencer and 8mm inlet andoutlet nozzles.

Specifications Model MPC102E MPC201E MPC601E MPC1201E MPC2401EFlow rate, m3/hr (L/min ) 0.8 (13) 1.8 (30) 3.8 (63) 8.3 (138) 15.5 (258)Ultimate vacuum, mbar <75 <75 <75 <75 <75Dimensions (wxdxh), mm 124x210x223 195x235x145 230x265x169 230x265x169 540x300x240Weight, kg 5.7 6.5 7.8 12.5 24.0Electrical supply 230V, 50/60Hz (all models)

Cat. No. 521-157 521-526 521-527 521-528 521-529

Price POA POA POA POA POA

Specifications Model MPC052Z MPC101Z MPC301Z MPC901Z MPC1801ZFlow rate, m3/hr (L/min ) 0.5 (8) 1.0 (17) 2.3 (38) 6.8 (113) 12.0 (200)Ultimate vacuum, mbar <8 <8 <8 <8 <8Dimensions (wxdxh), mm 124x210x223 195x235x145 230x265x169 230x265x169 540x300x240Weight, kg 5.7 6.5 7.8 12.5 24.0Electrical supply 230V, 50/60Hz (all models)

Cat. No. 521-158 521-159 521-160 521-530 521-531

Price POA POA POA POA POA

Specifications Model MPC201T MPC601T MPC1201T MPC301VFlow rate, m3/hr (L/min ) 2.0 (33) 4.5 (75) 8.3 (138) 2.3 (38)Ultimate vacuum, mbar <2 <2 <2 <1Dimensions (wxdxh), mm 200x260x150 230x380x169 540x300x240 230x380x169Weight, kg 10.3 12.5 24 12.5Electrical supply 230V, 50/60Hz (all models)

Cat. No. 521-161 521-532 521-533 521-534

Price POA POA POA POA

Service kits are available. Please contact our Technical Office on 01342 826836 for details.

Other models with various flow rates and ultimate vacuums available. Please contact our Technical Office on 01342826836 for details.

521-157

521-533

521-159

521-530

New

New

Page 23: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

PumpsIlmvac

Take a look at our latest products on www.ecomcat.co.uk 769

521-511MP Series, Diaphragm PumpsA low cost range of diaphragm pumps for general applications not requiring chemical resistance.Supplied ready for use with a 2 year warranty.

■ Aluminium construction■ Low noise and vibration■ Optimised for high flow rate and stable final vacuum■ 8mm hose tails (options on request)■ 10,000 hour service intervals and 2 year warranty■ Low cost spares and easy servicing■ Applications include: Aqueous filtration, vacuum tweezers, vacuum ovens, general applications

to 1 mbar

Pumps are supplied ready to use with carrying handle, mains lead and plug, 8mm inlet connection andexhaust silencer.

Specifications Model MP102E MP201E MP601E MP1201E MP2401EFlow rate, m3/hr (L/min ) 0.8 (13) 1.8 (30) 3.8 (63) 8.3 (138) 15.53 (258)Ultimate vacuum, mbar <75 <75 <75 <75 <75Dimensions (wxdxh), mm 124x210x223 195x235x145 230x265x169 230x265x169 540x300x240Weight, kg 5.7 6.5 7.8 12.5 24.0Electrical supply 230V, 50/60Hz (all models)

Cat. No. 521-510 521-511 521-512 521-513 521-514

Price POA POA POA POA POA

Specifications Model MP052Z MP101Z MP301Z MP901Z MP1801ZFlow rate, m3/hr (L/min ) 0.5 (8) 1.0 (17) 2.3 (38) 6.8 (113) 12.0 (200)Ultimate vacuum, mbar <8 <8 <8 <8 <8Dimensions (wxdxh), mm 124x210x223 195x235x145 230x265x169 230x265x169 540x300x240Weight, kg 5.7 6.5 7.8 12.5 24.0Electrical supply 230V, 50/60Hz (all models)

Cat. No. 521-515 521-516 521-517 521-518 521-519

Price POA POA POA POA POA

Specifications Model MP201T MP601T MP1201T MP101V MP301VFlow rate, m3/hr (L/min ) 2.0 (33) 4.5 (75) 8.3 (138) 1.0 (17) 2.3 (38)Ultimate vacuum, mbar <2 <2 <2 <1 <1Dimensions (wxdxh), mm 200x260x150 230x380x169 540x300x240 200x260x150 230x380x169Weight, kg 10.3 12.5 24 10.3 12.5Electrical supply 230V, 50/60Hz (all models)

Cat. No. 521-520 521-521 521-522 521-523 521-524

Price POA POA POA POA POA

SpecificationModel MP030ZFlow rate, m3/hr (L/min ) 0.4 (5)Ultimate vacuum, mbar <5Dimensions (wxdxh), mm 102x116x45Weight, kg 0.8Electrical supply 230V, 50/60Hz

Cat. No. 521-525

Price POA

For details on accessories, including service kits please contact our Technical Office on 01342 826836.

New

521-519 New

521-520 New

521-515 New

Page 24: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukIlmvac

Pumps

770 Take a look at our latest products on www.ecomcat.co.uk

521-563New

521-564New

521-567New

521-573New VCB324 Vacuum ControllerA complete vacuum control solution for any vacuum source. All the components are contained in asingle compact unit ready for use. Simply connect via tubing to a vacuum pump or bench outlet, couplevia tubing to your process and you have a fully featured controlled vacuum source.

■ No trailing wires or clamp stands ■ Manual and automatic boiling point determination ■ Easy, on-the-fly adjustments ■ Static memory for reproducible results ■ RS232 remote control and data-logging ■ Easy cleaning, virtually maintenance free ■ 2 year warranty

This unique product is supplied fully configured and ready to use. Tubing connection for vacuum andprocess are 8mm hose barbs.

SpecificationMeasuring range, mbar 1100 to 1Accuracy, mbar ±2Display LED in mbars and torsDimensions (wxdxh), mm 200x170x165Thresholds/output at front panel 24V DC 10W per channel, 30W totalVacuum connection at sensor female thread 1/4 inch, DN 16 KFWeight, kg 1.5Electrical supply 90-240V, 50-60Hz, 40W

Cat. No. Description Price

521-573 VCB324 Vacuum controller POA

Chemvac Series, High Vacuum Pumps for Chemical ApplicationsA unique range of high vacuum pumps designed to prevent solvent condensation in the pump oil. Thecombined oil and diaphragm stages give the benefits of rotary vane pump vacuum levels with PTFEdiaphragm pump chemical resistance.

■ High resistance to solvent and acid vapours ■ Extremely long oil change and service intervals ■ External oil filtering available for acid neutralization ■ Inter-stage catch-pots retain solvents ■ Applications include: Freeze drying of non-aqueous samples, centrifugal concentrators, drying

ovens, high vacuum distillations ■ 2 year warranty

Pumps are supplied ready to use, charged with oil, with mains lead and plug, inter-stage catch-pots andKF16 or KF25 connections.

Specifications for pumps with one rotary vane stage and two PTFE diaphragm stagesModel 4S-101 8S-101 12S-101 17S-101 23S-101Flow rate, m3/hr (L/min) 3.7 (62) 7.3 (120) 11.0 (183) 16.0 (266) 21.0 (350)Ultimate vacuum, mbar <3x10-2 <3x10-2 <3x10-2 <3x10-2 <3x10-2

Dimensions (wxdxh), mm 470x230x320 470x230x320 480x230x380 570x230x380 570x230x380Weight, kg 18.2 19.0 25.0 30.0 35.0Electrical supply 230V, 50/60Hz (all models)

Cat. No. 521-563 521-564 521-565 521-566 521-567

Price POA POA POA POA POA

Specifications for pumps with two rotary vane stages and two PTFE diaphragm stagesModel 4D-101 8D-101 12D-101 17D-101 23D-101Flow rate, m3/hr (L/min) 3.7 (62) 7.3 (120) 11.0 (183) 16.0 (266) 21.0 (350)Ultimate vacuum, mbar <3x10-3 <3x10-3 <3x10-3 <3x10-3 <3x10-3

Dimensions (wxdxh), mm 470x230x320 470x230x320 480x230x380 570x230x380 570x230x380Weight, kg 19.0 21.3 26.0 31.0 36.0Electrical supply 230V, 50/60Hz (all models)

Cat. No. 521-568 521-569 521-570 521-571 521-572

Price POA POA POA POA POA

For details on accessories, including service kits please contact our Technical Office on 01342 826836.

Page 25: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

PumpsIlmvac

Take a look at our latest products on www.ecomcat.co.uk 771

LVS Series, Laboratory Vacuum SystemsThe latest solutions for solvent handling in the laboratory, LVS units are based on the MPC range ofchemically resistant diaphragm pumps with solvent containment condensers. They are available with orwithout control. There are four control options available:

None: The vacuum level is not controlled.

Standard Valve: The vacuum pump operates continuously and the process vacuum level is controlledby a chemically resistant solenoid valve. Set points can be preset, altered during the process, ordetermined automatically using the boiling point finding facility.

Management: The pump starts and stops automatically to maintain vacuum within your set range.Ideal for operating vacuum lines and networks where service intervals are greatly extended.

Ecoflex: The pump’s flow rate is automatically varied to maintain the set point by matching the vapourload. Set points can be preset, altered during the process, or determined automatically using the boilingpoint finding facility. Ideal for rotary evaporators, where process times can be reduced by up to 30%.Service intervals are greatly extended. VCZ324 controller included.

■ Only PTFE compounds and glass in contact with the vapour stream ■ Solvent containment to approximately 98% ■ Small footprint ■ Interchangeable vacuum pumps for future flexibility ■ 10,000 hour service intervals and 2 year warranty ■ RS232 facility and data-logging control software available

Systems are supplied ready to use with pump, inlet catch-pot, water cooled emission condenser, mainslead and plug. Optional control modes fully installed where selected.

521-538 New

Specifications - Two stage vacuum systems with no control or standard valve controlModels LVS 0501 LVS 101 LVS 300 LVS 310

LVS 0501RM LVS 101RM LVS 301 LVS 311LVS 0510 LVS 110 LVS 302 LVS 320

Flow rate, m3/hr (L/min ) 0.4 (8) 1.0 (17) 2.3 (38) 2.3 (38)Ultimate vacuum, mbar <8 <8 <8 <8Dimensions (wxdxh), mm 310x270x520 310x270x520 310x270x520 310x270x520Weight, kg 9.1/9.2/9.6 10.5/11.0/13.2 17.5/18.5/17.5 19.2/19.5/19.8Electrical supply 230V, 50/60Hz 230V, 50/60Hz 230V, 50/60Hz 230V, 50/60Hz

Specifications - Three stage vacuum systems with no control or standard valve controlModels LVS 201T LVS 601T LVS 610T LVS1201T

LVS 210T LVS 602T LVS 611T ———————— ———— LVS 620T ————

Flow rate, m3/hr (L/min ) 1.8 (33) 4.5 (75) 4.5 (75) 8.3 (138)Ultimate vacuum, mbar <2 <2 <2 <2Dimensions (wxdxh), mm 310x270x520 310x270x520 310x270x520 540x310x520Weight, kg 14.0/15.0 25.0/22.5 26.5/27.0/27.5 30.0Electrical supply 230V, 50/60Hz 230V, 50/60Hz 230V, 50/60Hz 230V, 50/60Hz

Specifications - Two stage vacuum systems with Management or Ecoflex systemModels LVS 110 M LVS 310 M

———— LVS 310 EFlow rate, m3/hr (L/min ) 1.0 (17) 2.3 (38)Ultimate vacuum, mbar <8 <8Dimensions (wxdxh), mm 310x270x520 310x270x520Weight, kg 19.2 20.5/14.7Electrical supply 230V, 50/60Hz 230V, 50/60Hz

Specifications - Three stage vacuum systems with Management or Ecoflex systemModel LVS 210T E LVS 610 TM LVS 1210 TM

———— LVS 610 TE LVS 1210 TEFlow rate, m3/hr (L/min ) 1.8 (33) 4.5 (75) 8.3 (138)Ultimate vacuum, mbar <2 <2 <2Dimensions (wxdxh), mm 310x270x520 310x270x520 540x310x520Weight, kg 20.7 27.5/28.5 30.5/32.0Electrical supply 230V, 50/60Hz 230V, 50/60Hz 230V, 50/60Hz

Laboratory vacuum systems are supplied ready to use with pump, inlet catch-pot, water cooled emission condenser,mains lead and plug.

521-553 New

521-562 New

521-556 New

Page 26: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukIlmvac

Pumps

772 Take a look at our latest products on www.ecomcat.co.uk

LVS Series, Laboratory Vacuum Systems, continued…Two-stage Laboratory Vacuum Systems with no control or standard valve control

Cat. No. Description Price

521-535 LVS 0501 Laboratory vacuum system with MPC 052Z pump, one uncontrolled connection POA

521-536 LVS 0501 RM Laboratory vacuum system with MPC 052Z pump, manometer, one uncontrolled connection POA

521-537 LVS 0510 Laboratory vacuum system with MPC 052Z pump, controller – POAcomplete module with external sensor, airing valve, one controlled connection

521-538 LVS 101 Laboratory vacuum system with MPC 101Z pump, one uncontrolled connection POA

521-539 LVS 101 RM Laboratory vacuum system with MPC 101Z pump, manometer, one uncontrolled connection POA

521-540 LVS 110 Laboratory vacuum system with MPC 101Z pump, controller – POAcomplete module with external sensor, airing valve, one controlled connection

521-541 LVS 300 Laboratory vacuum system with MPC 301Z pump POA

521-542 LVS 301 Laboratory vacuum system with MPC 301Z pump, one uncontrolled connection POA

521-543 LVS 302 Laboratory vacuum system with MPC 301Z pump, two uncontrolled connections POA

521-544 LVS 310 Laboratory vacuum system with MPC 301Z pump, controller – POAcomplete module with external sensor, airing valve, one controlled connection

521-545 LVS 311 Laboratory vacuum system with MPC 301Z pump, controller – POAcomplete module with external sensor, airing valve, one controlled and one uncontrolled connection

521-546 LVS 320 Laboratory vacuum system with MPC 301Z pump, controller – POAcomplete module with external sensor, airing valve, two controlled connections

Three-stage Laboratory Vacuum Systems with no control or standard valve control

Cat. No. Description Price

521-547 LVS 201T Laboratory vacuum system with MPC 201T pump, one uncontrolled connection POA

521-548 LVS 210T Laboratory vacuum system with MPC 201T pump, controller – POAcomplete module with external sensor, airing valve, one controlled connection

521-549 LVS 601T Laboratory vacuum system with MPC 601T pump, one uncontrolled connection POA

521-550 LVS 602T Laboratory vacuum system with MPC 602T pump, two uncontrolled connections POA

521-551 LVS 610T Laboratory vacuum system with MPC 601T pump, controller – POAcomplete module with external sensor, airing valve, one controlled connection

521-552 LVS 611T Laboratory vacuum system with MPC 601T pump, controller – POAcomplete module with external sensor, airing valve, one controlled and one uncontrolled connection

521-553 LVS 620T Laboratory vacuum system with MPC 601T pump, controller – POAcomplete module with external sensor, airing valve, two controlled connections

521-554 LVS 1201T Laboratory vacuum system with MPC 1201T pump, controller – POAcomplete module with external sensor, airing valve, one controlled connection

Two-stage Laboratory Vacuum Systems with Management or Ecoflex System

Cat. No. Description Price

521-555 LVS 110M Laboratory vacuum system with MPC 101Z pump and management system POA

521-556 LVS 310M Laboratory vacuum system with MPC 301Z pump and management system POA

521-559 LVS 310E Ecoflex laboratory vacuum system with MPC 301Z pump and VCZ324 controller POA

Three-stage Laboratory Vacuum Systems with Management or Ecoflex System

Cat. No. Description Price

521-560 LVS 210TE Ecoflex laboratory vacuum system with MPC 201T pump and VCZ324 controller POA

521-557 LVS 610TM Laboratory vacuum system with MPC 601T pump and management system POA

521-561 LVS 610TE Ecoflex laboratory vacuum system with MPC 601T pump and VCZ324 controller POA

521-558 LVS 1210TM Laboratory vacuum system with MPC 1201T pump and management system POA

521-562 LVS 1210TE Ecoflex laboratory vacuum system with MPC 1201T pump and VCZ324 controller POA

For details on accessories, including service kits please contact our Technical Office on 01342 826836.

Page 27: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

Pumps

Take a look at our latest products on www.ecomcat.co.uk 773

451-150

Ilmvac, PLS301Z Diaphragm Pump SystemOil-free, mechanical vacuum pump, mounted on pump holder, with intake-side separator, delivery-sideemission condenser cooled by dry ice slurry.

Suitable for all applications between atmosphere and 8 mbar absolute including rotary and centrifugalevaporation, gel drying, filtration, drying ovens, desiccators and more.

Specification Flow rate, m3/hr (L/min) at 1000 mbar/20 mbar 2.3 (40)/1.4 (23)

Ultimate pressure, mbarWithout gas ballast 8

Construction Pump: carbon-fibre reinforced PTFE pump head, electrically conductive Sandwich diaphragm, fabric reinforced with a PTFE layer Materials coming into contact with the media are resistant to chemicals (PVDF, PEEK) Built-in gas ballast valve Special feet for isolating the pump vibrations

Separator, on intake side Round-bottomed glass flask, 500ml (coated)Emission condenser, on Glass demountable CO2 trap with removable well and lid delivery side 100% restricted guidance of the pumped medium

without by-pass beneath the cooling surface Collection flask 500 ml

Connections Intake: DN10 clamping ring screw fittings Outlet: DN10 clamping ring screw fittings Cooling water: 2x DN8 ports

Dimensions (wxdxh), mm 310x270x500Weight, kg 18.5Electrical supply 230V, 50HzCE conformity M-RL, NS-RL, EMC

Cat. No. Description Price

521-313 PLS301Z Diaphragm pump system POA

Pfeiffer, Rotary Vane PumpsThese innovative double stage rotary vane pumps are suitable for all applications in the rough andmedium vacuum range, featuring pumping speeds of 80 to 160L/min. The drive concept – ‘integratedmagnetic coupling’ – ensures that the pumps are hermetically sealed. Separating the rotor and motorshafts solves the problem connected with rotary shaft seals. The wear-free drive prevents leaks, keepsmaintenance to a minimum and considerably lengthens the pump’s working life.

Pfeiffer rotary vane pumps also offer more process safety, with the high speed high vacuum safety valveintegrated as standard. This fast, hydraulically-controlled valve stops the pump immediately in the eventof faults such as power failure, undervoltage or process safety cutoff. Supplied with operating lubricant.

SpecificationsModel DUO 005M DUO 010MNominal pumping speeds, m3/h (L/min) 4.8 (80) 9.7 (160)Ultimate vacuum, mbarwithout gas ballast/with gas ballast <5x10–3/<2x10–2 <5x10–3/<1x10–2

Exhaust pressure maximum, mbar 1500 1500 Lubricant amount, L 0.75 1.0 Weight (approximate), kg 22 28Dimensions (wxdxh), mm 176x435x217 178x517x216

Cat. No. 451-149 451-150

Price POA POA

Accessories

Cat. No. Description Price

451-151 Clay filter POA

451-152 Zeolite trap POA

Cat. No. Description Price

451-153 Oil mist filter POA

451-154 Dust separator POA

■ High pumping speeds from a small pump■ Environmentally friendly, due to no oil leaks■ Easy to service, low maintenance costs■ Reliable start-up, down to 12°C

■ Ultra quiet, noise level <53 dB(A)■ Pump free of non-ferrous heavy metals■ Pressurised oil lubricated bearing, for

high reliability"vacuum"

"vacuum"

rotor shaft motor shaft

sleeve

radial shaft seal

coupling

Previous drive type

"vacuum"

New, wear-free drive with magnetic coupling

"vacuum"

rotor shaft motor shaft

O-ring Inner magnet

Outer magnet

"environment"

"environment"

521-313 New

Page 28: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukHeidolph

Pumps

774 Take a look at our latest products on www.ecomcat.co.uk

Peristaltic Pump Drives and HeadsThe Heidolph range includes 6 drives, 4 peristaltic pump heads and 3 multi-channel pump heads.Peristaltic pump drives are available with and without serial and analogue interfaces. They are ideal foraggressive, abrasive or corrosive solvents and sterilised media. Flow rates from 0.3ml up to 3,644ml perminute are available (H20), as are double pump head systems.

■ No contamination as fluid is in contact with the tubing only ■ Superior for transport of high viscous media up to 10,000cP■ Self-priming and come without valves and seals ■ Easily function under pressure and vacuum ■ Various chemically resistant and sterilisable tubes available for individual applications■ Interval dosing available (models PD 5201 and PD 5206 only) ■ 3 year warranty

PD 5001 and PD 5006 Pump Drives These peristaltic pump drives are suitable for standard applications; they have electronic speed control(accuracy ±2%), large dials for speed setting, protection to IP30 and can be stacked (up to 3 pumpdrives). Flow can be clockwise or counter clockwise.

The PD 5001 provides flow rates from 0.7 to 729ml per minute with a speed range of 10 to 120rpm. Itcan also be equipped with two pumps heads (SP quick and SP quick d) or with a multi-channel pumphead (C4, C8 or C12 - an adaptor is required but not supplied). Multi-channel flow rates are from 0.01to 336ml/min.

Model PD 5006 provides flow rates from 3.3 to 3,644ml per minute with a speed range of 50 to 600rpm.It is suitable for any of the single pumps heads, however it is not suitable for the use of multi-channelpump heads.

PD 5101 and PD 5106 Pump Drives These models are designed for more demanding applications. Both pump drives have an analogueinterface for speed range setting, direction of rotation and start/stop function. They have electronicspeed control (accuracy ±0.5%), large dials for speed setting, protection to IP55 and can be stacked (upto 3 pump drives). Flow can be clockwise or counter clockwise and the filling and emptying of tubing canbe accelerated by a push-button.

The PD 5101 provides flow rates from 0.3 to 729ml per minute with a speed range of 5 to 120rpm. It canalso be equipped with two pumps heads (SP quick and SP quick d) or with a multi-channel pump head(C4, C8 or C12 - an adaptor is required but not supplied). Multi-channel flow rates are from 0.005 to336ml/min.

Model PD 5106 provides flow rates from 1.6 to 3,644ml per minute with a speed range of 24 to 600rpm.It is suitable for any of the single pumps heads, however it is not suitable for the use of multi-channelpump heads.

PD 5201 and PD 5206 Pump Drives Both the PD 5201 and PD 5206 pump drives have an analogue and digital RS232 interface for speedrange setting, direction of rotation and start/stop function. They feature a four-digit display for electronicspeed setting, electronic speed control (accuracy ±0.5%), protection to IP 55 and they can be stacked (upto 3 pump drives). The four-digit display is also used for flow rate setting, interval dosing and pausesetting. Flow can be clockwise or counter clockwise and the filling and emptying of tubing can beaccelerated by a push-button. Other features include:

■ Calibration of flow rate and flow volume ■ Microprocessor controlled drive ■ Flow rates of the pump heads in combination with the various tubing are saved in the program

to enable direct digital readout of flow rate ■ In addition to the flow rate readout, it is possible to pre-select a dosing volume ■ Interval dosing is possible by entering a time interval

Pump drive PD 5201 provides flow rates from 0.3 to 729ml per minute with a speed range of 5 to120rpm. It can also be equipped with two pumps heads (SP quick and SP quick d) or with a multi-channelpump head (C4, C8 or C12 - an adaptor is required but not supplied). Multi-channel flow rates are from0.005 to 336ml/min.

Model PD 5106 provides flow rates from 1.6 to 3644ml per minute with a speed range of 24 to 600rpm.It is suitable for any of the single pumps heads, however it is not suitable for use with multi-channelpump heads.

521-600 shown with 521-631New

521-601 shown with 521-634New

521-602 shown with 521-631New

521-603 shown with 521-634New

Page 29: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

PumpsHeidolph

Take a look at our latest products on www.ecomcat.co.uk 775

Peristaltic Pump Drives and Heads, continued…SpecificationsModel PD 5001 PD 5006 PD 5101 PD 5106 PD 5201 PD 5206Flow rate ranges, ml/min 0.7–729 3.3–3644 0.3–729 1.6–3644 0.3–729 1.6-3644Flow rate - multi-channel 0.01–336 N/A 0.005–336 N/A 0.005–336 N/Apump, ml/minSpeed range, rpm 10–120 50–600 5–120 24–600 5–120 24–600Dimensions (wxhxd), mm 166x225 166x225 166x225 166x225 166x225 166x225

x256 x256 x256 x256 x256 x256Weight, kg 6.8 6.2 8.2 7.6 8.3 7.7

Cat. No. Description Price

521-600 PD 5001 pump drive POA

521-601 PD 5006 pump drive POA

521-602 PD 5101 pump drive POA

521-603 PD 5106 pump drive POA

521-604 PD 5201 pump drive POA

521-605 PD 5206 pump drive POA

Pump drives are supplied without a pump head or tubing. Please see below for details.

Single-Channel Peristaltic Pump HeadsSP quick and SP quick d Pump HeadsDesigned for fast and convenient tube changes and suitable for tubing with a 1.6mm or 2.5mm wallthickness. The flow rate ranges from 0.3 to 3,300ml per minute depending on drive and tubing. Toattach two pump heads to one drive unit, choose SP quick in combination with SP quick d.

■ Designed for cleaning in industrial washing machines ■ Low pulsation due to 5 roller system ■ Pump head features ball bearings ■ Rollers made of stainless steel

SpecificationsModel SP quick 1.6 SP quick 2.5 SP quick d 1.6 SP quick d 2.5Flow rate ranges, ml/min 0.3–2217 11.2–3300 0.3–2217 11.2–3300Tubing wall thickness, mm 1.6 2.5 1.6 2.5Number of rollers 5 5 5 5

Cat. No. Description Price

521-630 SP quick 1.6 pump head POA

521-631 SP quick 2.5 pump head POA

521-632 SP quick d 1.6 pump head POA

521-633 SP quick d 2.5 pump head POA

To attach two pump heads to one drive unit, choose SP quick in combination with SP quick d.

SP standard Pump Head Recommended for standard applications and suitable for tubing with a 1.6mm or 2.5mm wall thickness.The flow rate ranges from 0.5 to 3,344ml per minute depending on drive and tubing.

■ Recommended for standard applications ■ High pulsation due to 2 roller system ■ Pump head features ball bearings ■ Rollers made of stainless steel and polyamide ■ Convex rollers do not squeeze or crush organic cell cultures

SP vario Pump HeadSuitable for most Heidolph tubing due to adjustable roller spacing. The flow rate ranges from 0.5 to3,344ml per minute depending on drive and tubing.

■ Direction of rotation clockwise only ■ Rotor is removable for cleaning purposes ■ High pulsation due to 2 roller system■ Pump head features ball bearings■ Rollers made of stainless steel and aluminium■ Convex rollers do not squeeze or crush organic cell cultures

521-604 shown with 521-631 New

521-605 shown with 521-634 New

521-631 New

521-631 with 521-633 New

521-633 New

Page 30: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukHeidolph

Pumps

776 Take a look at our latest products on www.ecomcat.co.uk

Peristaltic Pump Drives and Heads, continued…SpecificationsModel SP standard 1.6 SP standard 2.5 SP varioFlow rate ranges, ml/min 0.5–3644 17.3–3644 0.5–3644Tubing wall thickness, mm 1.6 2.5 Various*Number of rollers 2 2 2

Cat. No. 521-634 521-635 521-636

Price POA POA POA

* Suitable for most Heidolph tubing due to adjustable roller spacing. For more information please contact ourTechnical Office on 01342 826836.

Multi-Channel Peristaltic Pump Heads There is a choice of three multi-channel pump heads which accept 4, 8 or 12 cassettes. The feed rate ofeach channel can be adjusted by using different tubing dimensions. Tubing is available in a variety ofmaterials and sizes and can be changed easily. Other features include 4 or 8 rollers for minimal pulsationand cassettes may be changed during operation. Cassettes must be ordered separately.

C4 Multi-Channel Pump Head The C4 pump head has 8 rollers for low-pulsation and accepts 4 small cassettes. Cassettes may bepartially used and click easily into place.

C8 Multi-Channel Pump Head This model has a 4-roller design and accepts 8 medium or 4 large cassettes. Medium and large sizecassettes may be used together. Cassettes may be partially used and click easily into place.

C12 Multi-Channel Pump Head The C12 pump head has 8 rollers for low-pulsation and accepts 12 small cassettes. Cassettes may bepartially used and click easily into place. Built-in reduction gear allows feeding of smallest quantities.

Cat. No. Description Price

521-637 C4 Multi-channel pump head POA

521-638 C8 Multi-channel pump head POA

521-639 C12 Multi-channel pump head POA

521-643 Adaptor for multi-channel pump heads* POA

521-640 Small cassette for C4 and C12 pump heads POA

521-641 Medium cassette for C8 pump head POA

521-642 Large cassette for C8 pump head POA

* A multi-channel adaptor is required to connect the pump drives PD 5001, PD 5101 and PD 5201 to a multi-channelpump head (pump drives PD 5006, PD 5106 and PD 5206 are not suitable for use with multi-channel pump heads). Also,if you already have a Heidolph single drive pump an adaptor is required to connect this to a multi-channel pump head.

Peristaltic Tubing for Single-Channel Pump Heads Supplied in lengths of 1m, wall thickness 1.6mm.

Flow rates (ml/min) of pump drives with single-channel pump headsTubing bore, mm 0.8 3.1 6.3

SP quickPD 5106/5206 1.6–40 25.7–643 88.7–2217PD 5006 3.3–40 53.6–643 184.8–2217PD 5101/5201 0.3–8.0 5.2–129 17.7–443PD 5001 0.7–8.0 10.7–129 37.0–443

SP standard/SP VarioPD 5106/5206 2.4–60.2 41.2–1029 146–3644PD 5006 5.0–60.2 85.8–1029 304–3644PD 5101/5201 0.5–12.0 8.2–206 29.2–729PD 5001 1.0–12.0 17.2–206 60.7–729

Silicon Cat. No. 521-606 521-607 521-608

Price POA POA POA

Tygon Cat. No. 521-609 521-610 521-611

Price POA POA POA

Other tubing sizes are available including, 1.7mm and 4.8mm. The following tube sizes are also available with a wallthickness of 2.5mm: 4.8, 6.3 and 7.9mm. For details on these and other tubing materials (Viton®, PharMed®, Tygon®

(hydrocarbon, food)) please contact our Technical Office on 01342 826836 for details.

521-638New521-637New

521-636New521-634New

521-641New

521-642

521-640New

521-639New

New

521-643New

Page 31: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

PumpsHeidolph

Take a look at our latest products on www.ecomcat.co.uk 777

Silicon tubingPeristaltic Tubing for Multi-Channel Pump Heads Three-stop tubing is supplied in lengths of 40cm. Extension tubing is supplied in lengths of 1m.

Flow rates (ml/min) of pump drives, pump heads with cassettesTubing bore, mm 0.2 0.5 0.9 1.4 2.8

PD 5101/ 5201Cassette small/pump head C12* 0.005–0.12 0.02–0.5 0.05–1.24 0.11–2.8 0.33–8.2Cassette small/pump head C4** 0.024–0.60 0.11–2.5 0.25–6.24 0.56–13.9 1.63–40.8

PD 5001Cassette small/pump head C12* 0.01–0.12 0.04–0.5 0.10–1.24 0.23–2.8 0.68–8.2Cassette small/pump head C4** 0.05–0.60 0.21–2.5 0.52–6.24 1.16–13.9 3.40–40.8

Silicon

Three-stop tubing for Small CassetteCat. No. ———— ———— 521-612 521-613 521-614

Price ———— ———— POA POA POA

Extension tubingCat. No. ———— ———— 521-615 521-616 521-617

Price ———— ———— POA POA POA

Tygon®

Three-stop tubing for Small CassetteCat. No. 521-618 521-619 521-620 521-621 521-622

Price POA POA POA POA POA

Extension tubingCat. No. 521-623 521-624 521-625 521-626 521-627

Price POA POA POA POA POA

* Maximum number of cassettes: 12. ** Maximum number of cassettes: 4.

Cat. No. Description Price

521-628 Fitting for extension tubing (PTFE) for 0.2, 0.5, 0.9 and 1.4mm tubing POA

521-629 Fitting for extension tubing (PTFE) for 2.8mm tubing POA

The fittings for extension tubing are supplied in a pack size of one. Therefore a minimum of two should be orderedto connect extension tubing on both sides of the three-stop tubing.

Flow rates 1 ml/min of pump drives, pump heads with cassettesTubing bore, mm 0.8 3.1 6.3

PD 5101/ 5201Cassette medium/pump head C8* 0.29–7.2 ———— ————Cassette large/pump head C8** ———— 3.8–96.0 13.5–336

PD 5001Cassette medium/pump head C8* 0.6–7.2 ———— ————Cassette large/pump head C8** ———— 8.0–96.0 28.0–336

* Maximum number of cassettes: 8. ** Maximum number of cassettes: 4.

This is the same tubing as listed for the single-channel pump heads, please see previous page for pricing and orderingdetails.

Other tubing sizes are available including, 1.7mm and 4.8mm. For details on these and other tubing materials(Viton®, PharMed®, Tygon® (hydrocarbon, food)) please contact our Technical Office on 01342 826836 for details.

New

Tygon tubing New

521-628 New

Three-stop tubing

New

Page 32: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukWatson Marlow

Pumps

778 Take a look at our latest products on www.ecomcat.co.uk

519-000 101U/R Auto/ Manual Control, Variable Speed Peristaltic PumpLow flow variable speed pump which is ideal for small volume, single channel applications includingfermenter feed.

Instant changeover between manual and analogue auto control. Fitted with rapid tube loading 102Rpumphead which accepts silicone tubing.

SpecificationFlow rate ranges (ml/min)for tube bore, mm 0.5 0.8 1.6 3.2 4.8at 1.0-32 rpm 0.021–0.69 0.048–1.61 0.210–7.00 0.780–26.0 1.590–53.0

Speed range, rpm 1.0–32Dimensions (hxwxl), mm 100x160x210Weight, kg 2.4Standards BS800, IEC 335-1, EN60529 (IP31), CE

Cat. No. Description Price

519-000 101U/R Auto/manual control, variable speed peristaltic pump POA

For silicone tubing see page 779.

323 Series Manual/ Remote/ Auto Control, Single/MultipleChannel PumpsA range of pumps with manual, remote or auto control through a single channel and flow rates up totwo L/min, or through up to ten channels using manifold tubing for microlitre flows.

Details are given here for 323 drives fitted with 313D single channel pumpheads which can be extendedup to a maximum of six individual channels. For microlitre flows, 323 drives can also be fitted with thefour roller 314MC pumphead, or eight roller 318MC pumphead. These pumpheads have five individualcassettes which accept double segment manifold tubing and can be extended by one pumphead toprovide a maximum of ten channels.

323S/D high-performance manual control variable speed pumps■ Flows rates to 2L/min per channel ■ Snap-fit 313X extension pumpheads provide up to six channels ■ Keypad lock prevents tampering or accidental changes ■ Two year comprehensive warranty

323S/D speed adjusts in 1rpm steps from 3 to 400rpm. Instantly reversible, rapid-loading flip-toppumphead accepts seven tube sizes, keypad lock prevents tampering or accidental changes, auto restartfor mains failure recovery.

323U/D analogue auto/manual control variable speed pumpSame specification as 323S/D above but with remote 4–20mA or 0–10V analogue auto-control via aplug-in control card mounted on the rear panel.

SpecificationFlow rate ranges (ml/min)tube bore 0.5 0.8 1.6 3.2 4.8 6.4 8.03.0-400rpm 0.09–12 0.21–28 0.81–110 3.0–400 6.6–880 11–1400 15–2000

Speed range, rpm 3.0–400rpmPumphead fitted 313D three roller pumpheadDimensions (hxwxl), mm 125x230x225Weight, kg 4.7Standards IEC 335-1, EN60529 (IP31), CE

Cat. No. Description Price

519-008 323S/D Manual control variable speed pump POA

519-030 323U/D Analogue auto/manual control variable speed pump POA

519-031 323S/D Manual control variable speed pump, drive only* POA

519-032 323U/D Analogue auto/manual control variable speed pump, drive only* POA

519-033 313X Three roller extension pumphead (maximum of 5) POA

* Order the drive only to enable 314MC or 318MC pumpheads to be fitted, see next page.For tubing also see next page.

■ Flow rates from 0.001 to 53ml/min■ Reversible flow with Max priming switch

■ Accepts auto-control signals up to 30V or32mA and TTL remote control pumphead

■ Two year comprehensive warranty

519-008

519-034

Page 33: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.uk

PumpsWatson Marlow

Take a look at our latest products on www.ecomcat.co.uk 779

323 Series, continued…Cassette pumpheads for microlitre flow ratesFor low-flow pumping through up to ten channels, 323S and 323U drives may be fitted with 314MC(four-roller) and 318MC (eight-roller) microcassette pumpheads, which can be extended to ten channelsby adding one 314MCX or 318MCX extension pumphead.■ 314MC four-roller higher-flow five channel cassette pumphead ■ 314MCX four-roller extension pumphead – add one to 314MC for ten channel pumping ■ 318MC eight roller higher-accuracy five channel cassette pumphead■ 318MCX eight roller extension pumphead – add one to 318MC for ten channel pumping

Cat. No. Description Price

519-034 314MC four-roller pumphead POA

519-036 318MC eight-roller pumphead POA

519-035 314MCX four-roller extension pumphead (maximum one extension pumphead) POA

519-037 318MCX eight-roller extension pumphead (maximum one extension pumphead) POA

Double pump segment manifold pump tubing for 314MC and 318MC microcassette pumpheads314MC and 318MC pumphead flow rate ranges (ml/min) - maximum 10 channels. Note: Speed mustnot exceed 110rpm.

Flow rates (ml/min) at 3.0-110 rpm for 323S and 323U drives

Description Cat. No. Price Cat. No. Price

Colour code Bore Marprene (Pack of 6) PVC (Pack of 12)

Orange/Blue 0.25mm 519-047 POA 519-048 POA

Orange/Yellow 0.50mm 519-049 POA 519-050 POA

Black/Black 0.76mm 519-051 POA 519-052 POA

Orange/Orange 0.88mm 519-053 POA 519-054 POA

Red/Red 1.14mm 519-055 POA 519-056 POA

Grey/Grey 1.29mm 519-057 POA 519-058 POA

Yellow/Blue 1.52mm 519-059 POA 519-060 POA

Green/Green 1.85mm 519-061 POA 519-062 POA

Purple/Black 2.29mm 519-063 POA 519-064 POA

Purple/White 2.79mm 519-065 POA 519-066 POA

Peristaltic Pump Tubing Supplied in lengths of 15m.

Pumpsil®

Platinum-cured Silicone tubing manufactured by Watson-Marlow.

■ Tighter bore and wall tolerances (no negative tolerance) ensure flow stability and accuracy ■ LaserTraceability™, laser etched lot number full length of tubing ensures true traceability ■ Pumpsil meets or exceeds : USP class VI; European Pharmacopoeia 3.1.9; ISO 10993; FDA

regulations CFR 177.2600 for contact with food; USDA standards; 3A standards

Marprene

Cat. No. Bore, mm Price

519-011 0.5 POA

519-012 0.8 POA

519-013 1.6 POA

519-014 3.2 POA

519-015 4.8 POA

519-016 6.4 POA

519-017 8.0 POA

Silicone

Cat. No. Bore, mm Price

519-018 0.5 POA

519-019 0.8 POA

519-020 1.6 POA

519-021 3.2 POA

519-022 4.8 POA

519-023 6.4 POA

519-024 8.0 POA

Bioprene

Cat. No. Bore, mm Price

519-040 0.5 POA

519-041 0.8 POA

519-042 1.6 POA

519-043 3.2 POA

519-044 4.8 POA

519-045 6.4 POA

519-046 8.0 POA

314MC 318MCOrange/Blue 0.25mm 0.01–0.5 0.01–0.5Orange/Yellow 0.50mm 0.05–1.7 0.04–1.4Black/Black 0.76mm 0.13–4.6 0.11–3.9Orange/Orange 0.88mm 0.17–6.4 0.14–5.3Red/Red 1.14mm 0.27–9.9 0.24–8.8

314MC 318MCGrey/Grey 1.29mm 0.35–13 0.27–10Yellow/Blue 1.52mm 0.52–19 0.38–14Green/Green 1.85mm 0.76–28 0.55–20Purple/Black 2.29mm 1.1–40 0.79–29Purple/White 2.79mm 1.4–53 0.98–36

Bioprene tubing

Pumpsil® PlatinumSilicone tubing

Marprene tubing

Page 34: Laboratory pumps vacuum pumps peristaltic pumps …uk.vwr-cmd.com/ex/downloads/jencons/pdf/catalogue/pumps.pdfFluid Aspiration Pumps 750 Take a look at our latest products on Ilmvac,

Order by phone➤ 01342 826836 Order on-line➤ www.ecomcat.co.uk

Order by fax➤ 01342 826771 Website➤ www.jencons.co.ukWatson Marlow

Pumps

780 Take a look at our latest products on www.ecomcat.co.uk

519-084 520 Series PumpsThe new 520 range from Watson-Marlow allows the pumps to be matched to the task for accurateresults without compromise, now and in the future. The high-flow 520R pumphead and maintenancefree brushless high powered drives provide the best performance, long life and great value.

520S/R Manual Control Variable Speed PumpsFitted as standard with the new pumphead 520R. It features large swept volume with sprung stainlesssteel rollers for high accuracy and gentle pumping of shear sensitive fluids. Low rotational speeds greatlyincrease tube life and system reliability.

* Also accepts 520R 2.4mm wall tubing pumphead for maximum flow and other multi-channel pumphead options.

Flow rates ranges (ml/min) for 1.6mm wall tubingTube bore 1.6 3.2 4.8 6.4 8.00.1 to 220rpm 0.04–97 0.18–390 0.40–870 0.70–1500 1.1–2400Dimensions (hxwxl), mm/Weight, kg 158x276x385 (all models)/9.6 (all models)Power 135VA (all models)Standards: CE, CETL US (all models)

Cat. No. Description Price

519-084 520S/R Manual control variable speed pump POA

520U/R Auto/Analogue, Manual Control Variable Speed PumpThe 520U/R shares all the features of the 520S/R plus:

Flow rates ranges (ml/min) for 1.6mm wall tubingTube bore 1.6 3.2 4.8 6.4 8.00.1 to 220rpm 0.04–97 0.18–390 0.40–870 0.70–1500 1.1–2400Dimensions (hxwxl), mm/Weight, kg 158x276x385 (all models)/9.6 (all models)Power 135VA (all models)Standards: CE, CETL US (all models)

Cat. No. Description Price

519-085 520U/R Auto/analogue, manual control variable speed pump POA

520Du/R Digital /Analogue Manual Control Variable Speed PumpThe 520Du/R shares all the features of the two models above plus:

* Also accepts 520R2 pumphead for use with 2.4mm wall thickness tubing and other multi-channel pumphead options.

Flow rates ranges (ml/min) for 1.6mm wall tubingTube bore 1.6 3.2 4.8 6.4 8.00.1 to 220rpm 0.04–97 0.18–390 0.40–870 0.70–1500 1.1–2400Dimensions (hxwxl), mm/Weight, kg 158x276x385 (all models)/9.6 (all models)Power 135VA (all models)Standards: CE, CETL US (all models)

Cat. No. Description Price

519-086 520Du/R Digital/analogue manual control variable speed pump POA

For tubing see page 779.

■ Flow rates from 4 microlitres/min up to 3.5litres/min * in 0.1rpm steps

■ Digital RS 485 control

■ Mimic control of stoke length/speed ofdiaphragm/piston pump

■ Inputs: Analogue 0–10V/4–20mA softwareconfigurable and calibrated, 0–10V ana-logue or 0–1258Hz speed indication output

■ Inputs: Run/stop, direction, leak detected,auto/manual toggle, MemoDose remotefoot switch, all accepting 5VTTL or 24Vindustrial logic

■ Outputs: 4 status outputs, 5V TTL or 24Vindustrial logic, user set-up for run/stop,direction, auto/manual status and choice ofalarm conditions

* Also accepts 520R 2.4mm wall tubing pumpheadfor maximum flow and other multi-channel pumphead options.

■ Flow rates from 4 microlitres/min up to 3.5 litre/min*

■ Brushless motor, high power and precisionspeed control

■ Large digital display and easy to use tactilemembrane keypad. Incorporates keypad lock

■ Manual control and flow calibration ■ MemoDose for accurate single shot dispensing ■ Dual voltage, 115V/230V 50/60Hz and

24 hour duty rated ■ Stackable ■ 3 year comprehensive warranty

New

519-085New

519-086New